Medic Therapeutics Air Purifier: Large Room HEPA H13 Filter User Manual

June 7, 2024
MEDIC THERAPEUTICS

The Medic Therapeutics Large Room Air Purifier with Hepa H13 Filter User Manual provides detailed instructions on how to safely and effectively use the air purifier. The manual includes information on important safety precautions, product specifications, and care and maintenance instructions. Users are advised to read the manual carefully and keep it for future reference. The air purifier is designed to efficiently purify the air in large rooms by removing pollutants such as PM 2.5, smoke, pollen, and other particulate pollutants. The 4-in-1 air cleaning system includes a pre-filter, HEPA filter, modified activated carbon, and air ionizer. The manual also includes instructions on how to install filters, turn on the air purifier, and use the touch button control panel operations. Additionally, the manual provides guidance on how to clean and maintain the air purifier to ensure its longevity and optimal performance. Overall, the Medic Therapeutics Large Room Air Purifier with Hepa H13 Filter User Manual is a comprehensive guide that provides users with all the necessary information to safely and effectively use the air purifier.

LARGE ROOM AIR PURIFIER WITH HEPA H13 FILTER
User Manual

Read this instruction manual carefully and keep it for future reference. Always refer to the actual product, as the images in this manual are for reference only.

IMPORTANT SAFETY INFORMATION

This product should only be used in accordance with the specifications outlined in this manual. Usage other than what has been specified here may result in serious injury.
While using electronic appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and bodily injury including the following:
Before Use

  • WARNING: To reduce the risk of fire or electric shock, do not use this device with any solid-state speed control device.
  • Please connect the product power supply with the adapter corresponding to the voltage.
  • To avoid any electric shocks or fire hazards, please clench the plug, do not pull the power cord.
  • To avoid any damage to the power cord, electric shocks, or fire disasters, do not pull, bend, warp, destroy the power cord intentionally.
  • Do not use the device if the power cord/plug/socket has been damaged and contact the manufacturer directly for repair or replacement information.
  • To avoid any electric shocks or fire disasters caused by damage to the power cord, do not put the weights on the power cord.
  • Do not touch the power plug with wet hands.

In Use

  • Remove the plastic layer of the filter and do not use the device without filters.
  • Never drop or insert any object into any openings.
  • Do not clog or block an air inlet or outlet.
  • Do not use close-to-hot objects (like stoves, open flame, or gas heating sources).
  • Unplug immediately if any malfunction happens like smoking, emitting an odor, etc.
  • To ensure the natural flow by air and efficiency of purification, always allow for plenty of space surrounding the device.

Additional Precautions

  • Do not use the device near the fire and flammable chemicals.
  • To avoid any electric shock, fire, or any other damages, do not use the device near any propane, gas, natural gas, or any other flammable sources.
  • Do not use or apply bug spray near the device.
  • To avoid any electric shock, fire disaster, or any other damages, do not use the device in any unstable locations, in extreme temperatures, or damp areas such as bathrooms, etc.

Care & Maintenance

  • Do not clean and reuse the composite filter and do not clean the device with a corrosive chemical cleanser.
  • To avoid any damage or malfunction of sensors, always clean the device with a soft cloth.
  • To avoid any damage, electric shock or fire, do not clean the device with ethyl alcohol or organic solvent.
  • To avoid any electric shock or fire, always power off and clean and then wipe off the plug when cleaning the device.

Storage

  • Always keep the device stored in dry places.
  • Always keep the device away from flammable and combustible areas.
  • Store using the protective cover.

Tips

  • Not suitable for use by disabled persons or those with perceptual disturbances, diagnosis users, or children.
  • Do not lean on or rest against the device to avoid any injury.
  • Unplug when moving the device.
  • If the supply cord or any machine parts are damaged, contact the manufacturer directly for repair or replacement information.
  • Contact the manufacturer directly if any odor is emitted from the filter.
  • The cord, wires, and/or cables supplied with this product contain chemicals, including lead or lead compounds, known to the state of California to cause cancer and birth defects, or other reproductive harm.
    Wash hands after using. (California Code of regulation Proposition 65)

PRODUCT SPECIFICATIONS

CADR particulate 400m3/h
CCM particulate P4 (the highest level)
CCM formaldehyde F4 (the highest level)
Coverage area 25-50m’
Noise level 27-65dB
Color white/customized
Voltage 110V 50/60Hz
Power 40W
Product size 322’322’605mm
Carton packaged size 375’375’625mm
N.W/G.W 10kg/11kg

PRODUCT OVERVIEW

Included in Packaging:

Air Purifier 1 Item
Composite filter 2 Pieces (assembled in the appliance)
Power line 1 Piece (in accessories box)
Instruction Manual 1 Copy (in accessories box)
  • High-efficiency Purification of PM 2.5, Smoke, Pollen, and Other Particulate Pollutants.
  • Removal of HCHO, C6H6, VOC, etc.
  • 4 – Gear Wind Speed Design
  • Timer Setting
  • Filter Replacement Reminder
  • Availability of Multiple Operation Modes, Auto and Sleep Mode
  • Laser Sensor Real-time Display of PM2.5 Value

4-in-1 Air Cleaning System:
Pre-filter → High-Efficiency Particulate Air (HEPA) Filter → Modified Activated Carbon → Air Ionizer
Pre-filter
Blocks hair, fibers, big particulates, etc., and can be washed regularly.
HEPA Filter
Efficiently filter out the particles as small as 0.01microns (e.g. PM2.5, smoke, pollen, acarid,, and other pollutants).
Modified Activated Carbon
High-quality modified activated carbon and catalyst are utilized. They are modified with special proprietary technology, and can efficiently purify methanol, benzene series, VOC, and other odorous pollutants.
Air Ionizer
Disperses negative ions to seek out and remove particles & bacteria from the air, keeping you alert and active.
*Note: Pre-filter, High-efficiency activated carbon and high-efficiency HEPA are incorporated in the same filter.

PRODUCT SPECIFICATIONS
Precautions for Use:

  • All filters have been installed in this air purifier.
  • Check filters are installed properly.
  • Check filter handle is towards you.

Installation of Filters

1. Place your fingers on the handle.| 4. Remove all packaging films from the filters.
---|---
2. Move upward to remove the filter cover.| 5. Re-install the filters.
3. Take out the new filters with plastic film from the appliance.| 6. Re- install the covers.

How to Turn On
Connect the power to enter the standby configuration, the power indicator lights up.
Touch Button Control Panel Operations
With the easy-to-use control panel, you can select between 4 fan speeds, sleep mode, timer, and optional ionizer.

| The negative ion function is on by default (the screen will display the icon).
Touch this button to toggle the ion On/Off.
---|---
| Touch this button to set the timer to power off from now on. Each touch will switch among off, 1hr, 2hr, 4hr, 8hr.
|

When this button is pressed, the air purifier will be set on Sleep Mode.
The control panel’s lights will turn off and the appliance will operate at the minimum speed.
This ultra-quiet operation means undisturbed sleep and waking up with clean fresh air.

| Touch this button to switch from Auto Mode to Manual Mode.
In Manual Mode, the speed of the fan can be adjusted as needed and can be set back to Auto Mode by pushing the button again. (The screen will display each kind of mode that is active).
|

In standby mode, the light will be off.
Press this button, the light will become bright and the appliance is turned on changing into auto mode; Press the button again, the appliance will go into standby mode.
To completely shut down the appliance, the power plug should be removed from the socket.

Display Status

|
---|---

Note: PM 2.5 is defined as fine dust particles of a diameter of 2.5 micrometers or less.

**** Negative ion function **** : Manual mode adjustment
Sleep mode Timer 1—8 Hrs
Fan speed (1-4 speeds) adjusts automatically according to the air quality.
1—2—3—4 fan speed level
Filter replace reminder  

CLEANING & MAINTENANCE

Please unplug the machine if not being used.

  1. Clean the body

  2. Use a soft cloth to remove any stains.

  3. Stubborn stains that cannot be easily removed can be wiped with a moderate amount of neutral detergent, using a soft cloth.
    Note: Do not scratch the machine casing with hard objects during maintenance.
    When removing the front cover, please follow the instructions and do not damage the machine parts.

  4. Cleaning and replacement of the filter:

  1. The filter replacement is reminded by the built-in program. However, due to the different degrees of pollution in the actual application environment, the use cycle of the filter will be different, and it can be replaced in time according to the size and smell of the sound generated by the machine.
  2. When the surface of the composite filter is dusty, use a vacuum cleaner to clean the surface dust to extend the filter’s life expectancy. (It is recommended to clean every 2 months)

| Replace time|

Condition

---|---|---

Composite Filter

| Replace approximately after every 10 to 12
months of use| In a household where there is an absorption of 4-6 cigarettes per day

Depending on the place of use and the method of use (for example, households with a large number of smokers), the cycle of filter replacement may be shortened. If the effect is not good, please replace it in time.
Dispose of the filter as non-combustible refuse.

