neverdark F10 Firetec Smart Fireplace Instruction Manual

July 3, 2024
NEVERDARK

F10 Firetec Smart Fireplace

Specifications

Neverdark FIRETEC Smart Fireplace

  • European Standard EN 16647:2015 compliant

  • Power Cable: Euro Plug — WAGO

  • Dimensions (mm): Vary based on model (Refer to the table under
    DIMENSIONS section)

  • Weight: Varies based on model

  • Tank Volume: Varies based on model (Refer to the FEATURES
    section)

Product Usage Instructions

Installation

WARNING! Ensure the smart fireplace is
installed 100% horizontally for correct operation.

  1. Mounting handles securely according to the provided
    instructions.

  2. Connect the power cable either using a Plug 220V or a WAGO
    connector 220V 3×2.5mm.

  3. For the 220V cable connection, always consult a qualified
    electrician.

Niche Preparation

WARNING! Maintain specific clearances and
distances from flammable objects.

  • Niche Dimensions: Refer to the provided
    measurements for minimum requirements.

  • Niche Requirements: Maintain distances to
    flammable objects as specified.

  • Note: Consider using a non-heat-resistant
    material with Neverdark Thermobox as an alternative.

Features

Technical Information:

  • Tank Volume:
    • Firetec 700: 3.0 liters
    • Firetec 800: 3.7 liters

FAQ

Q: What should I do if I encounter a warning sign during

usage?

A: If you encounter a warning sign, stop using
the fireplace immediately and refer to the documentation for
guidance. If needed, contact customer support for assistance.

Q: Can I use the smart fireplace without connecting it to a

power source?

A: No, the smart fireplace requires a power
source for operation. Attempting to use it without power may result
in malfunction or damage.

Neverdark FIRETEC
Smart fireplace
TECHNICAL DOCUMENTATION

CONTENT
04 CONFIGURATION 04 Standard configuration 05 Optional Extra
06 THERMOBOXES
07 FIREPLACE INTERFACES
08 DIMENSIONS
09 NICHE PREPARATION 09 Niche dimensions 10 Niche requirements
11 INSTALLATION
12 FEATURES 12 Technical information 13 Warnings

FIREPLACE
INSTALLATION TECHNICAL INFORMATION

ATTENTION! This document, along with the User Manual, is part of the device and is being delivered along with the fireplace (hereinafter collectively referred to as «Instructions»). If one or both of these documents weren’t delivered with your fireplace, please contact the manufacturer prior to the installation and / or use of the fireplace.
Make sure to read this Technical Documentation (hereinafter «Documentation») before using the fireplace!
Keep this Documentation in a safe place for the lifetime of the fireplace!
This appliance by design, method of operation, consumer properties and technical safety fully complies with the requirements of the European Standard EN 16647:2015
ATTENTION! Please follow local laws when using the appliance.
SYMBOLS
FIRE AND BURN HAZARD SIGN
A WARNING SIGN indicates a potential for property damage, personal injury, or death
AN ATTENTION SIGN indicates important information

CONFIGURATION
Standard configuration
Smart fireplace
(Standard top panel Black glossy)
1 pc
Power cable: Euro Plug — WAGO
(fireplace length + 0.1m)
1 set
Mounting handles
2 pc

Fuel hose 1 pc
Packaging 1 pc
Documentation 1 set

standard configuration | 04

Optional extra You can add any option listed below:

Glass Border (one or two)
code GB (1, 2)
Custom Top (Matte (black),
RAL Glossy, RAL Matte, Inox)
code CT (M, RG, RM, I)

Remote Control
code RC Smart Home onnection module code SH
Enlarged Fuel Tank
code EFT

ARS (the external control and refuelling module) is available in three configurations:

Standard ARS
code S-ARS
05 | optional extra

Mini ARS (down)
code M-ARS(down)
Mini ARS (up)
code M-ARS(up)

THERMOBOXES
You can also choose the Neverdark Thermobox for your fireplace. The Thermobox can withstand temperatures up to 200°C, allowing you to choose any material for lining the niche.

Single-Sided
code TSS
Right Corner
code TRC
Left Corner
code TLC

Three-Sided
code TTS
Room Divider
code TRD
See-Through
code TST

thermoboxes | 06

FIREPLACE INTERFACES
Burner
No-touch sensor Control panel cover

Glow plug (candle)
Air ventilation grids

Power cable 220V

Fuel drainage unit (service only)

Power button

Touch display

07 | fireplace interfaces

Fuel hose connector

DIMENSIONS
Y

X FlamXe-l1i0ne0
Z

Standard range

Model
Firetec 700 Firetec 800 Firetec 1000 Firetec 1200 Firetec 1500 Firetec 2000 Firetec 2500

Code
F7 F8 F10 F12 F15 F20 F25

X
Length, mm
700 800 1000 1200 1500 2000 2500

Y Depth,
mm
250

Z Height,
mm
205

Weight, kg
21 24 31 35 44 58 72

dimensions | 08

NICHE PREPARATION
Niche dimensions

min 340

min 100

min X+190

min 400

270 min 220

Power outlet or connection point in a niche Cable 3×2.5
Clearance 6
Air supply 100 cm² min 20

X-10

min 50 240

mAinir10su0pcpmly² Clearance 6
227

WARNING! For correct operation of the smart fireplace, it must be installed 100% horizontally according to the level!

8 200

min 20

Clearance 6 min 20
09 | niche preparation

min 20

Niche requirements

min 1000

2 min 500
1
min 1000

miAnir10s0upcpmly² 1
WARNING! Min 1000 mm to flammable objects from any exposed side of the niche.
Min 500 mm to flammable objects from any closed side of the niche.

2
WARNING! Heat-resistant material which withstands 150°C at least.
Alternatively, a non heat-resistant material + Neverdark Thermobox

WARNING! For safe and correct operation of the fireplace it is mandatory to provide an air supply opening (100 cm² at least) in the lower part of the niche.
niche requirements | 10

INSTALLATION
WARNING! 220V cable connection must be carried out by a qualified electrician.
Mounting handles
Plug 220V (option 1) WAGO connector 220V 3×2.5mm (option 2)
1

2

3

11 | installation

FEATURES

Technical information

Parameters
Tank volume, l

Firetec 700
3,0

Firetec 800
3,7

Fireplace model

Firetec 1000

Firetec 1200

Firetec 1500

4,7

5,5

6,5

Firetec 2000
9,8

Firetec 2500
12,5

System volume, l

3,5

4,2

5,5

6,5

8,0

10,8

15,0

Consumption, I/h (min | max)
Average consumption, I/h (min | max)
Burning time, h (min | max)
Room size, m2 (with I without ventilation system)
Max power consumption, kW

0,35 | 0,8 0,4 | 1,0

0,6

0,7

3,8 | 8,6 3,7 | 9,3

22 | 54

27 | 68

0,55

0,55

0,6 | 1,4 0,66 | 1,5 0,9 | 2,0

1,0

1,1

1,5

3,4 | 7,8 3,7 | 8,3 3,3 | 7,2

38 | 95

41 | 102

54 | 136

0,9

0,9

1,0

1,2 | 2,5 1,9 | 4,5

1,9

3,2

3,9 | 8,2 2,8 | 6,6

68 | 170 122 | 306

1,4

1,8

Heat power, kW (min | max)
Air consumption, m3/h (min | max)
CO release, m3/h (min | max)

2,3 | 5,2 2,6 | 6,5 3,9 | 9,1 4,3 | 9,8 5,9 | 13,0 7,8 | 16,3 12,4 | 29,3

0,6 | 1,5 0,7 | 1,9

1,1 | 2,6

1,2 | 2,8

1,7 | 3,7

2,2 | 4,6 3,5 | 8,3

0,3 | 0,6 0,3 | 0,8 0,5 | 1,1 0,5 | 1,2 0,7 | 1,6 1,0 | 2,0 1,5 | 3,6

technical information | 12

Warnings

The manufacturer does not recommend placing objects that are sensitive to high temperatures above or next to the fireplace as this may significantly shorten their service lifetime.
In case the Technical Documentation and User Manual were not followed, the manufacturer would not be responsible for any damage to objects above or next to the fireplace.

ATTENTION! Kindly follow next rules while using the Neverdark fireplace:
Keep away from children; Ensure that the wall/table/floor on which you place the appliance can withstand its weight; Install in a place protected from draughts only; Do not cover top or side ventilation grids; Do not place flammable objects on the appliance; Keep a carbon dioxide fire extinguisher within sight; The use of a separate electricity line with a fuse and/or circuit breaker is mandatory; For comfortable use of the fireplace it is necessary to ensure the supply of a fresh air into the room, as well as removal of a cobustion products. It can be a ventilation extractor, recuperator or an opened window; Keep this Documentation in a safe place for the lifetime of the fireplace!

13 | warnings

NEVERDARK LLC
11 Kopernika St. Kyiv, Ukraine
neverdark.one

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)