renqiu XMZ-TB20 Bluetooth Smart Switch
Product Specifications
- Working Mode: Gear mode, Temperature control mode
- Gear Range : 1 to 10
- Temperature Range: 8~36 degrees Celsius
Product Usage Instructions
Working mode
XMZ-TB20 Operation Instructions:
- In gear mode, the gear can be adjusted within the range of 1 to 10 gears;
- In temperature control mode, the set temperature can be adjusted within the range of 8~36
- The gear of the control switch changes with the temperature inside the cab. When the temperature rises or falls, the control switch will automatically adjust the operating gear to quickly reach the set temperature, making the heater run more intelligent and economically.
- When a fault occurs during operation, the control switch will display a flashing window to display the fault code, making it easier to find the fault more accurately and intuitively.
Operating instructions:
On/Off and Mode Switching:
Press the [On/Off ] button to turn on the device in the off state; Press the
[O n / O f f ] b u t t o n to turn off the device when it is turned on; Press
the [Settings ] button to switch between the current gear/temperature control
mode/constant temperature heating;
Gear Adjustment:
Press the 【increase 】button to run gear/temperature+1, up to 10 gears/36 ℃,
press th e 【decrease 】button to run gear/temperature -1, down to 1 gear/8 ℃;
Basic Settings:
After turning on the device, press and hold the [Settings] button for 3
seconds to enter the basic settings interface. Use the [Add]/[Subtract] keys
to make changes and press the [Set] key to confirm the data modification.
Press the [Plus]/[Minus] keys to adjust settings. Press the [Settings] key to
save the basic settings.
- F0: Current time
- F1: Self start time
- F2: Running time 【After self start 】
- F3 : Self start switch setting
- F4: Language switching [Chinese (C), English (E), Russian (R), voice off (–)]
- F5: Temperature compensation
- F4 : Language switching [Chinese (C), English (E), Russian (R), voice off (–)]
- F5: Temperature compensation
- F6: Fuel tank volume [5-50L (switch unit 5L) (default 10L)] [Display – represents not monitoring fuel tank condition]
- F7: Fuel pump type [16/22/28/32UL (default 22UL)]
- F8 : Constant temperature heating (in temperature control mode, when the temperature reaches the set temperature, it will automatically shut down after a delay o f 30 seconds; when the temperature is 2 ℃ lower than the set temperature, it will automatically start up after a delay o f 30 seconds)
- F9 : Temperature switching: (℉/℃)
- FA: Screen brightness
- Fb: Full fuel tank
- FC: CO value detection (this function is used with CO sensor)
- Fd: Running time switch
Press the [Add ]/[Subtract] key to make changes, and then press the [Set] key again to confirm the current data modification; Press the [Plus ]/[Minus] keystoadjust the settings. After all adjustments are successful, press the [Settings] key to save the basic settings ; Press the [On/Off ] button to return to the operating interface;
Engineering Mode:
Press the [Add ]/[Subtract] keys simultaneously for 3 seconds while turning on
the device to enter engineering mode. The current project will be displayed in
the upper right corner, and the interface will display specific data under the
project. Press the [Add]/[Subtract ] keys to adjust the project check
View Data:
- En00: Heater motherboard version number [scrolling display]
- En01: Fault code
- En02: Shell temperature
- En03: Power supply voltage
- En04: Heater operating gear
- En05: cab temperature;
- En06: Altitude;
- En08 : Remote control matching;
- E n09: Bluetooth matching;
Quick remote control matching: In the power on state, long press the 【add button 】; Enter the En08 interface, and the screen displays “P-1”. At this time, press any key on the remote control to successfully match and return to the running interface;
-
* **Clear the last remote control matching data:** During the power on self-test, press and hold the [On/Off] button. The interface displays “C L r” to start clearing. When the interface displays “SU C”,theclearing is successful.
- Bluetooth matching: open the mobile phone applet, click the setting key, set th e 4-digit password, and then adjust the switch to enter the engineering mode En09, and the interface displays “B L e”, and the Bluetooth name is displayed on the upper right side of the screen,
- Long press and hold the [Settings] button for 3 seconds , and the flashing original password in the upper right corner will change to the displayed setting password, and the interface display will change to “SUC”. After successful matching, it will automatically return to the running interface;
- When the password is consistent, click on the corresponding Bluetooth name to connect successfully;
- Pump oil mode: Press and hold the [Pump oil button ] for 5 seconds when the power is turned off for the first time , until the screen flashes and the countdown starts 300 seconds. After the countdown ends, the pump oil will automatically exit or press the [On/Off ] button to end the pump oil and shut down;
- Check CO, detection value : Press and hold the power on button while turning on the machine; (This function is used with CO sensors)
- Fault display: When the heater malfunctions, the display area flashes a fault code, and the fault type is shown in the table below;
Fault codes | fault type | Troubleshooting |
---|---|---|
E-01 | Abnormal voltage | Check if the voltage type of the heater supply matches |
the actual vehicle voltage; Check if the power supply voltage of the 24V version is higher than 32V or lower than 18V; 12V version;
Check if the power supply voltage is higher than 18V or lower than 9V; Check if there is any looseness or virtual connection at the main harness connector;
E-03| Abnormal ignition plug| Check if the ignition plug is connected
improperly; Igniter plug malfunction, replace the ignition plug; Main board
malfunction, replace the main board;
E-04| Abnormal oil pump| Check if the oil pump plug is loose or connected in a
virtual manner; Check if there is an open circuit in the main harness; Oil
pump malfunction, replace oil pump;
E-05| Overheat protection| The furnace temperature sensor model is incorrect
or faulty, replace the sensor; Main board malfunction, replace the main board;
E-06| Fan abnormality| Check if the fan impeller is stuck; Check if the fan
plug is loose or connected improperly; Fan malfunction, replace the fan;
Check if the induction magnet of the wind turbine is missing or has incorrect polarity; Check if the motherboard wind speed sensor is functioning properly; Main board malfunction, replace the main board;
E-08| Lack of fuel and stalling| Check if the fuel tank is short of oil;
E-09| Overheat protection sensor| Check if the temperature sensor connector is
loose or poorly connected; Sensor malfunction, replace the motherboard; Main
board malfunction, replace the main board;
E-10| Secondary startup failure| Check if the oil pump is working; Check
whether the interfaces of the oil circuit are waxed or blocked;
E-11| CO alarm (concentration exceeding limit)| Check if the CO controller is
installed correctly (avoiding direct exhaust gas blowing controllers), and
check if the heater is installed correctly; Replace the CO controller;
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
- this device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation
NOTE : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Warning: changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment
We Chat Mini Program Apple (IOS) APP
Search air Header Ble’on the APP Store Android APP
Frequently Asked Questions
Q: How do I adjust the temperature in temperature control mode?
A: Use the increase/decrease buttons to adjust the temperature within the
range of 8~36 degrees Celsius.
Q: What should I do if a fault occurs during operation?
A: The control switch will display a flashing window with a fault code. Refer
to the manual to identify and troubleshoot the issue.