My Big Green Complete® Deep Cleaner & Vacuum is not spraying | Support

June 7, 2024
Bissell

  • Empty dirty water tank

    • Fill solution tank with water

    • Plug machine into a working outlet

    • Disconnect wand from grip trigger handle

    • Turn machine on & press trigger

    • Check for spray at the small spray tip where the water comes out

    • If there is spray

      • Clean out spray tip on tool using a paper clip
      • Wand pieces and tool needs to be pressed firmly together
    • If not spraying:

    • Remove solution tank

      • Verify the red gasket is correctly attached to the cap on the bottom of the tank
      • The red auto-load gasket should face outward, screen should be inside, not outside
      • If missing, it should be replaced
    • While holding tank over sink (cap side down) push up on the X-valve

      • Water should flow out
      • If not, cap & insert should be replaced
    • Return tank to machine

    • Remove hose solution line

    • There should be 2 small O-rings on the fitted end of the hose solution line

      • If missing, the hose should be replaced
    • Reinsert hose solution line

    • After inserting, twist to right to lock

    • Run the machine for 5 minutes, with all 3 buttons engaged

      • This should dislodge any clogs

If all steps above have been followed and still no spray, visit a BISSELL Authorized Service Center or Contact Us