Double-Wide Grill Side Freezer GSF30 Equipment Manual

June 8, 2024
Freezer

Double-Wide Grill Side Freezer GSF30 Equipment
McDonald-logo

Introduction

The Grill Side Freezer is designed to hold 10:1 and 4:1 boxes at the desired temperature during normal and peak sales periods. The sliding rail located in the top of unit is designed to store breakfast and protein items. Extra storage space is also provided at the bottom.

Operating-card

Note: Do not pack the unit with excess product as this might lead to improper air flow and operation of the unit

Installation Instructions

Location: The location of the meat freezer should be away from extreme heat and cold. A minimum of 2 inches clearance should be allowed around the freezer to facilitate adequate airflow to the compressor.

Leveling: In order to provide adequate condensate drainage, it is imperative that the unit be level. The floor where the unit is located should be level.

Location-Layout-&-Spacing

Caution: The refrigeration system is designed to operate in ambient temperatures of no more than 100°F.

Inspection: Upon receipt, examine the equipment carefully for any damage. If damage has occurred, notify the carrier and H&K immediately.

Unpacking: Remove the unit from the plastic wrap and untie the electrical cord by removing the holding tape. It is recommended that the unit remain crated until it has reached the installation location.

Plug: For international markets, the installer must install the plug on the power cord of the unit before the unit can be operated.

Instructions for Use

Power Source: Insert the plug of the freezer into a standard 120V AC 60 Hz. 15A outlet. The unit consists of one compressor. Other motors and heavy appliances should not be used on the same circuit with the freezer.

Start-Up: The freezer is turned “ON” by plugging the cord into the outlet. Check if the thermostat on the front is “ON”. Let the unit run for 1 hour before placing product in the freezer. Temperature Setting: The unit has been tested at the factory and the thermostat has been set to maintain a temperature between -10°F and 0°F.

Thermostat Adjustment: If the unit does not hold the desired temperature, the thermostat can be adjusted. To adjust thermostat, press the upper or lower button for 2 seconds and release. The set point will start blinking. Using the upper or lower button, adjust the temperature set point to the desired setting. Once the desired setting has been selected, do not touch any button and the controller will accept the new set point. Wait for 1 hour before readjusting the thermostat. Excessive tampering with the thermostat may  lead to service difficulties.

The unit can be forced into a manual defrost by pressing the lower button for more than 5 seconds. When the defrosting is initiated, the display will show DEF. Defrosting can be canceled again by pressing the push-button once more and the thermostat will return back to normal mode. When the defrost cycle is finished, the display will return to normal operation. This feature should be used when the coil freezes up due to excessive door openings and/or high humidity.

Note: When the unit comes out of defrost it will display a higher temperature for a short period of time, this is not the actual temperature in the freezer but the temperature inside the evaporator housing.

Condensate Disposal: The Grill Side Freezer does not require a floor drain, it has a built in condensate pan in the base of the condensing unit

Caution: Do not leave the self-closing rolling cover open for an extended period of time.

Caution: Excessive tampering with the temperature controller may lead to operating difficulties.

Cleaning

Exterior Cleaning: The exterior of the unit should be cleaned with a soap and water mixture and sanitized. Do not use abrasive cleaners to clean the exterior of the cabinet as this might damage the stainless steel finish. Do not use steel wool or any strong chemicals.

Interior Cleaning: The anodized aluminum interior of the refrigerator can be cleaned using a soft sponge and a soap-water mixture.

Caution: Use of abrasive pads to clean the unit will result in scratching and spoiling the finish of the unit. Refer to the GSF PM card for cleaning instructions before cleaning the unit.

Preventative Maintenance

Condenser: For proper operation of the condensing unit the condenser fins and fans should be cleaned and vacuumed every 3 months. The back or side grill is designed to be removable for this purpose.

Caution: Refer to the GSF PM card for preventative maintenance instructions before cleaning the condenser fins and fans on the unit.

Warranty

H&K Dallas, Inc. makes the following limited warranties to the original purchaser only for this equipment and replacement parts:

H&K warrants all components to be free of defects in material and workmanship, if properly installed, operated and maintained, for a period of one (1) year from the date of the delivery.

The company’s obligation under this warranty is limited to repairing or replacing any part or parts of the freezer determined to be defective by an authorized representative of H&K.

The company reserves the privilege of determining if such repairs are to be made in the field or at the H&K factory.

The company assumes no liability for expenses or repairs made by other parties except by written consent.

Corrections of such defects by repair or replacement shall constitute fulfillment of all company obligations to the purchaser.

H&K shall not be liable for loss, damages or expenses arising from misuse, abuse, alteration, accident or improper installation of the freezer such as:

Improper or unauthorized repair;
Failure to follow proper installation instruction;
Improper maintenance;
Damage in shipment;
Abnormal use;
Improper power supply;
Natural disaster;

Special Conditions
This warranty also does not cover:

Transportation or travel over 100 miles (160 Km) or travel time over 2 hours;
Overtime or holiday charges;
Consequential damages (the cost of repairing or replacing other property which is damaged), loss of time, profits, use of any other incidental damages of any kind.

Troubleshooting

PROBLEM CAUSE SOLUTION
Compressor will not start 1. Cord set not plugged in.

2. Thermostat stuck in open position.
3. Improperly wired.
4. Low voltage to unit.| 1. Plug in cord. 2. Replace thermostat. 3. Check wiring against diagram. 4. Correct the voltage
Unit runs continuously| 1. Undercharge.
2. Bad thermostat.
3. Dirty condense| 1. Add refrigerant.
2. Replace thermostat.
3. Clean condenser fins.
Condensation| 1. Leak in Gasket.
2. Wiring to condensate heater faulty.
3. Faulty condensate heaters.| 1. Reinstall gasket properly.
2. Rewire condensate heater.
3. Wire spare condensate heater.
Unit noisy| 1. Loose parts or mounting.
2. Fan motor bearings worn.
3. Fan blade bent.
4. Compressor assembly rattling.| 1. Tighten parts.
2. Replace motor.
3. Replace fan blade.
4. Check if mounted correctly and securely.
Temperature too high.| 1. Temperature setting too high
2. Condenser fins blocked.
3. Restricted airflow.
4. Door and/or lid open for extended periods.
5. Evaporator coil frozen.
6. Just finished defrost cycle.| 1. Reset temperature
2. Clean Fins.
3. Ensure air can circulate around the unit.
4. Close door and/or lid.
5. Put unit into manual defrost.
6. Wait for few minutes for temperature to fall within acceptable range

Unit Specifications – GSF30 Mobile Freezer

Mobile-freezer

Unit Layout – GSF30 Mobile Freezer

Mobile-Freezer-Unit-Layout

Parts Description and Identification

DESCRIPTION

|

H &K PART NO.

---|---

ROLLING COVER

|

GSF30.06A

TOP SLIDING RAIL

|

GSF30.03A

WIRE SHELVING RACK

|

GSF30.01A

FRONT DOOR

|

GSF30.02A

Parts Ordering and Service Procedure

Replacement Parts

DESCRIPTION

|

H &K PART NO.

---|---

CONDENSING UNIT

|

P-1-16-3

EXPANSION VALVE

|

P-1-12-11

SIGHT GLASS

|

P-1-21

DRYER

|

P-1-23

THERMOSTAT

|

E-4-3-160 DANFOSS E-4-3-162 DIXELL

FAN MOTOR ASSEBLY

|

E-6-003

DEFROST HEATER

|

E-5-26-2

Returns
Contact: H&K Dallas, Inc.
1343 South Henderson Ave.
Dallas, TX 75223
214-818-3552

Damages and Shortages
Upon receipt, examine the equipment carefully for any damage. If damage has occurred, notify the carrier and H&K Dallas, Inc. immediately.

Service
Contact: H&K Dallas, Inc.
1343 South Henderson Ave.
Dallas, TX 75223
214-818-3552

Disconnect all power sources before attempting any service or repair work.

Caution: A licensed technician should do all servicing and repair.

Terms
Contact: H&K Dallas, Inc.
1343 South Henderson Ave.
Dallas, TX 75223
214-818-3552

Wiring Diagram

User Interface

Change temperature setting: Pressing one of the buttons, shortly, will show the setpoint. While the set-point is shown blinking, you can increment the temperature by pressing the upper button or decrement the temperature by pressing the lower button. The display will return to normal mode 3 seconds after last key-press. The new set-point will be stored in the memory in ETC1H. Celsius /Fahrenheit: The temperature can be shown in either Celsius or Fahrenheit. To switch between Celsius and Fahrenheit, press the upper button for 5 seconds. The display will show C or F. To toggle the value, press the button once more. After 3 seconds, the display will switch to normal operation and store the new setting in memory in ETC1H.

Force defrost: The thermostat can be forced to start a defrost cycle by pressing the lower button for more than 5 seconds. When the defrosting is initiated, the display will show DEF. Defrosting can be canceled again by pressing the push-button once more and the thermostat will return back to normal mode. When the defrost cycle is finished, the display will return to normal operation.

Alarm handling: The display shows the alarm code + a value blinking, if applicable. When a value is shown, the display toggles between the error code and the value.

Alarm type Code Value
Sensor 1 defect E1
Sensor 2 defect E2
Sensor 3 defect E3
Compressor fault E4
Heater fault E5
Pot fault E6
Supply voltage low Ulo
Supply voltage high Uhi
Condenser hot E9
Condenser warm E10
High temperature alarm Hi Temperature
Low temperature alarm Lo Temperature
Communication error E13

This manual is for the exclusive use of licensees and employees of McDonald’s Systems Inc

Manufactured by:
H &K Dallas, Inc.
1343 South Henderson Ave.
Dallas, TX 75223
U.S.A.
Telephone: 214-818-3500
Fax: 214-818-3596

Distributed by:
H &K Dallas, Inc.
1343 South Henderson Ave.
Dallas, TX 75223
U.S.A.
Telephone: 214-818-3500
Fax: 214-818-3596

Double-Wide Grill Side Freezer GSF30 Equipment Manual – Download [optimized]
Double-Wide Grill Side Freezer GSF30 Equipment Manual – Download

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Freezer User Manuals

Related Manuals