DETTSON Chinook Modulating Gas Furnace Owner’s Manual

July 3, 2024
Dettson

DETTSON Chinook Modulating Gas Furnace

DETTSON-Chinook-Modulating-Gas-Furnace-PRODUCT

Specifications

  • Brand: Chinook
  • Primary Heat Exchanger Material: Stainless Steel (SS 409)
  • Secondary Heat Exchanger Material: AL 29-4C
  • Electrical Data : 115 Volts, 60 Hertz, 1 Phase

Product Usage Instructions

Features

  • Properly sized modulating furnace for even room temperatures
  • Stainless steel extruded tube heat exchangers for reliability
  • Double folding to avoid sharp edges
  • Easy access to components for maintenance
  • The control board is located in the top compartment
  • Multiposition-ready ID blower
  • Transparent drain trap

Electrical Data

Input (BTU/h) Maximum Consumption (Amps / Breaker Size)
15,000 (Compact) 8.6 / 10
15,000 12.6 / 15

Features

  • Efficiency up to 97.3 % AFUE
  • Multiposition-Ready
  • Convenient, easy access to all controls and components
  • Up to 300 feet of venting
  • Propane conversion kits are available
  • Zero-clearance on sides
  • Energy Star® certified
  • Quiet operation
  • Up to an altitude of 4500 ft without modification

A properly sized modulating furnace will run for longer periods, helping homeowners achieve:

  • Even temperatures throughout the house
  • Lower energy consumption
  • Longer equipment life
  • Quieter, healthier and more comfortable home

Reliable appliance that offers a safe maintenance environment

DETTSON-Chinook-Modulating-Gas-Furnace-FIG-1

  • The smallest central gas heating unit designed for multifamily units /garages / basement suites
  • 10” wide x 23” tall
  • Low airflow rate for optimal comfort and quieter operation
  • Allows the Right-Sized System® in combination with our Alizé heatpump unit
  • Up to 1T of cooling
  • Modulating in heating mode: 6,000 to 15,000 BTU/h

DIMENSION

DETTSON-Chinook-Modulating-Gas-Furnace-FIG-2

“It’s hard to beat having a homeowner come up to you thanking you for installing a furnace and air conditioner system that is so quiet they keep checking on it to see if it’s working.

Constant temperature, high efficiency and quieter performance are some of the benefits that our customers are commenting on. As I’ve said before it’s like swapping out your old gas guzzling tank for a Porsche. As a new home designer, I am extremely excited to be now exploring the impact of the Smart Duct System on my floor designs.

This is a revolution in improved HVAC performance offering full home comfort and energy efficiency to the homeowners.”

ELECTRICAL DATA

INPUT| | 15K COMPACT| 15K| 30K| 45K| 60K| 75K| 105K| 120K
---|---|---|---|---|---|---|---|---|---
MAXIMUM CONSUMPTION

(Amps / breaker size)

| MODULATING| 8.6 / 10| 12.6 / 15| 12.6 / 15| 12.6 / 15| 15.6 / 20| 15.6 / 20| 19.0 / 20| 19.0 / 20
2-STAGE ECM| N/A| 12.6 / 15| 12.6 / 15| 12.6 / 15| 15.0 / 15| 15.0 / 15| N/A| N/A
SUPPLY| 115 Volts – 60 Hertz – 1 Phase

MODULATING GAS FURNACE
This furnace requires an interface board and the communicating thermostat to interlock with ERV/HRV when not installed in combination with our Alizé heatpump.

To identify approved products, please visit: www.energystar.gov

MODELS| | CC15-M-V| C15-M-S| C15-M-V| C30-M-S| C30-M-V| C45-M-S| C45-M-V| C60-M-V| C75-M-V| C105-M-V| C120-M-V
---|---|---|---|---|---|---|---|---|---|---|---|---
INPUT (BTU/h)| HIGH| 15,000| 15,000| 15,000| 30,000| 30,000| 45,000| 45,000| 60,000| 75,000| 105,000| 120,000
LOW| 6,000| 6,000| 6,000| 12,000| 12,000| 18,000| 18,000| 24,000| 30,000| 42,000| 48,000
OUTPUT (BTU/h)| HIGH| 14,445| 14,595| 14,595| 28,860| 28,860| 43,515| 43,515| 58,080| 72,000| 101,430| 116,400
LOW| 5,780| 5,840| 5,840| 11,545| 11,545| 17,405| 17,405| 23,230| 28,800| 40,570| 46,560
EFFICIENCY (%)| 96.3| 97.3| 97.3| 96.2| 96.2| 96.7| 96.7| 96.8| 96.0| 96.6| 97.0
TEMPERATURE RISE| 20-55 °F (11-30 °C)| 40-70°F (22-39°C)



