CANlink mobile 3000 WiFi and Bluetooth Data Transfer User Guide
- June 3, 2024
- CANlink
Table of Contents
- CANlink mobile 3000 WiFi and Bluetooth Data Transfer
- About this Quick Start Guide
- Provisioning and GoLive
- Unpacking the Launch Kit
- Connecting the Device to a PC
- Installing Proemion Configurator
- Installing Demo Configuration
- Perform a Functional Test
- Check and adjust DataPortal
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
CANlink mobile 3000 WiFi and Bluetooth Data Transfer
About this Quick Start Guide
This document is part of the CANlink mobile 3600 series documentation and
provides information regarding the installation and configuration of the
CANlink mobile 3600 and the first steps with the Launch Kit. The document is
intended for qualified technicians and electricians with advanced knowledge in
electrical engineering and field bus systems, allowing them to assess the
risks and hazards of operating the device and to integrate it into systems
with components of other manufacturers. It provides a quick overview of how to
set the CANlink mobile into operation with the DataPlatform when receiving the
first device together with our Launch Kit. We also assume, that a DataPlatform
account setup has been ordered and the technical contact person at the
customer has received the information about the setup completion.
Figure 1. General system overview
Further information
For a piece of comprehensive information about the several components, please
refer to these manuals:
- CANlink mobile Device Manual
- DataPortal User Manual
- PDC Manual
Onboarding best practice
Due to our experience in integrating a telematics solution into a fleet of
machines, we would like to recommend the following best practice for the
initial start-up of a CANlink mobile together with your data platform access:
- Create a laboratory setup with the device and the launch kit or starter kit.
- Configure the device for your application with our Proemion Configurator software.
- Activate the device.
- Create a PDC file to display the recorded signals on the data portal and assign it to the device via the management portal.
- Check the connection of the device to the data platform and the data transmission and display in your laboratory setup e.g., with simulated, CAN messages.
- Install the device in a real machine and wire it as described in the device manual.
- Now check the functionality on the real machine.
- First, roll out the new setup on a smaller set of pilot machines to prove the solution before using it in the complete fleet.
This document will guide you through the steps necessary for your initial setup.
Provisioning and GoLive
Provisioning allows you to make a machine with a telematics unit installed and available on the DataPortal. The machine will be visible and during the process, you can assign a model and change the machine name, serial number, and PIN/VIN. GoLive is the automated activation of a communication unit (CU) after Provisioning. Once the CU has been activated, it is authorized to connect to the DataPlatform and transfer data.
- ogin to the Proemion DataPortal User Manual
- Log in with your username and password
- Provision the CANlink mobile to make it visible on your DataPortal account as described in the DataPortal ¬ Provisioning
- Use DataPortal ¬ GoLive to activate the device and permit DataPortal communication
INFORMATION
- For the first-time login, the initial password must be set. Please use the “Forgot password” function on DataPortal.
- Enter the username which was provided along with the account setup confirmation email.
- Another email with instructions on how to reset the password will be sent to your email address.
- Please note that the activation of the embedded SIM card can take up to 24 hours in exceptional cases.
Unpacking the Launch Kit
The link mobile 3600 Launch Kit (253000176) consists of the following
components
CLM 3600 Starter Cable (136000202)
Antenna LTE GNSS DA 3M0 FAKRA-D FAKRA-C FAR (157000109)
View USB (253001014) CAN bus terminator D-Sub/D-Sub, 120¬ (157000033)
USB Cable for CANview USB (136000119)
Power Supply Unit With Set Of Connectors (US, EU, UK, AU) and adapter (257004007)
USB Cable (Debugging, Diagnosis), Micro USB Type B (136000138)
Assembly Set M5 Housing GH1208 (141000017)
Figure 10. Assembly Set M5 Housing GH1208
Cable MTII 14pin Code1 14open 2m (136000198)
CANlink mobile 3000 Plug-Kit (132600031)
Figure 12. Connector MT
Figure 12. Connector MT
Figure 14. Single Wire Seal (14 pcs)
Figure 15. Cavity Blanking Plug (14 pcs)
Product Information leaflet (144000133)
Figure 16. Product Information Leaflet
For further information regarding the components of the Launch Kit, please refer to the CANlink mobile Device Manual ¬ Launch Kit.
