Bard Multi-Tec Wall Mount Air Conditioner User Manual
- June 7, 2024
- Bard
Table of Contents
REPLACEMENT PARTS MANUAL
MULTI-TEC ® Wall-Mount
Air Conditioner
Models:
W30LBPA,W30LBPB, W30LBPC, W30LBPF, W36LBPA, W36LBPB, W36LBPC, W36LBPF
Bard Manufacturing Company, Inc.
Bryan, Ohio 43506
Manual: 2110-1459C
Supersedes: 2110-1459B
Date: 4-19-21
www.bardhvac.com
CABINET COMPONENTS
Dwg No.| Part Number| Description| W30LBPA, B| W30LBPC| W30LBPF| W36LBPA, B|
W36LBPC| W36LBPF
---|---|---|---|---|---|---|---|---
1
1
1| 113-149- 1
113-360 2
113-149-4 3| Top Rain Flashing
Top Rain Flashing
Top Rain Flashing| X
X
X| X
X
X| X
X
X| X
X
X| X
X
X| X
X
X
2
2
2| S507-308- 2
S507-319 2
S507-320 3| Top
Top
Top| X
X
X| X
X
X| X
X
X| X
X
X| X
X
X| X
X
X
3
3| S123-130
S123-143 23| Drain Pan
Drain Pan| X
X| X
X| X
X| X
X| X
X| X
X
4
4
4| S509-451
S509-455 2
S509-453 3| Upper Back
Upper Back
Upper Back| X
X
X| X
X
X| X
X
X| X
X
X| X
X
X| X
X
X
5| 105-1302| Grommet Retainer| X| X| X| X| X| X
6
6
6| S501-935- 1
S501-998 2
S501-943 3| Right Side
Right Side
Right Side| X
X
X| X
X
X| X
X
X| X
X
X| X
X
X| X
X
X
7
7
7| S543-175- 1
S543-185 2
S543-184 3| Right Side Cover Plate (Outer)
Right Side Cover Plate (Outer)
Right Side Cover Plate (Outer)| X
X
X| X
X
X| X
X
X| X
X
X| X
X
X| X
X
X
8| 113Y480| Filter Bracket| 2| 2| 2| 2| 2| 2
9| 137-259| Fill Plate| X| X| X| X| X| X
10
10| S132-104
S132-172| Control Panel Cover (Inner)
Control Panel Cover (Inner)| X| X| X| X| X| X
11| 113-140| Bottom Mounting Bracket| X| X| X| X| X| X
12
12
12| S153-218 1
S153-405 2
S153-387 3| Disconnect Access Door
Disconnect Access Door
Disconnect Access Door| X
X
X| X
X
X| X
X
X| X
X
X| X
X
X| X
X
X
13
13
13| S533-228 1
S533-235 2
S533-236 3| Control Panel Cover (Outer)
Control Panel Cover (Outer)
Control Panel Cover (Outer)| X
X
X| X
X
X| X
X
X| X
X
X| X
X
X| X
X
X
14
14
14| 118-124- 1
118-140 2
118-139 3| Side Grille
Side Grille
Side Grille| 2
2
2| 2
2
2| 2
2
2| 2
2
2| 2
2
2| 2
2
2
15| Control Panel Assembly| See Control Panel Assy. Drawing & Parts List
Assy.| X| X| X| X| X| X
17
17| S536-498
S536-877 2| Cond. Partition Block Off Plate
Cond. Partition Block Off Plate| X
X| X
X| X
X| X
X| X
X| X
X
18
18| S127-472
S127-533 2| Lower Base
Lower Base| X
X| X
X| X
X| X
X| X
X| X
X
19
19| 125-081
125-083 2| Fan Shroud
Fan Shroud| X
X| X
X| X
X| X
X| X
X| X
X
20
20| S521Y527
S521-561 2| Condenser Partition
Condenser Partition| X
X| X
X| X
X| X
X| X
X| X
X
22
22
22| 118-104- 1
118-109 2
118-114 3| Condenser Grille
Condenser Grille
Condenser Grille| X
X
X| X
X
X| X
X
X| X
X
X| X
X
X| X
X
X
23
23
23| S553-523- 1
S553-549 2
S553-550 3| Vent Option Door
Vent Option Door
Vent Option Door| X
X
X| X
X
X| X
X
X| X
X
X| X
X
X| X
X
X
24
24
24| S553-524- 1
S553-553 2
S553-554 3| Filter Door
Filter Door
Filter Door| X
X
X| X
X
X| X
X
X| X
X
X| X
X
X| X
X
X
25
25
25| S514-241- 1
S514-238 2
S514-239 3| Upper Front
Upper Front
Upper Front| X
X
X| X
X
X| X
X
X| X
X
X| X
X
X| X
X
X
26| 121Y467| Blower Partition| | | | | |
27| 105Y850| Side Support| | | | | |
28| 137-685| Bottom Evaporator Fill| | | | | |
29
29
29| S501-936-* 1
S501-999 2
S501-946 3| Left Side
Left Side
Left Side| X
X
X| X
X
X| X
X
X| X
X
X| X
X
X| X
X
X
30| 147-044| Evaporator Support| X| X| X| X| X| X
31| S111Y030| Outlet Air Frame Assembly| X| X| X| X| X| X
32| 135Y123| Heat Shield| X| X| X| X| X| X
33
33
33| 109-450
109-454 2
109-452 3| Lower Back
Lower Back
Lower Back| X
X
X| X
X
X| X
X
X| X
X
X| X
X
X| X
X
X
NS| 135-329| Air Baffle| X| X| X| X| X| X
NS| BOP-3| Blank Off Plate| X| X| X| X| X| X
NS| 5252-033| Bard Nameplate| X| X| X| X| X| X
- Exterior cabinet parts are manufactured with various paint color options. To ensure the proper paint color is received, include the complete model and a serial number of the unit for which cabinet parts are being ordered.
- Exterior cabinet parts are manufactured from stainless steel Code “S”
- Exterior cabinet parts are manufactured from aluminum Code “A”
FUNCTIONAL COMPONENTS
SEXP-945
FUNCTIONAL COMPONENTS
NS – Not Shown
- – Used with stainless steel cabinet option
- – Optional on these models
CONTROL PANEL
SEXP-883 A
- Replacement part will have a letter attached to the end of the part number to designate software version (Example: 8301-068-001A). A software upgrade of all PLCs onsite (units and controllers) should accompany any PLC replacement. Latest revisions of software, changelog and instructions are available on the Bard website at http://www.bardhvac.com/software-download/
Circuit breakers listed are for units without electric heat, “0Z” models. Hot gas bypass models not available without electric heat. See heater replacement parts manual for units with electric heat.
NS = Not Shown
BLOWER ASSEMBLY
FREE COOLING COMPONENTS
FREE COOLING AIR HOOD
- Exterior cabinet parts are manufactured with various paint color options. To ensure the proper paint color is received, reference the following codes: Beige -X Buckeye Gray -4 White -1
- Exterior cabinet parts are manufactured from stainless steel Code “S”
- Exterior cabinet parts are manufactured from aluminum Code “A”
FREE COOLING DAMPER MOTOR
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>