SOLEUSAIR WS5-08HW-301 Electronic Hybrid Air Conditioner With Heat Instruction Manual
- June 14, 2024
- SoleusAir
Table of Contents
- WS5-08HW-301 Electronic Hybrid Air Conditioner With Heat
- Product Specifications:
- Product Usage Instructions:
- Pre-Operation Guidelines:
- Purchase Information:
- Important Instructions:
- Q: Can the fuse be replaced?
- Q: Is the appliance safe for children to operate?
- Q: What should I do if the supply cord is damaged?
WS5-08HW-301 Electronic Hybrid Air Conditioner With Heat
“`html
Product Specifications:
- Model Numbers: WS5-08HW-301, WS5-10HW-301, WS5-12HW-301
- Cooling Capacities: 8,000 BTU, 10,000 BTU, 12,000 BTU
- Type: Electronic Hybrid Air Conditioner with Heat
Product Usage Instructions:
Pre-Operation Guidelines:
Air conditioner must be kept upright for 24 hours before
operation to ensure proper compressor functionality.
Purchase Information:
Thank you for choosing a Soleus Air Hybrid Air Conditioner. This
manual provides essential care and maintenance information. Attach
a copy of your sales receipt to the manual and note down store
details and purchase date.
Important Instructions:
Before installation and use, carefully read and store this
manual for future reference. Safety is paramount; follow all safety
guidelines provided.
Safety Precautions:
-
Follow basic precautions to reduce fire, electrical shock, or
injury risks. -
Pay attention to safety alert symbols (DANGER or WARNING).
-
Failure to follow instructions may lead to serious injury or
death.
Caution Symbols Explanation:
-
Symbol with Flammable Refrigerant: Risk of fire if leaked and
exposed to ignition source. -
Symbol for Reading Operation Manual Carefully.
-
Symbol for Service Personnel Handling Equipment.
-
Symbol for Available Information in Manuals.
Additional Safety Instructions:
-
Appliance not for use by individuals with reduced capabilities
unless supervised. -
Supervise children to prevent playing with the appliance.
-
If supply cord is damaged, replace by manufacturer or qualified
persons.
FAQ:
Q: Can the fuse be replaced?
A: The fuse cannot be replaced as per product guidelines.
Q: Is the appliance safe for children to operate?
A: The appliance is not intended for use by individuals with
reduced capabilities unless supervised. Children should be
monitored to prevent misuse.
Q: What should I do if the supply cord is damaged?
A: If the supply cord is damaged, it must be replaced by the
manufacturer or qualified persons to avoid hazards.
“`
Model WS5-08HW-301 WS5-10HW-301 WS5-12HW-301
8,000 BTU 10,000 BTU 12,000 BTU
Electronic Hybrid Air Conditioner w/ Heat Operating Instructions
5028773
Air conditioner must be upright for 24 hours prior to operating.
This ensures that the compressor will function as intended.
V240113
PURCHASE INFORMATION
Thank you for choosing a Soleus Air Hybrid Air Conditioner. This Owner’s
Manual will provide you with valuable information necessary for the proper
care and maintenance of your new product. Please take a few moments to
thoroughly read the instructions and familiarize yourself with all the
operational aspects of your new Soleus Air Window Air Conditioner.
For your own records, please attach a copy of your sales receipt to this
manual. Also, write the store name/location, date purchased, and serial number
below: Store Name: ____
Location: ____ Date
Purchased: Serial Number
(located on back of unit): __
IMPORTANT INSTRUCTIONS
Before installing and using your air conditioner, please read this owner ‘s manual carefully. Store this manual in a safe place for future reference. Your safety and the safety of others is very important to us. Please pay attention to all safety messages outlined in this owner’s manual.
WARNING: To reduce the risk of fire, electrical shock or injury when using your air conditioner, follow these basic precautions:
· Plug into a grounded 3 prong outlet. · Do not remove the ground prong. · Do not use a plug adapter.
· Do not use an extension cord. · Unplug the air conditioner before servicing.
· Use two or more people to move and install the air
conditioner.
This is a safety alert symbol. This symbol alerts you to potential hazards
that can harm you or others or even cause death. All safety messages will
directly follow the safety alert symbol and/or the words “DANGER” or
“WARNING.”
All Safety messages alert you of potential hazards, how to reduce the chance
of injury, and what can happen if instructions are not followed correctly.
Failure to immediately follow these instructions may cause serious injury or
even death.
IMPORTANT INSTRUCTIONS
WARNING
THIS SYMBOL THAT THIS APPLIANCE USED A FLAMMABLE REFRIGERANT. IF THE REFRIGERANT IS LEAKED AND EXPOSED TO AN EXTERNALIGNITION SOURCE.THERE IS A RISK OF FIRE.
CAUTION CAUTION CAUTION
THIS SYMBOL THAT THE OPERATION MANUAL SHOULD BE READ CAREFULLY.
THIS SYMBOL THAT A SERVICE PERSONNEL SHOULD BE HANDLINGTHIS EQUIPMENT WITH
REFERENCE TO THE INSTALLATION MANUAL.
THIS SYMBOL THAT INFORMATION IS AVAILABLE SUCH AS THE OPERATING VANUAL OR
INSTALLATION MANUAL.
The fuse cannot be replaced.
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the
appliance.
If the SUPPLY CORD is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
A statement requiring that a damaged cord be replaced with one supplied by the
unit manufacture and not repaired.
WARNING – RISK OF ELECTRIC SHOCK. CAN CAUSE INJURY OR DEATH. DISCONNECT All
REMOTE ELECTRIC POWER SUPPLIES BEFORE SERVICING.
