FILTRINOV FB12 Self Contained Single Piece Filtration Unit Instruction Manual
- June 16, 2024
- FILTRINOV
Table of Contents
- FILTRINOV FB12 Self-Contained Single Piece Filtration Unit
- Product Usage Instructions
- TECHNICAL DESCRIPTION OF THE FILTRATION UNIT
- INSTALLING THE FILTRATION UNIT
- FILTRATION UNIT POWER SUPPLY
- LED LIGHT
- SETTING THE TIMER
- POOL-EARTH / FUNCTIONAL EARTH
- OPTIONAL BY-PASS (3-way valve)
- TROUBLESHOOTING
- LIGHTING
- Documents / Resources
FILTRINOV FB12 Self-Contained Single Piece Filtration Unit
Specifications
- Product Name : FB 12 Filtration Unit
- Type: Self-contained single-piece filtration unit
- Voltage: 230 Volts AC
- Filtration Capacity : Dual filter cartridge housing incl. 2 leaf baskets
- Features: Multi-directional, high-flow nozzle, LED light (optional), Two suction skimmers
Product Usage Instructions
Installing the Filtration Unit
Follow the installation instructions provided in the manual. Ensure proper drainage around the pool leading to a relief well with a basement sump pump.
Technical Description of the Filtration Unit
The filtration unit consists of in-ground and submerged sections. Key components include a filter pump, control panel, leaf baskets, filter cartridges, skimmers, and optional LED light.
Filtration Unit Power Supply
Make sure to connect the unit to a power supply of 230V 50-60Hz. Use a 30mA differential protection system and a C16 thermal magnetic circuit breaker for safety.
LED Light
Your unit may come with a standard white LED light. Optional multicolour LED lights with various color options and sequence programs are also available.
Setting the Timer
Follow the sequencing principle of minimum 1 hour of downtime after 4 hours of operation. Refer to the attached instructions for setting the timer.
Starting the Filtration Unit
When the water level reaches the skimmers, start the filtration unit:
- Prime the pump by filling it with water.
- Screw in the Pool earth.
- Switch the filtration unit to manual mode to start the pump.
It is recommended to remove the drain plug after installation.
FAQ
- Q: Do I need to test the residual current device manually?
- A: Yes, it is essential to manually test the residual current device (maximum 30 mA) as a safety measure for cutting power to pool appliances.
- Q: What should I do if the LED light malfunctions?
- A: Refer to the manufacturer’s guide for troubleshooting steps related to the LED light functionality.
Installation and operating instructions.
Please read it carefully and retain for future reference.
RECOMMENDATIONS
- TO PREVENT WATER INGRESS INTO THE NON-WATERTIGHT TANK OF THE FB UNIT WE ADVISE YOU TO INSTALL A DRAIN ALL AROUND THE POOL THAT RUNS INTO A RELIEF WELL CONTAINING A BASEMENT SUMP PUMP.
- CLEAN BOTH CARTRIDGES AT REGULAR INTERVALS
- ALWAYS LOCK THE LID SHUT AFTER COMPLETING MAINTENANCE WORK IN THE TANK
- DO NOT USE FLOCCULANTS OR «MULTIFUNCTIONAL» CHLORINE
These installation instructions are an integral part of the product and must be given to the user. This booklet should be retained for reference.
- Check the condition of the contents after unpacking the filtration unit.
- Before wiring up the unit, make sure the manufacturer’s data is compatible with the planned system and does not exceed the maximum permitted limits of the particular item.
- Always cut the electrical power from the main consumer unit before carrying out any maintenance, handling or repair work.
Any repair work must be carried out by an authorised technical support service using only OEM spare parts. Failure to comply with the above requirements may cause unsafe operation of the filtration unit and will void the manufacturer’s warranty. A high-sensitivity, 30 mA cut-off device must be fitted at the head end.
TERMS AND CONDITIONS OF DELIVERY :
All items, including when sold postage and packing paid, are transported at
the consignee’s risk. The consignee must record any reservations regarding
damage in transit in writing on the CARRIER’S delivery note and provide
confirmation thereof within 48 hours by registered letter sent to the CARRIER.
VOLTAGE : before operating, check that the appliance voltage indicated on
the data plate is the same as the mains voltage (usually 230 Volts AC).
FOREWORD :
Thank you for purchasing this FB 12 filtration unit and for your trust in our
company. You can rest assured that every effort has been and will continue to
be made to bring you complete satisfaction. This product has been carefully
designed with your safety in mind. Your new filtration unit comes with the
same features as a traditional filtration system.
Reminder : a residual current device (maximum 30 mA) must be fitted
upstream, and manually tested, as a safety measure to cut the low-voltage
power to pool appliances.
TECHNICAL DESCRIPTION OF THE FILTRATION UNIT
- Filter access lid.
- Multi-directional, high-flow nozzle.
- LED light (optional)
- Dual filter cartridge housing incl. 2 leaf baskets.
- Two suction skimmers.
- The in-ground section containing:
- Pumps
- Control panel (if light fitted)
- Removable, lockable lid.
IN-GROUND SECTION
- Filter pump
- Control panel (optional)
- Pool light transformer (optional)
- Remote control unit
SUBMERGED SECTION
- 2 Leaf baskets
- 2 Filter cartridges
- 2 Skimmers
INSTALLING THE FILTRATION UNIT
- Dig a pit into which the filtration unit tank will be placed.
- Remove the filtration unit from its packaging and place it carefully in position straddling and resting on the pool structure.
- Make sure the front, pool-side of the unit is positioned fully perpendicular to the pool wall.
- Feed in the electrical wiring and then fill in the pit with gravel all around the filtration unit tank.
FILTRATION UNIT POWER SUPPLY
The filtration unit should be connected to an insulated electricity supply running directly from the main consumer unit with a 16A fuse or circuit breaker, protected by a 30mA RCD (not included). Use a 3-wire cord, earth- live-neutral, with a 1.5 or 2.5 mm² section if less than 30 linear meters.
FB with light
LED LIGHT
Your filtration unit may include a white LED light as standard.
A MULTICOLOUR LED light option is also available in 11 non-animated colors
incl. white and with 5 sequence programs (remote control included)
(Manufacturer’s guide included)
SETTING THE TIMER
Continuous mode
( 24-hour filtration) Move the filter switch on the outside of the electrical panel to «Manual».
Auto mode (timed filter operation)
Move the filter switch on the outside of the electrical panel to
«Automatic».
Turn the clock hands to set the exact time relative to the pointer (triangle)
on the right of the clock.
Push the segments outwards to set the scheduled «On» times.
Sequencing principle:
Minimum 1 h of downtime after 4 h of operation.
See the instructions attached to the panel
STARTING THE FILTRATION UNIT
When the water in your pool is at of the level of the skimmers, operate the filtration unit for the first time as follows :
- Prime the pump by filling it with water through the hole provided
- Screw in the Pool earth
- Put the filtration unit in manual mode to start the pump
You are strongly advised to unscrew and remove the drain plug from the tank when you have finished installing the filtration unit.
Repeat the above steps if the priming procedure is not working after 2 minutes.
POOL-EARTH / FUNCTIONAL EARTH
It is vital that the pool be earthed in order to remove stray currents from
the water. Stray currents are not dangerous to people, but they do electrolyze
the metal components in the pool, which increases corrosion. Theycan also
disrupt the treatment probes, resulting in incorrect amounts of product being
injected.
This is why FILTRINOV has included a pool earth with these products. Screw it
into the threaded attachment point provided and connect it to the earth rod
with a Ø 6 mm copper braid earth strap (parts not included).
A hole will have to be drilled in the tank to route the braid through the
packing gland provided.
FILTRATION: OPERATING PRINCIPLE
Water from the surface of the pool is drawn in by the skimmers and sent through the filter cartridges, where it is cleaned. It then travels on to the pump, which discharges it through the return nozzle back into the pool.
The filter cartridges must be washed every few complete filtration cycles.
The cartridge should be cleaned at least once a week and whenever the suction cleaner has been used. To clean the cartridge, remove the basket, lift out the cartridge and gently hose it down. Refit the cartridge once it is clean.
Your FB includes a cartridge housing at the bottom of the filter holder to fit the cartridge. Turn the cartridge a quarter turn downwards to slot it into place in the filter holder. Remember to fit the basket and its pre-filter.
All FILTRINOV filtration units are checked and tested with the utmost care and subject to FILTRINOV’S stringent quality controls.
The use of non FILTRINOV-approved parts and consumable items shall render the pump and hydraulic system warranty void.
EASY FILTER bags and cartridges are not approved by FILTRINOV. Persistent clogging and risk of permanent damage to the pump.
The filtration time should be increased as the water temperature rises :
- 12° to 16° = 6 hours
- 16° to 24° = 8 hours
- 24° to 27° = 10 hours
- 27° to 30° = 12 to 14 hours or more
Sequencing principle : Minimum 1 h of downtime after 4h of operation.
VACUUM POINT FOR MANUAL SUCTION CLEANER OR 10 HYDRAULIC AUTOMATIC CLEANER
- Connect one end of the hose to the suction cleaner
- Hold the suction cleaner by the handle and insert it into the pool,
- Gradually insert the hose into the water until the water pushes out the air (tip : you can fill the hose with water by placing its tip in front of the return nozzle with the unit running) ;
- Feed the other end of the hose into the skimmer mouth and attach it to the skim vac plate that seals off the basket ;
- Place the other (plugged) skim vac over the other basket in order to block suction from the second skimmer and maintain best cleaning performance ;
- Only use when using the suction cleaner
The cartridges should be cleaned at least once a week and whenever the suction cleaner has been used. To clean the cartridges, remove the baskets, lift out the cartridges and gently hose them down. Refit the clean cartridges and the baskets.
OPTIONAL BY-PASS (3-way valve)
The by-pass consists of a 3-way valve and a branch Tee. You are advised to
seal the pipe entries in order to prevent water from getting into the tank.
Your heat pump is connected to the filtration unit by a Ø 50 PVC pipe.
- Place the 2 shutoff valves at the inlet and outlet of the heat pump so that it can be isolated during winter storage.
WINTERISING & PUMP DISASSEMBLY
Active Winterising
An actively winterized pool continues to operate at a slower-than-normal rate throughout the wintertime. This is the recommended winterizing procedure in less cold regions. If you live in a harsher winter climate, you should choose to passively winterize your pool instead.
- First clean the pool structure, the water line, baskets, and cartridges.
- Next, shock the pool with chlorine.
- Run the filtration system non-stop for at least 12 hours.
- Then reset your timer to run the filtration system for 30 minutes every 3 hours (do not be afraid to increase the running time if the temperature is significantly below zero).
- Your pool will not require any more product treatments for the whole winter. Just monitor the water’s pH level and adjust if necessary.
- Check and clean the baskets and cartridges at regular intervals.
- We also recommend that you use winter floats in your pool.
- You can also cover your pool with a winter cover or tarp, although this is not mandatory.
Passive winterizing and pump disassembly
Passive winterizing involves shutting down the filtration unit entirely.
- First clean the whole of the pool and its equipment (floor and walls, water line, baskets, cartridges, etc).
- Check the water’s pH level and adjust if necessary.
- Shock the pool with a chlorine treatment.
- Run the filtration system non-stop for at least 12 hours.
- Protect the filtration system from frost.
TROUBLESHOOTING
FILTERS/PUMPS/CCS
PROBLEM: Low-pressure flow and/or air bubbles in the pumped water flow
PROBLEM: The pump does not start
If there is no noise :
If the power unit is making a noise :
PROBLEM : The pump cuts out and starts up again later
LIGHTING
PROBLEM: The pool light does not come on.
PROBLEM : The light is blinking.
Documents / Resources
|
FILTRINOV FB12 Self Contained Single Piece Filtration
Unit
[pdf] Instruction Manual
FB12, FB12 Self Contained Single Piece Filtration Unit, Self Contained Single
Piece Filtration Unit, Single Piece Filtration Unit, Piece Filtration Unit,
Filtration Unit, Unit
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>