TROUBLESHOOTING

Problem| Possible Causes|

Remedial Action

---|---|---
Product works abnormally| 1. There is a problem with the connection.
2. The filter cover is not placed properly| 1. Please check whether the plug is inserted into the socket. and “On/Off” button status.
2. Re-install the filter.
Fresh air cannot be delivered from the air outlet smoothly| 1. The plastic package of the new filter is not removed.
2. The air outlet of the purifier is blocked by foreign matter.| 1.  Remove the filter plastic package.
2.  Clear away the foreign matter.
Poor odor removal effect| 1. The ambient air quality of the room is very poor.
2. The high-efficiency activated carbon filter is in failure due to environmental factors.
3. The room exceeds the effective area of this product| 1. Open the window to improve air venti­lation.
2. Please replace the high-efficiency activated carbon filter mesh.
3. Use in a smaller room.
The appliance

generates an abnormal sound while running

| 1.     The air inlet or air outlet is blocked by a foreign matter
2.   Foreign matter falls into the air tube| 1.  Please clear the blocking object.
2.  Clear the fallen foreign matter.
PM2.5 values do not ever reduce and stay only in the higher values.| 1. The sensor cover has accumulated a lot of dust.
2. The unit is being operated in a dusty environment| 1.  Clean the sensor cover.
2.  Adjust the air purifier operating speed to high speed.

The above table lists the common problems with this product.
If you cannot find the answer, please contact our after-sales service center.

WARRANTY

Limited Lifetime Warranty
Your Medic Therapeutics product is backed by a limited lifetime manufacturer’s warranty. Medic Therapeutics will repair or replace your device at any time should it fail due to a defect in material or workmanship, subject to certain limitations.
This limited warranty does not cover any damage that results from unauthorized or improper use, service, or repair. Further, it does not cover damage caused by accident, impact, negligence, or normal wear and tear.
Should you discover your Medic Therapeutics product is not functioning properly, please send your device to our repair center for evaluation. If your product cannot be repaired or serviced, we will reserve the right to change it for a similar or newer model.
Please note that a flat rate of $35.00 will be charged to cover a service evaluation fee and return shipping of your device. All warranty claims must be accompanied by a copy of your proof of purchase from an authorized retailer. Please send your device, proof of purchase, and a check or money order in the amount of $35.00 made out to Medic Therapeutics to:

Address:
Medic Therapeutics Service Center
3069 Taft Street
Hollywood, FL 33021
Contact:
warranty@medictherapeutics.com

SPECIFICATION

Medic Therapeutics Air Purifier

|

1 Large Room HEPA H13 Filter User Manual
2. The power supply voltage is unstable. 3. The filter is not installed properly.
4. The air inlet or outlet is blocked

---|---

|

1. Check the power cord and plug connection.
2. Check the voltage stability.

3. Check the filter installation.

4. Check the air inlet and outlet for any blockages.

Fan speed is low

|

1. The filter is dirty.

2. The air inlet or outlet is blocked. 3. The fan speed is set to low.

|

1. Clean or replace the filter. 2. Check the air inlet and outlet for any blockages. 3. Adjust the fan speed to a higher level.

The air purifier emits an odor

|

 1. The filter needs to be replaced. 2. The air inlet or outlet is blocked.

|

 1. Replace the filter. 2. Check the air inlet and outlet for any blockages.

|

|

FAQS

What is the Medic Therapeutics Large Room Air Purifier with Hepa H13 Filter designed to do?

What is included in the packaging of the Medic Therapeutics Large Room Air Purifier with Hepa H13 Filter?

What is included in the packaging of the Medic Therapeutics Large Room Air Purifier with Hepa H13 Filter?

The packaging includes the air purifier, composite filter, power line, and instruction manual.

How do I install the filters for the Medic Therapeutics Large Room Air Purifier with Hepa H13 Filter?

To install the filters, place your fingers on the handle, move upward to remove the filter cover, take out the new filters with plastic film from the appliance, remove all packaging films from the filters, re-install the filters, and re-install the covers.

How do I turn on the Medic Therapeutics Large Room Air Purifier with Hepa H13 Filter?

Connect the power to enter the standby configuration, and the power indicator lights up.

How do I use the touch button control panel operations for the Medic Therapeutics Large Room Air Purifier with Hepa H13 Filter?

With the easy-to-use control panel, you can select between 4 fan speeds, sleep mode, timer, and optional ionizer.

How do I clean and maintain the Medic Therapeutics Large Room Air Purifier with Hepa H13 Filter?

To clean and maintain the air purifier, use a soft cloth to remove any stains, clean the body with a moderate amount of neutral detergent using a soft cloth for stubborn stains, clean and replace the filter as needed, and unplug the machine if not being used.

What are some important safety precautions to follow when using the Medic Therapeutics Large Room Air Purifier with Hepa H13 Filter?

Some important safety precautions to follow include not using the device near fire or flammable chemicals, not using the device near any propane, gas, natural gas, or any other flammable sources, not using or applying bug spray near the device, and not using the device in any unstable locations, in extreme temperatures, or damp areas such as bathrooms, etc.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEDIC THERAPEUTICS User Manuals

Related Manuals