APC Power Saving Back-UPS Pro User Manual
- June 7, 2024
- APC
Table of Contents
- APC Power Saving Back-UPS Pro User Manual
- Safety and General Information
- Inventory
- Install Power Chute TM Personal Edition Software
- Connect the Equipment
- Operation
- Alarms and System Errors
- Function Button Quick Reference
- Troubleshooting
- Specifications
- Battery Replacement
- Warranty
- APC by Schneider Electric IT Customer Support Worldwide
- FAQS
- VIDEO
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
APC Power Saving Back-UPS Pro User Manual
APC Power Saving Back-UPS Pro User Manual
Safety and General Information
Inspect the package contents upon receipt. Notify the carrier and dealer if there is any damage.
SAVE THESE INSTRUCTIONS
- This section contains important instructions that should be followed during installation and maintenance of the UPS and batteries.
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
- This UPS is intended for indoor use only.
- Do not operate this UPS in direct sunlight, in contact with fluids, or where there is excessive dust or humidity.
- Connect the UPS power cable directly to a wall outlet.
- Be sure the air vents on the UPS are not blocked. Allow adequate space for proper ventilation.
- Servicing of batteries should be performed or supervised by personnel knowledgeable about batteries and required precautions.
- A battery can present a risk of electric shock and burns by high short-circuit current.
- Failed batteries can reach temperatures that exceed the burn thresholds for touchable surfaces.
Failure to follow these instructions will result in death or serious injury.
Inventory
Connect the Battery
The UPS is shipped with the battery disconnected.
BR650MI /BR900MI
-
Remove the battery door.
-
Remove the battery. Connect the wire.
-
Push the battery into the unit.
-
Replace the battery door.
BR1300MI / BR1600MI
-
Remove the battery door.
-
Remove the battery.
RED LABEL ON TOP
-
Flip or turn the battery 180 degrees upward/downward to let green side of the label face up.
-
Push the battery into the unit.
GREEN LABEL ON TOP
-
Replace the battery door.
Install Power Chute TM Personal Edition Software
Use PowerChute Personal Edition software to configure the UPS settings. During a power outage, PowerChute will save any open files on your computer and shut it down. When power is restored, it will restart the computer. Note: PowerChute is only compatible with a Windows operating system. If you are using Mac OSX, use the native shutdown feature to protect your system. See the documentation provided with your computer.
Installation
Use the cable supplied with the Back-UPS to connect the data port on the Back-
UPS to the USB port on your computer. On the computer, go to www.apc.com
Search for “PowerChute Personal Edition” then click on “View Details” to
download the latest version of PCPE software. Click the download link and
select Software product. Select the appropriate operating system. Follow
directions to download the software.
Connect the Equipment
Battery backup and surge protected outlets
When the Back-UPS is receiving input power, the Battery Backup with Surge
Protection outlets will supply power to connected equipment. During a power
outage or other AC problems, the Battery Backup outlets receive power for a
limited time from the BackUPS. Connect equipment such as printers, fax
machines, scanners, or other peripherals that do not need battery backup power
to the Surge Protection Only outlets. These outlets provide full-time
protection from surges even if the Back-UPS is switched OFF.
BR650MI / BR900MI
BR1300MI /BR1600MI
USB and Serial Data port| To use PowerChute Personal Edition, connect the
supplied USB cable or an optional serial cable (not supplied).
---|---
Telephone Cable Surge Protected ports| Connect a telephone cable to the IN
port, and connect a modem to the OUT port
AC Power Input| Use a power cable to connect the unit to AC power
Battery Backup outlets with Surge Protection| During a power outage or other
AC problems, the Battery Backup outlets receive power for a limited time from
the Back-UPS. Connect critical equipment such as desktop computer, computer
monitor, modem or other data sensitive devices into these outlets.
Circuit Breaker| Use to reset the system after an overload condition has
occurred causing the circuit breaker to trip.
In/Out Ethernet surge-protected ports| Use an Ethernet cable to connect a
cable modem to the IN port, and connect a computer to the OUT port.
