Specifications
- Model: R718PA10
- Wireless Turbidity Sensor
- Power Supply: 12V DC
- Communication: Wireless (LoRaWAN Class A) and RS485
- IP Rating: IP65 / IP67 (Optional)
- Main Features:
- Detects turbidity value and solution temperature
- Equipped with SX1276 wireless communication module
- Base with magnet for easy attachment
- Frequency hopping spread spectrum technology
- Configurable parameters and data reading via third-party
software platforms
Product Usage Instructions
- To power on the device, use a DC12V power supply.
- The green indicator will flash once to indicate successful power-on.
- To power off, remove the DC12V adapter.
- If the device has not joined a network, press and hold the function key for 5 seconds.
- The green indicator will flash 20 times to indicate success. If the device fails to join the network, check registration information on the gateway or consult your platform server provider.
- After powering on, the device will send a version packet report immediately, followed by a report with turbidity value and solution temperature after 20 seconds.
- Data is sent according to default configurations unless modified.
FAQ
-
Q: How can I check the battery life of the sensor?
-
A: Battery life is determined by reporting frequency and other variables. Refer to
http://www.netvox.com.tw/electric/electric_calc.html for battery lifetime based on different configurations. -
Q: What third-party platforms are compatible with this sensor?
-
A: The sensor is compatible with platforms like Actility, ThingPark, TTN, MyDevices, and Cayenne for configuring parameters, reading data, and setting alarms via SMS or email.
Copyright©Netvox Technology Co., Ltd.
This document contains proprietary technical information which is the property of NETVOX Technology. It shall be maintained in strict confidence and shall not be disclosed to other parties, in whole or in part, without written permission of NETVOX Technology. The specifications are subject to change without prior notice.
Introduction
R718PA 10 is a Class A device based on the LoRaWANT™ protocol of Netvox and is
compatible with the LoRaWAN protocol. R718PA 10 can be connected with a
turbidity sensor (RS485) externally and report the turbidity value and the
temperature of the solution collected by the device to the corresponding
gateway.
LoRa Wireless Technology
LoRa is a wireless communication technology dedicated to long-distance and low
power consumption. Compared with other communication methods, the LoRa spread
spectrum modulation method greatly increases to expand the communication
distance. Widely used in long-distance, low-data wireless communications. For
example, automatic meter reading, building automation equipment, wireless
security systems, and industrial monitoring. The main features include small
size, low power consumption, transmission distance, anti-interference ability
and so on.
LoRa WAN
LoRaWAN uses LoRa technology to define end-to-end standard specifications to
ensure interoperability between devices and gateways from different
manufacturers.
Appearance
Main Feature
- Adopt SX1276 wireless communication module
- RS485 communication
- 12V DC power supply
- Detecting the turbidity value and the temperature of the solution
- The base is attached with a magnet that can be attached to a ferromagnetic material object
- Main body protection level IP65 / IP67 (Optional)
- Compatible with LoRaWANT™ Class A
- Frequency hopping spread spectrum technology
- Configuring parameters and reading data via third-party software platforms, and setting alarms via SMS text and email (optional)
- Applicable to the third-party platforms: Actility/ ThingPark/ TTN/ MyDevices/ Cayenne
Note
Battery life is determined by the sensor reporting frequency and other
variables, please refer to
http://www.netvox.com.tw/electric/electric_calc.html.
On this website, users can find battery lifetime for varied models at
different configurations.
Set Up Instruction
On/Off
Power On| DC12V adapter
Turn On| DC12V power supply, the green indicator flashing once means turn on
successfully.
Restore To Factory Setting| Press and hold the function key for 5 seconds, and
the green indicator flashes 20 times.
Power Off| Remove DC12V adapter
Note| 1. On/off interval is suggested to be about 10 seconds to avoid the
interference of capacitor inductance and other energy storage components.
2. The first 5 seconds after power on, the device will be in engineering test mode.
Network Joining
Never Join the Network| Turn on the device to search the network.
The green indicator keeps on for 5 seconds: success. The green indicator remains off: fail
**** Had Joined the Network
**** (Not restore to the factory setting)
| Turn on the device to search the previous network. The green indicator keeps on for 5 seconds: success.
The green indicator remains off: fail.
Fail to Join the Network| Suggest checking the device registration information on the gateway or consulting your ****
platform server provider if the device fails to join the network.
Function Key
Press and Hold for 5 Seconds| Restore to the original setting The green
indicator flashes 20 times: success The green indicator remains off: fail
Press once| The device is in the network: the green indicator flashes once and
the device sends a data report
The device is not in the network: the green indicator remains off
Data Report
- After powering on, the device will immediately send a version packet report. Then, it will send another report with the data of the turbidity value and the temperature of the solution after it is powered on for 20s
- The device sends data according to the default configuration before any other configuration.
Default Setting
- Maxime: Max Interval = 3min = 180s
- Min Time: The MinTime configuration is not available.
- But the software has a restriction, MinTime must be configured with a number greater than 0.
Note
- The report interval is based on the factory default.
- R718PA10 reports the turbidity value and the temperature of the solution.
