PRIME LED LIGHT LS Series 5 Watt and 5 CCT Tunable LED Panel Light Installation Guide
- June 28, 2024
- PRIME LED LIGHT
Table of Contents
LS Series 5 Watt and 5 CCT Tunable LED Panel Light
“`html
Specifications:
-
Product: 5 Watts&5 CCT Tunable LED Panel Light
-
Features:
-
Both 5 Watts 5 CCT adjustable
-
Easy install by Recessed or surface mounts
-
Built-in junction box Fits standard T-grid ceilings
-
Optical lenses over LED chip, pc cover never yellow over
time -
50,000 hours Life time
-
DLC PREMIUM certified
-
-
Suitable Applications:
- Office Lighting
- Meeting room lighting
- Store lighting
- Restaurant lighting
Product Usage Instructions:
-
Installation & Mounting:
- Suspended Ceiling Mounting/ Frame Mounting
-
Performance:
-
Model NO: LS-PL22-M40W-CCT, LS-PL14-M40W-CCT,
LS-PL24-M72W-CCT -
Size: 2X2, 1X4, 2X4
-
Wattage: 15/20/25/30/40W, 30/40/50/60/72W
-
Voltage: 100-277V
-
Light Efficiency: 125LM/W
-
Kelvin Options: 3500K/4000K/5000K
-
-
Electric Characteristic:
- LED Driver: UL listed XIEZHEN Brand 0-10 dimmable
- Lumens output Efficiency: 125LM/W
- CRI: 80
- Color Temperature: 35/40/50/57/65K tunable
FAQ:
Q: What is the warranty on the product?
A: The product comes with a 5-year limited
warranty. Actual performance may differ based on the end-user
environment and application.
Q: What are the optional accessories available for this
product?
A: The optional accessory available is the
Emergency Battery Backup Style LSED20W.
Q: What are the suitable applications for this LED panel
light?
A: The suitable applications include office
lighting, meeting room lighting, store lighting, and restaurant
lighting.
“`
5 Watts&5 CCT Tunable LED Panel Light
Date: Product: Quantity:
Location: Project: Catalog#
FEATURES
Both 5 Watts 5CCT adjustable. Easy install by Recessed or surface mounts.
Built-in junction box Fits standard T-grid ceilings Optical lenses over LED
chip, pc cover never yellow over time. 50,000hours Life time. DLC PREMIUM
SUITABLE APPLICATIONS
Office Lighting Meeting room lighting Store lighting Restaurant lighting
CONSTRUCTION:
Quality white Aluminum heatsink and high transmission PC cover.
ELECTRICAL:
Available as 100-277V input. -25°C to45°C.
OPTICALSYSTEM:
High brightness SMD LED chips as backlit lighting solution.
INSTALLATION&MOUNTING:
Suspended Ceiling Mounting/ Frame Mounting
WARRANTY:
5-year limited warranty. Actual performance may differ as a result of end
-user environment and.application.
PERFORMANCE
Model NO
LS-PL22-M40W-CCT LS-PL14-M40W-CCT LS-PL24-M72W-CCT
SIZE
2X2 1X4 2X4
Wattage
Voltage
15/20/25/30/40W 15/20/25/30/40W 30/40/50/60/72W
100-277V 100-277V 100-277V
Light Efficiency
125LM/W 125LM/W 125LM/W
Kelvin Options
3500K/4000K/5000K 3500K/4000K/5000K 3500K/4000K/5000K
4940 Top Line Dr,Dallas,TX 75247 001-9729517795 www.ledsion.com
LS-PN-A.0 1 of 3
5 Watts&5 CCT Tunable LED Panel Light
LIGHTING
Electric Characteristic
Specification/Model LED Driver
Input powertunable Lumens output Efficiency CRI
Color Temperature Input voltage
Light distribution type Working temperature Junction temperature
lamps efficiency Certificate Equivalent
LS-PL22-M40W-CCT
LS-PL14-M40W-CCT
LS-PL24-M72W-CCT
15/20/25/30/40W
UL listed XIEZHEN Brand 0-10 dimmable 15/20/25/30/40W
30/40/50/60/72W
1875/2500/3125/3750/5000LM 125LM/W
1875/2500/3125/3750/5000LM 125LM/W
3750/5000/6250/7500/9000LM 125LM/W
80
80
80
35/40/50/57/65K tuna ble 120-277V/AC 110D
35/40/50/57/65Ktunable 120-277V/AC 110D
35/40/50/57/65K tunable 120-277V/AC 110D
-25+45 75
-25+45 75
-25+45 75
90% ETL DLC 36-110W MH/HPS
90% ETLDLC 36-110W MH/HPS
90% ETL DLC 56-150W MH/HPS
Electric Characteristic
OPTIONAL ACCESSORIES
1.61″
23.7″
23.7″
Emergency Battery Backup.Style LSED20W
1.61″
1.61″
47.7″
11.9″
23.7″
4940 Top Line Dr,Dallas,TX 75247 001-9729517795 www.ledsion.com
47.7″
LS-PN-A.0 2 of 3
5 Watts&5 CCT Tunable LED Panel Light
DISTRIBUTION DIAGRAM
LIGHTING
300 600 900 1200 1500
AVERAGE BEAM ANGLE(50%): 110°
Test Number:XL-PLU22M38XX-AZZ-A Lumens:2250LM Test Number:18W Test Number:5000K
UNIT:CD C0/180,110.9 C30/210,110.5 C60/240,109.3. C90/270,109.1
300 600 900 1200 1500
AVERAGE BEAM ANGLE(50%): 110°
Test Number:XL-PLU22M38XX-AZZ-A Lumens:3500LM Test Number:28W Test Number:5000K
UNIT:CD C0/180,110.9 C30/210,110.5 C60/240,109.3. C90/270,109.1
400 800 1200 1600 2000
AVERAGE BEAM ANGLE(50%): 110°
– Test Number:XL-PLU24M48XX-AZZ A
Lumens:6000LM
Test Number:48W
Test Number:5000K
UNIT:CD C0/180,110.9 C30/210,110.5 C60/240,109.3. C90/270,109.1
Install instruction
STEP 1: Remove boards as drawing
STEP 2:Put the lamp on the ceiling
STEP 3:Open the cover of junction box with tool knock off the piece of top Install serpentire coil in junction box
T-bar clips should be bent out to provide additional safety and support.
STEP 4: Connnect wires with P2 P3 nuts Refer the wiring diagram
STEP 5:Lock the lamp on frameworks
5187 Shadowlawn Ave suite: 103 Tampa FL 33610 www.primeledligth.com
STEP 6: Put the board back; and check again
LS-PN-A.0 3 of 3
Read User Manual Online (PDF format)