WARNING – Risk Of Fire. Flammable Refrigerant Used. To Be Repaired Only By
Trained Service Personnel. Do Not Puncture Refrigerant Tubing.
WARNING – Risk Of Fire. Dispose Of Properly In Accordance With Federal Or
Local Regulations. Flammable Refrigerant Used.
IMPORTANT INSTRUCTIONS
WARNING – Risk Of Fire. Flammable Refrigerant Used. Consult Repair
Manual/Owner’s Guide Before Attempting To Service This Product. All Safety
Precautions Must Be Followed.
WARNING – Risk of Fire due to Flammable Refrigerant Used. Follow Handling
Instructions Carefully in Compliance with National Regulations.
Warning: keep any required ventilation openings clear of obstruction.
Notice: servicing shall be performed only as recommended by the manufacturer.
Warning: The appliance shall be stored in a well-ventilated area where the
room size corresponds to the room area as specified for operation.
Warning: The appliance shall be stored in a room without continuously
operating open flames (for example an operating gas appliance) and ignition
sources (for example an operating electric heater).
WARNING Y Do not use means to accelerate the defrosting process or to clean,
other than those recommended by the
manufacturer. Y The appliance shall be stored in a room without continuously
operating ignition sources. (for example: open
flames, an operating gas appliance or an operating electric heater.) Y Do not
pierce or burn. Be aware that refrigerants may not contain an odour.
QUALIFICATION OF WORKERS The installation and servicing of this equipment must
be performed by qualified, experienced technicians only. Professional
installation personnel should have the following experience: Y Installing the
electric heater. Y Opening of sealed components. Y Opening of ventilated
enclosures. Y Commissioning and troubleshooting. Y Checking the electric
control part and wiring. Y Breaking into the refrigerant circuit and charging.
Information on servicing 1) Checks to the area Prior to beginning work on
systems containing FLAMMABLE REFRIGERANTS, safety checks are necessary to
ensure that the risk of ignition is minimised. For repair to the REFRIGERATING
SYSTEM.
2)Work procedure Work shall be undertaken under a controlled procedure so as
to minimise the risk of a flammable gas or vapour being present while the work
is being performed.
3)General work area All maintenance staff and others working in the local area
shall be instructed on the nature of work being carried out. Work in confined
spaces shall be avoided.
IMPORTANT INSTRUCTIONS
4)Checking for presence of refrigerant The area shall be checked with an
appropriate refrigerant detector prior to and during work, to ensure the
technician is aware of potentially toxic or flammable atmospheres. Ensure that
the leak detection equipment being used is suitable for use with all
applicable refrigerants, i. e. non-sparking, adequately sealed or
intrinsically safe.
5)Presence of fire extinguisher If any hot work is to be conducted on the
refrigerating equipment or any associated parts, appropriate fire
extinguishing equipment shall be available to hand. Have a dry powder or CO2
fire extinguisher adjacent to the charging area.
6)No ignition sources No person carrying out work in relation to a
REFRIGERATING SYSTEM which involves exposing any pipe work shall use any
sources of ignition in such a manner that it may lead to the risk of fire or
explosion. All possible ignition sources, including cigarette smoking, should
be kept sufficiently far away from the site of installation, repairing,
removing and disposal, during which refrigerant can possibly be released to
the surrounding space. Prior to work taking place, the area around the
equipment is to be surveyed to make sure that there are no flammable hazards
or ignition risks. “No Smoking” signs shall be displayed.
7)Ventilated area Ensure that the area is in the open or that it is adequately
ventilated before breaking into the system or conducting any hot work. A
degree of ventilation shall continue during the period that the work is
carried out. The ventilation should safely disperse any released refrigerant
and preferably expel it externally into the atmosphere.
8)Checks to the refrigerating equipment Where electrical components are being
changed, they shall be fit for the purpose and to the correct specification.
At all times the manufacturer’s maintenance and service guidelines shall be
followed. If in doubt, consult the manufacturer’s technical department for
assistance. The following checks shall be applied to installations using
FLAMMABLE REFRIGERANTS: Y the actual REFRIGERANT CHARGE is in accordance with
the room size within which the refrigerant
containing parts are installed; Y the ventilation machinery and outlets are
operating adequately and are not obstructed; Y if an indirect refrigerating
circuit is being used, the secondary circuit shall be checked for the presence
of
refrigerant; Y marking to the equipment continues to be visible and legible.
Markings and signs that are illegible shall be
corrected; Y refrigerating pipe or components are installed in a position
where they are unlikely to be exposed to any
substance which may corrode refrigerant containing components, unless the
components are constructed of materials which are inherently resistant to
being corroded or are suitably protected against being so corroded.
9)Checks to electrical devices Repair and maintenance to electrical components
shall include initial safety checks and component inspection procedures. If a
fault exists that could compromise safety, then no electrical supply shall be
connected to the circuit until it is satisfactorily dealt with. If the fault
cannot be corrected immediately but it is necessary to continue operation, an
adequate temporary solution shall be used. This shall be reported to the owner
of the equipment so all parties are advised.
IMPORTANT INSTRUCTIONS
Initial safety checks shall include: Y that capacitors are discharged: this
shall be done in a safe manner to avoid possibility of sparking; Y that no
live electrical components and wiring are exposed while charging, recovering
or purging the system; Y that there is continuity of earth bonding.
