Product Specifications

  • Product Type: Sensing Edge Model
  • Wire Type: 2 Wire or 4 Wire
  • Outlet Location: Varies based on Designator
  • Resistor Types: 8.2K Ohm, 10K Ohm, 6.8K Ohm, 270K Ohm
  • Capacitor Types: Diode Capacitor, Capacitor

Product Usage Instructions

2 Wire Edge Designator Usage
For 2 Wire Edge Designators, follow these steps:

  1. Identify the correct Sensing Edge Model based on the Operator Manufacturer.
  2. Connect the sensing module to the main control board using the provided wiring diagram.
  3. Ensure proper wiring of the monitored device and ancillary devices as per the guidelines.
  4. Verify the resistor type required for your specific application and use the corresponding model.

4 Wire Edge Designator Usage

For 4 Wire Edge Designators, follow these steps:

  1. Select the appropriate Sensing Edge Model based on the Operator Manufacturer.
  2. Connect the edge designator as per the provided wiring instructions.
  3. Ensure correct wiring of the monitored device and ancillary devices according to the specifications.

Frequently Asked Questions (FAQ)

  • Q: How do I determine the correct Sensing Edge Model for my door operator?
    A: Refer to the Product Ordering Guide and match the Operator Manufacturer with the corresponding Sensing Edge Model listed.

  • Q: What should I do if I encounter compliance issues with the product?
    A: Please contact Miller Edge or your operator manufacturer for up-to-date compliance information and assistance.

  • Q: Can I use custom wire types with the product?
    A: It is recommended to use the specified wire types mentioned in the ordering guide for optimal product performance.

PRODUCT ORDERING GUIDE
For UL 325 Listed
Commercial and Industrial Door Operators Built After
August 29, 2010 *Subject to change.
Please contact Miller Edge or your operator manufacturer for current compliance information

PRODUCT ORDERING GUIDE

This Product Ordering Guide was developed to aid you in selecting the proper products for use with UL Listed Commercial and Industrial door operators built after August 29, 2010. We have included product recommendations for both monitored and ancillary devices for most of the leading operator manufacturers. The chart below outlines the Monitored Sensing Edge Designator and its properties. It is important to understand the formula for creating a Miller Edge Part number. If you have any questions, feel free to contact your local Miller Edge Sales Representative.
(Eastern Time – 1-800-220-3343 ) (Mountain Time – 1-800-887-3343)
Part Number Example:

Monitored Sensing Edge Designator


2 Wire Edge Designator ex. ME123-2U-12-T2

|

Designator Description

|

Operator Manufacturer

|

Outlet Wire Color Code

---|---|---|---

T1

|

8.2K Ohm Resistor

|

Typically European Use

|

Green

T2| 10K Ohm Resistor| Cornell / US Gear| Blue
| | LiftMaster / Chamberlain|
| | Linear|
| | Manaras|
| | Micanan / Napoleon Lynx|
| | Raynor|
| | VE Power Door|
| | Cookson|
| | Lawrence|
T3| Diode Capacitor| Overhead Door (Only)| Red
T4| Capacitor| Linear (Transmitter)| White
T5| 6.8K Ohm Resistor| Custom Applications| Orange
T6| 270K Ohm Resistor| LiftMaster CPS Board| Violet
4 Wire Edge Designator ex. ME123-4U-12| N/A| LiftMaster| None

Subject to change.
Please contact Miller Edge or your operator manufacturer for current compliance information

CORNELL MG/SG / US GEAR

Operator Manufacturer| Monitored Device| Ancillary Device
---|---|---
Cornell / US Gear|

  • SENSING EDGE NO SIGNATURE
  • MODULE REQUIRED
  • Use any 2 wire monitored Miller Edge model beginning with ME, MT, MU, CPT with a

|

  • Any 2 Wire Normally Open (N.O.) – ME, MT, MU, CPT,
  • Air- Wave, Pneumatic, Invisi-Guard,
  • Light Curtain, Patriot, or Photo Eye

| **T2* Designator
Example: ME110-2R-12-T2|
| or|
|
PHOTO EYE**|
| Operator Provided Monitored Photo Eye|

Monitored Device Wiring Diagram

  • T2 – an embedded 10KΩ resistor with a Blue Band on the edge outlet wire

LIFTMASTER / CHAMBERLAIN

Operator Manufacturer| Monitored Device| Ancillary Device
---|---|---
Liftmaster/ Chamberlain|

  • SENSING EDGE
  • USE CPS-MEI Module from
  • Use SM-102 xxxxxxxxxxxxxxx
  • 2 wire monitored Miller Edge model beginning with ME, MT, MU, CPT
  • with a **T2* Designator**
  • Example: ME123-2U-12-T2
  • or
  • PHOTO EYE
  • Operator Provided Monitored Photo Eye

|


  • LiftMaster Maxum T2/10k
  • No module required

|

  • Any 2 Wire Normally Open (N.O.) – ME, MT, MU, CPT,
  • Air- Wave, Pneumatic, Invisi-Guard, Light Curtain, Patriot, or Photo Eye

Monitored Device Wiring Diagrams

LINEAR

Operator Manufacturer| Monitored Device| Ancillary Device
---|---|---
Linear| SENSING EDGE|

