Dettson EVD-24-O EVO High Efficiency Central Heat Pump System Instructions
- June 23, 2024
- Dettson
Table of Contents
Dettson EVD-24-O EVO High Efficiency Central Heat Pump System Instructions
High Efficiency Central Heat Pump System
Installation Flexibility
We offer you 2 options to meet all your needs:
-
An installation with the EVO Air Handler to enjoy our complete EVO system
-
To reduce labor and equipment costs, you can install the EVO condenser in retrofit with a third-party indoor unit such as a preexisting or new furnace by adding our A-coil, for instance our Supreme electric furnace or our Chinook gas furnace.
Specifications
- 35% energy savings achieved by advanced inverter technology
- The side-discharged condenser allows installation in confined spaces
- Can be matched with most brands of air handler and A-coil
- Compatible with most thermostats on the market
- Electrical heating belt for compressor
- Self-diagnostic
- Self-Adapt mode enables ability to analyse temperature and pressure change of the unit to adjust operation
- Universal compatibility with third party applications
A System Built To Last
**EVO Condenser
**
A.Gold-Fin copper coil helps fight against corrosion in harsh
environments. Thin design allows for installation in compact areas.
B. Variable speed outdoor DC motor operates efficiently depending on
requirements. Fan blade designs allows for quiet operation.
C. Smart control board helps adjust output capacity allowing the unit to
maintain temperature at set level and helps control humidity during summer
months.
Improves performance and comfort automatically.
D. Inverter technology compressor with EEV valve helps to operate at high
efficiency levels during heating mode.
Can operate outside temperatures as low as -30°C (-22°F)
Outdoor Unit Dimensions: in (mm)
Models | W | H | D |
---|---|---|---|
EVD-24-O | 37 1/4 (946) | 31 7/8 (810) | 16 1/8 (410) |
EVD-30-O
EVD-36-O| 37 1/2 (952)| 52 1/2 (1333)| 16 11/32 (410)
EVD-48-O
EVD-60-O
**EVO Air Handler
**
E Smart control board with easy access. Allows for quicker maintenance.
F Flare connection for easy access when soldering is not possible. Solder
adaptors included.
G Multi-Positional drain pan flexible for vertical or horizontal
applications.
H Can accommodate electric heat with no modifications and easy access
installation. See table below.
I DC Motor allows for quiet operation while performing at efficiency
levels controlling humidity.
J Aluminum coil allows efficiency heat transfer, humidity removal and
easy maintenance. The EEV valve helps to operate at high efficiency levels
during cooling.
K Easy access filter-track.
L Integrated drain pan made from corrosion-resistant composite material
to help eliminate standing water.
EVO Electric Auxiliary Heat Module}