Repairs to sealed components Y During repairs to sealed components, all
electrical supplies shall be disconnected from the equipment being
worked upon prior to any removal of sealed covers, etc. If it is absolutely
necessary to have an electrical supply to equipment during servicing, then a
permanently operating form of leak detection shall be located at the most
critical point to warn of a potentially hazardous situation. Y Particular
attention shall be paid to the following to ensure that by working on
electrical. Y components, the casing is not altered in such a way that the
level of protection is affected. This shall include damage to cables,
excessive number of connections, terminals not made to original specification,
damage to seals, incorrect fitting of glands, etc. Y Ensure that the apparatus
is mounted securely. Y Ensure that seals or sealing materials have not
degraded to the point that they no longer serve the purpose of preventing the
ingress of flammable atmospheres. Replacement parts shall be in accordance
with the manufacturer’s specifications.
Repair to intrinsically safe components Y Do not apply any permanent inductive
or capacitance loads to the circuit without ensuring that this will not
exceed the permissible voltage and current permitted for the equipment in use.
Y Intrinsically safe components are the only types that can be worked on while
live in the presence of a
flammable atmosphere. The test apparatus shall be at the correct rating. Y
Replace components only with parts specified by the manufacturer. Other parts
may result in the ignition of
refrigerant in the atmosphere from a leak. Y NOTE The use of silicon sealant
can inhibit the effectiveness of some types of leak detection equipment.
Intrinsically safe components do not have to be isolated prior to working on
them.
Cabling Y Check that cabling will not be subject to wear, corrosion, excessive
pressure, vibration, sharp edges or any
other adverse environmental effects. The check shall also take into account
the effects of aging or continual vibration from sources such as compressors
or fans.
Detection of flammable refrigerants Y Under no circumstances shall potential
sources of ignition be used in the searching for or detection of
refrigerant leaks. A halide torch (or any other detector using a naked flame)
shall not be used. Y The following leak detection methods are deemed
acceptable for all refrigerant systems. Y Electronic leak detectors may be
used to detect refrigerant leaks but, in the case of FLAMMABLE
REFRIGERANTS, the sensitivity may not be adequate, or may need re-calibration.
(Detection equipment shall be calibrated in a refrigerant-free area.) Ensure
that the detector is not a potential source of ignition and is suitable for
the refrigerant used. Leak detection equipment shall be set at a percentage of
the LFL of the refrigerant and shall be calibrated to the refrigerant
employed, and the appropriate percentage of gas (25% maximum) is confirmed. Y
Leak detection fluids are also suitable for use with most refrigerants but the
use of detergents containing chlorine shall be avoided as the chlorine may
react with the refrigerant and corrode the copper pipe-work.
IMPORTANT INSTRUCTIONS
Y NOTE Examples of leak detection fluids are bubble method, fluorescent
method agents.
Y If a leak is suspected, all naked flames shall be removed/extinguished. Y If
a leakage of refrigerant is found which requires brazing, all of the
refrigerant shall be recovered from the
system, or isolated (by means of shut off valves) in a part of the system
remote from the leak.
Removal and evacuation When breaking into the refrigerant circuit to make
repairs or for any other purpose conventional procedures shall be used.
However, for flammable refrigerants it is important that best practice be
followed, since flammability is a consideration. Y The following procedure
shall be adhered to:
a) safely remove refrigerant following local and national regulations; b)
purge the circuit with inert gas; c) evacuate (optional for A2L); d) purge
with inert gas (optional for A2L); e) open the circuit by cutting or brazing.
Y The refrigerant charge shall be recovered into the correct recovery
cylinders if venting is not allowed by local and national codes. For
appliances containing flammable refrigerants,the system shall be purged with
oxygen-free nitrogen to render the appliance safe for flammable refrigerants.
This process might need to be repeated several times. Y Compressed air or
oxygen shall not be used for purging refrigerant systems. Y For appliances
containing flammable refrigerants, refrigerants purging shall be achieved by
breaking the vacuum in the system with oxygen-free nitrogen and continuing to
fill until the working pressure is achieved, then venting to atmosphere, and
finally pulling down to a vacuum (optional for A2L). This process shall be
repeated until no refrigerant is within the system (optional for A2L). When
the final oxygen-free nitrogen charge is used, the system shall be vented down
to atmospheric pressure to enable work to take place. Y Ensure that the outlet
for the vacuum pump is not close to any potential ignition sources and that
ventilation is available.
Charging procedures Y In addition to conventional charging procedures, the
following requirements shall be followed. Y Ensure that contamination of
different refrigerants does not occur when using charging equipment. Y Hoses
or lines shall be as short as possible to minimise the amount of refrigerant
contained in them. Y Cylinders shall be kept in an appropriate position
according to the instructions. Y Ensure that the REFRIGERATING SYSTEM is
earthed prior to charging the system with refrigerant. Y Label the system when
charging is complete (if not already). Y Extreme care shall be taken not to
overfill the REFRIGERATING SYSTEM. Y Prior to recharging the system, it shall
be pressure-tested with the appropriate purging gas. The system shall
be leak-tested on completion of charging but prior to commissioning. A follow
up leak test shall be carried out prior to leaving the site.
Decommissioning Y Before carrying out this procedure, it is essential that the
technician is completely familiar with the
equipment and all its detail. It is recommended good practice that all
refrigerants are recovered safely. Y Prior to the task being carried out, an
oil and refrigerant sample shall be taken in case analysis is required
prior to re-use of recovered refrigerant. It is essential that electrical
power is available before the task is commenced.
a) Become familiar with the equipment and its operation.
