JASIC JM-250P MIG 250 Pulse Inverter Mig Welder Instruction Manual

June 8, 2024
JASIC

JASIC JM-250P MIG 250 Pulse Inverter Mig Welder
JASIC JM-250P MIG 250 Pulse Inverter Mig Welder

JM-250P Basic Set-Up Guide – Standard (Synergic) MIG/MAG

For Standard (Synergic) MIG/MAG welding, set up as below and ensure you have “Synergic” mode Selected. 2T/4T trigger modes can be selected dependant on user requirements.
JM-250P Basic Set-Up Guide – Standard \(Synergic\)
MIG/MAG

The parameter selection button (H) allows you to scroll through the adjustable parameters for Standard Synergic MIG/MAG as follows:
JM-250P Basic Set-Up Guide – Standard \(Synergic\)
MIG/MAG

  • A. P-1: Gas pre-flow time (2T/4T)
  • B. P-2: Initial parameters (4T only)
  • C. P-3: Upslope time (4T only)
  • D. – Peak welding parameters
  • E. P-4: Downslope time (4T only)
  • F. P-5: Final parameter (4T only)
  • G. P-6: Post-flow time (2T/4T)
  • H. – Parameter selection button

The corresponding indicators will be lit according to selected parameters, the variable setting is noted in the left display and the adjustable values are shown on the right displays which are adjusted using the right control dial.

Material Thickness Adjustment

In synergic mode “D. – Peak welding parameters” can be adjusted based on material thickness, this is done by;
Material Thickness Adjustment

  1. Press and holding in the right hand dial until the display changes to material thickness (as above).
  2. You can then release the dial and select the thickness of material you are welding by rotating the same dial.
  3. To exit this mode simply press and hold the dial in again to revert back to the original display.

Please Note: The synergic settings are a guide only and dependent on your application adjustments may be required to achieve the desired welding characteristics.

Voltage Trim Adjustment

Trim adjustment should be set to 0.0 to start with and adjusted based on user requirements, this is done by rotating the right hand dial when the machine is not in material thickness selection;
Voltage Trim Adjustment

  • Adjusting the trim up from 0.0 to 30 will increase the heat input into the material and give you the effect of having less wire and a longer welding arc.
  • Adjusting the trim down from 0.0 to –30 will reduce the heat input into the material and give you the effect of having more wire and a shorter welding arc.

Quick set up parameters

Use the below guide setting parameter chart to help set up your machine

Parameter| Units| Adjustable Range| Guide Setting| Notes
---|---|---|---|---
Job/Material| —| Fe, St, AlSi, AlMg| User defined *| Set to the type of material you are welding
A. PRE-GAS TIME| Seconds| 0.1 ~ 10| 0.5|
B. INITIAL Parameter| WFS V| 3-15m/min| Match PEAK setting| Adjustment only available in “4T” mode
C. UP-SLOPE TIME| Seconds| 0.1 ~ 5| 0.1| Adjustment only available in “4T” mode
D. PEAK Parameter| WFS

V

| 0.5-10mm| User defined *| Set to thickness of material you are welding (thickness in “mm”)
E. DOWN-SLOPE

TIME

| Seconds| 0.1 ~ 5| 0.1| Adjustment only available in “4T” mode
F. FINAL Parameter| WFS V| 3-15m/min

9.0-36.0V

| Match PEAK setting| Adjustment only available in “4T” mode
G. POST-GAS TIME| Seconds| 0.1~ 10| 2.0|

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

JASIC User Manuals

Related Manuals