electriQ Compressor Dehumidifier With Digital Humidistat User Manual
- June 7, 2024
- ElectriQ
Table of Contents
- SAFETY INSTRUCTIONS
- INSTALLATION
- FEATURES
- PARTS
- CONTROL PANEL
- HUMIDITY LEVEL & TIMER 2 DIGIT DISPLAY
- QUICK REFERENCE GUIDE
- OTHER FEATURES AND INDICATORS
- POSITIONING THE DEHUMIDIFIER
- WATER DRAINAGE
- CARE AND MAINTENANCE
- TROUBLESHOOTING
- TECHNICAL DATA
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
USER MANUAL
COMPRESSOR DEHUMIDIFIER WITH DIGITAL HUMIDISTAT
CD12P – 12 Litres per day
Thank you for choosing electriQ.
Please read this user manual before using this innovative dehumidifier and
keep it safe for future reference Visit our page
www.electriQ.co.uk for our entire range of
Intelligent Electricals.
SAFETY INSTRUCTIONS
IMPORTANT
-
Carefully read the instructions before operating the unit
-
This appliance is for indoor use only and intended for use in a domestic environment only. Any other use is not recommended by the manufacturer and may cause fire,
electrical shocks or another injury to user or property. -
Rating: This unit must be only connected to a 220-240 V / 50 Hz earthed outlet.
-
Installation must be in accordance with the regulations of the country where the unit is used.
-
If you are in any doubt about the suitability of your electrical supply have it checked and if necessary, modified by a qualified electrician.
-
This dehumidifier has been tested and is safe to use. However, as with any electrical appliance – use it with care.
-
Disconnect the power before dismantling, assembling or cleaning.
-
Avoid touching any moving parts of the appliance.
-
Never insert fingers, pencils or any other objects through the guard
-
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities. It is also not intended for use by those with a
lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. -
Do not leave children unsupervised with this appliance.
-
Do not clean the unit by spraying it or immersing it in water.
-
Never connect the unit to an electrical outlet using an extension cord. If a power outlet is not available, one should be installed by a qualified electrician.
-
Never operate this appliance if the cord, power adapter or plug is damaged. Ensure the power cord is not stretched or exposed to sharp objects/edges.
-
A damaged power supply cord should be replaced by the manufacturer or a qualified electrician in order to avoid a hazard.
-
Any service other than a regular cleaning or filter replacement should be performed by an authorized service representative. Failure to comply could result in avoided
warranty. -
Do not use the appliance for any purpose other than its intended use.
-
Do not tilt the unit while in use. The unit is designed to work only in a vertical position.
-
This dehumidifier must always be stored and transported upright, otherwise irreparable damage may be caused to the compressor; if in doubt we suggest waiting at least 24 hours before starting the unit.
-
Avoid restarting the dehumidifier unless 5 minutes have passed since being turned off. This prevents damage to the compressor.
-
Never use the plug as a switch to start or turn off the dehumidifier. Use the provided ON/OFF switch located on the control panel.
-
Always place the unit on a dry and stable surface.
-
The appliance should not be installed in the laundry or wet rooms where the humidity is higher than 85% RH
-
Do not dry laundry above the unit to prevent water from entering the dehumidifier. Place the laundry at least 1 meter away from your dehumidifier.
-
Before moving the appliance the water tank should be emptied.
-
The handle on the appliance is designed to aid in its movement and should not be used to support the full weight of the dehumidifier. When carrying the unit, it should be kept upright and sufficiently supported from its base.
-
The handle should not be used if there is any signs of damage to its fixings.
-
The appliance must be placed in a room without sources of ignition (for example open flames, an operating gas appliance or an operating electric heater).
-
R290 refrigerant gas complies with European environmental directives.
-
R290 has a low GWP (Global Warming Potential) of 3.
-
The CD12P contains about 55g of R290 refrigerant gas.
-
Do not use or store the appliance in an unventilated space with an area smaller than 2.6m2 per unit.
-
If the appliance is installed, used or stored in an unventilated room, the room must be such as to prevent stagnation of possible leaks of refrigerant gas as there could be a
danger of fire or explosion should the refrigerant come into contact with electric heaters, stoves or other sources of ignition. -
Refrigerant gas may be odorless.
-
Do not use the product and contact the retailer for advice if damage has occurred to the unit which may have compromised the refrigerant system.
-
Any repairs or maintenance must only be carried out on the unit by a suitably qualified engineer. Before opening and servicing the unit the authorized engineer must be in possession of a copy of the manufacturer’s service manual and must follow the safety information contained within it to ensure all hazards are minimized.
-
The refrigerant system should not be perforated or punctured.
-
Do not place the unit next to heat sources (e.g. electrical fires, fireplaces, etc.)
-
Avoid mishandling the dehumidifier. Dropping, throwing the unit can cause damage to its internals and increases the risks of operating it.
-
Do not store or use gasoline, petrol, paint, solvents or other flammable vapors or liquids in the vicinity of this dehumidifier or any other appliance.
-
This dehumidifier must not be used in spaces where there is a high concentration of gases, solvent, or other volatile organic compounds; in very dusty environments; in any domestic, commercial or industrial environment where the air composition is flammable.
ENERGY-SAVING AND UNIT SAFETY PROTECTION TIPS
- Do not cover or restrict the airflow from the outlet or inlet grills. Do not operate and follow troubleshoot procedure if the self-opening louvers do not open on power.
- For maximum performance, the minimum distance from a wall or objects should be 20 cm
- Keep the filters or grills of the unit clean. Under normal conditions, filters or grills should only need cleaning once every three weeks (approximately).
- Since the filters remove airborne particles, more frequent cleaning may be necessary, depending on the air quality. Vacuum both mesh and optional carbon filters and wash the mesh filters with hot soapy water and dry them before placing them back in the unit.
QUICK VISUAL SAFETY GUIDE ON WHERE OR WHEN NOT TO USE YOUR DEHUMIDIFIER
INSTALLATION
Remove any water from within the water tank before starting the unit. In order to save energy do not open windows or doors while the unit is running. Place the unit on a hard/flat surface. On first use run the unit continuously for 24 hrs.
TO REDUCE NOISE LEVELS:
Place a piece of carpet or a rubber mat under the unit to reduce any
vibrations while the unit is running.
The CD12P dehumidifier uses compressor technology to extract water from the
environment. Compressor dehumidifiers are ideal for normal domestic or office
environments which are heated during the winter months and maintain a
temperature above 12-15⁰C.
The dehumidifiers are easy to move around on castors and are designed to
extract unwanted humidity while saving money due to their power-saving logic.
They feature an intelligent humidistat where the desired relative humidity can
be adjusted in increments of 5% between 40 and 80% ensuring your room is not
dried too much and power is not wasted.
FEATURES
Your dehumidifier belongs to the electriQ dehumidifier range featuring power- saving logic.
- Easy to use controls
- Great for up to 3-bed houses
- A cost-effective way to combat mold, condensation, and damp
- Dries laundry more efficiently than a tumble dryer
- Designed to complement any modern space
- Castors for improved mobility
- Intelligent CPU controlled digital humidistat with 35-80% RH and room humidity display
- 24 hours start/stop the timer
- Tank operation or permanent drainage option with splash-proof tank
- Tank full alarm & auto-stop function
PARTS
OPTIONAL
CONTROL PANEL
| POWER
Turn the appliance on/off
---|---
| MODE Button
Select the function of the unit between SMART and FAN modes. The LEDs next to
the button will show which mode is selected.
SMART MODE: The unit will default to SMART mode the first time it is
switched on and remains in this mode until another program is chosen. In smart
mode, it will default to aim for a relative humidity of 50-55%.
FAN: Only the fan will run and water is not extracted.
| HUMIDITY SETTING
Press the UP and DOWN buttons to select the desired relative humidity level,
the default relative humidity is 55%. When a relative humidity of 35% is
selected, the compressor will not stop until the water tank is full.
| HUMIDITY INDICATOR Button
When the appliance is started, the indicator light will turn on automatically.
The indicator light color will change according to the humidity condition
RED: High humidity, RH≥70%
ORANGE: Comfortable, 70%> RH ≥60%
GREEN: Dry, RH<60%
The ”Humidity Indicator light” button can be pressed to turn on/off the
indicator light.
Note: It can take around 2 minutes after the humidity has changed into a
different color bracket for the indicator will change the color e.g. if
humidity drops to 55% may take 2 minutes before the indicator changes to
green
| TIMER
Press the TIMER button to program the timer. When the timer is activated the
“TIMER” light will be illuminated. Before programming the timer, ensure the
timer function has not been activated (the light must be off). The following
timer programs are available.
DELAYED POWER-ON FUNCTION: With the appliance in standby, press the TIMER
button, then use the UP and DOWN buttons to set in how many hours time do you
require the unit to start (0~24 hours).
DELAYED POWER-OFF FUNCTION: While the appliance is running with the
desired settings, press the TIMER button, then use the UP and DOWN buttons to
set in how many hours time you require the unit to stop (0~24 hours).
| INTELLIGENT DEFROST
The appliance will defrost automatically when the coil sensor detects that the
internal temperature is too low. During defrosting the indicator will light
up. Once the defrost cycle has finished, the appliance will return to the mode
that was previously operating.
| TANK-FULL
When the water tank is full, the TANK FULL indicator light will flash, and the
unit will stop operating. Once emptied and replaced, the appliance will resume
operation.
|
OPTIONAL CARBON FILTER (Air purification function)
Remove the carbon filter from the bag and insert it on the filter housing. It
is suggested to hoover the carbon filter every 2-3 weeks and change it every
3-6 months as this will help to ensure the room is kept fresh and odor-free.
HUMIDITY LEVEL & TIMER 2 DIGIT DISPLAY
The led indicator performs the following functions:
- When the unit is plugged in, it will indicate the humidity level of the room.
- When the UP and DOWN buttons are pressed, it will indicate the desired humidity currently set.
- When the timer is programmed will show the duration.
Notes : When the humidity level is outside the normal operational parameters will show LO/HI. If ambient humidity is lower than 20%, it will show “LO” If the ambient humidity is higher than 90%, it will show “HI”
QUICK REFERENCE GUIDE
Power Button: Press to turn the dehumidifier on and off.
Timer: Press the timer button, then use the buttons to adjust the duration of the timer (1-24 hrs, start/ stop timer).
If set while the unit is running: The number will represent the number of hours the unit will operate before turning off. This will not be affected if the unit enters defrost mode or the tank is emptied and reinserted.
If set while the unit is in standby: the set number represents the period in hours after which the unit will start. To cancel start/stop mode press the timer key again.
Up and Down Buttons: During the High or Low modes when
the unit is displaying the current relative humidity, these buttons can be
used to adjust the desired humidity level.
The desired relative humidity can be set between 35 and 80% in 5% increments.
SMART Mode: This is designed for maximum convenience and maintains the
ideal domestic environment humidity level of 50-55% while saving electricity.
This is the default mode and is recommended for most users.
During operation, the compressor will operate until the desired humidity is
reached and then will stop. The fan moves the air around the room ensuring the
entire air in the room is processed and humidity correctly measured.
To achieve drier air, or while drying laundry use the DOWN button to select a
lower desired humidity (e.g. 3545%).
LAUNDRY MODE: When drying clothes it is advised for the dehumidifier to operate continuously with maximum water extraction until the water tank is full. Set the unit to the Smart mode, and set the desired humidity level between 35%-50%. 35% is very dry and is hardly achievable in a UK domestic environment. As such the unit will work until the water tank is full when set to 35%. Do not place clothes directly over any of the vents on the dehumidifier. Make sure that there is nothing blocking the hot air exhaust airflow and for best results place the laundry within 1.5 meters of the dehumidifier.
NOTES:
- If a permanent drainage pipe is fitted the unit will not stop operating. Setting the desired humidity to around 35% is good for laundry mode, a quick-drying boost, or in emergencies. It is not recommended for long normal operation in a domestic or office environment.
- To allow more moisture in the air, press the up button and set to a higher desired humidity (e.g. 60-70%).
- We recommend setting the Humidity to 50-55%. This is great for domestic operation and dry storage
- Setting the humidity to 60% is great for personal comfort and applications where 50% RH is considered too dry
- Setting the humidity to 70% is ideal for unoccupied properties or where an economical run is needed without the need to reduce the humidity further.
OTHER FEATURES AND INDICATORS
TANK FULL LIGHT
When the water tank is full, removed or incorrectly inserted the unit will
stop dehumidifying, the red tank full light will illuminate and the unit will
beep. Empty the tank and reinsert it correctly to resume operation.
AUTO DEFROST
When the frost builds up on the evaporator coils, the compressor will cycle
off and the unit will go into defrost mode.
Following completion of the defrost mode, the unit will return to the previous
operating settings.
- When the unit is running in a room with a temperature between 5 C, it will enter defrost mode roughly every 30 minutes.
- When the unit is running in a room with a temperature between 12⁰C and 20⁰C, it will enter the defrost mode roughly every 45 minutes.
HUMIDISTAT CONTROL AND FAN/COMPRESSOR OPERATION
- When the humidity of the room is 2% lower than the desired humidity the compressor will turn off automatically but the fan will continue to operate to ensure that the air within the room is not stale. The unit will use only a minimal amount of energy in fan mode.
- When the humidity of the room is equal to or higher than the desired humidity the compressor will restart after a 3 minutes delay to protect the compressor.
AUTO-RESTART (on some models)
If the unit stops unexpectedly due to the power cut, it will restart with the
previous function selected automatically when the power resumes, and the
3-minute compressor protection has elapsed.
POWER
After the unit has stopped, to protect the compressor it is not recommended to
resume operation for at least 10 minutes. The operation can resume after this
period lapses. When the unit is restarted there is a 3 minutes delay before
the compressor will start.
LIGHTWEIGHT PORTABLE DESIGN ON CASTORS
The dehumidifier is built to be compact and lightweight. The castors on the
bottom of the unit make it easy to move from room to room.
Your dehumidifier contains an advanced micro-CPU-controlled device that is
capable of self-diagnostics. The LCD display may also show the error and
protection codes.
POSITIONING THE DEHUMIDIFIER
A badly positioned dehumidifier will have little effect. In positioning the
dehumidifier please ensure circulation of air in not restricted around the
unit.
Allow at least 20 cm of space around the unit. This dehumidifier is designed
only for indoor residential or small office applications and any commercial or
industrial use will invalidate the warranty.
Use in an enclosed area for maximum efficiency. Close all doors, windows to
create an effective operating environment. Do not use outdoors.
Your electriQ dehumidifier will begin to protect your space from the harmful effects of excessive moisture as soon as it is turned on. Excess moisture is dispersed throughout your home. For this reason, the dehumidifier should be positioned in a central and clear location so that it can draw this moist air towards it from all over the home. A warm hallway or landing is an excellent position for your dehumidifier. If possible, leave interior doors ajar to allow air circulation.
Alternatively, if you have a serious problem in one area you can begin by
positioning the dehumidifier there and moving it to a more central location at
a later date. For the most effective use, run your dehumidifier with external
doors and windows kept closed. Please note the unit should not be placed
directly against a radiator or other heat source.
Before moving the appliance the water tank should be emptied. The handle on
the appliance is designed to aid n its movement and should not be used to
support the full weight of the dehumidifier. When carrying the unit, it should
be kept upright and sufficiently supported from its base. The handle should
not be used if there is any signs of damage to its fixings.
When positioning your electriQ dehumidifier, ensure that it is placed clear of
any obstacle that may limit the air movement. Place the dehumidifier on a flat
dry surface.
Note: Do not force castors to move over the carpet or uneven surfaces, nor
move the unit with water in the tank as may tip over and spill water.
WATER DRAINAGE
When the water tank is full, the unit will stop automatically. When this happens the TANK FULL red light will show on the control panel.
NOTE: Only empty the water tank when it is full or before moving or
storing the unit.
There are two ways to dispense collected water.
-
USE THE TANK
When the tank is full, the unit will automatically stop running, and the Tank Fullindicator will flash. Slowly pull out the tank. Grip the tank by its handle securely, and carefully pull it out. Empty the water tank and reinsert it into the dehumidifier. The tank must be in place and securely seated for the dehumidifier to operate again. The dehumidifier will re-start when the tank is restored in its correct position.
NOTES:
When you remove the water tank, do not touch sensors or any parts which are situated behind tank. Doing so may damage the product. Be sure to push the tank gently all the way into the unit. Banging the bucket against anything or failing to push it in securely into place may cause the unit not to operate. Do not remove any parts from the water tank or tank enclosure. The water full sensor will no longer be able to detect the water level correctly and water may leak from the water tank. -
CONTINUOUS DRAINAGE
Water can be automatically plumbed in or drained into a sink, a larger recipient or through the wall into an outside drain by attaching a pipe to the unit (10 mm internal diameter) (not included). Insert the pipe into the drain outlet at the back of the unit as shown here.
Make sure the connection between pipe and the drain outlet is tight and does not leak. Then direct the pipe to a suitable drainage point. This unit uses gravity to dispose of water hence the drain should be lower than the water outlet on the unit. Put the tank back. Be sure to run the water pipe downward and let the water to flow out smoothly. Do not kink or bend the pipe.
The permanent drain can be used in conjunction with a water pump (e.g. when draining from a cellar) to lift the water upwards.
CARE AND MAINTENANCE
Always shut off the unit and unplug from the mains before cleaning or performing any maintenance. When it is not in use for long periods it is advisable to remove the plug from the power socket. Do not use chemical solvents (such as benzene, alcohol or gasoline) as they may cause irreversible damage to the unit.
- CLEAN THE GRILLE AND CASE
Use water and a mild detergent to clean the washable mesh filters. Do not use bleach or abrasives. Do not splash water directly onto the main unit. Doing so may cause an electrical shock and can lead to the insulation deteriorating, or cause the unit to rust. The air intake and outlet grilles get soiled easily, so use a vacuum attachment or soft brush to clean. Wipe the dehumidifier body with a soft damp cloth or kitchen towel.
Remove the ABS filter frame. If the optional carbon filters are fitted, remove
them from the frame and hoover gently approximately every 2-3 weeks. If the
mesh filter is dirty hoover it, if it is heavily soiled wash it with warm
soapy water and dry thoroughly before reinserting it in the unit.
When filter cleaning is finished and filters are dry placed them back into the
unit.
NOTE: While the carbon filter is optional never run the unit without the mesh filter frame correctly inserted.
- CLEAN THE WATER TANK
Every few weeks, clean the tank to prevent the growth of mould, mildew and bacteria. Partially fill the tank with clean water and add a little mild detergent. Swish it around and than empty the tank and rinse.
NOTE: Do not use a dishwasher to clean the tank. After cleaning and drying, the tank must be reinserted securely into a dehumidifier in order to restart operation.
END OF SEASON MAINTENANCE
- Empty and clean the water tank.
- Clean the unit and the filters as per cleaning procedure above.
- Coil the power cord on the special cord storage rest at the back of the unit.
- Cover the unit and keep it in a dry place.
FREQUENTLY ASKED QUESTIONS
Why doesn’t the dehumidifier seem to extract much water if the temperature
is low?
This is a compressor dehumidifier that works best in temperatures above 15⁰C.
If the temperature is low and the air is dryer than the setting on the
humidistat the unit will not extract water. If you want to use a dehumidifier
for outside buildings, unheated properties, boats or garages please check our
desiccant range.
Why doesn’t the unit work /or stops suddenly?
The water tank may be full or displaced. To rectify: empty the tank and
carefully place the tank back in the unit. Also the unit may be running in
dehumidifying mode with a low room temperature. Please check if the room
temperature is lower than 5⁰C. If so, the unit will stop working while in
dehumidifying mode. (unit may be defrosting).
The ambient operating range is between 5⁰C and 35⁰C with a relative humidity
ranging from 30% to 80%. For maximum efficiency use the unit between 15⁰C and
32⁰C.
Sometimes cold and/or hot air comes out from the air outlet grill, why?
When the unit is in the dehumidifying mode it absorbs humid air from room and
freezes it to reduce the humidity.
During the cold cycle there should be cold air coming out of the unit
During the hot cycle hot dry air should be coming out of the outlet grill.
TROUBLESHOOTING
Issue | Cause | Solution |
---|---|---|
Hot or cold air being produced | Normal Operation | When the unit is in the |
dehumidifying mode it absorbs humid air from the room and freezes it to reduce
the humidity.
During the cold cycle, there should be cold air coming out of the unit During
the defrost cycle hot dry air should be corning out of the outlet grill.
Unit does not operate| Is the plug properly inserted in the socket?| Insert
the plug into the socket and turn the switch on.
Does the tank full indicator is red?| Tank full. float displaced or tank not
properly inserted. Empty tank, check float, and make sure tank is properly
inserted in the unit.
Front louvers do not open| Louvre motor is blocked| Check if anything is
blocking the louver
Try to move gently the louvres up and down while the unit if off If the above
fails return the unit to the service center.
Dehumidifier does not extract water| Is the unit set to a humidity level lower
than the one in the room?| Set the humidity level on the humidistat below the
current humidity reading.
Is the temperature too low for water extraction to be efficient?| Increase the
temperature in the room or reposition the unit.
Is any intake grill or discharge blocked? Is the unit too close to walls?|
Remove obstructions and restart the unit.
Ensure a distance of at least 20 [cm between the unit & walls
Airflow seems weak| Is the filter dirty or clogged?| Please service the
filters regularly as per the user manual.
Unit is noisy during operation| Is the unit on an uneven surface?| Please
place it on a flat horizontal surface.
Is filter dogged?| Please service the filters regularly as per the user
manual.
E3 or E4| Humidity sensor error| Use the unit within the prescribed humidity
range. Unplug the unit. rest and plug it back in. If the error repeats. call
for the service center.
El or E2| Temperature sensor error| Use the unit within the prescribed
temperature range. Unplug the unit, rest, and plug it back in. If the error
repeats. call for the service center.
E5 or E6| Abnormal Coil sensor temperature or current| Use the unit within the
prescribed humidity and temperature range. Unplug the unit. rest and plug it
back in. If the error repeats. call for the service center.
Defrost light on and unit
stops regularly
| Unit is defrosting| Allow the unit to automatically defrost. The protection
will dear after the unit self defrosts. Increase the temperature in the room
if this repeats too often
Tank full red light| Water tank full notification| Tank is full or is not in
the right position— Empty the tank and replace it in the right position.
Any other malfunctions will need to be reported to electriO service center. Do
not attempt unauthorized repairs as these may invalidate the warranty.
TECHNICAL DATA
Model | CD12P |
---|---|
Voltage | 220-240V-50Hz |
Dehumidifying capacity | 12 L / day (at 30° C / 80%RH) |
Fan Speeds | 1 |
Power Consumption | 185W |
Running Amps | 0.81 Amps |
Tank Capacity | 2.5 litres |
Desired Humidity Range | 35 – 80% |
IP Rating | IPX1 |
Refrigerant | R290, 55 grams |
Airflow m3/h | 135 |
High / Low Pressure | 3.2/0.7MPa |
Filters | Carbon (Optional) HEPA (Optional) |
Dimensions mm (WxDxH) | 349x491x200 |
Weight kgs | 10.5 |
GWP | 3 |
Disposal: Do not dispose of this product as unsorted waste. Collection of
such waste must be handled separately as special treatment is necessary.
Recycling facilities are now available for all customers at which you can
deposit your old electrical products. Customers will be able to take any old
electrical equipment to participate sites run by their local councils. Please
remember that this equipment will be further handled during the recycling
process, so please be considerate when depositing your equipment. Please
contact the local council for details of your local household waste recycling
centers.
Please, for your own convenience, make these simple checks before calling the service line.
- Has the unit been standing upright for at least 2 hours?
- Is the unit plugged into the mains?
- Is the fuse OK?
- Switch the unit off and wait three minutes to see if the issue is resolved. Restart the unit.
- Check if the water tank is full.
- Was the troubleshooting guide followed?
If the unit still fails to operate call: 0330 390 3061 or complete the online
form Office hours: 9 AM – 5 PM Monday to Friday
Unit J6, Lowfields Business Park,
Lowfields Way, Elland
West Yorkshire, HX5 9DA
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>