IMPORTANT INSTRUCTIONS
b) Isolate system electrically. c) Before attempting the procedure, ensure
that:
·mechanical handling equipment is available, if required, for handling
refrigerant cylinders; ·all personal protective equipment is available and
being used correctly; ·the recovery process is supervised at all times by a
competent person; ·recovery equipment and cylinders conform to the appropriate
standards. d) Pump down refrigerant system, if possible. e) If a vacuum is not
possible, make a manifold so that refrigerant can be removed from various
parts of the system. f) Make sure that cylinder is situated on the scales
before recovery takes place. g) Start the recovery machine and operate in
accordance with instructions. h) Do not overfill cylinders (no more than 80 %
volume liquid charge). i) Do not exceed the maximum working pressure of the
cylinder, even temporarily. j) When the cylinders have been filled correctly
and the process completed, make sure that the cylinders and the equipment are
removed from site promptly and all isolation valves on the equipment are
closed off. k) Recovered refrigerant shall not be charged into another
REFRIGERATING SYSTEM unless it has been cleaned and checked.
Labelling Y Equipment shall be labelled stating that it has been de-
commissioned and emptied of refrigerant. The label
shall be dated and signed. For appliances containing FLAMMABLE REFRIGERANTS,
ensure that there are labels on the equipment stating the equipment contains
FLAMMABLE REFRIGERANT.
Recovery Y When removing refrigerant from a system, either for servicing or
decommissioning, it is recommended
good practice that all refrigerants are removed safely. Y When transferring
refrigerant into cylinders, ensure that only appropriate refrigerant recovery
cylinders are
employed. Ensure that the correct number of cylinders for holding the total
system charge is available. All cylinders to be used are designated for the
recovered refrigerant and labelled for that refrigerant (i. e. special
cylinders for the recovery of refrigerant). Cylinders shall be complete with
pressure-relief valve and associated shut-off valves in good working order.
Empty recovery cylinders are evacuated and, if possible, cooled before
recovery occurs. Y The recovery equipment shall be in good working order with
a set of instructions concerning the equipment that is at hand and shall be
suitable for the recovery of all appropriate refrigerants including, when
applicable, FLAMMABLE REFRIGERANTS. In addition, a set of calibrated weighing
scales shall be available and in good working order. Hoses shall be complete
with leak-free disconnect couplings and in good condition. Before using the
recovery machine, check that it is in satisfactory working order, has been
properly maintained and that any associated electrical components are sealed
to prevent ignition in the event of a refrigerant release. Consult
manufacturer if in doubt. Y The recovered refrigerant shall be returned to the
refrigerant supplier in the correct recovery cylinder, and the relevant waste
transfer note arranged. Do not mix refrigerants in recovery units and
especially not in cylinders. Y If compressors or compressor oils are to be
removed, ensure that they have been evacuated to an acceptable level to make
certain that FLAMMABLE REFRIGERANT does not remain within the lubricant. The
evacuation process shall be carried out prior to returning the compressor to
the suppliers. Only electric heating to the compressor body shall be employed
to accelerate this process. When oil is drained from a system, it shall be
carried out safely.
POWER CORD AND PLUG
This air conditioner is equipped with an LCDI (Leakage Current Detection and
Interruption) power cord and plug as required by US National Electric Code
440.65. This cord consists of a length of shielded flexible cord with no
termination on the load side and a LCDI attachment plug on the line side.
The LCDI power cord and plug will remove the supply source via electrical
disconnect (circuit trip) if the nominal current leakage between the cord
shield and either load conductor exceeds a predetermined value. The cord will
remain de-energized until the device has been manually reset. This is intended
to reduce the risk of a fire in the power cord or combustible materials
nearby. The cord shields are not grounded and they must be considered a shock
hazard if exposed. The cord shield must not be connected to ground or to any
exposed metal.
The test and reset buttons on the LCDI Plug are used to check if the plug is
functioning properly. To test:
1. Plug power cord into wall outlet, the LED light will turn on. 2. Press
TEST Button, circuit should trip, cutting power to the air conditioner. When
this occurs, the LED
light will turn off. 3. Press RESET button to restore power to the unit. Once
power is restored, the LED light will turn on
again.
If test button is pressed and unit can still be turned on, current leakage has
been detected. Do not use the air conditioner or attempt to reset the LCDI
Plug. Contact Customer Service for troubleshooting recommendations.
LED LIGHT
RESET TEST
Note: Your unit’s power cord may differ from the one shown.
WARNING:
1. DO NOT press the TEST button while the air conditioner is operating. 2.
The TEST and RESET buttons should not be used as “ON” and “OFF” switches. 3.
The cord and plug are not intended to offer protection to externally connected
loads or supply circuits. 4. The cord and plug are intended for indoor use
only.
PACKAGE CONTENTS
? Hybrid Air Conditioner (1) ? Remote Control (1) ? AAA Battery (2) ? Foam
Sealer (2) ? Mounting Block (2)
? Pre-installed Adjustable Support Knob (2) ? Top Foam Sealer (1) ? Bubble
Level (1) ? Optional Window Security Bracket
– Ttype B Screw (1)
? Owner’s Manual (1)
Air Conditioner (2) – Foam Sealer
Remote Control
2 AAA Batteries
(2) – Mounting Block
(1) – Type B Screw
Bubble Level
(2) – Pre-installed Adjustable Support Knob
Owner’s Manual
Top Foam Sealer
SPECIFICATIONS
· Noise level is measured at a distance of 3.28 ft away from the front of the unit in cooling mode. · Power consumption is measured when the fan runs at the highest speed setting. · These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit.
Model
Power Supply (Ph/V/Hz)
Rated Cooling & Heating Capacity (BTU/h) Cooling & Heating Power Input (Watts)
Rated Current Cooling & Heating (Amperage)
CEER
WS5-08HW-301 1/115/60
8,400/8,400 840 9.2 13.0
Noise Level (dB(A))
38-48(Indoor)/51-63(Outdoor)
Airflow CFM
218/250/270
Dehumidifying Capacity
74 Pints per day
Product Dimensions (W”xH”xD”)
18.7″x15.2″x31.8″
Package Dimensions (W”xH”xD”) Net/Gross Weight (lbs.)