Surge Protected outlets| Use an Ethernet cable to connect a cable modem to the
IN port, and connect a computer to the OUT port.
Operation
Power saving display
The display interface can be configured to be continuously illuminated, or to
save energy, it can be configured to darken after a period of inactivity.
- Full Time Mode: Press and hold DISPLAY for two seconds. The display will illuminate and the Back-UPS will beep to confirm the Full Time mode.
- Power Saving Mode: Press and hold DISPLAY for two seconds. The display will darken and the Back-UPS will beep to confirm the Power Saving mode. While in Power Saving Mode, the display will illuminate if a button is pressed, it then darkens after 60 seconds of no activity.
Unit sensitivity
Adjust the sensitivity of the Back-UPS to control when it will switch to
battery power; the higher the sensitivity, the more often the Back-UPS will
switch to battery power.
- Ensure the Back-UPS is connected to AC power, but is OFF.
- Press and hold the POWER button for six seconds. The LOAD CAPACITY bar will flash on and off, indicating that the Back-UPS is in programming mode.
- Press POWER again to rotate through the menu options. Stop at selected sensitivity. The Back-UPS will beep to confirm the selection.
Generator Sensitivity
Default
Sensitive Loads
Low sensitivity| 156-300 Vac| Input voltage is extremely low or high. (Not
recommended for computer loads.)
---|---|---
Medium sensitivity (Default)| 176-294 Vac| The Back-UPS frequently switches
to battery power.
High sensitivity| 176-288 Vac| The connected equipment is sensitive to
voltage fluctuations
Front panel buttons and display interface
Use the three buttons on the front panel of the Back-UPS and the display
interface to configure the Back-UPS.
Front panel
- Mute button
- Power On/Off button
- Display button
- Display interface
| On Line: The Back-UPS is supplying conditioned AC power to connected
equipment
---|---
| Load Capacity: The load is indicated by the number of sections illuminated,
one to five. Each bar represents 20% of the load
| Battery Charge: The battery charge level is indicated by the number of
sections illuminated. When all five blocks are illuminated, the Back-UPS is at
full charge. When one block is filled, the Back-UPS is near the end of its
battery capacity, the indicator will flash and the Back-UPS will beep
continuously
| Overload: The power demand from the load has exceeded the capacity of the
Back-UPS
| Event: The event counter shows the number of events that occurred that
caused the Back-UPS to switch to on-battery operation.
| Automatic Voltage Regulation:
When illuminated, the Back-UPS is compensating for low input voltage
When illuminated, the Back-UPS is compensating for high input voltage.
| In: Input voltage. Out: Output voltage.
| System Error Detected: The system has an error. The error number will
illuminate on the display interface. See “System errors” on page 7.
| Mute: If the line through the speaker icon is illuminated, the audible alarm
has been turned off
| Replace Battery: The battery is nearing the end of its useful life. Replace
the battery as early as possible.
| On Battery: The Back-UPS is supplying battery backup power to the connected
equipment, it will beep four times every 30 seconds.
Alarms and System Errors
Audible indicators
Four Beeps Every 30 Seconds| Back-UPS is running on battery. You should
consider saving any work in progress.
---|---
Continuous Beeping| Low battery condition and battery run-time is very
low. Promptly save any work in progress, exit all open applications, and shut
down the operating system
Continuous tone| Battery Backup outputs are overloaded.
Chirps every 2 Seconds with the Load Capacity Bar flashing| Battery is
disconnected.
Continuous chirping with the Load Capacity Bar and Replace Battery icon
alternately flashing| Battery did not pass the automatic diagnostic test
and should be replaced as early as possible. Pressing the MUTE button pauses
the chirping
Status icons
If these icons are illuminated… | This may be the problem |
---|---|
The Back-UPS is operating on AC power, but is overloaded. Disconnect one of |
the items connected to the Back-UPS. If the Overload icon stops flashing, the
Back-UPS is no longer overloaded and will continue to operate normally.
| The Back-UPS is operating on battery power, but is overloaded. Disconnect
one of the items connected to the Back-UPS. If the Overload icon stops
flashing, the Back-UPS is no longer overloaded and will continue to operate
normally.
| The Back-UPS is operating on AC power, but the battery is not functioning
properly. Contact Schneider Electric IT (SEIT) Customer Service to order a
replacement battery. See “Battery Replacement” on page 11.
| The Back-UPS is operating on battery power and the battery power is getting
low. Shut down all connected equipment to avoid losing an unsaved data. When
possible, connect the Back-UPS to AC power to recharge the battery.
