KAZ V425 Humidifier Parts Owner’s Manual

July 11, 2024
KAZ

KAZ V425 Humidifier Parts

KAZ-V425-Humidifier-Parts-Product

Product Information

Specifications

  • Model: KAZ V425
  • Warranty: 2 years for models 4100, 4200, and 4220
  • Power Source: Electric
  • Recommended Water Type: Distilled or demineralized water
  • Manufacturer: Appliance Factory Parts

Product Usage Instructions

Important Safety Instructions

  1. Place the humidifier on a firm, flat, level surface at least five inches away from walls and heat sources.
  2. Keep the humidifier out of the reach of children.
  3. Inspect the cord for damage before using the humidifier.
  4. Always unplug and empty the humidifier when not in use or during cleaning.
  5. Avoid tilting or moving the humidifier while in operation.
  6. Regularly clean the humidifier as per the Care and Cleaning instructions.
  7. Use distilled or demineralized water in areas with hard tap water to prevent mineral emissions into the air.
  8. Consult a physician before using the humidifier if you have breathing difficulties.

Care and Cleaning
Follow these steps to clean your humidifier:

  1. Unplug the humidifier before cleaning.
  2. Empty any remaining water from the tank.
  3. Use a mixture of water and vinegar to clean the tank and base.
  4. Rinse thoroughly and allow all parts to dry completely before reassembling.

Troubleshooting
If you encounter issues with the humidifier, shut off the motor, unplug the unit, and contact the Consumer Service Department for assistance. Do not attempt to repair the motor yourself.

Frequently Asked Questions (FAQ)

  • Q: What type of water should I use in the humidifier?
    A: It is recommended to use distilled or demineralized water to prevent mineral emissions into the air.

  • Q: How often should I clean the humidifier?
    A: The humidifier requires regular cleaning. It is advised to clean it as per the Care and Cleaning instructions provided in the manual.

Important Safety Instructions

READ ALL INSTRUCTIONS BEFORE USING HUMIDIFIER, ESPECIALLY THESE BASIC SAFETY PRECAUTIONS.

  1. Always place the humidifier on a firm, flat, level surface, at least FIVE inches away from walls and heat sources such as stoves, radiators, or heaters. Humidifiers may not work properly on a non-level surface.
  2. Place a humidifier in an area that is out of the reach of children.
  3. Before using the humidifier, extend the cord and inspect for any signs of damage. Do not use the product if the cord has been damaged.
  4. Humidifiers should always be unplugged and emptied when not in operation or while being cleaned.
  5. Never tilt or move the humidifier while it is in operation. Shut off and unplug before moving.
  6. The humidifier requires regular cleaning. Read and follow Care and Cleaning instructions.
  7. In certain areas, tap water is extremely hard, containing a higher-than-normal concentration of various minerals. These minerals can be emitted into the air, possibly causing adverse reactions in people with breathing difficulties. In such cases, use only distilled or demineralized water and clean the humidifier every day. (See Care and Cleaning instructions).
  8. If you have breathing difficulties, consult your physician before using any humidification product.
  9. In hard-water areas, white dust may form on furniture. This can easily be wiped away with a cloth. To avoid the white dust, use distilled water.
    • As a condition of sale, the purchaser assumes responsibility for the proper care and use of this appliance per our printed instructions. The purchaser or user must judge for himself or herself when to use it and the length of use.

Troubleshooting

IF THE UNIT DOES NOT OPERATE:

  • Check that the polarized plug is fully inserted into a wall outlet.
  • Check airflow. Are there any obstructions preventing airflow?
  • The motor contains a temperature-limiting fuse. If the motor overheats, the fuse will trip and shut off the motor. Unplug the unit and contact our Consumer Service Department. Do not attempt to repair the motor yourself.

IF YOU DO NOT OBTAIN ENOUGH HUMIDITY:

  • Because of break-in characteristics, maximum output will not be reached until the unit has been used several times. If the air in the room is extremely dry, there will be greater absorption of the vapor and faster depletion of the water reservoir. As the humidity increases, output will decrease, and adding water will be required less frequently. This variation is normal.
  • Under certain conditions, the moisture output may not be visible. It is operating properly, however, if the water level goes down during usage, even when you cannot see the vapor.
  • The DynaFilter cartridge may be clogged with pollutants and should be replaced.

IF YOU ARE OBTAINING TOO MUCH HUMIDITY AND WATERFALLS OUT AROUND THE UNIT:

  • Room air may be excessively humid (greater than 50% relative humidity); do not use a humidifier. Oversaturated air can cause condensation on cold walls or furniture. For proper humidity readings, use a hygrometer available in most hardware and department stores.
  • The humidifier may need cleaning. Follow Care and Cleaning instructions.
  • Medication or other additives may have been added to the water. Follow Care and Cleaning Instructions.

Limited Warranty

Models 4100, 4200, and 4220 are warranted against defective material or workmanship for 2 years from the date of purchase. Any defective part will be repaired or replaced at no charge if it has not been tampered with and the appliance has been used according to these printed directions. This Warranty gives you specific legal rights as well as other rights which vary from state to state. If you experience unsatisfactory operation, first refer to the troubleshooting section above to ensure that it is not due to care or cleaning. Follow Care and Cleaning instructions.

If you have any questions or comments, call the Kaz Consumer Service Department at 800-827-6712 or, write to Kaz, Consumer Service Dept., One Vapor Trail, Hudson, NY 12534, explaining just how the product is operating. Specify the model number. Our Consumer Service Representative will advise you how to correct the problem yourself or will ask you to return the product for repair or replacement.

Order Information

To order replacement parts or DynaFilter K14 cartridge, follow these simple instructions:

  • CREDIT CARD PAYMENT
    We accept Visa® and MasterCard®.

  • TO ORDER BY PHONE
    Call toll-free by dialing 1-800-827-6712. Please have your credit card handy for payment. The minimum credit card order is $10.00.

  • TO ORDER BY MAIL
    Mail your order to Kaz Consumer Service Department, One V Hudson, NY 12534. Please clearly print your name, mailing address, products ordered, and price extension. Enclosed check or money order payable to Kaz, Incorporated (no cash, please). Orders by personal check will be held for 10 days for bank clearance.

  • TO ORDER BY FAX
    Fax your order to the Kaz Consumer Service Department at 1-518-828-2015. Please clearly print your name, mailing address, products ordered, and price extension. Specify either Visa® or MasterCard card number and expiration date, then sign your order. The minimum credit card order is $10.00.

  • TO ORDER VIA THE INTERNET
    E-mail us at consumerservice@kaz.com. Be sure to include your name, mailing address, products ordered, and price extension. Specify either Visa® or MasterCard®, card number, and expiration date. The minimum credit card order is $10.00.

    • DynaFilter K14-3 pack of 3 DynaFilters
    • Output Grille for Model 4200 or Model 4220 Add $4.00 per order for postage and handling. New Y please add applicable sales tax.

Note: Prices are subject to change without notice.

KAZ, Incorporated
One Vapor Trail Hudson, NY • USA • 12534 C.0159A.

How Your Humidifier Works

MODEL 4100

KAZ-V425-Humidifier-Parts-Fig- \(1\)

  • The Kaz HealthMist® 4100, 4200, and 4220 models produce a cool mist through revolutionary new cyclone technology. The motor-driven impeller draws up water through a pickup tube. Centrifugal force throws the water through a screen into the vortex chamber, breaking up the water into a superfine, cool mist.
  • Each of these cool mist humidifiers restores healthy humidity levels to dry indoor air more effi-ciently than other impeller-type humidifiers.

THE AIR-CLEANING DynaFilter

  • Kaz cool mist humidifiers include the exclusive Kaz DynaFilter K14. The DynaFilter removes dust, pollen, odors, and tobacco smoke from the air, removing 93% of particles as small as pollen.
  • Under normal environmental conditions, the filter cartridge should be replaced every two months. Replacement time will vary depending on the concentration of pollutants in the air. If you notice heavy dirt accumulation on the filter or if the humidifier output is significantly reduced, it’s time to change to a new DynaFilter!
  • Kaz DynaFilter K14 cartridges are available at leading pharmacies and drug departments. You may also order directly from Kaz (see Order Information on the back page).

Care and Cleaning

Tap water may contain pollutants and minerals (scale) that can be deposited on the inner surfaces of the humidifier. Such scale can accelerate the growth of microorganisms and it is important that periodic cleaning is performed as outlined below. More frequent cleaning may be necessary if you notice a heavy build-up of scale.

INSPECT THE DNA FILTER
Remove and inspect the DynaFilter cartridge for dirt and dust accumulation. If you notice heavy accumulation, the filter needs to be replaced. If the filter is not changed regularly will clog the filter, impair air flow, reduce the efficiency of the humidifier, and may damage the motor.

Safety Instruction

Read and Save These Instruction

  1. CAUTION: UNRAVEL CORD BEFORE USE. Failure to do so could cause overheating and possible fire hazards. Always disconnect the cord at the wall plug before removing the T in use.

  2. INSERT DYNAFILTER CARTRIDGE. Simply remove the outer protective cartridge into the recess of the Top Housing ( Inspect used DynaFilters. If you notice heavy dirt accumulation, it

  3. PLACE HUMIDIFIER IN A SAFE POSITION on the floor, table, or other FIRM, FLA Protect rug, floor, or furniture by placing the unit on a waterproof non-conducting pad or mat for pro-tection against inadvertent spillage. Do not place any object over the humidifier; it could block air openings.
    The cord should be out of the way, where it cannot be pulled or stepped on. When used therapeutically, the humidifier should be placed at least 4 feet from the bedside and out of the reach of children.

  4. FILL CAREFULLY. The exclusive Kaz FillChannel™ permits convenient Housing.

    • Model 4100: Pour cool tap water into FillChannel. Fill until the water level reaches the W Indicator on the front of the bowl.
    • Models 4200 and 4220: Look down into the FillChannel. Y on the lower step. Using a pitcher, add cool tap water IMPORTANT: DO NOT OVERFILL, as this will cause water spillage and possible damage to floors or furniture.
  5. PLUG-IN HUMIDIFIER. Be sure that the switch is in the Off ( Plug the power cord into the wall.
    CAUTION: DO NOT PLUG IN THE CORD WITH WET HANDS; ELECTRIC SHOCK COULD RESULT This product has a polarized plug (one blade is wider than the other) as a safety feature. The plug
    will fit into a polarized outlet only one way. If the plug does not fit properly into the
    plug. If it still does not fit, contact a qualified electrician. feature.

  6. FOR MODEL 4200: Turn the switch to the On (I) position.
    FOR MODEL 4220: Turn the switch to either of the two speeds – Low
    CAUTION: Turn off the humidifier if moisture condenses on cold sure be excessively humid.

  7. DIRECTING MIST (Models 4200 and 4220 only) Rotate the Output Grille or turn the product to prevent mist
    from settling on tables or other pieces of furniture.

IMPORTANT: To maintain proper operation of your humidifier instructions.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals