Munters RLC-1LV Light Dimmer User Manual
- June 7, 2024
- Munters
Table of Contents
RLC-1LV
Manual for use and maintenance
RLC-1LV
Light Dimmer
Ag/MIS/UmGb-2586-05/18 Rev 1.0
P/N: 116099
RLC-1LV
Manual for use and maintenance
Revision: N.1.0 of 04.2019
Product Software: N/A
This manual for use and maintenance is an integral part of the apparatus
together with the attached technical documentation.
This document is destined for the user of the apparatus: it may not be
reproduced in whole or in part, committed to computer memory as a file, or
delivered to third parties without the prior authorization of the assembler of
the system.
Munters reserves the right to effect modifications to the apparatus in
accordance with technical and legal developments.
Introduction
Disclaimer
Munters reserves the right to make alterations to specifications, quantities, dimensions, etc. for production or other reasons, subsequent to publication. The information contained herein has been prepared by qualified experts within Munters. While we believe the information is accurate and complete, we make no warranty or representation for any particular purposes. The information is offered in good faith and with the understanding that any use of the units or accessories in breach of the directions and warnings in this document is at the sole discretion and risk of the user.
Introduction
Congratulations on your excellent choice of purchasing a Hanging Bird Scale!
In order to realize the full benefit from this product, it is important that
it is installed, commissioned, and operated correctly. Before installation or
using the fan, this manual should be studied carefully. It is also recommended
that it is kept safely for future reference. The manual is intended as a
reference for installation, commissioning, and day-to-day operation of the
Munters Controllers.
Notes
Date of release: July 2010
Munters cannot guarantee to inform users about the changes or to distribute
new manuals to them.
NOTE All rights reserved. No part of this manual may be reproduced in any
manner whatsoever without the expressed written permission of Munters. The
contents of this manual are subject to change without notice.
Precautions
Grounding
-
Always connect temperature and sensor shields to earth ground. Avoid mixing high voltage wiring with sensor and low voltage wiring.
-
Keep the controller as far as possible from heavy contactor boxes and other sources of electrical interference.
-
Do not connect communication wire shields, which go from one house to another at both ends.
Connect them at one end only. Connection at both ends can cause ground loop currents to flow, which reduces reliability. -
The COM connection for communications is not the shield wire. The COM, RX, and TX wires must connect to each other at all controllers.
Filtering
- If this installation includes a power inverter to drive variable speed fans, install an EMI filter in front of the inverter, according to the specifications provided by the inverter manufacturer. Refer to the inverter documentation.
Checking the Battery Level
- Check the battery once a year. The output must be 2.7 volts (minimum). Authorized personnel only must replace the battery if the output is below the minimum required level or every five years.
Introduction to the RLC-1LV
The Light Control enables the user to determine the light intensity for every growth day and change them as many times as needed. The RLC-1 LV controls:
- a light dimmer
- ON/OFF operations
Main Display
Day | Light | Time |
---|---|---|
028 4 | 8.6% | 12:02 |
This display shows the present growth’s day actual light intensity by percentage and the actual time.
Setting Mode
- To set the different options available, use the menu.
- Press Select and the main menu appears.
- Press the Up arrow to display the next menu item and the Down arrow to display the previous item.
- To return to the main display, press Select continuously for a couple of seconds.
MENU
1.- LIGHT TABLE
Menu
RLC-1LV has the following functions:
- Light Table
- Growth Day
- Auto/Manual Mode
- Time Update
- Main Display
Light Table
Every growth day has a “Light Cycle”, which is composed of one or more
programming lines day.
The RLC-1LV Light Table offers up to 99 programming lines. Each program line
is composed of four events:
- Day
- Time
- -%-
- Min.
Program each event individually by pressing Select until the cursor is
below the column of the event to be programmed.
Light Table-Example
The Light Table lists the different settings for each growth day.
#| Day| Time| -Vo-| Min
---|---|---|---|---
1| 1| 8:10| 80| 20
2| 1| 10:20| 100| 10
3| 1| 13:10| 60| 40
4| 1| 18:00| 0| 50
5| 7| 7:50| 70| 18
6| 7| 9:50| 99| 11
7| 7| 14:20| 78| 22
8| 7| 17:50| 8| 13
| | …| …| …
10| …| …| …| …
11| …| …| …| …
12| …| …| …| …
13| 42| 7:00| 70| 40
14| 42| 9:00| 95| 15
15| 42| 14:00| 65| 50
16| 42| 17:00| 0| 60
…| …| …| …| …
99| …| …| …| …
In the above example:
- The first light cycle is composed of four programming lines from 1 to 4, and is valid from Day 1 to Day 6.
- The second light cycle is also composed of 4 programming lines from 5 to 8, and is valid from Day 7 to Day 42.
NOTE The time frame for each program can be set with 10 minutes
resolution only.
Programming a Light Cycle
To program an RLC-1LV:
1. In the main display, press Select.
The screen displays:
MENU
1.- LIGHT TABLE
2. Press Select.
The screen displays:
| Time| %| Min
---|---|---|---
5| 11:20| 80| 10
5| 17:20| 0| 50
-
# #: The program line
-
Day : The growth day number
o Minimum 0; Maximum 255 -
Time: The dimming starting time
o Hour: Minimum 00, Maximum 23
o Minutes: Minimum 00, Maximum 50 -
-%-: The light intensity target
o Minimum 0, Maximum 100 -
Min: Represents the time interval (in minutes) during which the light intensity changes from the actual setting to the target setting.
o Minimum 0, Maximum 255
In the example above:
- When the light turns on, it takes 10 minutes to get to 80% intensity.
- When the light turns off, it takes 5 minutes to go down to 0%.
NOTE Lights turn ON at the scheduled time, increasing to the intensity target
during the time interval.
Lights begin to turn OFF before the scheduled time. In the example above:
Lights begin to turn on at 11:20 and reach the target intensity at
11:30.
Lights begin to turn off at 17:15 and reach the target intensity at 1
7:20.
Relay
When there is 0% output the relay activates. The relay is normally open and
normally closed.
NOTE When the RLC-1LV reaches the last programmed line, it continues
working in that last light cycle does not automatically return to programming
line number
Growth Day
* MENU
2. GROWTH DAY
With this option, the light intensity can be modified according to the desired program line.
-
From the main display, press Select.
-
Press the Up or Down arrow; the growth day option is displayed.
GROWTH DAY UPDATE
ENTER GROWTH DAY: 32 -
Press Select.
-
The cursor is now under the actual growth day.
-
To set the desired growth day, press the Up or Down arrows.
-
To return to the main display, press Select.
Auto/Manual Mode
This function enables manually modifying the light intensity. The results are
seen immediately. When the
RLC-1LV is reset to auto, it resumes working as programmed.
-
From the main display press Select.
-
Press the Up or Down arrow until the display shows:
MENU *
3. AUTO/MANUAL MODE -
Press Select. The display shows:
AUTO/MANUAL MODE
SELECT ( / ).:AUTO -
Using the Up or Down arrows, select Manual.
-
Press Select to return to the main display.
-
Use the Up or Down arrow key to adjust the light intensity.
Time Update
With this option, you can update the RLC-1LV internal real-time clock.
-
From the main display press Select.
-
Press the Up or Down arrows until the display shows:
MENU
4. TIME UPDATE -
Press Select; the display shows
TIME UPDATE
ENTER TIME…..13:50
The cursor is under the “hours”.
-
Set the hour with the Up or Down arrows.
-
Press Select.
Now the cursor is under the “minutes”. -
Set the minutes with the Up or Down a rrows.
-
Press Select , to return to the main display.
Main Display
Day | Light | Time |
---|---|---|
028 | 48.6% | 12.02 |
NOTE In case of a power failure or if the RLC-1LV is accidentally unplugged, the RLC-1LV is equipped with a battery, ensuring that the program is not erased.
Installation
WARNING! The RLC-1LV must be installed by an authorized electrician. Disconnect the power to avoid electrical shock and damage.
-
Mount the RLC-1LV on the wall, using the four supplied screws and plates, through the mounting holes.
-
Place the required cables through the cable holders at the bottom of the unit.
-
Connect the wires according to the wiring diagrams.
NOTE The wires that supply power to the RLC-1LV also supply power to the Light. Ensure that you use the correct wires for the load. -
To connect the slave wire to the controller, use two-conductor #18 #24 gauge cables.
-
Close the RLC-1LV enclosure lid. Use RTV silicone or an equivalent sealant to seal the cable holders.
-
Operate the RLC-1LV and the controller for a few hours and re-check for proper operation.
Technical Details
Input Power Voltage | Single-phase 110 VAC (the USA and Canada) |
---|
Single-phase 240 VAC (Outside the US and Canada)
| 0.2 Amp, 50 – 60 Hz
Output| 0-10 V, 30 mA
Operating Temperature Range| -10° to +50 C° (+14° to +125° F)
Enclosure| Water and dust-tight (IP55)
Fuses| Main Fuse: 315 mA
Environmental Protection
Recycle raw materials instead of disposing of as waste. Sort the controller, accessories, and packaging for environmental-friendly recycling. The plastic components are labeled for categorized recycling.
Warranty
Warranty and technical assistance
Munters products are designed and built to provide reliable and satisfactory performance but cannot be guaranteed free of faults; although they are reliable products they can develop unforeseeable defects and the user must take this into account and arrange adequate emergency or alarm systems if failure to operate could cause damage to the articles for which the Munters plant was required: if this is not done, the user is fully responsible for the damage which they could suffer
Munters extends this limited warranty to the first purchaser and guarantees
its products to be free from defects originating in manufacture or materials
for one year from the date of delivery, provided that suitable transport,
storage, installation, and maintenance terms are complied with. The warranty
does not apply if the products have been repaired without express
authorization from Munters, or repaired in such a way that, in Munters’
judgment, their performance and reliability have been impaired, or incorrectly
installed, or subjected to improper use. The User accepts total responsibility
for incorrect use of the products. The warranty on products from outside
suppliers fitted to RLC-1LV, (for example cables, lights, etc.) is limited to
the conditions stated by the supplier: all claims must be made in writing
within eight days of the discovery of the defect and within 12 months of the
delivery of the defective product. Munters has thirty days from the date of
receipt in which to take action and has the right to examine the product at
the customer’s premises or at its own plant (carriage cost to be borne by the
customer).
Munters at its sole discretion has the option of replacing or repairing, free
of charge, products which it considers defective, and will arrange for their
despatch back to the customer carriage paid. In the case of faulty parts of
small commercial value which are widely available (such as bolts, etc.) for
urgent despatch, where the cost of carriage would exceed the value of the
parts, Munters may authorize the customer exclusively to purchase the
replacement parts locally; Munters will reimburse the value of the product at
its cost price.
Munters will not be liable for costs incurred in demounting the defective
part, or the time required to travel to site, and the associated travel costs.
No agent, employee or dealer is authorized to give any further guarantees or
to accept any other liability on Munters’ behalf in connection with other
Munters products, except in writing with the signature of one of the Company’s
Managers.
WARNING: In the interests of improving the quality of its products and
services, Munters reserves the right at any time and without prior notice to
alter the specifications in this manual.
The liability of the manufacturer Munters ceases in the event of:
- dismantling the safety devices;
- use of unauthorized materials;
- inadequate maintenance;
- use of non-original spare parts and accessories.
Barring specific contractual terms, the following are directly at the user’s expense:
- preparing installation sites;
- providing an electricity supply (including the protective equipotential bonding (PE) conductor, in accordance with CEI EN 60204-1, paragraph 8.2), for correctly connecting the equipment to the mains electricity supply;
- providing ancillary services appropriate to the requirements of the plant on the basis of the information supplied with regard to installation;
- tools and consumables required for fitting and installation;
- lubricants are necessary for commissioning and maintenance.
It is mandatory to purchase and use only original spare parts or those
recommended by the manufacturer.
Dismantling and assembly must be performed by qualified technicians and
according to the manufacturer’s instructions.
The use of non-original spare parts or incorrect assembly exonerates the
manufacturer from all liability.
Requests for technical assistance and spare parts can be made directly to the
nearest Munters office. A full list of contact details can be found on the
back page of this manual.
Munters Israel: 18 HaSivim Street
Petach-Tikva 49517, Israel
Telephone: +972-3-920-6200
Fax: +972-3-924-9834
support@munters.co.il
Australia Munters Pty Limited, Phone +61 2 8843 1594, Brazil Munters Brasil
Industria e Comercio Ltda, Phone +55 41 3317 5050, Canada Munters Corporation
Lansing, Phone +1 517 676 7070, China Munters Air Treatment Equipment
(Beijing) Co. Ltd,
© Munters AB, 2018
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>