21.3″x17.3″x33.5″ 68.6/77.2
Refrigerant Type
R32
Plug Type
NEMA 5-15P
WS5-10HW-301 1/115/60
10,100/10,000 1070 11.4 13.0
38-48(Indoor)/51-63(Outdoor) 218/250/270
74 Pints per day 18.7″x15.2″x31.8″ 21.3″x17.3″x33.5″
64.6/73.6 R32
NEMA 5-15P
WS5-12HW-301 1/115/60
12,000/10,000 1220 13.5 13.0
38-48(Indoor)/51-63(Outdoor) 218/250/270
74 Pints per day 18.7″x15.2″x31.8″ 21.3″x17.3″x33.5″
64.6/73.6 R32
NEMA 5-15P
FCC Notice
This device has been tested and found to comply with the limits for a Class B
digital device pursuant to Part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential
installation. This device generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruc-
tions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this device does cause harmf ul
interference to radio or television reception, which can be determined by
turning the device off and on, the user is encourag ed to try to correct the
interference by one or more of the following measures:
Reorient or relocate the receiving antenna Increase the separation between the device and receiver Connect the device into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio/television technician for help .
Note: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user ‘s authority to operate the equipment.
ELECTRICAL SAFETY
WARNING:
grounding prong!!
Power supply cord with 3-prong grounding plug and current detection device
DISCLAIMER ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS
USER’S MANUAL ARE THE PRESENATION OF THE MANUFACTURER. SOLEUS N.A.HAS NOT
CONDUCTED AN INDEPENDENT TEST TO VERIFY THE INFORMATION AND SPECIFICATIONS
PRESENTED HEREWITHIN.
INSTALLATION
Window Preparation Please read all instructions prior to installing your air
conditioner. Two people are recommended to install this product. If a new
electrical outlet is required, have the outlet installed by a qualified
electrician before installing the unit.
Before installing the unit, check the dimensions of your window to make sure
the air conditioner will fit. This unit is made to fit inside a standard
double-hung window. Make sure the window is in good shape. If not, make
repairs prior to installing the unit.
Model Unit Height Unit Width Min.Window Opening Height Min.Window Width (Including space needed for window slider) Max Window Width Max Window Sill ft
WS5-08HW-301 15″ 18.7″ 16″
24″
48″ 12.5″
WS5-10HW-301 15″ 18.7″ 16″
24″
48″ 12.5″
WS5-12HW-301 15″ 18.7″ 16″
24″
48″ 12.5″
Storm Window Requirements
A storm window frame will not allow the air conditioner to tilt properly which
will keep it from draining properly. To adjust for this, attach a board or
piece of wood to the sill. The board or wood piece should have a depth of at
least 11/2″. Make sure the board or piece of wood is approximately 1/2″higher
than the storm window frame. This will allow the air
conditioner to tilt enough for proper drainage (See FIG. 2).
16″ MIN
16″ MIN
FIG. 1
FIG .2
Prior to Installing the Air Conditioner 1.Check for anything that could block
airflow. Check the area outside of the window for things such as shrubs,
trees, or awnings. Check the inside area to make sure curtains, drapes, or
blinds will not prevent proper airflow. 2. Check the available electrical
outlet. The power supply must be the same as shown on the unit serial
nameplate
(located on the left side of the unit, near the front faceplate). Be sure the
outlet is close enough for the power cord to reach. 3. Carefully unpack the
air conditioner. Remove all packing material and make sure the floor is
protected when removing. Due to the large size of this air conditioner, two
people should move the unit together.
When handling the unit, be careful to avoid cuts from the sharp metal edges and aluminum fins on the front and rear coils.
INSTALLATION
1. Attach Mounting Blocks on Window Frame (See Fig.1)
- Remove adhesive from mounting block and place mounting block on Fig.1 window frame.
- Press down firmly on the mounting block to secure in place. 3) Then, remove
adhesive from the other mounting block and place
mounting block on window frame. 4) Press down firmly on the mounting block to secure in place. 5) The mounting block are now ready to support the Hybrid Air Condi-
tioner.
2. Slide Hybrid Air Conditioner Over Window Sill
- Open window completely 2) Lift the Hybrid Air Conditioner on either side of the unit and bring it up to the window. 3) Insert the unit into the window until the center of the Hybrid Air Conditioner is over the window sill. 4) Slowly lower the Hybrid Air Conditioner over the window sill so that the unit straddles the wall. 5) Paying close attention to your fingers, completely lower the Hybrid Air Conditioner onto the window sill. 6) Center Hybrid Air Conditioner in the window so that there are equal gaps on either side of the unit.
*Use the adjustable supports to secure the Hybrid AC against
Fig.2
the outside wall. (See Fig.2)
*Use the bubble level to make sure the unit is balanced
Fig.3
when secure on the window sill. When balanced, the bubble should
between the two black lines. (See Fig.3)
3. Attach Window Slider Foam Sealer (See Fig.4 and 5) 1) Measure the distance between the air conditioner and the window sash. 2) Cut to length by using a utility knife
Fig. 4
Fig. 5
INSTALLATION
Attach Window Slider Foam Sealer (See Fig. 6 and 7)
-
Remove adhesive from window side foam sealer.
-
Position foam (adhesive-side) against the left-side edge of the Hybrid Air Conditioner at the point where
the window sash will be aligned with the foam when closed.
- Press the foam firmly in place and hold for 5 seconds.
Fig.7
- Repeat these steps on the right-side edge of the Hybrid Air Conditioner.