System errors
The Back-UPS will display these error messages. Except for errors F01 and F02, contact SEIT Technical Support.
F01| On-Battery Overload| Turn the Back-UPS off. Disconnect non-
essential equipment from the Battery Backup outlets and the turn Back-UPS on.
---|---|---
F02| On-Battery Output Short| Turn the Back-UPS off. Disconnect all
equipment from the Battery Backup outlets and the turn Back-UPS on. Re-connect
equipment one item at a time. If the output is tripped again, disconnect the
device that caused the error
F03| On-Battery Xcap Overload| Errors F03-F09 cannot be corrected by the
user, contact SEIT Technical Support for assistance.
F04| Clamp Short
F05| Charge Error
F06| Relay Welding
F07| Temperature
F08| Fan Error (for BR1600MI only)
F09| Internal Error
Function Button Quick Reference
Function | Button | Timing (seconds) | UPS Status | Description |
---|
Power
Power On| | 0.2| Of| Press POWER to start receiving input AC power. If AC
input power is not available, the Back-UPS will run on battery power.
Power Off| | 2| On| The Back-UPS is not receiving input AC power, but is
providing surge protection.
Display
Status Inquiry| | 0.2| On| Verify the status or condition of the Back-UPS. The
LCD will illuminate for 60 seconds. Press the button the toggle into various
information.
Full-Time/ PowerSaving| | 2| On| The LCD will illuminate and the Back-UPS will
beep to confirm the Full-Time mode. The LCD will darken and the Back-UPS will
beep to confirm the PowerSaving mode. While in Power-Saving Mode, the LCD will
illuminate if a button is pressed, then darkens after 60 seconds of no
activity.
Mute
General Status Enable/ Disable| | 2| On| Enable or disable the audible alarms.
The Mute icon will illuminate and the Back-UPS will beep one time. The Mute
function will not activate unless the BackUPS is operating on battery power.
Sensitivity| | 6| Of| The Load Capacity icon will blink, indicating that the
Back-UPS is in programming mode. Use the POWER button to scroll through Low,
Medium, and High, stop at selected sensitivity. The Back-UPS will beep to
confirm selection. See “Unit sensitivity” for details.
Self-Test (manual)| | 6| On| The Back-UPS will perform a test of the internal
battery. Note: This will happen automatically when the Back-UPS is turned ON
or when the Back-UPS previously detected a bad battery
Event Reset| | 0.2| On| When the Event screen is visible, press and hold
DISPLAY, then press POWER, to clear the detected error event counter.
Error Reset| | 2| Error| After an error has been identified, press POWER to
remove the visual indication and return to standby status.
| | | | |
Troubleshooting
Problem | Possible Cause | Corrective Action |
---|---|---|
Back-UPS will not switch on. | The Back-UPS is not connected to AC power. |
Ensure that the Back-UPS is securely connected to an AC outlet
The circuit breaker has been tripped.| Disconnect non-essential equipment from
the Back-UPS. Reset the circuit breaker. Re-connect equipment one item at a
time. If the circuit breaker is tripped again, disconnect the device that
caused the trip.
The internal battery is not connected.| Connect the battery.f
The AC input voltage is out of range.| Adjust the transfer voltage and
sensitivity range
The Back-UPS does not provide power during a AC power outage.| Ensure that
essential equipment is not plugged into a SURGE ONLY outlet.| Disconnect
equipment from the SURGE ONLY outlet and re-connect to a Battery Backup
outlet.
