PHILIPS MHC70-U-MP-4K ELITE MasterColor CDM ED17 Protected Elite Owner’s Manual

June 15, 2024
Philips

PHILIPS MHC70-U-MP-4K ELITE MasterColor CDM ED17 Protected Elite

Product Information

Specifications:

  • Product: MasterColor CDM ED17 Protected Elite 4200K
  • Cap-Base: E26 [Single Contact Medium Screw]
  • Operating Position: UNIVERSAL [Any or Universal (U)]
  • Features: ELITE 20,000 hour(s)
  • Color Code: 940 [CCT of 4000K]
  • Luminous Efficacy (rated): 92 lm/W
  • Color Designation: Cool White (CW)
  • Correlated Color Temperature: 4000 K
  • Color Rendering Index (CRI): 90
  • Power Consumption: 70.4 W
  • Lamp Current (Nom): 0.9 A
  • Voltage (Nom): 100 V
  • Bulb Finish: Clear Hard Glass ED17P [ED-17P Protected]
  • Bulb Material: Ceramic Metal Halide
  • Bulb Shape: ED-17
  • Mercury (Hg) Content (Max): 7.1 mg
  • Net Weight (Piece): 0.070 kg

Product Usage Instructions

Installation:

  1. Ensure the power source is turned off before installation.
  2. Insert the MasterColor CDM ED17 Protected Elite 4200K lamp into a compatible fixture with an E26 base.
  3. Screw the lamp securely into place, ensuring it is in the correct operating position.

Maintenance:
Regularly inspect the lamp for any signs of damage or discoloration. Replace the lamp if any abnormalities are detected to ensure optimal performance.

Safety Precautions:

  • Avoid touching the lamp with bare hands as oils from skin contact can affect performance.
  • Do not operate the lamp in environments with high humidity or extreme temperatures.

FAQ:

  • Q: What is the expected lifespan of the MasterColor CDM ED17 Protected Elite 4200K lamp?
    A: The lamp is rated for a lifespan of 20,000 hours.

  • Q: Can the MasterColor CDM ED17 Protected Elite 4200K lamp be used in outdoor fixtures?
    A: It is recommended to check the specific fixture’s compatibility for outdoor use before installing the lamp.

  • Q: Does the lamp require any special disposal methods?
    A: Yes, due to the mercury content, proper disposal methods should be followed according to local regulations.

MasterColor Elite Protected Ceramic Metal Halide ED-17 4200K Lamps provide excellent lumen maintenance and outstanding performance over time in a protected lamp.

Warnings and Safety

  • R “WARNING: These lamps can cause serious skin burn and eye inflammation from short wave ultraviolet radiation if the outer envelope ot the lamp is broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Certain lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available.” This lamp complies with FDA radiation performance standard 21 CFR subchapter J. (USA:21 CFR 1040.30 Canada: SOR/DORS/80-381)
  • WARNING: The arc tube of metal halide lamps is designed to operate under high pressure and at temperatures up to 1000ºC and can unexpectedly rupture due to internal or external factors such as a ballast failure or misapplication. If the arc-tube ruptures for any reason, the outer bulb may break and pieces of extremely hot glass might be discharged into the surrounding environment. If such a rupture were to happen, THERE IS A RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE. These lamps are designed to retain all the glass particles, should an arc tube rapture occur. The following operating instructions are recommended to minimize the occurrences.
  • The arc tube of metal halide lamps is designed to operate under high pressure and at temperatures up to 1000ºC and can unexpectedly rupture due to internal or external factors such as a ballast failure or misapplication. If the arc tube ruptures for any reason, the outer bulb may break and pieces of extremely hot glass might be discharged into the surrounding environment. If such a rupture were to happen, THERE IS A RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE. These lamps are designed to retain all the glass particles, should an arc tube rapture occur. The following operating instructions are recommended to minimize the occurrences.
  • RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE. Allowing lamps to operate until they fail is not advised and may increase the possibility of inner arc tube rupture.

Product data

General Information

  • Cap-Base E26 [Single Contact Medium Screw]
  • Operating Position UNIVERSAL [Any or Universal (U)]
  • Features ELITE
  • Life to 50% Failures (Nom) 20,000 hour(s)

Light Technical

  • Color Code 940 [CCT of 4000K]
  • Luminous Efficacy (rated) (Nom) 92 lm/W
  • Color Designation Cool White (CW)
  • Chromaticity Coordinate X (Nom) 0.441
  • Chromaticity Coordinate Y (Nom) 0.392
  • Correlated Color Temperature (Nom) 4000 K
  • Luminous Efficacy (Rated) (Min) 85 lm/W
  • Color rendering index (CRI) 90

Operating and Electrical

  • Power Consumption 70.4 W
  • Lamp Current (Nom) 0.9 A
  • Voltage (Nom) 100 V

Mechanical and Housing

  • Bulb Finish Clear
  • Bulb Material Hard Glass
  • Bulb Shape ED17P [ED-17P Protected]

Approval and Application

  • Mercury (Hg) Content (Max) 7.1 mg

Product Data

  • Order product name MHC70/U/MP/4K ELITE
  • Full product name MHC70/U/MP/4K ELITE
  • Order code 928601177901
  • Material Nr. (12NC) 928601177901
  • Net Weight (Piece) 0.070 kg
  • EAN/UPC – Product/Case 046677429959
  • Numerator – Packs per outer box 12
  • EAN/UPC – Case 50046677429954

Dimensional drawing

© 2024 Signify Holding All rights reserved. Signify does not give any representation or warranty as to the accuracy or completeness of the information included herein and shall not be liable for any action in reliance thereon. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract unless otherwise agreed by Signify. Philips and the Philips Shield Emblem are registered trademarks of Koninklijke Philips N.V.