EMERSON RP4AF Bettis RTS Relay Board Electric Actuator Instruction Manual

June 3, 2024
Emerson

EMERSON-RP4AF-Bettis-RTS-Relay-Board-Electric-Actuator-
logo

EMERSON RP4AF Bettis RTS Relay Board Electric Actuator

EMERSON-RP4AF-Bettis-RTS-Relay-Board-Electric-Actuator-product-
image

Revision Details June 2021

Installation, Operation and Maintenance Manual
VCIOM-15749-EN Rev. 0

Revision Details

No. Date Version Type of Change
1 June 2021 0 General update (Migration to new template)

Section 1: Tools

WARNING
Remove all power supplies before doing the exchange. Act always with caution during the exchange!

  • Needle nose pliers
  • Screw driver Philips
  • Screw driver flat
  • Allen key 5
  • Socket wrench 5
    EMERSON-RP4AF-Bettis-RTS-Relay-Board-Electric-
Actuator-01

Section 2: Material

  • 1x relay board RP4AF (ID:15772)
  • 2x steel screw M3x16 (ID:952)
  • 3x plastic distance 8 mm (ID:9896)
  • 1x plastic screw M3x15 (ID:9895)
  • 1x plastic nut M3 (ID:7084)
  • 2x lock plates M3 red (ID:13674)

EMERSON-RP4AF-Bettis-RTS-Relay-Board-Electric-
Actuator-02

EMERSON-RP4AF-Bettis-RTS-Relay-Board-Electric-
Actuator-03

Section 3: Installation

Unscrew the 4 hexagon socket screws from the cover and remove it carefully. Mind the connection cable between display and logic board.EMERSON-RP4AF-
Bettis-RTS-Relay-Board-Electric-Actuator-04

Unscrew the 4 cross recessed screws from the existing logic board and afterwards tilt it carefully to you.
EMERSON-RP4AF-Bettis-RTS-Relay-Board-Electric-
Actuator-05

Remove the cable with the 10-pole connector and connect it with the relay board.
EMERSON-RP4AF-Bettis-RTS-Relay-Board-Electric-
Actuator-06

Insert plastic screw M3x15 in provided hole and add plastic distance on it, after connect the relay board with the logic board on suitable connector. Add plastic nut on plastic screw to
fix the board.
EMERSON-RP4AF-Bettis-RTS-Relay-Board-Electric-
Actuator-07

Put two plastic distances 8 mm between logic and relay board, insert the M3x16 steel screws through the estimated holes in logic board, plastic distances and relay board and secure the screws with the red lock plates.
EMERSON-RP4AF-Bettis-RTS-Relay-Board-Electric-
Actuator-08

Install die logic + relay board back to the control (two small screws for original installation will remain). Take care of possible damage of cables or other parts.
EMERSON-RP4AF-Bettis-RTS-Relay-Board-Electric-
Actuator-09

Connect cable between display cover and logic board. Perform a Firmware update now, before installing display cover on the unit. This update is important for the following programming steps (use FW version display 1507, logic 219 or higher). For a detailed description on how to perform a firmware update, please refer to separate manual.
During display cover installation, pay attention to the O-ring which must be sit correct between cover and housing and fix it with the 4 hexagon socket screws.
EMERSON-RP4AF-Bettis-RTS-Relay-Board-Electric-
Actuator-10

Section 4: Programming

For programming, request download of SMARTTOOL2 through your Sales Representative.
After the successful installation and registration, connect with the actuator. Use the Wizard and choose function “Install Extension Kit” and press “Apply”.
EMERSON-RP4AF-Bettis-RTS-Relay-Board-Electric-
Actuator-11

At the line “RP4AF: 4x Relay Outputs” press “Apply” and confirm the installation by pressing “Ja”.
EMERSON-RP4AF-Bettis-RTS-Relay-Board-Electric-
Actuator-12

After installation press the “Refresh Button”. In parameter group “10. Relay” you can define the functionality of the different relay’s.
EMERSON-RP4AF-Bettis-RTS-Relay-Board-Electric-
Actuator-13

This page is intentionally left blank
World Area Configuration Centers (WACC) offer sales support, service, inventory and commissioning to our global customers.
Choose the WACC or sales office nearest you:

NORTH & SOUTH AMERICA

  • 19200 Northwest Freeway
  • Houston TX 77065
  • USA
  • T +1 281 477 4100
  • Av. Hollingsworth
  • 325 Ibofanga Sorocaba
  • SP 18087-105
  • Brazil
  • T +55 15 3413 8888

ASIA PACIFIC

  • No. 9 Gul Road
  • 01-02 Singapore 629361

  • T +65 6777 8211
  • No. 1 Lai Yuan Road
  • Wowing Development Area
  • Tianjin 301700
  • P. R. China
  • T +86 22 8212 3300

MIDDLE EAST & AFRICA

  • P. O. Box 17033
  • Jebel Ali Free Zone
  • Dubai
  • T +971 4 811 8100
  • P. O. Box 10305
  • Jubail 31961
  • Saudi Arabia
  • T +966 3 340 8650
  • 24 Angus Crescent
  • Longmeadow Business Estate East
  • P.O. Box 6908 Greenstone
  • 1616 Modder fountain Extension 5
  • South Africa
  • T +27 11 451 3700

EUROPE

  • Holland Fasor 6
  • Székesfehérvár 8000
  • Hungary
  • T +36 22 53 09 50
  • Strada Biffi 165
  • 29017 Fiorenzuola d’Arda (PC)
  • Italy
  • T +39 0523 944 411

For complete list of sales and manufacturing sites, please visit www.emerson.com/actuationtechnologieslocations or contact us at info.actuationtechnologies@emerson.com

www.emerson.com/bettis
VCIOM-15749-EN ©2021 Emerson. All rights reserved.
The Emerson logo is a trademark and service mark of Emerson Electric Co. BettisTM is a mark of one of the Emerson family of companies.
All other marks are property of their respective owners.
The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability.
All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Emerson User Manuals

Related Manuals