SIMO CYD-008S Solis Go Kiosk Owner’s Manual

June 27, 2024
SIMO

ShenZhen Huaxinwei Technology CO. ,LTD


Technical specification of Shared charging treasure

Cabinet Shared charging kit specification

Name:           SOLIS GO Kiosk
Model:          CYD-008S CYD-012S CYD-016S
Author:          JuFen Lee
Review:          York Zhen
Approval:       Wayne Qiu
Date:              2024-05-10

change record
version number content of change Author change date
V1.0  initial version JuFen Li 2024-5-10
Copyright notice

Copyright © shenzhen huaxinwei technology co., LTD. All rights reserved. ShenZhen Huaxinwei technology co., LTD. Reserves all rights. Without the written consent of shenzhen huaxinwei technology co., LTD., no unit or individual shall extract or copy part or all of this document without authorization, and shall not disseminate it in any form.

Explain

The corresponding product in this specification is CYD-008S12S16S cabinet type Shared charging treasure. Due to product version upgrade or other reasons, the contents of this specification will be updated as necessary without prior notice.

Unless otherwise agreed, all statements, information and recommendations in this specification do not constitute any warranty, express or implied.

ShenZhen Huaxinwei technology co., LTD. To provide customers with a full range of technical support. For any enquiry, please contact your account manager directly.

1 Summarize

This specification applies to the company produced CYD-008S12S16S cabinet Shared charging treasure products, this product can be connected through the Internet of backend server, through the background charging treasure to pay loan function, this product can support apple, Micro, Type – C this three standard interface of mobile phone, tablet and other communication devices, and other USES of the three kinds of standard interface 5 v input of charging electronic products.

2 Executive standard
  • Cabinet implementation standard: GB 4943.1-2011 equipment security in information technology part I: general requirements
  • Implementation standard of charging battery: GB/T 35590-2017 general specification for mobile power supply for information technology portable digital devices
  • Safety requirements for lithium ion batteries and battery packs for portable electronic products
  • Gb5023-1997 polyvinyl chloride insulated cables with rated voltage up to and including 450/750
  • GSM/GPRS/EDGE 4G communication protocol
3 Main components
  • CYD-008S12S16S (SOLIS GO Kiosk) Shared charging cabinet ………………….. 1pc
  • SGO24 power bank …………………………. 8\12\16pcs
  • 4G traffic card (including domestic 30M monthly 4G network traffic for 1 year) ………. 1pc
  • Power cord …………………….. 1pc
  • CYD-008S:DC 12V-5.0A (MAX), CYD-012S\16S:DC 12V-10.0A (MAX) Adapter CYD-008S:DC 12V-5.0A (MAX),  CYD-012S16S:DC 12V-10.0A (MAX) ……………….. 1pc
4 Cabinet basic parameters
  • mains input: AC 220V ~ 50/60Hz 1.3A
  • Total power output: CYD-008S:DC 12V-5.0A (MAX) CYD-012S\16S:DC 12V-10.0A (MAX)
  • Single power output: DC 5V-2.0A (MAX)
  • USB output: DC5V-2.0A (MAX)
  • Advertising Screen 10.1 inches DC12V-0.3A (MAX)
  • Length of power cord: 1.2m
  • network support: 4G network
  • operating ambient temperature: 0~50°C
  • Working environment humidity: 25~75%
  • Power protection: overcurrent protection, overvoltage protection, short circuit protection
5 Basic parameters of the charger
  • Charging input: DC 5V-2.0A (MAX)
  • Terminal stylus charging input: DC 5V-2.0A (MAX)
  • output (IOS, Type-C): DC 5V-1.0A (MAX)
  • Batteries specifications: 8000mAh
  • 80% Energy conversion efficiency: 80%
  • 85% Cell cycle life: no less than 85% for 300 cycles
  • 0%-100% Charging time: 4.5-5 hours
  • Protective functions of protection plate: over temperature protection, over charge protection, over discharge protection, over current protection, over voltage protection, short circuit protection.
  • Boot output: insert the corresponding interface into the adaptor phone, open the button, and start the output.
  • Power indicator: less than 30% pink light flash, 30% -60% blue light flash, 60% -100% green light flash.
6 Cell safety performance
project Test article  performance requirement
intersection detection The standard charging cell is fixed on the shaking