The Back-UPS is operating on battery power, while connected to AC power.| The
plug has partially pulled out of the wall outlet, the wall outlet is no longer
receiving AC power, or the circuit breaker has been tripped.| Ensure that the
plug is fully inserted into the wall outlet. Ensure that the wall outlet is
receiving AC power by checking it with another device.
The Back-UPS is performing an automatic self test.| No action is necessary.
The AC input voltage is out of range, the frequency is out of range, or the
waveform is distorted| Adjust the transfer voltage and sensitivity range.
The Back-UPS does not provide the expected amount of backup time.| Battery
Backup outlets may be fully or improperly loaded.| Disconnect non-essential
equipment from the Battery Backup outlets and connect the equipment to SURGE
outlets.
The battery was recently discharged due to a power outage and has not fully
recharged.| Charge the battery cartridge for 16 hours
The battery has reached the end of its useful life.| Replace the battery
The REPLACE BATTERY indicator is illuminated.| The battery has reached the end
of its useful life| Replace the battery as early as possible.
The OVERLOAD indicator is illuminated.| The equipment connected to the Back-
UPS is drawing more power than the Back-UPS can provide.| Disconnect non-
essential equipment from the Battery Backup outlets and connect the equipment
to SURGE outlets
The SYSTEM ERROR indicator is illuminated, all the front panel indicators are
flashing.| There is an internal error.| Determine which internal error message
is displayed by matching the number displayed on the LCD with the
corresponding Error Message (see “System errors”) and contact SEIT Technical
Support.
Specifications
Model | BR650MI | BR900MI | BR1300MI | BR1600MI |
---|---|---|---|---|
VA | 650 VA | 900 VA | 1300 VA | 1600 VA |
Maximum Load | 390 W | 540 W | 780 W | 960 W |
Nominal Input Voltage | 220 – 240 Vac | |||
Online Input Voltage Range | 176 – 294 Vac | |||
Automatic Voltage Regulation | Boost by +11.5% when input voltage |
drops below limit
Trim by -11.5% when input voltage exceeds limit
Frequency Range| 50/60 Hz ± 3 Hz
Battery Type| Lead acid, 12V with 1 battery| Lead acid, 12V with 2
batteries
On-battery Waveshape| Step-approximated sine-wave
Typical Recharge Time| 12 hours| 16 hours
Transfer Time| 8 ms (typical), 10 ms (maximum)
On Battery Runtime| Go to: www.apc.com
Interface| USB
Operating Temperature| 08 to 408 C (328 to 1048 F)
Storage Temperature| -58 to 458 C (238 to 1138 F)
IP Rating| IP20
Unit Dimensions| 19 x 9.1 x 31 cm
(7.5 x 3.6 x 12.2 in)
| 25 x 10 x 38.2 cm
(9.8 x 3.9 x 15 in)
Unit Weight| 6.8 kg (15 lbs)| 7.2 kg (15.9 lbs)| 10.2 kg (22.5 lbs)| 11.0 kg (24.3 lbs)
Battery Replacement
RISK OF HYDROGEN SULPHIDE GAS AND EXCESSIVE SMOKE
- Replace the battery at least every 5 years.
- Replace the battery immediately when the UPS indicates battery replacement is necessary.
- Replace battery at the end of its service life.
- Replace batteries with the same number and type of batteries as originally installed in the equipment.
- Replace the battery immediately when the UPS indicates a battery over-temperature condition, or UPS internal over-temperature, or when there is evidence of electrolyte leakage. Power off the UPS, unplug it from the AC input, and disconnect the batteries. Do not operate the UPS until the batteries have been replaced.
Failure to follow these instructions can result in minor or moderate injury and equipment damage.
The battery typically lasts for 3 to 5 years, a shorter period if subjected to frequent outages or elevated temperatures. Battery replacement parts for Back- UPS BR650MI is APCRBC110, for BR900MI is APCRBC164, for BR1300MI is APCRBC165, and for BR1600MI is APCRBC166. Delaying the replacement of parts may corrode the batteries in the cartridge. Recycle spent battery cartridges.
Warranty
The standard warranty is three (3) years from the date of purchase, valid in European Community. For all other regions, the standard warranty is two (2) years from the date of purchase. Schneider Electric IT (SEIT) standard procedure is to replace the original unit with a factory reconditioned unit. Customers who must have the original unit back due to the assignment of asset tags and set depreciation schedules must declare such a need at first contact with an SEIT Technical Support representative. SEIT will ship the replacement unit once the defective unit has been received by the repair department, or cross-ship upon the receipt of a valid credit card number. The customer pays for shipping the unit to SEIT. SEIT pays ground freight transportation costs to ship the replacement unit to the customer.
APC by Schneider Electric IT Customer Support Worldwide
For country specific customer support, go to the APC by Schneider Electric Web site, www.apc.com.
FAQS
How do I connect the battery?
The battery is shipped disconnected. To connect the battery, follow these steps: 1. Remove the battery door. 2. Remove the battery. Connect the wire. 3. Push the battery into the unit. 4. Replace the battery door.
How do I remove the battery?
To remove the battery, follow these steps: 1. Remove the battery door. 2. Disconnect the wire from the terminal block on the back of the UPS (see Figure 1). 3. Slide out the battery and lift it out of its compartment (see Figure 2). Figure 1: Disconnecting wire from terminal block on back of UPS Figure 2: Removing and lifting out battery
What is the voltage input on this unit?
It’s 220/230v and has been working for a while without any issue.
Can it do 240v?
Yes, it can.
What is the max load in Watts that this units can provide?
865 Watts
How long does APC battery backup take to charge?
The Back-UPS battery charges fully during the first 24 hours while connected to AC power.
How many years does a UPS battery last?
There are a few different factors that can contribute to the lifespan of a UPS battery. On average, a battery will last anywhere from 3-5 years. But, some batteries can last much longer, while others might die on you in a very short amount of time.
How long can a TV run on a UPS?
You can power a TV with an Uninterrupted Power Supply (UPS), and depending on the size (and cost) of the power supply it may keep the TV going for anywhere from 15 minutes to 2 hours. It’s smart to use a UPS for your TV (or other expensive electrical equipment) as cost-effective insurance.
Should a UPS always be plugged in?
Your UPS should always be plugged into an electric socket and your devices should be plugged into the UPS when you’re using them. To connect the UPS, please refer to the user manual provided in the UPS box.
Can UPS be used 24 7?
UPS are designed to be used 24/7 , there is no need to turn them off. You may wish to when the computer is switched off in order to save electricity, but technically there is no need to power off.
Can you use APC UPS without battery?
Yes. The outlets will operate without any battery backup protection. Surge protection will continue to function normally. If your model has a display screen, there is a button on the front panel that can be used to mute the alarm.
What affects UPS battery life?
Regardless of how or where a UPS is deployed, and what size it is, there are four primary factors that affect battery life: ambient temperature, battery chemistry, cycling and service. The rated capacity of a battery is based on an ambient temperature of 25°C (77°F).
Can UPS Explode?
Overcharging with a float voltage that is too high can cause excessive hydrogen and oxygen gases and can lead to internal dryout that, once accelerated, can cause thermal runaway – resulting in failure or even fire and explosion.
Is it OK to not unplug UPS?
If you have just turned off your PC because you are done with your work and there is no power problem you can turn the UPS via the power button. As long as there is input power coming in to your UPS, it will charge the battery.
Is it okay to turn on UPS everyday?
the UPS is designed to be left on all of the time and I don’t see a benefit to turn it off each day. also, every time you turn the UPS on, it will do a UPS self test and if done too often, this will drain the battery a tiny bit unnecessarily. if you do this a few times a day for a year, then it adds up.
What happens if a UPS fails?
Usually, the UPS control logic will detect the failing output voltage / frequency as the fault occurs. Immediately this will signal the static switch control system to transfer the load to the bypass line in a make- before-break fashion.
Is doing 100 pushups a day good?
Doing pushups every day can be effective if you’re looking for a consistent exercise routine to follow. You will likely notice gains in upper body strength if you do pushups regularly. For the best results, continue to add variety to the types of pushups you do.
VIDEO
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>