Models | Descriptions |
---|---|
EAH-05B-B | 5 kW electric auxiliary heat module |
EAH-10B-B | 10 kW electric auxiliary heat module |
EAH-15B-B | 15 kW electric auxiliary heat module |
EAH-20B-B | 20 kW electric auxiliary heat module |
EVO with Air Handler
Product # 1| Indoor Unit| EVD-24-I| EVD-30-I|
EVD-36-I| EVD-48-I| EVD-60-I
---|---|---|---|---|---|---
Outdoor Unit| EVD-24-O| EVD-30-O| EVD-36-O| EVD-48-O|
EVD-60-O
Technical Performance
Power Sulpply| V / Ph / HZ| 230 / 208 / 1 / 60
Cooling Capacity| Nominal| W (BTU/hr)| 7038 (24000)| 8792
(30000)| 10557 (36000)| 13783 (47000)| 16129 (55000)
Heating Capacity| Nominal| W (BTU/hr)| 7038 (24000)| 9671
(33000)| 11730 (40000)| 14663 (50000)| 17 302 (59000)
SEER2| –| 17.4| 16.2| 16| 15.6| 15.3
HSPF2 (Region IV)| –| 10| 8.9| 9.5| 9.4| 9.4
EER2| W/W| 11.7| 10| 10| 8.2| 8.8
COP at 5 ℉ (-15°C)| W/W| 1.91| 1.80| 1.97| 1.90| 1.91
COP at 47 ℉ (8,3°C)| W/W| 3.35| 3.30| 3.40| 3.16| 3.42
AHRI number| –| 210365432| 210365433| 210365434| 210365435|
210365436
Energy Star| –| ✓| ✓| ✓| ✓| ✓
Indoor Unit
Dehumidify deification| pt/hr (l/hr)| 3.48 (1.98)| 6.1 (3.49)| 6.1
(3.49)| 4.96 (8.72)| 9.77 (5.55)
Air flow volume| T / H / M / L 2| cfm| 824 / 759 /694
/ 629| 1088 / 894 /806 / 712| 1188 / 1082 /971 / 865| 1471 / 1282 /1094 / 906|
1806 / 1582 /1359 / 1135
Sound level| H / M / L| dB (A)| 39 / 36 / 33| 42 / 41 /
37| 45 / 43 / 41| 50 / 47 / 44| 51 / 46 / 42
Fan motor RLA| A| 3| 3.5| 4| 6| 7
MCOP| A| 15| 15| 15| 15| 15
Net weight| lb (kg)| 106 (48)| 129 (59)| 129 (59)| 131
(59)| 163 (74)
Outdoor Unit
Air flow volume| cfm| 3000| 3000| 4500| 4412| 4500
Sound level| dB (A)| 62| 60.5| 64| 64| 63.5
Compressor power input| W| 2085| 2765| 3565±3%| 3565±3%| 3770
MCA| A| 20.5| 23| 30| 40| 40
MCOP| A| 35| 35| 50| 50| 50
Compressor RLA| A| 15| 17.5| 32| 33| 26.2
Refrigerant volume (R410A)| oz (g)| 102 (2900)| 134 (3799)| 165.7
(4700)| 169 (4800)| 169 (4800)
Operating ambient temperature| Cooling| °C (°F)| -15 to 50
(5 to 122)
Heating| °C (°F)| -30 to 24 (-22 to 75)
Net weight| lb (kg)| 137 (62)| 160 (72.5)| 227 (103)| 220
(100)| 240 (109)
Connection Piping / Refrigerant
Pre-charge length| ft (m)| 25 (7.5)| 25 (7.5)| 25 (7.5)| 25 (7.5)|
25 (7.5)
Additional refrigerant charge| oz/ft (g/m)| 0.69 (65)| 0.69 (65)|
0.69 (65)| 0.69 (65)| 0.69 (65)
Liquid pipe outer diameter| in| 3/8| 3/8| 3/8| 3/8| 3/8
Gas pipe outer diameter| in| 3/4| 3/4| 3/4| 3/4| 7/8
Maximum height between outdoor and indoor units| ft (m)| 82
(25)| 82 (25)| 98 (30)| 98 (30)| 98 (30)
Maximum pipe length between outdoor and indoor units| ft (m)| 164
(50)| 164 (50)| 213 (65)| 213 (65)| 213 (65)
- indoor unit and 1 outdoor unit. Note that each unit is individually packaged.
- Fan Speeds: (T) Turbo / (H) High / (M) Medium / (L) Low.