AIRFLOW (CFM)

| HEATING HIGH| 400| 310| 310| 480| 480| 720| 720| 1,025| 1,200| 1,680| 1,920
HEATING LOW| 160| 310| 310| 385| 310| 330| 330| 430| 480| 670| 770
**MAX*| 580| 1,200| 1,200| 1,200| 1,200| 1,200| 1,200| 1,600| 1,600| 2,000| 2,000
MAX**| 400| 1,000| 800| 1,200| 800| 1,200| 800| 1,200| 1,200| N/A| N/A
MAX COOLING CAPACITY (TONS)| TRADITIONAL DUCTS| 1| 3| 3| 3| 3| 3| 3| 4| 4| 5| 5
SMART DUCTS| 1| 2.5| 2| 3| 2| 3| 2| 3| 3| N/A| N/A
MOTOR HP| 1/3| 3/4| 1/2| 3/4| 1/2| 3/4| 1/2| 3/4| 3/4| 1| 1
SHIP WEIGHT (LB / KG)**| 79 / 35.8| 115 / 52.2| 115 / 52.2| 116 / 52.6| 116 / 52.6| 119 / 54.0| 119 / 54.0| 136 / 61.7| 138 / 62.6| 161 / 73.0| 171 / 77.6

  • MAX CFM for ESP of 0.5” w.c.
  • MAX CFM for Smart Duct™

2-STAGE VARIABLE SPEED MOTOR GAS FURNACE

MODELS| | C15-2-V| C30-2-V| C45-2-V| C60-2-V| C75-2-V
---|---|---|---|---|---|---
INPUT (BTU/h)| HIGH| 15,000| 30,000| 45,000| 60,000| 75,000
LOW| 10,500| 21,000| 31,500| 42,000| 52,500
OUTPUT (BTU/h)| HIGH| 14,430| 28,890| 43,200| 57,420| 71,925
LOW| 10,100| 20,225| 30,240| 40,195| 50,350
EFFICIENCY % (AFUE)| 96.2| 96.3| 96.0| 95.7| 95.9
TEMPERATURE RISE| 25-55°F (14-31°C)| 30-60°F (17-33°C)| 40-70 °F (22-39 °C)


AIRFLOW (CFM)

| HEATING HIGH| 335| 595| 735| 1,000| 1,230
HEATING LOW| 270| 415| 535| 690| 830
MAX| 1,000| 1,000| 1,000| 1,400| 1,400
MAX COOLING CAPACITY (TONS)| 2.5| 2.5| 2.5| 3.5| 3.5
MOTOR HP| 1/2| 1/2| 1/2| 3/4| 3/4
SHIP WEIGHT (LB / KG)| 119 / 54.0| 119 / 54.0| 119 / 54.0| 136 / 61.7| 138 / 62.6

DIMENSIONS (INCHES)

INPUT (kBTU)| WIDTH (A)| SUPPLY PLENUM| FILTER SIZE
---|---|---|---
15 to 45| 13.50| 12.50 x 19.00| ****

20 x 16

25 x 16

60 to 75| 15.75| 14.75 x 19.00
105 to 120| 21.00| 20.00 x 19.00

MORE INFORMATION

ADDRESS: 3400, Industrial Boulevard Sherbrooke, Quebec J1L 1V8 Canada

T 1.819.346.8493 TF 1.800.567.2733 F 1.819.822.4227 info@dettson.ca www.dettson.com
Specifications subject to change without notice

FAQ

  • Q: What are the benefits of using a Chinook right-sized furnace?
    • A: The benefits include even room temperatures, energy efficiency, extended equipment life, reduced noise, and improved homeowner satisfaction.
  • Q: Where can I find approved products for use with the Chinook furnace?
    • A: Please visit www.energystar.gov to identify approved products for use with the Chinook furnace.

References