My PROdry® Upright Carpet Cleaner brush is not turning | Support

June 7, 2024
Bissell

The brush does not spin manually, and the brush will turn in the upright and reclined positions

  • Unplug machine

  • Take off both tanks, recline handle to floor, and roll machine over

  • Remove the brush to check the belt

    • Take out the 6 screws from the sole plate
    • Lift off the belt cover (on the non-cord side)
    • Slide the brush out
    • Replace brush if needed
    • Replace belt if needed
  • The Overcurrent Protector may have been tripped

    • Turn the machine off and wait at least 15 seconds
    • The protector should reset, allowing cleaning to continue
  • Recipient Email

Your Email

Your Name

Was this answer helpful?

Yes
No

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Bissell User Manuals

Related Manuals