Fig.6
5. Attach Top Foam Sealer
- Measure the total width of the installation including the window sliders 2) Cut the top foam sealer to length 3) Remove adhesive from the top foam sealer
- Attach the top foam sealer to the top of the Hybrid Air Conditioner and
window sliders directly below the window sash 5) Close the window sash and seal.
6. Plug in Hybrid Air Conditioner and Power ON
Fig.8
SECURITY BRACKET
Optional Security Bracket Installation
Your Window Kit also includes an optional security bracket that can be
installed to prevent the window from being opened from the outside while a
Window Kit is installed.
Single and Double Hung Windows
END OF SEASON
Remove the Air Conditioner from the Window (End of Season)
1. Turn the air conditioner off, and disconnect the power cord. 2. Remove the
window sliders from either side of the air conditioner. 3. Using a drain pan,
unplug the drain plug on the front bottom of the unit to drain any
condensation water
in the base of unit. 4. Keeping a firm grip on air conditioner, lift up and
remove the air conditioner from the window and
sill. 5. Store parts with the air conditioner in the box.
WIFI APP SETUP
Step 1 SearchSefaorcShmaanrtdLdifoewinlAoapdpSloel’esuAs pp Store
aHnodmotehCerommafjoorrtafprpomstothreesA, oprpscan the followSintogreQoRr
cAondderotoiddSowtonreload the
Smart Life app.
*Screenshots shown are from an Apple iOS device. Android devices may differ slightly.
Step 2 Register for a new account
Step 3
Fill out email address and click the Get Verification Code button. (Email will
be sent with
confirmation instructions)
Step 4
Login with username and password and click add
device
Step 5
Choose Large Home Appliances and Air Conditioner (Wi -Fi)
Step 6 Enter the Wi-Fi name and Password
Step 7 DO NOT TURN ON THE DEVICE . Hold the Timer button over 3 seconds until
the Wi-Fi indicator is flashing on
the control panel
Step 8 Click Done and all set
Step 9
To use the voice commend function, click the Pen icon on the right corner
To reset the Wi -Fi module, hold down the Timer buttons for over 3 seconds
until the beeping sound is heard. Click on “Confirm the indicator is blinking”
in the APP, then select “BLINK QUICKLY”
Note: If the device name is unable to be found from the network list or the
device is un-registered from the APP, the Wi -Fi module needs to be reset.
CONTROL PANEL
Electronic Control Panel & Remote Control Note: This control panel display
always shows the room temperature in Fan Mode and Dry Mode except when setting
the temperature and timer.
Normal Operating Sounds · You may hear a pinging noise caused by water
hitting the condenser on rainy days, or when the humidity is high. This design
feature helps remove moisture and improve efficiency. · You may hear the
thermostat click when the compressor cycles on and off. · Water will collect
in the base pan during rain or days of high humidity. The water may overflow
and drip from the outside part of the unit. · The fan may run even when the
compressor is not on.
Power Button: Turn the air conditioner on and off.
Digital Display: Will display set temperature when the unit is in Cool, Heat,
Energy Saver mode, and display current room temperature when in Auto, Dry, Fan
mode.
Temperature Set: Use these buttons on thecontrol panel or remote to increase
or decrease the Set Temperature.
Fan Speed: Use the fan speed button to change the fan speed. Choose between
high, low, and quiet.
Auto-On Timer: When the air conditioner is off, it can be set to automatically
turn on in 1-24 hours at the previous set mode and fan settings. To set the
Auto-on Timer, press the TIMER button on the unit or remote control. Timer can
be set in 1 hour increment.
Auto-off Timer: When the air conditioner is on, it can be set to automatically
turn off in 1-24 hours. To set the Auto-off Timer, press the TIMER button on
the unit or remote control. Timer can be set in 1 hour increment. Once timer
is set, TIMER ON/OFF indicator on control panel will light up, the set
temperature will also, shown on digital display. To see the remaining time,
press TIMER button. To change the timer settings, use the or on control panel
or remote control. During preview of timer setting, press TIMER button once to
display set time, press the button one more time to cancel the settings.
Energy Saver Mode (Default startup mode): Press the MODE button to turn on
Energy Saver Mode. In Energy Saver mode, set the desired temperature and the
unit will turn-off once the room is cooled or heated to that temperature.
(Compressor shut off.) The unit will turn back on when the room temperature
rises above or drop below the set temperature.
Mode Button: Press the MODE button to cycle through the various modes: Cool,
Dry, Fan, Heat, Auto, Sleep, Energy Saver
T. imer Set: Use these buttons on the control panel and remote control to set
the timer. Each press of the or button will increase or decrease the timer.
Filter Reset: Press the FILTER RESET button to reset the filter light. The
light will illuminate every 250 hours of operation as a reminder to clean the
filter.
Signal Receiver: Point the remote control to the air conditioner when sending
instruction to the unit.
REMOTE CONTROL
POWER BUTTON
UP ARROW (TEMP/TIMER) MODE BUTTON DOWN ARROW (TEMP/TIMER)
FAN SPEED
CHILD LOCK BUTTON MYTEMP MODE BUTTON
SLEEP BUTTON TIMER BUTTON
ENERGY SAVER BUTTON
AUTO MODE BUTTON
Battery Size: AAA – NOTE: Do not mix old and new batteries or different types of AAA batteries. .
OPERATION INSTRUCTIONS
1. ON/OFF – Press the POWER button to turn the A/C on or off. When the unit
is turned off, the Timer function will be cancelled. The set temperature will
be saved.
2. MODE SELECTION – Press the MODE button repeatedly to cycle between the
different modes: Cool, Dry (Dehumidifier), Fan and Heat.
