Reactec RLW001 Eco System R-Link HAVS Monitor Watch User Guide
- July 10, 2024
- REACTEC
Table of Contents
Hardware Overview
RLW001 Eco System R-Link HAVS Monitor Watch
About this document
This document is supplied as a part of the Reactec Eco-system.
Intended purpose
This document is intended to outline the specification details of the hardware
within the Reactec Eco-system.
Intended audience
This document is intended for all users of the Reactec Eco-system.
Original instructions
Read this document before using the equipment
Retain this document for future use
Document information
Published on: 26 June 2024
Document ID: 290-270 – 3
Copyright and proprietary information
Copyright © 2024 Reactec. All Rights Reserved. You must obtain prior written
permission for the republication or redistribution of any content.
This user guide is protected by national and international copyright and other
laws. Unauthorised storage, reproduction, transmission and/or distribution of
this user guide, or any part of it, may result in civil and/or criminal
proceedings.
Where this user guide and any associated documents refers to quotes and links
from the HSE please note that such public sector information is published by
the Health and Safety Executive and licensed under the Open Government License
v 3.0.
Trademarks
Other product and company names in these materials may be trademarks or
registered trademarks of other companies and are the property of their
respective owners. They are used only for explanation purposes only and to the
respective owners’ benefit, without intent to infringe.
Contact address
Reactec Ltd.
Vantage Point,
3 Cultins Road,
Edinburgh,
EH11 4DF
Contact Reactec support if you have any questions:
helpdesk@reactec.com
www.reactec.com/support
Registered in Scotland (no. SC221428).
USA Regulatory Information
The following applies to the R-Link Watch, R-Link Charger, R-Link 2 Bay
Gateway and R-Link Beacon:
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions;
- This device may not cause harmful interference, and this
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
The following applies to the R-Link 2 Bay Gateway and R-Link Beacon only:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. End users must follow the specific operating
instructions for satisfying RF exposure compliance. This transmitter must be
at least 20 cm from the user and must not be collocated or operating in
conjunction with any other antenna or transmitter.
R-Link Watch Contains FCC ID: VPYLB2AB .
This regulatory information can be found when the Watch is powered up by
pressing the left button to enter the System menu then pressing the right
button to show the Regulatory Info screen. The screen below will be shown.
USA Representatives:
Honsa Ergonomic Technologies, Inc
1300 11th St W
Milan
IL 61264
Telephone No: +1 309-756-0200
OHD LLLP
2687 John Hawkins Parkway
Hoover
Alabama
AL 35244
Telephone No: +1 205-980-0180
Canada Regulatory Information
The following applies to the R-Link Watch, R-Link Charger, R-Link 2 Bay
Gateway and R-Link Beacon:
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
The following applies to the R-Link 2 Bay Gateway and R-Link Beacon only:
This transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter. This equipment should be installed and operated
with a minimum distance of 20 centimetres between the radiator and your body.
R-Link Watch Contains IC: 772C-LB2AB .
This information can be found when the R-Link Watch is powered up by pressing
the left button to enter the System menu then pressing the right button to
show the Regulatory Info screen. The screen below will be shown.
Canada Representatives:
Levitt Safety
2782 Bristol Circle
Oakville
Ontario
Canada
L6H 5T5
Telephone No: +1 905-829-3299
Fax No: +1 905-829-291
Conventions used
This guide uses the following formats for safety notices.
WARNING
Provides important information to prevent serious problems, for example, the
loss of data.
Caution
Provides important information to prevent serious problems, for example, the
loss of data.
Information
Provides additional information.
Tip
Provides useful hints and tips.
R-LINK watch – RLW-001
FCC ID: 2AYGF-RLW001 IC ID: 31188-RLW001
1.1 Specifications
Table 1 – R-LINK watch specifications
Specification | Details |
---|---|
Power | Internal lithium-ion rechargeable. Not user serviceable |
Charging Power Input | 5V DC, 0.25A |
Charge time to full charge | 1 to 2 hours after a typical days use depending on |
enabled functions.
From fully discharged 3 hours.
Battery life| Max battery life – 16 hours
Operating Environment| For Indoor and Outdoor use. Can be operated in wet and
dusty environments up to Pollution Degree 4. Maximum altitude of 2000m
Operating temperature| -20°C to +40°C / -4°F to +104°F
Storage temperature| -20°C to +40°C / -4°F to +104°F
Charging temperature| -0°C to +40°C / +32°F to +104°F
Humidity| up to 100% RH
Enclosure rating| EN60529/IEC60529 to IP67, UL50E Type 4 Enclosure
Communication| 13.56MHz close range RFID, BLE 5, Ultra Wideband
Dimensions| 41.1 mm / 1.61 inches Width
41.5 mm / 1.63 inches Depth
16.3 mm / 0.64 inches Thickness
Weight| 30 grams / 1.1 Ounces
1.2 Care
Keep the R-LINK watch, in particular the underneath, clean to ensure a good
connection between the watch and the charging station.
An isopropanol or similar alcohol-based cleaning agent with an alcohol content
of at least 70% is recommended for cleaning. Use of chemicals not fitting this
description may cause damage.
The R-LINK watch is a sealed unit. Do not attempt to dismantle or modify it.
Caution
When placing the R-LINK watch back into a charging station, do not press down
on the LCD screen of the watch. Repeated or excessive force may damage the
watch.
R-LINK 10-bay charging station – RLC-001
2.1 Specifications
Table 2 – R-LINK 10-bay charging station specifications
Specification | Description |
---|---|
Power | 12V DC, 2.5A or 24V DC 1.25A. 12V DC |
Mains adaptor provided
Operating Environment| For Indoor use only. Maximum altitude of 2000m
Operating temperature| 0°C to +40°C / +32°F to +104°F
Storage temperature| -20°C to +40°C / -4°F to +104°F A3
Humidity| up to 95% RH
Dimensions| 226 mm / 8.9 inches Width
334 mm / 13.1 inches Length
70 mm / 2.8 inches Thickness
Weight| 900 grams / 31.75 ounces
2.2 Installation
When identifying a location for the charging station, consider the following:
- The charging station should be wall mounted with at least a 150mm clearance above and below and access to a power socket for the power lead.
- When positioning the charging station horizontally, ensure the area is clear on all sides of the charging station, with a 300mm clearance above.
- The charging station must be within communication distance of a Gateway.
This is typically 30m.
Figure 3 – R-LINK charging station
Caution
Do not mount or place the charging station on an unstable surface or near a
heat source, such as a radiator, or in direct sunlight This can damage the
units.
2.3 Care
To ensure continued operation, keep the charging station clean, in particular
ensure the gold connector pins are free of dirt.
An isopropanol or similar alcohol-based cleaning agent with an alcohol content
of at least 70% is recommended for cleaning. Use of chemicals not fitting this
description may cause damage.
Apply with a cloth and with the charging station powered down.
Information
The charging station must not be located in outdoor or dusty environments.
R-LINK 2 bay gateway – RLG-002(INT)
3.1 Specifications
Table 3 – R-LINK 2-Bay Gateway specifications
Specification | Description |
---|---|
Power | 12V DC, 2.5A or 24V DC 1.25A. 12V DC |
Mains adaptor provided
Operating Environment| For Indoor. Maximum altitude of 2000m.
Operating Temperature| 0°C to +40°C / 32°F to +104°F
Storage Temperature| -20°C to +40°C / / -4°F to +104°F
Humidity| up to 95% RH
Communications| Mobile Data, BLE 5 and UWB
Dimensions| 130 mm / 5.1 inches Width
175 mm / 6.9 inches Length
45 mm / 1.8 inches Thickness
Weight| 400 grams / 14.1 ounces
3.2 Installation
When identifying a location for the 2 bay gateway, consider the following:
- The 2 bay gateway should be wall mounted with at least a 150mm clearance above and below and access to a power socket for the power lead.
- If positioning the 2 bay gateway horizontally, ensure the area is clear on all sides of the Gateway, with a 300mm clearance above.
- The 2 bay gateway housing includes two mounting points.
Figure 4 – R-LINK 2 Bay Gateway
Caution
Do not mount or place the 2 bay gateway on an unstable surface or near a heat
source, such as a radiator, or in direct sunlight. This can damage the unit.
3.3 Care
To ensure continued operation, keep the gateway clean, in particular ensure
the gold connector pins are free of dirt.
An isopropanol or similar alcohol-based cleaning agent with an alcohol content
of at least 70% is recommended for cleaning. Use of chemicals not fitting this
description may cause damage.
Apply with a cloth and with the 2 bay gateway powered down.
Information
The 2 bay gateway must not be located in outdoor or dusty environments.
R-LINK beacon – RLB-001(HW)
4.1 Specifications
Table 4 – R-LINK beacon specifications
Specification | Description |
---|---|
Power | 12V DC, 2.5A or 24V DC 1.25A. 12V DC Mains adaptor provided. |
Operating Environment | For Indoor and Outdoor use. Can be operated in wet and |
dusty environments up to Pollution Degree 4.
When external power input is disconnected rubber cap must to be fitted to the
connector to ensure no water ingress. Maximum altitude of 2000m.
Operating Temperature| -20°C to +40°C / -4°F to +104°F
Storage Temperature| -20°C to +40°C / -4°F to +104°F
Humidity| up to 100% RH
Enclosure rating| EN60529/IEC60529 to IP66, UL50E Type 4 Enclosure
Communications| BLE 5 and UWB
Dimensions| 110 mm / 4.1 inches Width
150 mm / 6.0 inches Length
40 mm / 1.6 inches Thickness
Weight| 250 grams / 8.8 ounces
4.2 Installation
When identifying a location for the Beacon, consider the following:
- The beacon should be mounted as high as possible on the vehicle above head height. It is preferable to have the beacon protrude above metal surfaces. A range of attachment brackets are available to install as best suits the vehicle.
- For large vehicles it may be necessary to mount two beacons at diagonally opposite corners
- Ensure the Beacon is fully charged before installing.
- The Beacon housing includes two mounting points. Refer to the following drawing for the details of the mounting points.
4.3 Care
To ensure continued operation, keep the Beacon clean.
An isopropanol or similar alcohol-based cleaning agent with an alcohol content
of at least 70% is recommended for cleaning. Use of chemicals not fitting this
description may cause damage.
Apply with a cloth and with the Beacon powered down.
References