- The device reported data parsing please refer to the Netvox LoRaWAN Application Command document and
Netvox LoRa Command Resolver http://www.netvox.com.cn:8888/cmddoc
Example of ReportDataCmd
FPortFPort: 0x06
Bytes | 1 | 1 | 1 | Var(Fix=8 Bytes) |
---|---|---|---|---|
Version | DeviceType | ReportType | NetvoxPayLoadData |
- Version- 1 byte -0x01 the Version of NetvoxLoRaWAN Application Command Version
- Device Type 1 byte – Device Type of Device
- Report Type – 1 byte -the presentation of the NetvoxPayLoadData, according to the device type
- NetvoxPayLoadData- Fixed bytes (Fixed =8bytes)
Device| Device
Type
| Report
Type
| NetvoxPayLoadData
---|---|---|---
R718PA series
(R718PA10)
|
0x57
|
0x09
|
Battery (1Byte, unit:0.1V)
|
NTU
(2Byte ,0.1ntu)
|
TemperaturewithNTU (Signed 2Bytes,unit:0.01°C)
|
EC5SoildHumidtiy (2Bytes,unit:0.01%)
|
Reserved (1Bytes,fixed 0x00)
Uplink: 0157090007D009E2FFFF00
- 1st byte (01): Version
- 2nd byte (57): DeviceType-R718PA Series
- 3rd byte (09): Report Type
- 4th byte (00): Battery; When Battery is 0x00, it represents is powered by DC/AC power source
- 5th 6th byte(07D0): NTU(Turbidity), 7D0 Hex = 2000 Dec, 2000*0.1 ntu = 200 ntu
- 7th 8th byte (09E2): Temperature with NTU, 9E2 Hex = 2530 Dec, 2530*0.01°C= 25.3°C
- 9th 10th byte (FFFF): Soil Humidity, please ignore.
- 11th byte (00): Reserved
Example of ConfigureCmd
FPortFPort: 0x07
Bytes | 1 | 1 | Var (Fix =9 Bytes) |
---|---|---|---|
CmdID | DeviceType | NetvoxPayLoadData |
- CmdID– 1 byte
- DeviceType– 1 byte – Device Type of Device
- NetvoxPayLoadData var bytes (Max=9bytes)
Description
|
Device
| Cmd
ID
| Device
Type
|
NetvoxPayLoadData
---|---|---|---|---
ConfigReport
Req
|
R718PA10
|
0x01
|
0x57
| MinTime
(2bytes Units: s)
| Maxime
(2bytes Units: s)
| Reserved
(5Bytes,Fixed 0x00)
ConfigReport
Rsp
|
0x81
| Status
(0x00_success)
| Reserved
(8Bytes, Fixed 0x00)
ReadConfig
ReportReq
|
0x02
| Reserved
(9Bytes, Fixed 0x00)
ReadConfig
ReportRsp
|
0x82
| MinTime
(2bytes Units: s)
| Maxime
(2bytes Units: s)
| Reserved
(5Bytes,Fixed 0x00)
Configure R718PA10 device parameter Max Time = 1 min
(The MinTime configuration is useless, but it needs to be set greater than 0
because of the software limitation.)
- Downlink: 0157000A003C0000000000
Device Return
- 8157000000000000000000 (configuration success)
- 8157010000000000000000 (configuration failure)
Read R718PA 10 device parameter
- Downlink: 0257000000000000000000
Device Return
- 8257000A003C0000000000 (device current parameter)
Installation
- R718PA10 has a built-in magnet (as the figure below) that can be attached to the surface of an iron object during installation, which is convenient and quick. To make the installation firmer, please use screws (purchased separately) to fix the device to the wall or other surface (as Figure below).
Note
Do not install the device in a metal shielded box or in an environment
surrounded by other electrical equipment to avoid affecting the wireless
transmission of the device.
- R718PA 10 regularly reports the data of the turbidity value and the temperature of the solution according to Max Time.
- The default Max Time is 3 minutes.
Note
Max Time can be modified by the downlink command, but it is recommended not to
set the interval too short.
- R718PA10 can be applied to detect the turbidity and the temperature of the solution.
Example
- Water Quality Monitor
Note
- The probe contains sensitive optical and electronic components. Make sure that the probe is not subject to severe mechanical shocks. There are no parts inside the probe that need users’ maintenance.
- The black plastic cap on the head of the turbidity sensor should be removed during the test; otherwise, it will affect the measurement.
Maintenance Method
-
External Surface of The Sensor:
Use tap water to clean the external surface of the sensor. If there are still debris remaining, wipe it with a moistened soft cloth.
For some stubborn dirt, users can add some household detergent to the tap water to clean it. -
Check the Cable of The Sensor:
The cable should not be taut during normal operation; otherwise, the internal wires of the cable may break and the sensor cannot work normally. -
Check whether the measuring part of the sensor is dirty, and whether the cleaning brush is normal.
Important Maintenance Instruction
Kindly pay attention to the following in order to achieve the best maintenance of the product:
- Keep the device dry. Rain, moisture, or any liquid, might contain minerals and thus corrode electronic circuits. If the device gets wet, please dry it completely.
- Do not use or store the device in dusty or dirty environment. It might damage its detachable parts and electronic components.
- Do not store the device under excessive heat condition. High temperature can shorten the life of electronic devices, destroy batteries, and deform or melt some plastic parts.
- Do not store the device in places that are too cold. Otherwise, when the temperature rises to normal temperature, moisture will form inside, which will destroy the board.
- Do not throw, knock or shake the device. Rough handling of equipment can destroy internal circuit boards and delicate structures.
- Do not clean the device with strong chemicals, detergents or strong detergents.
- Do not apply the device with paint. Smudges might block in the device and affect the operation.
- Do not throw the battery into the fire, or the battery will explode. Damaged batteries may also explode.
All of the above applies to your device, battery and accessories. If any device is not working properly, please take it to the nearest authorized service facility for repair.
References
- 【please_ignore.】什么意思_英语please_ignore.的翻译_音标_读音_用法_例句_在线翻译_有道词典
- Netvox LoRaWAN Application Command
- ÉÔºò¡£¡£¡£
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>