table and vibrates for 30 minutes along the directions of X, Y and Z. The amplitude is 1.6mm, and the vibration frequency is 10Hz~55Hz, with a change of 1Hz per minute.| The appearance of the battery shall be free from obvious damage and shall not break, leak, smoke or explode.
Free fall| After the charging is finished according to the regulation, the sample of mobile power is put on hold for 0.5h ~ 1h, and it falls freely on the concrete slab from the height (the lowest height) of 1000mm, and falls one time from X, Y, Z positive and negative directions (six directions).After the test, measure the output voltage and make the final test. During the free fall test, there shall be no explosion, no deflation, no fire, no leakage, or rupture causing safety hazard. After the test, the mobile power supply shall work normally according to the functions specified in the manual, and the measured output voltage shall be within the range of Uout±5% deviation.| Batteries should not leak, smoke, catch fire or explode.
Constant temperature and humidity properties| After the battery was fully charged, the battery was put into a constant temperature and humidity box with 40 ° c ±2 ° c and a relative humidity of 90%-95%, and then set aside for 48h. After the experiment, the battery was set aside for 2h at an ambient temperature of 20 ° c ±5 ° c to visually test the battery appearance. A constant discharge of 1C is applied to the termination voltage of 2.75v.| The appearance of the battery shall be free from obvious deformation, corrosion, smoke or explosion, and the battery discharge time shall be ≥45min
cryogenic property| After the battery is fully charged, the battery is put into a low-temperature box with a constant temperature of -10℃±2℃ for 16h-24h and discharged at 0.2c current to the termination voltage of 2.75v.After the experiment, the battery was put in the environment temperature of 20℃±5℃ for 2h, and the appearance of the battery was visually tested. | The appearance of the battery shall be free from deformation, smoke or explosion, and the battery discharge time shall be >45min
Flame retardant materials| The housing, printed board and insulating material of the mobile power supply shall be carried out in accordance with gb4943.1-2011 or its substitute standard or the corresponding test method in GB 31241.The flame retardant grade of the housing, printed board and insulating material of the portable power supply shall not be lower than the v-1 level flame retardant requirement| After the second application of the flame according to the standard GB 4943.1-2011, the burning time of the cigarette butt shall not exceed 60s

7 Test environment conditions

Unless otherwise specified, the tests in this specification shall be carried out under standard atmospheric conditions. Temperature: 23±2 ambient temperature. Relative humidity: 45%~75%. Atmospheric pressure: 86 kPA~106 kPA.

8 Measuring instruments and testing requirements

Voltage meter accuracy should be not less than 0.5 on the Richter scale, resistance shall be not less than 10 k/V. The instrument accuracy of measuring current shall not be lower than 0.5 level.The constant current load is adjustable with constant current within the voltage range of the power supply under test, and its current relative error is 0.1%.

9 Finished dimensions

Schematic diagram of cabinet dimensions:

Schematic diagram of dianbao size:

10 packing information
  • Cabinet net weight: CYD-008S: 3.90kg CYD-012S:4.55kg CYD-016S:5.73kg
  • Charge treasure net weight: 0.180kg
  • carton size: 290250500mm290250600mm290250700mm
  • Packing diagram:
11 Warranty period and product liability
  • The warranty period is calculated from the date of delivery. The warranty period of the cabinet is 12 months, and the warranty period of the charger is 6 months.
  • Shenzhen Huaxinwei technology co., LTD. Shall not be responsible for any accident caused by failure to operate in accordance with this specification.
12 Matters need attention

(1) Reverse charging is not acceptable.
(2) Do not charge/discharge with more than our specified current.
(3) Do not short circuit the cell/battery Permanent damage to the cell/battery may result.
(4) Do not incinerate or mutilate the cell/battery.
(5) Do not solder directly to the cell/battery.
(6) The life expectancy may be reduced if the cell/battery is subjected adverse conditions like: extreme temperature, deep cycling, excessive overcharge/ over-discharge.
(7) Do not put the battery into high temperature environment, liquid, corrosive places
(8) Manual disassembly is prohibited
(9) If the charger has not been used for more than three months, please insert the charger into the cabinet to recharge once

CE Warning
  1. Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions.
  2. The product shall only be connected to a USB interface of version USB2.0 or higher.
  3. Adapter shall be installed near the equipment and shall be easily accessible.
  4. The operating temperature of the device can’t exceed 50°C and shouldn’t be lower than 0°C.
  5. The plug considered as disconnect device of adapter.

Hereby, Simo Holdings Inc. declares that this product is in compliance with essential requirements and other relevant provisions of Directive 2014/53/EU. This product is allowed to be used in all EU member states.

Frequency Band(s)

This device operates with the following frequency bands and maximum frequency power.
NOTE:
The product is compliant with these power limits required by the European Union. Frequency bands supported by the product vary by model.
EGSM900: 35dBm
DCS1800: 32dBm
WCDMA B1/B8: 25dBm
LTE Band 1/3/7/8/20/28/38/40: 25dBm
2.4G WIFI: <20dBm

FCC Warning

15.19 Labeling requirements.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
15.21 Information to user.
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
15.105 Information to the user.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.


© Copyright ©ShenZhen Huaxinwei technology co., LTD. All rights reserved

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals