My Big Green Complete® Deep Cleaner & Vacuum is not spraying | Support
- June 7, 2024
- Bissell
Table of Contents
-
Empty dirty water tank
-
Fill solution tank with water
-
Plug machine into a working outlet
-
Disconnect wand from grip trigger handle
-
Turn machine on & press trigger
-
Check for spray at the small spray tip where the water comes out
-
If there is spray
- Clean out spray tip on tool using a paper clip
- Wand pieces and tool needs to be pressed firmly together
-
If not spraying:
-
Remove solution tank
- Verify the red gasket is correctly attached to the cap on the bottom of the tank
- The red auto-load gasket should face outward, screen should be inside, not outside
- If missing, it should be replaced
-
While holding tank over sink (cap side down) push up on the X-valve
- Water should flow out
- If not, cap & insert should be replaced
-
Return tank to machine
-
Remove hose solution line
-
There should be 2 small O-rings on the fitted end of the hose solution line
- If missing, the hose should be replaced
-
Reinsert hose solution line
-
After inserting, twist to right to lock
-
Run the machine for 5 minutes, with all 3 buttons engaged
- This should dislodge any clogs
-
If all steps above have been followed and still no spray, visit a BISSELL Authorized Service Center or Contact Us