CHANGXIE 2BG89 Electronic Scale Instruction Manual
- July 6, 2024
- CHANGXIE
Table of Contents
CHANGXIE 2BG89 Electronic Scale
Specifications
- Accuracy: 5000g/1g, 10000g/1g, 15000g/1g
- Buttons: ON/OFF power button, MODE Unit key, TARE Zero key, PCS Count key
- Unit conversion: g / kg/water ml/milk ml / tl / lb: oz / fl: oz
- Operating Voltage: 3V
- Operating temperature: 10 to 30 degrees Celsius
Product Usage Instructions
Scale Status Description
Place the electronic scale on a horizontal table, lightly press the power button to turn it on, and long press the power button to turn it off. Note:
- If there is no operation or connection for 100 seconds, the scale will automatically shut down.
- When the battery is too low, the buzzer on the scale will sound continuously, indicating that the battery of the scale is too low. Please replace the battery in time.
- The green light is always on, indicating that the scale is working.
Display Status Description
Place the monitor on a horizontal desktop, and lightly press the power button ON/OFF to turn on the monitor. After turning it on, the display will flash in a loop (searching for devices). After connecting to the device, the display indicates a successfulconnection, and 0 will be displayed. Note:
- The light will automatically turn off if there is no operation for 10 seconds and will automatically turn on when the weight or value changes.
- The light will automatically turn off if there is no operation or connection for 100 seconds.
Unit Conversion
When the machine is turned on, each time you press the Unit button, a
weighing unit will be converted. Please select the weight unit you need. Note:
This product has multiple units for conversion.
Tare and Zero
Place the container on the weighing pan, press the Reset button, and after
the display returns to zero, place the items to be weighed into the container.
The weight displayed at this time is the weight of the items (the weight of
the container is not included).
Instructions for use
Thank you very much for purchasing our electronic scale product. Please
read this instruction manual carefully before use. Correct use and maintenance
will extend the service life of the product.
Display back instructions
Display Magnet Instructions
- Tear off the anti-sticking paper on the surface of the metal magnet sheet
- Use the strong magnet on the monitor to suck the metal magnet sheet to the position corresponding to the strong magnet (for fixing the size), and then press the monitor to fix it on the background wall.
Monitor support bracket instructions
Open the support frame and the display can be placed on any horizontal table
for clearer reading.
Wireless connection
1. When the display and the scale are powered on at the same time, they will
automatically connect.
2. The wireless connection will be faster if the scale is powered on first
and then the display
Specs and Features
- Specifications/Accuracy: 5000g/1g,10000g/1g,15000g/1g
- Unit conversion[g / kg / water ml / milk ml / tl / lb:oz / fl:oz ]
- Operating Voltage:3V
- button: ( power button ) ( Unit key) ( Zero key ) ( Count key)
- Operating temperature: 10 to 30 degrees Celsius
power supply
This product adopts an ultra-low power consumption environmentally friendly
design and uses four No. 7 batteries. After purchasing this product, please
remove the insulating film of the battery and install the battery before using
the product.
Scale Status Description
Place the electronic scale on a horizontal table, lightly press the power
button on the scale to turn it on, and long press the power button to turn it
off.
Note
- If there is no operation or connection for 100 seconds, the scale will automatically shut down.
- When the battery is too low, the buzzer on the scale will sound continuously, indicating that the battery of the scale is too low. Please replace the battery in time.
- The green light is always on, indicating that the scale is in a working state
Display status description
Place the monitor on a horizontal desktop, lightly press the power button “
” to turn on the monitor, and after turning it on, the display ” ” will flash
in a loop (this state is searching for devices). After connecting to the
device, the display ” ” indicates a successful connection, and “0 ” will be
displayed.
Note
- The light will automatically turn off if there is no operation for 10 seconds and will automatically turn on when the weight or value changes
- The light will automatically turn off if there is no operation or connection for 100 seconds.
Unit conversion
When the machine is turned on, each time you press the “Unit” button, a
weighing unit will be converted. Please select the weight unit you need.
Note: This product has multiple units for conversion
Tare and zero
Place the container on the weighing pan, press the “Reset” button, and after
the display returns to zero, place the items to be weighed into the container.
The weight displayed at this time is the weight of the items (the weight of
the container is not included).
Counting function The prerequisite for the counting function to be realized is that the weight of each item to be counted must be the same.
- Turn on the machine as described above.
- Prepare 25, 50, 75, or 100 samples, and place the items on the scale pan for weighing and sampling.
- Press and hold the [ ] key until the number “25” is displayed and then release it.
- If the displayed number is different from the number of samples placed on the scale pan. Press the [ ]key to switch to the correct sample number. After switching correctly, press the [ ] key to confirm.
- Remove the sample and place the item to be counted. The display will show the number of items.
General Care and Maintenance
- This instrument is a precision instrument. Please do not drop it or subject it to a strong impact to avoid product failure.
- When storing the product, do not place any objects on the scale platform or load other items, otherwise, it will cause malfunction.
- Avoid exposure to extreme heat or cold. Always allow your scale to acclimate to normal room temperature before use.
- Place the scale in a clean and dry environment. Dust, dirt, moisture, vibration, or proximity to other electronic devices may adversely affect the accuracy and reliability of the scale.
- Handle with care and gently place all items to be weighed on top of the scale pan. Although the electronic scale is designed to be very durable, rough use should be avoided as this may permanently damage the internal components
Troubleshooting
The main reasons for inaccurate weighing and malfunction are low battery, incorrect calibration, weighing items exceeding the maximum range of the product not operating on a level surface, etc.
- Searching for devices
- 【 Lo 】 It indicates that the battery power is low, please replace the battery in time.
- 【 0_Ld 】 If overweight, remove the overweight items immediately.
- 【 UNST 】 If the product is unstable, windy, vibrating, or not level, please place it on a hard surface in a windless, level, and undisturbed environment.
- 【 】 If the buzzer on the scale beeps continuously, it means the battery power of the scale is too low. Please replace the battery in time.
Precautions
Pairing is required when changing monitors After powering on and resetting
to zero, press and hold the MODE and TARE buttons for 2 seconds. The display
will show PASS, indicating successful pairing If you have any questions about
this product, please feel free to contact us.
FCC
This equipment has been tested and found to comply with the limits for a Class B digital device, under part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used by the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Caution
Any changes or modifications to this device not explicitly approved by the
manufacturer could void your authority to operate this equipment. This device
complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions:
(1)This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause
undesired operation. This equipment complies with FCC radiation exposure
limits set forth for an uncontrolled environment. This equipment should be
installed and operated with a minimum distance of 0cmbetween the radiator and
your body.
Frequently Asked Questions
-
Q: How do I connect the display wirelessly to the scale?
A: When both the display and scale are powered on at the same time, they will automatically connect. For a faster wireless connection, power on the scale first and then the display. -
Q: What should I do if the scale automatically shuts down?
A: If there is no operation or connection for 100 seconds, the scale will automatically shut down. Simply turn it back on by pressing the power button.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>