  • Any 2 Wire Normally Open (N.O.) – ME, MT, MU, CPT,
  • Air- Wave, Pneumatic, Invisi-Guard,
  • Light Curtain, Patriot, or Photo Eye

| USE SM-102 withany 2 wire monitored Miller
| Edge model beginning with
| ME, MT, MU, CPT with a
|

  • **T2* Designator**
  • Example: ME123-2U-12-T2
  • or

| PHOTO EYE
| Operator Provided Monitored Photo Eye

Monitored Device Wiring Diagram

MANARAS – OPERA

Operator Manufacturer Monitored Device Ancillary Device
Manaras
  • SENSING EDGE
  • USE SM-102 with
  • any 2 wire monitored Miller Edge model beginning with ME, MT, MU, CPT with a
  • *T2 Designator**
  • Example: ME123-2U-12-T2
  • or
  • PHOTO EYE

|

  • Any 2 Wire Normally Open (N.O.) – ME, MT, MU, CPT,
  • Air- Wave, Pneumatic, Invisi-Guard,
  • Light Curtain, Patriot, or Photo Eye

| Operator Provided Monitored Photo Eye|

Monitored Device Wiring Diagram

MICANAN / NAPOLEON LYNX

Operator Manufacturer| Monitored Device| Ancillary Device
---|---|---


Micanan/Napoleon Lynx

| SENSING EDGE

USE SM-102 with

any 2 wire monitored Miller Edge model beginning with ME, MT, MU, CPT with a

**T2* Designator**

Example: ME123-2U-12-T2

| Any 2 Wire Normally Open (N.O.) – ME, MT, MU, CPT,

Air- Wave, Pneumatic, Invisi-Guard,

Light Curtain, Patriot, or Photo Eye

 | or|
 | PHOTO EYE|
 | Operator Provided Monitored Photo Eye|

Monitored Device Wiring Diagram


OVERHEAD DOOR

Operator Manufacturer| Monitored Device| Ancillary Device
---|---|---


Overhead Door

| SENSING EDGE

USE Miller Edge P/N SM-101 or

Overhead Door P/N OPAKMEIX.S with any 2 wire monitored Miller Edge model beginning with

ME, MT, MU, CPT with a

| ****

Any 2 Wire Normally Open (N.O.) – ME, MT, MU, CPT,

Air- Wave, Pneumatic, Invisi-Guard, Light Curtain, Patriot, or Photo Eye

| T3Designator|
| or|
|
PHOTO EYE**|
| Operator Provided Monitored Photo Eye|

Monitored Device Wiring Diagram

** RAYNOR**

Operator Manufacturer| Monitored Device| Ancillary Device
---|---|---

  • Raynor
  • No Module Required

|

  • SENSING EDGE
  • x U xx S x E xx S x M xx -1 xx 0 x 2 xwxxitxhx any 2 wire monitored Miller Edge model beginning with ME, MT, MU, CPT with a
  • **T2* Designator**
  • Example: ME123-2U-12-T2

|

  • Any 2 Wire Normally Open (N.O.) – ME, MT, MU, CPT,
  • Air- Wave, Pneumatic, Invisi-Guard,
  • Light Curtain, Patriot, or Photo Eye

 | or|
 | PHOTO EYE|
 | Operator Provided Monitored Photo Eye|

Monitored Device Wiring Diagrams

VE POWER DOOR

Operator Manufacturer| Monitored Device| Ancillary Device
---|---|---


VE Power Door

| SENSING EDGE

USE SM-102 with

  • any 2 wire monitored Miller Edge model beginning with ME, MT, MU, CPT with a
  • **T2* Designator**
  • Example: ME123-2U-12-T2

| ****

  • Any 2 Wire Normally Open (N.O.) – ME, MT, MU, CPT,
  • Air- Wave, Pneumatic, Invisi-Guard,
  • Light Curtain, Patriot, or Photo Eye

 | or|
 | PHOTO EYE|
 | Operator Provided Monitored Photo Eye|

COOKSON

Operator Manufacturer| Monitored Device| Ancillary Device
---|---|---
Cookson|

  • SENSING EDGE NO SIGNATURE
  • MODULE REQUIRED
  • Use any 2 wire monitored Miller Edge model beginning with
  • ME, MT, MU, CPT with a
  • **T2* Designator**
  • Example: ME110-2R-12-T2
  • or

| ****

  • Any 2 Wire Normally Open (N.O.) – ME, MT, MU, CPT,
  • Air- Wave, Pneumatic, Invisi-Guard,
  • Light Curtain, Patriot, or Photo Eye

 | PHOTO EYE|
 | Operator Provided Monitored Photo Eye|

LAWRENCE

Operator Manufacturer| Monitored Device| Ancillary Device
---|---|---
Lawrence| SENSING EDGE

  • NO SIGNATURE MODULE REQUIRED
  • Use any 2 wire monitored Miller Edge model beginning with
  • ME, MT, MU, CPT with a
  • **T2* Designator**
  • Example: ME110-2R-12-T2 or

| ****

  • Any 2 Wire Normally Open (N.O.) – ME, MT, MU, CPT,
  • Air- Wave, Pneumatic, Invisi-Guard,
  • Light Curtain, Patriot, or Photo Eye

 | PHOTO EYE|
 | Operator Provided Monitored Photo Eye|

  • T2 – an embedded 10KΩ resistor with a Blue Band on the edge outlet wire