Connecting the Device to a PC
Connect the CANlink mobile 3600 to your PC as shown in the image below. Please
use the components from the Launch Kit.
Figure 17. Connecting The Device With A PC
- CANlink mobile
- CLM 3600 Starter cable
- Antenna
- CAN bus termination resistor 120 Ohm
- View USB
- Power supply
- USB cable
- PC
Please also refer to CANlink mobile Device Manual ¬ Connecting the Device.
INFORMATION
Please be aware that the CANlink mobile 3600 is not equipped with an integrated CAN bus termination resistor. The displayed laboratory setup above will work with just one CAN bus termination resistor. When doing the system integration at the intended machine, it must be ensured that the CAN bus is terminated with a CAN bus termination resistor of 120 Ohm at each end of the CAN bus line. Please also refer to CANlink mobile Device Manual ¬ Can Bus Termination.
Installing Proemion Configurator
- Install the latest version of the Proemion Configurator from our Download Center.
- In case of problems, the Connectivity Check utility can be used to check the connectivity of our software tools with our services from your site’s network.
Installing Demo Configuration
A demo configuration for your CANlink mobile type is available at our Download
Center
Open the corresponding demo configuration file named like
clm36xx_Proemion_DemoConfig.DOD with the Proemion Configurator software.
Install the configuration to the device as described in CANlink mobile Device
Manual ¬ Configuration Update.
For further information on how to create a customized device configuration,
please refer to the CANlink mobile Device Manual ¬ Customizing Demo
Configuration File.
Perform a Functional Test
This work step is aimed to simulate the configured CAN messages with a CAN
Monitor software and its corresponding CAN-PC gateway. In this case you can
use the RM CAN Device Monitor and the CANview USB for a functional test. Other
CAN-PC gateways and software may also work for this test. Install the RM CAN
Device Monitor which can be found in the Download Center at folder
157002059_PROEMIONtools_CD\05_Utilities\01_RM CAN Device Monitor. Ensure that
the device is wired according to chapter Connecting the Device to a PC. Cyclic
send a few sample CAN messages which are configured within the installed
configuration of the CANlink mobile in the Receive CAN Messages section
.
Table 1. The following messages can be used for the test:
J1939-PGN| SPN| CAN ID| Type| DLC| Data Bytes|
Signal
---|---|---|---|---|---|---
61444| 190| 0x18F00400| Ext| 8| 00 00 00 80 25 00 00
00
| = 1200 rpm
J1939-PGN| SPN| CAN ID| Type| DLC| Data Bytes|
Signal
---|---|---|---|---|---|---
65262| 110| 0x18FEEE00| Ext| 8| 7D 00 00 00 00 00 00
00
| = 85°C
- Check the status LEDs of the CANlink mobile. The device should be powered on and indicate the reception of CAN messages. Please also refer to CANlink mobile Device Manual ¬ Indicator Elements. In case there is access to a real machine that is also transmitting the configured CAN message, the CANlink mobile 3600 can be also connected to the corresponding CAN bus.
Notice
CAN bus errors possible! Please make sure that the configured CAN baud rate is matching the controller CAN baud rate of the machine.
Check and adjust DataPortal
In the last step, you check and adjust the DataPortal appearance for your machine’s signals.
- Login to your DataPortal account
- Ensure that the customer default model with the demo PDC is assigned to the machine
- Check the displayed signals for your Machine within the DataPortal.
- Modify the machine details page with customized widgets according to your preferences. Please also refer to the DataPortal User Manual ¬ Widget Introduction/Catalog.
- To get further information about the creation and adjustment of customized PDC files, please refer to the DataPortal User Manual ¬ Administration Menu ¬ PDC Management. Version: 11.0.310
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>