Specifications

  • Dimension (W x D x H): SIMPO Cabinet 6 – 620 x 600 x 1270mm, SIMPO Cabinet 10 – 620 x 600 x 1890mm
  • Max. Qty of modules: SIMPO Cabinet 6 – 6 (30kWh), SIMPO Cabinet 10 – 10 (50kWh)
  • Max. continuous current: 625A, 1250A
  • IP Rate: IP20
  • Weight: SIMPO Cabinet 6 – 120 kg, SIMPO Cabinet 10 – 90 kg

Product Usage Instructions

Contents in SIMPO 5000 Package

Number Part Name Quantity
1 Terminal Resistor 1

Tools Required for Installation

  • Safety Shoes
  • Insulated Gloves

Extra Accessories

The following parts are necessary for connecting with the inverter:

  1. DC Cables With terminal SC xxx-12
  2. PE Cable With terminal SC xx-6

SIMPO 5000 Interface & LED Status

The front panel of SIMPO 5000 has LEDs indicating battery status and functions:

  • ALM LED: Operational State – Error occurs  There is no error existing
  • RUN LED: Operational State – The battery is ON and can be charged and discharged if no error / The battery is not working
  • SOC LED: SOC Indicator – 75%

Frequently Asked Questions (FAQ)

Q: Where can I purchase SIMPO WiFi for the system?
A: SIMPO WiFi can be bought from ZYC’s dealers.

Safety

When installing, commissioning, operating and maintaining the product, the safety requirements in the manual should be strictly observed. Incorrect operation or work may lead to damage to the product and other properties or injury or death of the operator or third parties.
When fixing the product with screws or other parts, use the correct tool and reinforce it with the torque indicated in the manual or on the label of the product, otherwise the product may be unstable or damaged. When using different tools, master the tools in advance to prevent the installer from being injured due to improper handling.
Please read this manual thoroughly before installation to ensure proper and safe installation and use of the product.

Warning & Caution

  • Installers and users are obliged to familiarise themselves with this manual.
  • Power Cables and plugs have high voltage from the battery, be careful when wiring.
  • Ensure that a fire extinguisher is in place prior to installation and use.
  • Installation and operation must be carried out by qualified personnel and the system must be installed in restricted access areas.
  • The battery module is with certain weight, it is better to be installed by at least two personel. With the help of tools if necessary.

Contents in SIMPO 5000 Package

Number Part Name Quantity
1 Terminal Resistor 1
2 PE Cable 1
3 Com Cable 1
4 Power Cable(+) 1
5 Power Cable(-) 1
6 Bolt M6 × 16 4

SIMPO Cabinet

Specification| SIMPO

Cabinet 6

| SIMPO

Cabinet 10

---|---|---
Dimension (W x D x H)| 620 x 600

x1270mm

| 620 x 600

x1890mm

Max. Qty of modules| 6(30kWh)| 10(50kWh)
Max. continuous current| 625A| 1250A
IP Rate| IP20
Weight| 120 kg| 90 kg

Tools

Extra Accessories

The parts below are not included in the accessories we offered, but necessary for connecting with inverter.

  1. DC Cables With terminal SC xxx-12
  2. PE Cable With terminal SC xx-6
  3. Com cable with shield (Cat5 or higher)
  4. SIMPO WiFi
  • Select appropriate cables according to the power of your system and electrical requirements.
  • PE Cables(CSA≥25 mm ) with Terminal(SCxx‑6).
  • Communication cable with shield (Cat5 or higher).
  • SIMPO WiFi can be bought from ZYC’s dealers.

SIMPO 5000 Interface & LED Status

Letter Label Function Letter Label Function
A MCB Circuit Breaker F ALM Alarming LED
B + DC+ Port G RUN Status LED
C INV Inverter Com H SOC SOC Indicator
D OUT Parallel Com Out I ON/OFF Switch On/OFF
E IN Parallel Com In J DC- Port

There are three LEDs on the front panel of SIMPO 5000 that indicate battery status,ALM, RUN and SOC.

Minimum Clear Space Requirement of Cabinets

Connect the Power Cables and PE Cable & Adjust the Feet For SIMPO Cabinet 6

Connect the Power Cables and PE Cable & Adjust the Feet For SIMPO Cabinet 10

Fix The Modules to The Cabinet

Connect Power Cables & PE Cables & Com Cables & Terminal Resistor

Connect To The Inverter

Connect the power cables and communication cable between battery system and inverter.

Notice:

  1. The communication cable should be Cat 5 or upper.
  2. For no communication mode, there is no need to connect the communication cable.

Definition of INV Port on Battery interface

PIN No. 1 2 3 4 5 6 7 8
Definition Null Null Null CAN_H CAN_L Null RS485B RS485A

Change the communication cable’s wires order if necessary. Matching with the CAN Communication inverters as below:

  SIMPO 5000 Victron Selectronic SMA Studer Steca Deye Noark GoodWe
CAN_H 4 7 1 4 4 4 4 4 4
CAN_L 5 8 2 5 5 5 5 5 5

Matching with the RS485 Communication inverters as below:

  SIMPO 5000 Lux Power
RS485A 8 2
RS485B 7 1

Connect Communication Cables for Multiple Cabinets In Parallel

Connect Power Cables & PE Cables & Communication Cable

Note:

  1. The maximum number of paralleled SIMPO 5000 modules is 64.
  2. When multiple cabinets are connected, a DC box is needed to combine the power cables from the cabinets.
  3. The DC power cable length for all the cabinets should be approximately equal.
  4. The communication cable length ≤5 m.

Switch to No Communication Mode

  • The SIMPO 5000 can operate normally without communication with the inverter. To switch to no-communication mode, please follow the procedures in the right figure.
  • Once the BMS is connected to the inverter with a communication cable, i t w i l l a utomat i ca l l y swi tc h to t he communication mode.

Operating procedure:

  1. Power on the battery.
  2. Press the “ON/OFF” button twice within 3 minutes.
  3. The SOC indicators will flash 3 times.

Power ON & Power OFF

System Start Up

  1. Turn on the DC breaker between battery and inverter (If any).
  2. Turn on all of the MCBs.
  3. Press the ‘ON/OFF’ button of Master battery for 1 seconds to power on batteries.
  4. Turn on the inverter.

System Shutdown

  1. Shut down the inverter.
  2. Turn off the DC breaker between battery and inverter (If any).
  3. Press and hold the ON/OFF button for 3 seconds on the Master battery to shut it down .
  4. Make sure the LED on the battery is off.

Connect to Internet & WiFi Usage & ZYC Portal & ZYC Assist APP

There are two options to connect to the internet with SIMPO WIFI

  1. Connect SIMPO WIFI to the router directly with a network cable.
  2. Set up a wireless connection for SIMPO WIFI through ZYC Assist APP.
    When the app is connecting with the hotspot of the SIMPO WiFi, follow the below steps:

Contact us

+86 (0)755-2839 4019
sales@zyc.energy
service@zyc.energy
www.zyc.energy
WhatsApp: +86 19168831702
www.zycportal.com
Guangke Road 1, Pingshan, Shenzhen, P.R. China

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals