DeLonghi EL 112 Air Conditioner User Guide

June 7, 2024
Delonghi

DeLonghi logo

DeLonghi EL 112 Air Conditioner-i

De’Longhi Appliances via Seitz, 47 31100 Treviso Italia www.delonghi.com
5715113701_00_1219

DeLonghi EL 112 Air Conditioner -

LOCAL AIR CONDITIONER

DeLonghi EL 112 Air Conditioner-1DeLonghi EL
112 Air Conditioner-2DeLonghi EL 112 Air
Conditioner-3

DeLonghi EL 112 Air Conditioner-4

DeLonghi EL 112 Air Conditioner-5

INTRODUCTION

Thank you for choosing a De’Longhi product. Please take a few moments to read the instructions to avoid risks or damage to the appliance.

DESCRIPTION

Description of the appliance (see page 2 – A)

A1 air outlet flap
A2 control panel
A3 handles
A4 castors
A5 BioSilver filter
A6 air intake grille
A7 air exhaust hose housing
A8 air intake grille
A9 power cable
A10 drainage hose with cap
A11 CST remote control compartment
Descrizione of the accessories (see page 2 – B)
B1 wall flange with cap
B2 air exhaust hose
B3 hose adaptor
B4 adapter for window bracket
B5 window bracket with wing nut
B6 adapter for wall mounting/window outlet
B7 window outlet
B8 CST (Cool Surround Technology) remote control
B9 window bracket cap

ELECTRICAL CONNECTION

Before plugging into the mains, check the following:

  • the mains voltage is the same as that indicated on the plate on the back of the appliance;
  • the socket and electrical line are sized to support the load required;
  • the socket is the proper type for the plug, otherwise, replace the socket;
  • the socket is connected to an efficient earthing system. the manufacturer is not responsible in the event of non-compliance with these injury prevention standards.
  • The power cable must only be replaced by specialized technicians.

USE
The instructions below will enable you to prepare your air conditioner for operation as efficiently as possible. Before use, make sure the air intake and outlet  rilles
are unobstructed.
Please note: This appliance is provided with an auto-evaporation feature for condensate removal during cooling and dehumidifying modes.

AIR CONDITIONING WITHOUT INSTALLATION CASEMENT WINDOW
If you have a casement window proceed as follows:

  • Fit the air exhaust hose (B2) in the relevant housing located on the rear side of the appliance (fig. 1).
  •  Screw the window outlet (B7) and place it outside the window to exhaust the hot air (fig. 2).

DOUBLE-HUNG WINDOW

If you have a double-hung window proceed as follows:

  • Insert and lock the adapter for window bracket (B4) into the slot of the window bracket (B5) (fig.3)
  • Place the window bracket in the window sill, and extend the bracket fully within the window frame (fig. 4).
  •  Fix the bracket by the wing nut (fig. 5) (Should the window bracket be too large for the window the plastic can be cut with a saw by a qualified professional).
  • Insert the air exhaust hose (B2) into the accessory for the win- dow bracket (B4) (fig. 6 ) and rotate it as shown in fig. 3.
  • In order to facilitate the fitting of the air exhaust hose (B2) in the relevant housing located on the rear side of the appliance, position the hose adapter‘s tabs (B3) in a horizontal axis as shown in fig. 7 and proceed as shown in fig.1.

SLIDING WINDOWS

  •  thanks to the locking wing nut, it’s possible to use the window bracket also for sliding windows. Position the hole of the bracket so to allow a correct installation of the exhaust hose (see figure 6).

AIR CONDITIONING WITH INSTALLATION

  • F it the air exhaust hose (B2) in the relevant housing located on the rear side of the appliance (fig. 1).
  • Drill a hole 150 mm in an outside wall or through a window panel. Respect the distances, dimensions, and height of the hole given in figure 8.

| |
---|---|---
in the window panel| in the wooden kickboard of a
French window| in the wall: you are recommended to insulate the section of wall using suitable insulation.

  • Fit the wall flange (B1) into the hole.

  •  Fit the air exhaust hose (B2) into the wall flange (B1) (Fig. 9)

  •  When the hose (B2) is not connected, the drilled hole can be closed with the flange cap (B1).
    Please note: As special tools are required for installation, we suggest you have the appliance installed by specialized personnel.

  • When installing the air conditioner, you should leave a door slightly open little as 1 cm to guarantee correct ventilation and room pressure.

  •  Keep the air hose as short and free of curves as possible to avoid constrictions.

OPERATING FROM THE CONTROL PANEL

DeLonghi EL 112 Air Conditioner-CONTROL PANEL
DESCRIPTION OF THE CONTROL PANEL (C)

C1  ON/STAND-BY (on/off) key
C2  Function selection key MODE (air conditioning, dehumidifying, fan)
C3 Decrease key
C4  Increase key
C5  Temperature indicator
C6  Timer indicator
C7  Timer symbol
C8  Air conditioning symbol
C9  Dehumidifying symbol| C10  Fan symbol
C11  ECO REAL FEEL indicator
C12  SILENT symbol
C13  Auto indicator
C14  Airflow indicators
C15  Alarm symbol
C16  ECO REAL FEEL symbol
C17  Set temperature values, programmed on/off time
---|---

TURNING THE APPLIANCE ON/OFF

,DeLonghi EL 112 Air Conditioner-TURNING THE APPLIANCE
ON| Before plugging the appliance check the cap on the back of the unit is correct­ly inserted on the drainage hose (A10). Insert the plugin into the socket.
Two dashes appear on the display indicating that the appliance is in stand-by.
Touch the (C1) key to turn on the appliance.
When the appliance comes on, the last function set before it was shut off is activated.
Please note: After few seconds of the control panel inactivity, its brightness will be automatically re- , duced and in the next few minutes, it will be further reduced.
“I To turn the appliance off, touch the  (C1) key again.
---|---

Please note: Never turn off the air conditioner by simply pull­ing the plug. Touch the (C1) key in order to put your air conditioner on stand-by and wait a few minutes before pulling the plug. In this way, the appliance can perform operating status checks.

MODES SELECTION

To select the desired operating mode, touch repeatedly the MODE key (C2) until the desired function is selected.
AIR CONDITIONING MODE

DeLonghi EL 112 Air Conditioner-AIR CONDITIONING MODE
This is ideal for hot and humid weather when the room needs to be both cooled and dehumidifier. To correctly set this mode:

  •  Touchrepeatedly the MODE key (C2) until the air conditioning symbol appears. The display will show the desired temperature and the AUTO fan speed.
  •  To change the temperature to be reached, touch the (C4) or (C3) key.

Please note  The most suitable temperatures, during the summer range from 24 to 27°C. However, setting a temperature significantly lower than the outdoor
temperature is not recommended.
In conditioning mode, the airflow can be selected only from the remote control.
DEHUMIDIFYING MODE This is ideal for reducing humidity in the room (spring and autumn, damp rooms, rainy periods, etc). For this type of use, the appliance must be set up as for air conditioning mode. That is, the air exhaust hose (B2) must be fitted to the appliance to allow the humidity to be discharged outside.
To correctly set this mode:
•Touch repeatedly the MODE key (C2) until the dehumidifying ****symbol appears.
• The appliance automatically chooses the best airflow.
FAN MODE
When using this mode, the air exhaust hose (B2) does not need to be attached to the appliance. To correctly set this mode:

  • Touch repeatedly the MODE key until the fan symbol appears.
  • Select the desired airflow by touching the increase (C4) or decrease    (C3) key.

The air flows available are:
( )Minimum airflow: when most silent operation is desired.
(( ))Medium airflow: when the noise level needs to be low but with a good comfort level.
((( )))Maximum airflow : for maximum performance.

SELECT THE TEMPERATURE SCALE

DeLonghi EL 112 Air Conditioner-SELECT THE
TEMPERATURE SCALE

The temperature can be displayed in °C or °F. To change the temperature unit of measure touch both the increase (C4) or decrease   C3) keys for about 10 sec.

OPERATING FROM THE CST (Cool Surround Technology) REMOTE CONTROL

The CST remote controller is based on Bluetooth® Low Energy communication with the Pinguino.

INSERTING OR REPLACING THE BATTERIES

  •  Remove the cover on the rear of the remote control.
  • Insert or replace the batteries with two new LR6 “AA” 1.5V batteries, inserting them correctly (see the instructions inside the battery compartment) (fig. 10).
  • Replace the cover.

If the remote control unit is replaced or discarded, the batteries must be removed and disposed of in accordance with current legislation as they are harmful to the
environment. Do not mix old and new batteries.
Do not mix alkaline, standard (carbon-zinc), or rechargeable (nickel-cadmium) batteries. Do not dispose of batteries in a fire. Batteries may explode or leak. If the remote control is not be used for a certain length of time, remove the batteries.
Use only battery within the expired date.

DESCRIPTION OF THE CST REMOTE CONTROL

DeLonghi EL 112 Air Conditioner-REMOTE CONTROL

D1 ON/STAND-BY (on/off) button
D2 SILENT button
D3 Air flow button
D4 Decrease button
D5 Countdown Timer
D6 MODE button
D7 Increase button
D8 ECO REAL FEEL button
D9 Swing button (flap swing)
D10 Indication LED

USING THE CST REMOTE CONTROL

The CST remote control is an innovative technology that allows a better well beings regulation, thanks to the sensors provided. In order to optimize the wellbeings conditions around you, we suggest you keep it near you.

  • The remote control must be no more than about 10 meters away from the appliance (fig. 10) (even in nonline of sight). The maximum range may be lower depending on the envi­ It belongs to the Bluetooth class 2 device class.

  • The CST remote control must be handled with care. Do not drop it or expose it to direct sunlight or sources of heat. It is advisable to keep the (ST remote Control Unit lied over a table or a plan surface.
    Do not hold the CST remote Control in your hand for a long time to avoid altering the reading of the sensors.
    The CST sensors are also disabled if the CST remote control is positioned at a distance less than 1 m from the unit.
    The CST remote control is equipped with touch-sensitive

  • The CST remote control is equipped with a double color built-in LED (D10) (white/red). White indications are used for
    – signaling the touching of each button with 3 fast flashes
    -every 30 seconds it blinks for data transmission
    -signaling the entering of the pairing phase with periodic blinking
    -signaling the batteries good status

  • The same indications but in red color mean that the batter­ies begin to be exhausted.

Please note: The remote control can be safely stored in the ap­propriate compartment (A11).

TURNING THE APPLIANCE ON/OFF

  • Plug into the outlet.
  • Touch the ON/STAND-BY button (D1). When turned on, the air conditioner starts operating in the same mode as when it was turned off.
  • Touch the ON/STAND-BY button (D1) again to switch the appliance off.
    Please note: Never switch the appliance off by removing the plug. Always switch it off by touching the  ON/STAND-BY button (D1) and waiting few minutes before removing the plug. Only in this way, the appliance will perform the standard checkings.

SELECTING THE OPERATING MODES

The operating modes available on the CST remote control through the MODE button (D6) correspond to those on the appliance control panel (C).

SELECTING THE TEMPERATURES

In conditioning, mode touch the button (D4) or (D7)  to select the desired temperature.

SELECTING THE AIRFLOW

In conditioning and fan modes, touch the button (D3) to select the desired airflow.
The air flows available are:
( )Minimum airflow: when most silent operation is desired.
(( ))Medium airflow: when the noise level needs to be low but with a good comfort level.
((( )))Maximum airflow : for maximum performance.
((( )))Auto airflow: the appliance automatically chooses the airflow based on the temperature selected and the environmental conditions. This selection is only available in conditioning mode.

  ECO REAL FEEL FUNCTION

ECO REAL FEEL is the innovative De’Longhi technology that works simultaneously on temperature reduction and humidity control, securing the best comfort level. With traditional systems, during working time, optimal comfort conditions may be reached but not secured over time. With ECO REAL FEEL, once optimal comfort is reached, PAC automatically modulates compressor action and airflow, to keep it over time. To activate the function, touch the button (D8) on the remote control and the ECO REAL FEEL symbol appears. After approx. 1 minute, the ECO REAL FEEL indicator (C11) turns on. It changes color when pproaching the best comfort level (see the following diagram).
Please note: For this type of use, the appliance must be set up as for air conditioning mode.

DeLonghi EL 112 Air Conditioner-MEDIUM

  • The well-being feeling is a subjective condition: for this reason, different people may judge differently the same environmental conditions.
  •  In particularly severe environmental conditions (large size of the environment, high temperature or humidity outside, C17 poor insulation of the room, too many people or strong heat load in the room, strong exposure to the sun …) this the device may not be able to reach the best comfort level.

SILENT FUNCTION (available in conditioning mode only)
By activating this function, the operating noise is further reduced. To activate it, touch on the remote control the button (D2). The display shows the elative symbol (C12).DeLonghi EL 112 Air Conditioner-SILENT
FUNCTION

SWING FUNCTION
This function moves the flap evenly distributing the air into the room.
When the Swing button (D9) is touched, the flap will begin to move forwards and backward alternatively.
If touched again, the flap will be locked into its current position.
When the button is next touched, the flap will start to move forwards and backward again.
Please note: in order to avoid damaging the internal mechanisms, the flap must not be moved manually.

REPEAT PAIRING OF CST REMOTE CONTROL

The CST remote control is already paired with the bundled Pinguino appliance. In case the user wants to perform a pairing with another Pinguino the device, or in case of a pairing of brand new CST remote control, the user needs to put the unit in Stand-by mode and keep in touch for 10 sec the ODE selection button (D6) on the CST remote control. The Led (D10) starts blinking periodically indicating the pairing phase.
The user is then asked to press for 10 sec the MODE button (C2) on the Pinguino unit until a double beep is emitted. The pairing phase is signaled on display by means of a fast flashing of the dot in the middle of the digits.
When the two devices complete the pairing dialogue, the PAC emits a double ‘beep’, the display will show the normal visualization for Standby. The pairing must  e did within 60 sec.

How to program delayed shut down

  • While the appliance is on in any operating mode, delayed
    shut down can be programmed.

  •  Touch the C7 timer button (D5): the timer symbol (C7) and C9 hours (C6) light up.

  • Touch the (D4) and (D7) buttons until the desired C4 number of hours to shut down appears on the display.

A few seconds after the timer is set, the setting is acquired, the display shows the operating mode and the timer symbol stays lit. Once the set time is elapsed, the air conditioner goes into standby.

To cancel the timer program, touch the C7 timer button (D5) C8 twice.  The timer symbol (C7) will go off.
Please note: Once the timer has been activated, by touching the timer button only one time, the remaining hours to shut down will be displayed.

How to program delayed start-up

  • Plug in the appliance and set it to standby.
  •  Touch the  timer button (D5): the timer symbol (C7) and C9 hours (C6) light up.
  • Touch the   (D4) and  (D7) buttons until the desired number of hours to start up appears. Start-up can be programmed at any time within the 24 hours that follow.

When the set time is elapsed, the appliance will start to operate in the same operating mode that was previously set. To cancel the timer program, touch the timer button (D5) twice. The timer symbol (C7) will go off. Please note: Once the timer has been activated, by touching the timer key only one time, the
remaining hours to the start-up will be displayed.

USAGE TIPS

  • The CST remote control has humidity/temperature sensors onboard. It is suggested not to completely cover it with hands or clothes; it is as well suggested not to place in obstructed airflow zones. In addition to that, it is preferable to keep the device far for direct sunlight exposure or heat sources in order to avoid miss sensor readings.
  • The CST remote control is equipped with touch-sensitive buttons. It is suggested to use it with clean hands and without dust or liquids/humidity over it.
  •  The CST remote control is expected to run for about 6 months with the same battery pack. This assumption is based on the use of 2300 mAh LR6 “AA” batteries

SELF-DIAGNOSIS

The appliance has a self-diagnosis system to identify a number of warning/malfunctions.
Error messages are displayed on the appliance display.

IF … IS DISPLAYED,| IF … IS DISPLAYED,| IF … IS DISPLAYED,| IF … IS DISPLAYED,
---|---|---|---
| | |
“Low Temperature”
(Frost prevention)| “Probe Failure” (Probe damaged)| “High Level”
(Internal tray full)| “Communication Failure”
(Internal communication issue)
..WHAT SHOULD I DO?| ..WHAT SHOULD I DO?| ..WHAT SHOULD I DO?| ..WHAT SHOULD I DO?
The appliance is fitted with a frost protection device to avoid the excessive formation of ice. The appliance starts up again auto- matically when the defrosting process is completed.| If this is displayed, contact your local authorized service center| Empty the internal safety tank following the instructions in the section”End of season operations”| If this is displayed, contact your local authorized service center.

TIPS FOR CORRECT USE

To ensure optimal results from your air conditioner, follow these recommendations:

  •  close the windows and doors in the room to be air-conditioned. When installing the air conditioner semi-permanently, you should leave a door slightly open (as little as 1 cm) to guarantee proper ventilation.
  • Never use the appliance in very damp rooms (laundries for example).
  •  Protect the room from direct exposure to the sun by partially closing curtains and/or blinds to make the appliance much more economical to run.
  •  Never use the appliance outdoors.
  •  Make sure there are no heat sources in the room.
  •  make sure the air conditioner is standing on a level surface.DeLonghi EL 112 Air Conditioner-the appliance
  • Never rest objects of any kind on the air conditioner.
  •  Never obstruct the air intake or outlet flap.

CLEANING

Before cleaning or maintenance, turn the appliance off by touching the button, then unplug from the outlet.

CLEANING THE CABINET

You should clean the appliance with a slightly damp cloth then dry with a dry cloth. For safety reasons, never wash the air conditioner with water.

Attention! Never use petrol, alcohol or solvents to clean the appliance. Never sprayinsecticide liquids or similar.
CLEANING THE BIO SILVER AIR FILTER
The BioSilver filter helps capture dust and pollen and helps reduce the growth of bacteria and mold on the filter.
If the filter is dirty, air circulation is compromised and the efficiency of the appliance decreases. It is therefore good practice to clean the filter at regular intervals.
The frequency depends on the duration and conditions of operation. If the unit is used constantly or systematically, you are recommended to clean the filter once a week.
The filter is housed in the intake grille.
To clean the filter, extract as shown in fig. 11.
Use a vacuum cleaner to remove the dust collected on the filter. If it is very dirty, immerse in warm water and rinse a number of times. The water should never be
hotter than 40°C.
After washing the filter, allow it to dry completely before repositioning it.
START OF SEASON CHECKS
Make sure the power cable and plug are undamaged and the earth system is efficient.
Follow the installation instructions precisely.
END OF SEASON OPERATIONS
To drain all water from the circuit, remove the external cap by unscrewing it in the anticlockwise direction (fig. 12) and allow the water to drain out into a basin. When the appliance is empty, replace the caps.
Clean the filter and dry it thoroughly before putting it back.
TECHNICAL SPECIFICATIONS
Power supply voltage   see rating label
Max. absorbed power
during air conditioning       “
Refrigerant                          “
Cooling capacity                 “
Frequency:   2402.0-2480.0 MHz
Maximum transmission power   0,00137 W
LIMIT CONDITIONS
Room temperature for air conditioning    18° ÷ 35°C
Transport, filling, cleaning, recovery, and disposal of refrigerant should be performed by a technical service center appointed by the manufacturer only. The appliance should be disposed of by a specialist center appointed by the manufacturer only.
Attention! TO AVOID DAMAGE TO THE UNIT:
NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR ON ITS SIDE. IF THIS OCCURS, WAIT 6 HOURS BEFORE TURNING THE APPLIANCE ON, 24 HOURS IS RECOMMENDED. After the unit has been on its side, oil needs to return to the compressor to ensure proper
function. Without allowing the unit this time (6-24 hours) the unit may function for only a short time, and then the compressor will break down from lack of oil.

TROUBLESHOOTING

PROBLEM CAUSE SOLUTION
The air conditioner does not come on it is not plugged into the outlet plug

into the outlet
there is no current| wait
the internal safety device has tripped| call the Service Center
The air conditioner works for a short time only| there are bends or kinks in the air exhaust hose| position the air hose correctly, keeping it as short and free of curves as possible to avoid bottlenecks
something is preventing the air from being discharged| check and remove any obstacles obstructing air discharge
The air conditioner works but does not cool the room| windows, doors and/or curtains open| close doors, windows and curtains, bearing in mind the”TIPS FOR CORRECT USE” given above
there are heat sources in the room (oven, hairdryer, etc| eliminate the heat sources
the air exhaust hose is detached from the appliance| fit the air exhaust hose in the housing at the back of the appliance (fig. 1).
filter clogged| clean or replace the filter as described above
the technical specification of the appliance is not adequate for the room in which it is located.|
During operation, there is an unpleasant smell in the room| filter clogged| clean the filter as described above
The air conditioner does not operate for about three minutes after restarting it| an internal safety device prevents the appliance from being restarted until three minutes have elapsed since it was last turned off| the wait. This delay is part of a normal operation.
The scripts Lt/PF/HL/EI  and the symbol appear on display.| the appliance has a self-diagnosis system to identify a number of malfunctions.| see the SELF- DIAGNOSIS chapter

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals