TECHNICAL DATA

Model| Watts| Lumens| Beam
Angle| Long Life| PF| CRI| Input Power| Operation
Temperature| Dimension
---|---|---|---|---|---|---|---|---|---
V1-4961| 50W| 8000| 100| 30000H| >0.9| >70| AC:220-240V.50Hz| -20 to +40°c| 241.5×197.5x46mm
VT-49161| 100W| 16000| 100| 30000H| >0.9| >70| AC:220-240V.50Hz| -20 to +40°c| 299×247.5×49.5mm
VT-49261| 200W| 32000| 100| 30000H| >0.9| >70| AC:220-240V.50Hz| -20 to +40°c| 458.5x371x57mm

WARNING

  1.  Please make sure to turn off the power before starting the installation.
  2. The light source of this luminaire is not replaceable, when the light source reaches its end of life the whole luminaire should be replaced.
  3. If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard.
  4. Proper grounding should be ensured throughout the installation.
  5. Installation must be performed by a qualified electrician.
  6. Terminal block not included.

This marking indicates that this product should not be disposed of with other household wastes.
Caution , risk of electric shock.

INSTALLATION DIAGRAM

V-TAC LED Floodlight series - DIAGRAM

Minimum distance from lighted objects 1m.

Replace any cracked protective shield.

WIRING DIAGRAM
Neutral Supply can be Blue or Black
Ground Supply can be Green-yellow
Live Supply can be Red or Brown

INTRODUCTION & WARRANTY

Thank you for selecting and buying the V-TAC product. V-TAC will serve you the best. Please read these instructions carefully before starting the installing and keep this manual handy for future reference. If you have any other queries, please contact our dealer or local vendor from whom you have purchased the product. They are trained and ready to serve you at your best. The warranty is valid for 5 years from the date of purchase. The warranty does not apply to damage caused by incorrect installation or abnormal wear and tear. The company gives no warranty against damage to any surface due to incorrect removal and installation of the product. The products are suitable for 10-12 Hours of Daily operation. Usage of product for 24 Hours a day would void the warranty. This product is warranted for manufacturing defects only.

INSTALLATION INSTRUCTION

• DO NOT USE IN AREAS WITH LIMITED VENTILATION OR OUTSIDE THE RATED AMBIENT TEMPERATURE RANGE. CONNECT WITH  WATERPROOF CABLE HOUSE ONLY. ENSURE ELECTRICITY IS SWITCH OFF BEFORE INSTALLATION.
• Please do not mount to a surface that is prone to vibrations.*Remove the screw and the bracket afterward. (Figure 1)Before drilling, mark the hole position for fixing the bracket onto the wall (Screw not supplied). (Figure 2)
• Screw the retaining bracket to the wall with a suitable quantity of screws. (Figure 4)
• Mount the bracket back to the fixture. Adjust the floodlight according to the desired position. Tighten the screw. (Figure 5) Connect your main cable (H05RN-F3G1.0mm2  Recommended) with the input lead of our product through the waterproof junction box. Note, the line (-) of the lead. (Need to use the junction box of IP65 or above, ensure to tighten the waterproof screw) Switch on the power to make sure if the product is working. Adjust the direction angle as per your preference. (Figure 6)