Air Handler Dimensions
Model | A | B | C | D | E | F |
---|---|---|---|---|---|---|
EVD-24-I | 15 3/4(400) | **** 23 (585) | 10 1/4(260) | 17 1/2(445) | 21 | |
(534) | **** 45 (1143) | |||||
EVD-30-I | 19 1/4(488) | 23 (585) | 10 1/4(260) | 21 (534) | 21 (534) | 49 |
(1245)
EVD-36-I
EVD-48-I
EVD-60-I| 22 7/8(580)| 23 (585)| 10 1/4(260)| 21 (534)| 24 1/2(622)| 53
(1346)
EVO with A Coil
Specifications
- Up to 16.8 SEER2
- Available in multiple sizes : 17.5″, 21″, 24.5″
- Horizontal or Vertical cased coil flexibility
- Can be matched with third-party furnace or blower
- 24V or 485 Communication Mode
Product # 1| Indoor Unit| MAC24H1718E| MAC36H2124E|
MAC48H2124E| MAC60H2428E
---|---|---|---|---|---
Outdoor Unit| EVD-24-O| EVD-30-O| EVD-36-O| EVD-48-O|
EVD-60-O
Power Sulpply| V / Ph / HZ| 230 / 208 / 1 / 60
Cooling Capacity| Nominal| W (BTU/hr)| 7034 (24000)| 8792
(30000)| 10550 (36000)| 13481 (46000)| 15534 (53000)
Heating Capacity| Nominal| W (BTU/hr)| 7327 (25000)| 9671
(33000)| 11430 (39000)| 14947 (51000)| 15826 (54000)
SEER2| –| 16.5| 15.5| 15.2| 14.3| 14.5
HSPF2 (Region IV)| –| 9.5| 9.7| 10| 9| 8.6
EER2| W/W| 10.7| 10.5| 10| 8.6| 8.6
COP at 5 ℉ (-15°C)| W/W| 1.95| 1.85| 2.0| 1.80| 1.8
COP at 47 ℉ (8 , 3°C)| W/W| 3.32| 3.50| 3.10|
3.04| 3.08
AHRI number| –| 213460480| 213160482| 213160483| 213160484|
213160485
Energy Star| –| ✓| ✓| ✓| –| –
Indoor Unit
Air flow volume| (Max)| SCFM| 720| 960| 960| 1015|
Net weight| lb (kg)| 43 (19.5)| 67 (30)| 67 (30)| 67 (30)|
87 (39)
Dimension| W × D × H| In (mm)| 17½ × 21 × 18(445 × 535 ×
460)| 21 × 21 × 24(535 × 535 × 610)| 21 × 21 × 24(535 × 535 × 610)| 21 × 21 ×
24(535 × 535 × 610)| 24 ½ × 21 × 28(622 × 533 × 711)
Outdoor Unit
Air flow volume| cfm| 3000| 3000| 4500| 4500| 4500
Sound level| dB (A)| 63.5| 63| 61| 64| 62
Compressor power input| W| 2085| 2765| 3565±3%| 3565±3%| 3770
MCA| A| 20.5| 23| 40| 40| 40
MCOP| A| 35| 35| 50| 50| 50
Refrigerant volume (R410A)| oz (kg)| 102 (2900)| 134 (3.8)| 166
(4.7)| 169 (4.8)| 169 (4.8)
Operating ambient| Cooling| °C (°F)| -15 to 50 (5 to 122)
temperature| Heating| °C (°F)| -30 to 24 (-22 to 75)
Net weight| lb (kg)| 137 (62)| 160 (72.5)| 227 (103)| 220
(100)| 240 (109)
Connection Piping / Refrigerant
Pre-charge length| ft (m)| 25 (7.5)| 25 (7.5)| 25 (7.5)| 25 (7.5)|
25 (7.5)
Additional refrigerant charge| oz/ft (g/m)| 0.69 (65)| 0.69 (65)|
0.69 (65)| 0.69 (65)| 0.69 (65)
Liquid pipe outer diameter| in| 3/8| 3/8| 3/8| 3/8| 3/8
Gas pipe outer diameter| in| 3/4| 3/4| 3/4| 7/8| 7/8
Maximum height between outdoor and indoor units| ft (m)| 66
(20)| 82 (25)| 98 (30)| 98 (30)| 98 (30)
Maximum pipe length between outdoor and indoor units| ft (m)| 98
(30)| 164 (50)| 213 (65)| 213 (65)| 213 (65)
- indoor unit and 1 outdoor unit. Note that each unit is individually packaged.
TF 1.800.567.2733
info@dettson.ca
dettson.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>