GE APPLIANES UVD6301DP Universal 30″ Telescopic Downdraft System Installation Guide

June 7, 2024
GE APPLIANES

** UVD6301DP
Universal 30″ Telescopic Downdraft System**GE APPLIANES UVD6301DP
Universal 30 Telescopic Downdraft System

DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
NOTE: Telescopic downdraft vents are not recommended to be installed with cooktops that are flush-mounted. Approved for use with the following Monogram, GE  rofile™ Series and GE® Series cooktops–30″  electric models, 30″ gas sealed-burner models, and 30″ induction models.
NOT APPROVED FOR USE WITH STANDARD BURNER GAS COOKTOPS.
NOTE: The countertop must be at least 26″ deep with a flat surface area of 23-1/2″ or more, front to back. In addition, other clearances to the front edge of the countertop must be considered.
NOTE: Dimensions shown are for reference only. Before cutting out the countertop, refer to instructions packed with downdraft and cooktop.
NOTE: Installation of cabinets/countertops against the wall will not be possible in most applications.  Against the wall, installations are limited to dimension requirements.  Refer to installation instructions packed with the product for further details.

VENTING DUCT INFORMATION
GE APPLIANES UVD6301DP Universal 30 Telescopic Downdraft System - VENTING
DUCT INFORMATION PLAN THE DUCTWORK

  1. This downdraft blower system is designed for use with 3-1/4″ x 10″ ductwork (can be transitioned to 6″ round). Two different discharge directions are available with side-to-side adjustment for the accurate alignment of ductwork.
  2. For best performance: choose the ducting option which allows the shortest length of ductwork and a minimum number of elbows and transitions. Check the location of floor joists, wall joists, wall studs, electrical wiring or plumbing for possible interference.

STEPS TO DETERMINE FLEXIBLE DUCTING’S
EQUIVALENT LENGTH

  1. Measure the actual amount of offset (Maximum 3″ recommended). The effect upon airflow is dependent upon the amount of offset.
  2. Calculate the equivalent ducting allowances using: (in. offset) x (14 ft. per inch) =ft. equivalent length.
  3. The total equivalent length of ducting should not exceed the maximum recommendation of 100 feet for optimal venting performance.

FEATURES AND BENEFITS

GE APPLIANES UVD6301DP Universal 30 Telescopic Downdraft System - FEATURES
AND BENEFITSN 500 CFM – Make sure everyone is focused only on your food with a 500-CFM venting system that removes smoke, grease, odors, and moisture from the air.
Adjustable fan speed – Adjust your vents to match your cooking techniques with infinite fan control that removes grease, odors, and moisture.
Grease filters – Keep your clean-up to a minimum with a removable grease filter that helps eliminate hand scrubbing.
Aluminum mesh filters – Easy to remove, dishwasher safe.
Hides into countertop – Raises over cooktop surface and retracts when not in use.
Model UVD6301DPBB – Black

****For answers to your Monogram, GE Café™, GE Profile™ or
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center® Service, 800.626.2000.


Specification Revised 1/21

Documents / Resources

| GE APPLIANES UVD6301DP Universal 30" Telescopic Downdraft System [pdf] Installation Guide
UVD6301DP, Universal 30 Telescopic Downdraft System
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

GE APPLIANES User Manuals

Related Manuals