3. TEMPERATURE SETTING – Press the button to decrease the temperature when
the unit is on. Stop pressing the button when the desired temperature is
displayed. Temperature range is 62F-86F. Press the button to increase the
temperature when the unit is on. Stop pressing the button when the desired
temperature is displayed. Temperature range is 62F-86F. While the unit is on,
press the and buttons simultaneously to switch between Celsius and Fahrenheit.
4. FAN – Press the MODE button to turn on the fan mode. FAN HIGH Press this
button to set the fan speed to high. Can be used in COOL, FAN and HEAT mode.
FAN LOW Press this button to set the fan speed to medium. Can be used in
COOL, FAN and HEAT mode. QUIET–Press this button to set the fan speed to
quiet. Can be used in COOL, FAN and HEAT mode.
5. SLEEP MODE – Press the SLEEP button on the remote control, When in SLEEP
mode, the fan will run on quiet to keep fan noise at a minimum. The
temperature setting will gradually increase to 1°F above the original set
temperature for each of first 2 hours when cooling. The temperature setting
will gradually decrease to 1°F below the original set temperature for each of
first 2 hours when heating. The unit will keep operating the same temperature
until the sleep mode is turned off. Once the SLEEP mode is set, the display of
the control panel will automatically dim after 10 seconds.
6. ENERGY SAVER MODE- Press the ENERGY SAVER mode button to turn on ENERGY
SAVER mode. When the unit is in ENERGY SAVER mode, the ENERGY SAVER light will
turn on. Set the unit to the desired temperature for the room. Selecting
ENERGY SAVER mode will cycle the fan off and on with the compressor to limit
energy consumption and maintain the desired temperature. Use this feature when
the room is unoccupied and a greater range of room temperature is acceptable.
*Energy Saver mode is the default startup mode
7. AUTO MODE- Press the AUTO button to activate auto mode. When the unit is
in AUTO mode, the unit will automatically choose the fan speed and cycle
between COOL, FAN and HEAT modes to maintain the room temperature. Auto Mode
will operate the unit in COOL mode when the temperature is above 72 degrees,
FAN mode when the temperature is between 68-72 degrees, HEAT model when the
temperature is below 68 degrees.
8. TIMER – Press the TIMER button when the unit is off to set up the Auto-on
timer. The hour indicator on the digital display will start flashing. Press
the and button to set timer within 1-24 hours. Press the TIMER button when the
unit is on to set up the Auto-off timer. The hour indicator on the digital
display will start flashing. Press the and button to set timer within 1-24
hours. To cancel the timer, press the TIMER button again.
9. MY TEMP MODE – Press the MYTEMP MODE button to change the thermostat
sensor from the air condi. tioner to the remote location. When MYTEMP MODE is
activated, double hyphen sign “–” will flash 3 sec-
onds on digital display. The air conditioner will cool the area depending on
the location and set temperature of the remote control. Take the remote
control with you so the air conditioner cools the room to your location.
10. CHILD LOCK Press this button 3 seconds to lock/unlock the remote control
buttons.
USE THE AIR CONDITIONER
Freezing Conditions: This air conditioner is not designed for freezing outdoor
conditions. It must not be used in freezing outdoor conditions.
Remote Control: To ensure proper operation when using the remote control, aim
the remote directly at the signal receiver on the air conditioner.
The remote control has a signal range up to 20 feet. Make sure nothing is
blocking the remote control signal from being received by the air conditioner.
Make sure the batteries are installed correctly and still have power.
Cooling & Heating Mode: Use the Cool or Heat mode at High, Low, Quiet fan
speed when needed. Use the temperature or buttons to set the desired
temperature between 62°F-86°F. Once the temperature is set, the compressor
will cycle on and off to keep the room temperature at the set temperature
level. The lower the set thermostat temperature, the cooler the room will be.
The higher the set thermostat temperature, the warmer the room will become.
Energy Saver Mode: When the Energy Saver mode is ON, the fan will cycle on and
off with the compressor. This results in more variations of room temperature
and humidity. Normally, it is used when the room is unoccupied. The fan may
continue to run for a short time after the compressor cycles off. When the
Energy Saver mode is OFF, the fan runs all the time in fan, cool and heat
mode.
*Energy Saver mode is the default startup mode
Fan Only Mode: Use Fan Only mode at High, Low, or Quiet fan speed to provide
air circulation and filtering without cooling. Since Fan Only setting does not
provide cool, a set temperature cannot be entered. The room temperature will
appear in the display.
Loss of Power Protection: If power to the air conditioner is lost or
interrupted, the air conditioner will automatically restart in the setting
last used prior to power loss. Timer will be cancelled when power is lost or
interrupted. You may need to set a new timer if desired.
Auto Mode: The air conditioner will automatically choose Cool, Fan and Heat
mode based on current room temperature.
Air Direction: Use the lever on the front air vents to adjust the airflow
direction. You can direct the airflow to left, right, up or down.
Air Deflector
Vertical Wheel
Air Deflector
<
USE AND CARE
CARE AND CLEANING Clean your air conditioner to keep it looking new and to
minimize dust build up.
Air Filter Cleaning The air filter should be checked at least once every month
to see if it needs cleaning. Trapped particles and dust can build up in the
filter and may decrease airflow as well as cause the cooling coils to
accumulate frost. To clean the air filter:
1. Remove the filter by pulling on the indents of the front panel on the top,
right and left side of the unit. 2. Wash the filter using liquid dish soap and
warm water. Rinse the filter thoroughly. Gently shake the filter to re-
move excess water. 3. Let the filter dry completely before placing back it
into the air conditioner. 4. If you do not wish to wash the filter, you may
vacuum the filter to remove the dust and other particles.
Left Tab
Right Tab
Wear and Tear To minimize wear and tear on the air conditioner, always wait at
least 3 minutes before changing modes. This will protect the compressor and
extend product life.
