MillerEdge ME123-2U-12-T2 Commercial and Industrial Door Operators User Guide
- June 14, 2024
- MillerEdge
Table of Contents
- MillerEdge ME123-2U-12-T2 Commercial and Industrial Door Operators
- Product Usage Instructions
- PRODUCT ORDERING GUIDE
- CORNELL MG/SG / US GEAR
- LIFTMASTER / CHAMBERLAIN
- Monitored Device Wiring Diagrams
- LINEAR
- Monitored Device Wiring Diagram
- MANARAS – OPERA
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MillerEdge ME123-2U-12-T2 Commercial and Industrial Door Operators
Product Specifications
- Product Type: Sensing Edge Model
- Wire Type: 2 Wire or 4 Wire
- Outlet Location: Varies based on Designator
- Resistor Types: 8.2K Ohm, 10K Ohm, 6.8K Ohm, 270K Ohm
- Capacitor Types: Diode Capacitor, Capacitor
Product Usage Instructions
2 Wire Edge Designator Usage
For 2 Wire Edge Designators, follow these steps:
- Identify the correct Sensing Edge Model based on the Operator Manufacturer.
- Connect the sensing module to the main control board using the provided wiring diagram.
- Ensure proper wiring of the monitored device and ancillary devices as per the guidelines.
- Verify the resistor type required for your specific application and use the corresponding model.
4 Wire Edge Designator Usage
For 4 Wire Edge Designators, follow these steps:
- Select the appropriate Sensing Edge Model based on the Operator Manufacturer.
- Connect the edge designator as per the provided wiring instructions.
- Ensure correct wiring of the monitored device and ancillary devices according to the specifications.
Frequently Asked Questions (FAQ)
-
Q: How do I determine the correct Sensing Edge Model for my door operator?
A: Refer to the Product Ordering Guide and match the Operator Manufacturer with the corresponding Sensing Edge Model listed. -
Q: What should I do if I encounter compliance issues with the product?
A: Please contact Miller Edge or your operator manufacturer for up-to-date compliance information and assistance. -
Q: Can I use custom wire types with the product?
A: It is recommended to use the specified wire types mentioned in the ordering guide for optimal product performance.
PRODUCT ORDERING GUIDE
For UL 325 Listed
Commercial and Industrial Door Operators Built After
August 29, 2010 *Subject to change.
Please contact Miller Edge or your operator manufacturer for current
compliance information
PRODUCT ORDERING GUIDE
This Product Ordering Guide was developed to aid you in selecting the proper
products for use with UL Listed Commercial and Industrial door operators built
after August 29, 2010. We have included product recommendations for both
monitored and ancillary devices for most of the leading operator
manufacturers. The chart below outlines the Monitored Sensing Edge Designator
and its properties. It is important to understand the formula for creating a
Miller Edge Part number. If you have any questions, feel free to contact your
local Miller Edge Sales Representative.
(Eastern Time – 1-800-220-3343 )
(Mountain Time – 1-800-887-3343)
Part Number Example:
Monitored Sensing Edge Designator
2 Wire Edge Designator ex. ME123-2U-12-T2
|
Designator Description
|
Operator Manufacturer
|
Outlet Wire Color Code
---|---|---|---
T1
|
8.2K Ohm Resistor
|
Typically European Use
|
Green
T2| 10K Ohm Resistor| Cornell / US Gear| Blue
| | LiftMaster / Chamberlain|
| | Linear|
| | Manaras|
| | Micanan / Napoleon Lynx|
| | Raynor|
| | VE Power Door|
| | Cookson|
| | Lawrence|
T3| Diode Capacitor| Overhead Door (Only)| Red
T4| Capacitor| Linear (Transmitter)| White
T5| 6.8K Ohm Resistor| Custom Applications| Orange
T6| 270K Ohm Resistor| LiftMaster CPS Board| Violet
4 Wire Edge Designator ex. ME123-4U-12| N/A| LiftMaster| None
Subject to change.
Please contact Miller Edge or your operator manufacturer for current
compliance information
CORNELL MG/SG / US GEAR
Operator Manufacturer| Monitored Device| Ancillary
Device
---|---|---
Cornell / US Gear|
- SENSING EDGE NO SIGNATURE
- MODULE REQUIRED
- Use any 2 wire monitored Miller Edge model beginning with ME, MT, MU, CPT with a
|
- Any 2 Wire Normally Open (N.O.) – ME, MT, MU, CPT,
- Air- Wave, Pneumatic, Invisi-Guard,
- Light Curtain, Patriot, or Photo Eye
| **T2* Designator
Example: ME110-2R-12-T2|
| or|
| PHOTO EYE**|
| Operator Provided Monitored Photo Eye|
Monitored Device Wiring Diagram
- T2 – an embedded 10KΩ resistor with a Blue Band on the edge outlet wire
LIFTMASTER / CHAMBERLAIN
Operator Manufacturer| Monitored Device| Ancillary
Device
---|---|---
Liftmaster/ Chamberlain|
- SENSING EDGE
- USE CPS-MEI Module from
- Use SM-102 xxxxxxxxxxxxxxx
- 2 wire monitored Miller Edge model beginning with ME, MT, MU, CPT
- with a **T2* Designator**
- Example: ME123-2U-12-T2
- or
- PHOTO EYE
- Operator Provided Monitored Photo Eye
|
- LiftMaster Maxum T2/10k
- No module required
|
- Any 2 Wire Normally Open (N.O.) – ME, MT, MU, CPT,
- Air- Wave, Pneumatic, Invisi-Guard, Light Curtain, Patriot, or Photo Eye
Monitored Device Wiring Diagrams
LINEAR
Operator Manufacturer| Monitored Device| Ancillary
Device
---|---|---
Linear| SENSING EDGE|
- Any 2 Wire Normally Open (N.O.) – ME, MT, MU, CPT,
- Air- Wave, Pneumatic, Invisi-Guard,
- Light Curtain, Patriot, or Photo Eye
| USE SM-102 withany 2 wire monitored Miller
| Edge model beginning with
| ME, MT, MU, CPT with a
|
- **T2* Designator**
- Example: ME123-2U-12-T2
- or
| PHOTO EYE
| Operator Provided Monitored Photo Eye
Monitored Device Wiring Diagram
MANARAS – OPERA
Operator Manufacturer | Monitored Device | Ancillary Device |
---|---|---|
Manaras |
- SENSING EDGE
- USE SM-102 with
- any 2 wire monitored Miller Edge model beginning with ME, MT, MU, CPT with a
- *T2 Designator**
- Example: ME123-2U-12-T2
- or
- PHOTO EYE
|
- Any 2 Wire Normally Open (N.O.) – ME, MT, MU, CPT,
- Air- Wave, Pneumatic, Invisi-Guard,
- Light Curtain, Patriot, or Photo Eye
| Operator Provided Monitored Photo Eye|
Monitored Device Wiring Diagram
MICANAN / NAPOLEON LYNX
Operator Manufacturer| Monitored Device| Ancillary
Device
---|---|---
Micanan/Napoleon Lynx
| SENSING EDGE
USE SM-102 with
any 2 wire monitored Miller Edge model beginning with ME, MT, MU, CPT with a
**T2* Designator**
Example: ME123-2U-12-T2
| Any 2 Wire Normally Open (N.O.) – ME, MT, MU, CPT,
Air- Wave, Pneumatic, Invisi-Guard,
Light Curtain, Patriot, or Photo Eye
| or|
| PHOTO EYE|
| Operator Provided Monitored Photo Eye|
Monitored Device Wiring Diagram
OVERHEAD DOOR
Operator Manufacturer| Monitored Device| Ancillary
Device
---|---|---
Overhead Door
| SENSING EDGE
USE Miller Edge P/N SM-101 or
Overhead Door P/N OPAKMEIX.S with any 2 wire monitored Miller Edge model beginning with
ME, MT, MU, CPT with a
| ****
Any 2 Wire Normally Open (N.O.) – ME, MT, MU, CPT,
Air- Wave, Pneumatic, Invisi-Guard, Light Curtain, Patriot, or Photo Eye
| T3Designator|
| or|
| PHOTO EYE**|
| Operator Provided Monitored Photo Eye|
Monitored Device Wiring Diagram
** RAYNOR**
Operator Manufacturer| Monitored Device| Ancillary
Device
---|---|---
- Raynor
- No Module Required
|
- SENSING EDGE
- x U xx S x E xx S x M xx -1 xx 0 x 2 xwxxitxhx any 2 wire monitored Miller Edge model beginning with ME, MT, MU, CPT with a
- **T2* Designator**
- Example: ME123-2U-12-T2
|
- Any 2 Wire Normally Open (N.O.) – ME, MT, MU, CPT,
- Air- Wave, Pneumatic, Invisi-Guard,
- Light Curtain, Patriot, or Photo Eye
| or|
| PHOTO EYE|
| Operator Provided Monitored Photo Eye|
Monitored Device Wiring Diagrams
VE POWER DOOR
Operator Manufacturer| Monitored Device| Ancillary
Device
---|---|---
VE Power Door
| SENSING EDGE
USE SM-102 with
- any 2 wire monitored Miller Edge model beginning with ME, MT, MU, CPT with a
- **T2* Designator**
- Example: ME123-2U-12-T2
| ****
- Any 2 Wire Normally Open (N.O.) – ME, MT, MU, CPT,
- Air- Wave, Pneumatic, Invisi-Guard,
- Light Curtain, Patriot, or Photo Eye
| or|
| PHOTO EYE|
| Operator Provided Monitored Photo Eye|
COOKSON
Operator Manufacturer| Monitored Device| Ancillary
Device
---|---|---
Cookson|
- SENSING EDGE NO SIGNATURE
- MODULE REQUIRED
- Use any 2 wire monitored Miller Edge model beginning with
- ME, MT, MU, CPT with a
- **T2* Designator**
- Example: ME110-2R-12-T2
- or
| ****
- Any 2 Wire Normally Open (N.O.) – ME, MT, MU, CPT,
- Air- Wave, Pneumatic, Invisi-Guard,
- Light Curtain, Patriot, or Photo Eye
| PHOTO EYE|
| Operator Provided Monitored Photo Eye|
LAWRENCE
Operator Manufacturer| Monitored Device| Ancillary
Device
---|---|---
Lawrence| SENSING EDGE
- NO SIGNATURE MODULE REQUIRED
- Use any 2 wire monitored Miller Edge model beginning with
- ME, MT, MU, CPT with a
- **T2* Designator**
- Example: ME110-2R-12-T2 or
| ****
- Any 2 Wire Normally Open (N.O.) – ME, MT, MU, CPT,
- Air- Wave, Pneumatic, Invisi-Guard,
- Light Curtain, Patriot, or Photo Eye
| PHOTO EYE|
| Operator Provided Monitored Photo Eye|
- T2 – an embedded 10KΩ resistor with a Blue Band on the edge outlet wire
- Subject to change.
- Please contact Miller Edge or your operator manufacturer for current compliance information
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>