electriQ EAP300HUVC User Manual
- June 7, 2024
- ElectriQ
Table of Contents
USER MANUAL
EAP300HUVC
Thank you for choosing electriQ
Please read this user manual before using this innovative
Air Purifier and keep it safe for future reference.
Visit our page www.electriQ.co.uk for our entire
range of Intelligent Electricals
SAFETY INSTRUCTIONS
Important!
- Carefully read the instructions before operating the unit.
- This appliance is for indoor use only.
- This unit must only be connected to a 220-240V / 50Hz earthed outlet.
- Installation must be in accordance with the regulations of the country where the unit is used.
- If you are in any doubt about the suitability of your electrical supply, have it checked and, if necessary, modified by a qualified electrician.
- This air purifier has been tested and is safe to use. However, as with any electrical appliance – use it with care.
- Disconnect the air purifier from the socket when changing the filters or cleaning the unit.
- Avoid touching any moving parts within the appliance.
- Never insert fingers, pencils, or any other objects through the guard.
- This device is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities. It is also not intended for use by those with a lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
- Do not leave children unsupervised with this device.
- Do not clean the unit by spraying it or immersing it in water. Use a damp cloth only. Never allow water or vapors to enter the unit.
- Do not clean with strong chemical agents or other abrasive materials.
- Never connect the unit to an electrical outlet using an extension cord. If a power outlet is not available, one should be installed by a qualified electrician.
- Never operate this appliance if the cord or power supply is damaged. Ensure the power cord is not stretched or exposed to sharp objects/edges.
- A damaged power supply should be replaced by the manufacturer. Never extend or attempt to change the power supply lead.
- Any service other than a regular cleaning or filter replacement should be performed by an authorized service representative. Failure to comply could result in avoided warranty.
- Do not use the appliance for any purpose other than its intended use.
- Avoid removing the power cord from the socket whilst the unit is still in operation. This could cause electrical damage.
- Never use the power supply as a switch to start and turn off the air purifier. Use the provided ON/OFF button located on the control panel.
- Always place the unit on a dry and stable surface.
- The use of accessory attachments that have not been approved by the appliance manufacturer is not recommended, as this may result in fire, cause an electric shock, and/or cause personal injury.
- Ensure hands are fully dried before plugging or unplugging the appliance.
- The appliance should not be installed in the laundry or wet rooms.
Energy Saving and Unit Safety Protection Tips
- Do not cover or restrict the airflow from the outlet or inlet grills.
- For maximum performance and safety, the minimum distance from a wall or objects should be 20cm. Keep away from other electrical appliances.
- Keep the filters clean. Under normal conditions, filters should only need cleaning once every two weeks (approximately). Since the filters remove
airborne particles, more frequent cleaning may be necessary, depending on the air quality.
AIR PURIFIER DIAGRAM
ABOUT YOUR AIR PURIFIER
The EAP300HUVC provides multiple stages of air purification using professional air filtration and intelligent sterilization technologies. This unit features an advanced all-in-one photocatalytic HEPA and an activated carbon filter for improved air filtration.
- A primary filter, made of non-woven materials, is used for removing large particles like hair and dust.
- The elementary filter removes large particles like dust and hair.
- Antibacterial HEPA filter to remove 99.9% of airborne particles of 0.25 micrometers or larger.
- An activated carbon filter removes unpleasant odors and absorbs harmful substances such as formaldehyde and benzenes.
- The molecular sieve absorption layer removes smaller particles
- The photocatalytic filter is a titanium dioxide layer that promotes the chemical reactions for UV to kill bacteria.
- UV filtration kills bacteria
- Plasma Ioniser sterilizes the air further and removes mold spores and allergens from the air The EAP300HUVC also features an air quality LED indicator that will provide a visual indication of the current air quality.
Applications:
- Personal use in domestic and office space to improve air quality
- Helps smokers to reduce contaminants within the air
- Can help improve the symptoms of asthma and pollen allergies?
- Great for children’s rooms and small offices
NOTE: This air purifier is not a substitute for proper ventilation, regular vacuum cleaning, or for use in place of a cooker hood whilst cooking. If the relative humidity is above 60% we recommend using a dehumidifier to reduce the humidity.
INFORMATION ON INDOOR POLLUTANTS
VOC (Volatile Organic Compound): VOCs come from motor vehicle exhausts,
gasoline vapor, pollutants such as formaldehyde, ammonia and many other common
and chemical solvents such as paints and glues, or can be a by-product of mold
growth. VOCs cause irritation to the eyes and or nose as well as causing
headaches, nausea, and even potential damage to the central nervous system.
Pressed wood furniture, newly decorated rooms, paint, and cleaning solvents
are common sources of VOCs.
Mold / Fungus: These can affect our respiratory system and cause allergic
reactions, like a runny nose, eye and throat irritation, headaches, fatigue,
and aggravation of asthma. Other indoor pollutants include bacteria, viruses,
dust mites, and pollen.
Emissions from electronic office equipment: Many studies, including those
from EPA and the University of California Berkley, have reported that
emissions from office equipment such as computers and printers, include VOCs,
ultra-fine particles, and ozone. These emissions have been proven to have a
negative effect on the health of many people which can be reduced by using an
air purifier.
Using HEPA filters, Activated Carbon filters, and Plasma Ionisation: An
effective HEPA filter is absolutely necessary to remove particles, even at a
microscopic level; it ensures that the particles are not spread. Plasma
Ionisers will sterilize the air and reduce bacterial growth. The antibacterial
activated carbon on the EAP300HUVC is a natural material biosynthesized from
the walnut shell, the absorption area of activated carbon is very large at up
to 300,000 square meters. The activated carbon filter will absorb unpleasant
odors and reduce the VOC content in the air. The Plasma Ioniser will sterilize
the air and reduce bacterial growth.
OPERATION INSTRUCTIONS
BEFORE FIRST USE:
HOW TO USE:
ON/OFF | Press to turn the appliance on and off. |
---|---|
AUTO | Change the appliance into Auto mode. The fan speed will be automatically |
determined by the air quality. When activated the Auto symbol on the display
will illuminate.
SPEED| Press to change between the three fan speeds. The appropriate symbol
will illuminate on the display to indicate the currently selected fan speed.
SLEEP| Press to enter sleep mode. The fan will be changed to its lowest
setting and the lights on the unit will turn off.
TIMER| With the unit turned on, repeatedly press the timer button to select
how many hours it should turn off. The duration can be set to 1, 2, 4, or 8
hours.
FUNCTION| Press to activate the ionizer and/or UV functions. The currently
active functions will she showed by the symbols illuminated on the display.
RESET INDICATOR| When illuminated this indicates the filters require changing.
Replace the filters and press the sleep button for 5 seconds to extinguish the
light.
AIR QUALITY: The air quality indicator will illuminate to show the current air
quality.| INDICATOR COLOUR| AIR QUALITY
---|---|---
Blue| Good
Purple| Medium
Red| Bad
REMOTE CONTROL
Your air Purifier is also provided with a remote control to allow convenient operation. The remote provides access to all the same controls as the control panel.
ON/OFF | Press to turn the appliance on and off. |
---|---|
AUTO | Change the appliance into Auto mode. The fan speed will be automatically |
determined by the air quality.
SPEED| Press to change between the three fan speeds.
SLEEP| Press to enter sleep mode. The fan will be changed to its lowest
setting and the lights on the unit will turn off.
TIMER| With the unit turned on, repeatedly press the timer button to select
how many hours it should turn off. The duration can be set to 1, 2, 4, or 8
hours.
FUNCTION| Press to activate the ionizer and/or UV functions.
REPLACING THE BATTERIES
The remote control is powered by a Lithium Button Cell Battery (CR2025). Should the remote become unresponsive, replace the battery following the instructions below:
- Turn over the remote and press the battery cover, while sliding off the rear of the remote.
- Replace the battery with the same type, ensuring it is placed with the positive side facing outwards.
- Refit the battery cover.
CARE AND MAINTENANCE
- Always shut off the unit and unplug from the mains before cleaning or performing any maintenance.
- When the unit is not in use for long periods, it is advisable to remove the plug from the power socket.
- Do not use chemical solvents (such as benzene, alcohol, or gasoline) as they may cause irreversible damage to the unit.
CHANGING THE FILTER
Open the filter cover by pressing in the retaining tabs and pulling the front cover free. Remove the old filter by simply pulling on the tabs to release them. Replace the filter with a new/clean one before replacing the filter cover. Press and hold the Sleep button for 5 seconds to reset the filter usage monitor once it has been replaced.
CLEANING THE CASE
- Only use tepid water and a mild detergent on a soft cloth.
- Do not use bleach or abrasives.
- Do not splash water directly onto the main unit.
- Avoid wetting the power connection port, doing so may cause an electric shock and can lead to the insulation deteriorating or unit rusting.
CLEANING THE FILTERS AND FILTER HOLDING AREA
- Hoover the filter gently every 2-3 weeks or more often if used in dusty environments.
- Ensure the filter is not damaged during the cleaning process and replace if it shows signs of damage.
- Wipe the filter holding area with a dry cloth if necessary.
CLEANING THE FILTER COVER AND CLEAN AIR OUTLET
- Use water and a mild detergent.
- Do not use bleach or abrasives.
- Do not spray water inside the unit.
- If the clean air outlet grilles get soiled easily, use a vacuum attachment or soft brush to clean.
- If the filter cover is dirty, hoover it. If it is heavily soiled, wash it with warm soapy water and dry thoroughly before reinserting it in the unit.
NOTE: Do no assemble the unit and power it on before all the parts are completely dry. Any other maintenance other than what is described in this user manual must be only performed by the service center.
TECHNICAL SPECIFICATION
Input power | 220-240— 50/60Hz |
---|---|
Power consumption | 45W |
Weight | 6.2Kg |
Dimensions | 348 x 190 x 556mm |
Fan speeds | Low / Medium / High |
Noise | 561dB |
Ions | 10 million / cm3 |
Formaldehyde purification rate | 96.2% |
Germ purification rate | 97.6% |
DISPOSAL
Disposal: Do not dispose of this product as unsorted waste. Collection of such waste must be handled separately as special treatment is necessary.
Recycling facilities are now available for all customers at which you can deposit your old electrical products. Customers will be able to take any old electrical equipment to participate in sites run by their local councils. Please remember that this equipment will be further handled during the recycling process, so please be considerate when depositing your equipment. Please contact the local council for details of your local household waste recycling centers.
TROUBLESHOOTING
ISSUE | CHECK |
---|---|
Not working | Check that the power adapter is connected and is the correct |
rating.
Ensure the front panel is correctly fitted and that the peg on the rear of the
panel is undamaged.
Abnormal Smells| Check if the filter is clean. Replace the filter.
Pollutants not removed and loud noise when running| Check if the filter is
clean. Replace the filter
Air quality indicator remaining red.| Clean the sensor
Reset indicator illuminated.| Replace the filter and reset the appliance
following the care and maintenance section.
electriQ UK SUPPORT
www.electriQ.co.uk/support
Please, for your own convenience, check the troubleshooting guide before
calling
the service line.
If the unit still fails to operate call: 0330 390 3061 or complete the online
form
Office hours: 9 AM – 5 PM Monday to Friday
www.electriQ.co.uk
Unit J6, Lowfields Way
Elland, West Yorkshire
HX5 9DA
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>