Cabinet Cleaning To clean the air conditioner cabinet:
· Unplug the air conditioner to prevent shock or a fire hazard. The cabinet
and front panel of the air conditioner may be dusted with an oil- free cloth
or washed with a cloth dampened in a solution of warm water and mild liquid
soap. Rinse thoroughly with a damp cloth and wipe dry.
· Never use harsh cleaners, wax or polish on the cabinet front.
· Be sure to wring excess water from the cloth before wiping around the
controls. Excess water in or around the controls may cause damage to the air
conditioner.
Winter Storage To store the air conditioner when it is not in use for an extended period of time, remove it carefully from the window according to the installation instructions and cover it with plastic or place it in the original box.
Error Codes If an error code illuminates on the digital display, unplug the power cord from the wall and plug it back in. Most of the time, this will reset the error code. If the error code continues to display, call our customer service line at 866-669-9998 for further troubleshooting.
Error Codes
Description
E1
Pipe Temperature Sensor Failure
<
E2
Room Temperature Sensor Failure
E4
Freeze Protection
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSES
The Air Conditioner will not start The air conditioner is unplugged
The fuse is blown/circuit breaker is tripped
SOLUTIONS
· Make sure the air conditioner
plug is pushed completely into the outlet.
· Check the main fuse/circuit
breaker box and replace the fuse or reset the breaker.
Power failure
· The unit will automatically restart
when power is restored.
· There is a protective time delay
(approx. 3 minutes) to prevent tripping of the compressor overload. For this
reason, the unit may not start normal cooling for 3 minutes after it is turned
back on.
The LCDI plug is tripped
· Press the RESET button located
on the power cord plug.
· If the RESET button will not stay
engaged, discontinue use of the air conditioner and contact a qualified
service technician.
The Air Conditioner does not cool as it should
Airflow is restricted
· Make sure there are no curtains,
blinds, or furniture blocking the front of the air conditioner.
The temperature control may not be set correctly
· Lower the set thermostat tempera-
ture.
The air filter is dirty
· Clean the filter. See the Cleaning
and Care Section of the manual.
The room may be too warm
· Please allow time for the room to
cool down after turning on the air conditioner.
Cold air is escaping
· Check for open furnace registers
and cold air returns.
The Cooling Coils are frozen
· See “Air Conditioner Freezing Up”
below.
The Air Conditioner is freezing up Water is dripping outside
Ice blocks the air flow and stops the air · Set the MODE dial to HIGH FAN
conditioner from cooling the room
or HIGH COOL and set the ther-
mostat to a higher temperature.
Hot and humid weather
? · This is normal
<
TROUBLESHOOTING
PROBLEM
Water is dripping inside the room
POSSIBLE CAUSES
The air conditioner is not correctly tilted towards the outside
The drain plug is unplugged.
Water collects in the base pan
Moisture removed from the air is draining into the base pan
Unit turns off automatically, code “FL” displays on the control panel
Internal water bucket is full
The Remote Control is not working
The batteries are inserted incorrectly or the batteries may be dead
SOLUTIONS
· For proper water drainage, make
sure the air conditioner is slightly tilted downward from the front of the
unit to the rear.
· Firmly press on the drain plug at
the front, bottom-left side of the unit.
· This is normal for a short period in
areas with low humidity and normal for a longer period in areas with high
humidity.
· Use the front, bottom-left side drain
port to empty the water and the unit will turn back on.
· Check the position of the batter-
ies.
· Replace the batteries
Our units use the latest heat pump technology on the marketplace. Heat pump technology is the most efficient in heat mode above 30°F degrees. Heat pump technology does not work as efficiently on temperatures below 30°F, it is recommended to use auxiliary heat from central air or a space heater.
WIRING DIAGRAM
<
LIMITED WARRANTY
One Year Limited Warranty SOLEUS N.A.warrants the accompanying Air Conditioner
to be free of defects in material and workmanship for the applications
specified in its operation instruction for a period of One (1) year from the
date of original retail purchase in the United S tates. If the unit exhibits a
defect in normal use, SOLEUS N.A.will, at its option, either repair or replace
it, free of charge within a reasonable time after the unit is returned during
the warranty period. As a condition to any warranty service obligation, the
consumer must present this Warranty Certificate along with a copy of t he
original purchase invoice. THIS WARRANTY DOES NOT COVER:
·Damage, accidental or otherwise, to the unit while in the possession of a
consumer not caused by a defect in material or
workmanship.
·Damage caused by consumer misuse, tampering, or failure to follow the care
and special handling provisions in the in-
structions.
·Damage to the finish of the case, or other appearance parts caused by wear.
·Damage caused by repairs or alterations of the unit by anyone other than
those authorized by SOLEUS N.A. ·Freight and Insurance cost for the warranty
service. ·Filter and Accessories
ALL WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY ARE LIMITED
TO THE DURATION OF THIS EXPRESS LIMITED WARRANTY. SOLEUS N.A. DISCLAIMS ANY
LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT SHALL SOLEUS
N.A.’S LIABILITY EXCEED THE RETAIL VALUE OF THE UNIT FOR BREACH OF ANY WRITTEN
OR IMPLIED WARRANTY WITH RESPECT TO THIS UNIT.
This warranty covers only new products purchased from our authorized dealers
or retailers. It does not cover used, salvaged, or refurbished products.
As some states do not allow the limitation or exclusion of incidental or
consequential damages, or do not allow limitation on implied warranties, the
above limitations and exclusions may not apply to you. This warranty gives you
specific legal rights, a nd you may also have other rights that vary from
state to state. For Technical Support and Warranty Service
Please Call 866-669-9998 www.ftl411.com
<