GE APPLIANES AHY08 Room Air Conditioner User Manual
IMPORTANT SAFETY INFORMATION
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE
For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.
- This air conditioner must be properly installed in accordance with the Installation Instructions before it is used.
- Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the receptacle.
- Replace immediately all electric service cords that have become frayed or otherwise damaged. A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.
- Turn the unit OFF and unplug your air conditioner before cleaning.
- For your safety…do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
- If the receptacle does not match the plug, the receptacle must be changed out by a qualified electrician.
Risk of Fire or Explosion. This unit contains flammable refrigerant. Additional safety precautions must be followed.
- Do not use means to accelerate the defrosting process to clean, other than those recommended by the manufacturer.
- The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater.
- Do not pierce or burn refrigerant tubing. Be aware that refrigerants may not contain an odor.
- Keep ventilation openings clear of obstruction.
- When handling, installing, and operating the appliance, care should be taken to avoid damage to the refrigerant tubing.
- Do not drill holes in the unit.
- Maintenance, cleaning, and service should only be performed by technicians properly trained and qualified in the use of flammable refrigerants.
- GE Appliances does not support any servicing of the air conditioner.
- Dispose of air conditioner in accordance with Federal and Local Regulations. Flammable refrigerants require special disposal procedures. Contact your local authorities for the environmentally safe disposal of your air conditioner.
IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE
USE OF EXTENSION CORDS RISK OF FIRE.
Could cause serious injury or death.
■ DO NOT use an extension cord with this Window Air Conditioner.
■ DO NOT use surge protectors or multi-outlet adaptors with this Window Air
Conditioner.
HOW TO CONNECT ELECTRICITY
Do not, under any circumstances, cut or remove the third (ground) prong
from the power cord. For personal safety, this appliance must be properly
grounded.
DO NOT use an adapter plug with this appliance.
The power cord of this appliance is equipped with a 3-prong (grounding) plug
which mates with a standard 3-prong (grounding) wall outlet to minimize the
possibility of electric shock hazard from this appliance. Power cord includes
a current interrupter device. A test and reset button is provided on the plug
case. The device should be tested on a periodic basis by first pressing the
TEST button and then the RESET button while plugged into the outlet. If the
TEST button does not trip or if the RESET button will not stay engaged,
discontinue use of the air conditioner and contact a qualified service
technician.
Have the wall outlet and circuit checked by a qualified electrician to make
sure the outlet is properly grounded. Where a 2-prong wall outlet is
encountered, it is your personal responsibility and obligation to have it
replaced with a properly grounded 3-prong wall outlet. The air conditioner
should always be plugged into its own individual electrical outlet which has a
voltage rating that matches the rating plate. This provides the best
performance and also prevents overloading house wiring circuits which could
cause a fire hazard from overheated wires. See the Installation Instructions,
Electrical Requirements section for specific electrical connection
requirements.
Chemical Burn Hazard. Keep batteries away from children.
■ This product contains a lithium button/coin cell battery. If a new or used
lithium button/coin cell battery is swallowed or enters the body, it can cause
severe internal burns and can lead to death in as little as 2 hours. Always
completely secure the battery compartment. If the battery compartment does not
close securely, stop using the product, remove the batteries, and keep it away
from children.
■ If you think batteries might have been swallowed or placed inside any part
of the body, seek immediate medical attention.
■ The cells shall be disposed of properly, including keeping them away from
children.
■ Even used cells may cause injury.
Controls
Features and appearance will vary. Lights beside the touch pads on the air conditioner control panel indicate the selected settings.
- Power Pad Turns air conditioner on and off. When turned on, the display will show the room temperature.
- Display Shows the room temperature or time remaining on the Delay timer. Shows the Set temperature while setting the temperature in Cool or Eco modes.
- Temp and Delay Increase + /Decrease – Pads Use to set temperature or delay time. Temperature can be set in Cool and Eco mode.
- Mode Pad Use to set the air conditioner to Fan Only, Cool, or Eco mode.
- Fan Speed Pad In Cool or Eco mode: Use to set the fan speed to Auto, High, Med or Low on the unit. In Fan Only mode: Use to set the fan speed to High, Med, or Low on the unit.
- Delay Pad (set by remote control only) Delay ON—When the air conditioner is off, it can be set to automatically come on in 1 to 24 hours at its previous mode and fan settings. Delay OFF—When the air conditioner is on, it can be set to automatically turn off in 1 to 24 hours. How to set: Press the Delay pad on the remote control. Each touch of the Increase + / Decrease – pads on the remote control will set the timer in 1-hour intervals. To review the remaining time on the Delay timer, press the Delay pad on the remote control. Use the Increase + / Decrease – pads on the remote control to set a new time if desired. To cancel the timer, press Decrease v pad on the remote control until the set time is zero.
- Sleep Pad (set by air conditioner controls only) The SLEEP mode sets the unit to gradually change settings over an 8 hour period to allow for some increased energy efficiency during sleep hours. The SLEEP mode is available only in COOL and FAN only settings. Press the SLEEP mode pad and its light will illuminate. The fan indicator will stay at the same setting but the air conditioner will automatically change the FAN speed to low in either COOL or FAN only mode. In FAN only mode, the fan will stay in the LOW speed setting for 8 hours. After 8 hours, the air conditioner will resume the settings that were in place before the SLEEP mode pad was pressed. In COOL mode, the fan will stay in the LOW speed setting for 8 hours from the time the SLEEP mode pad was pressed The air conditioner will also raise the set point 2°F in 30 minutes and 2°F more in another 30 minutes where it will remain for the next 7 hours. After 8 hours, the air conditioner will resume the settings that were in place before the SLEEP mode pad was pressed. While the unit is in SLEEP mode, pressing any pad will return it to the settings that were in place before the SLEEP mode pad was pressed.
- Filter Reset Pad This feature automatically notifies you that the air filter must be cleaned. The indicator light will come on after 250 hours of operation. Clean the air titter (refer to page 6), place it back in the front panel, and press the Fitter Reset pad. The light will go off.
- WiFi Connect Pad Enables connection of the air conditioner to the home WiFi. Download App for details at:I www.GEAppliances.comiconnect.
Using the Air Conditioner
Do Not Operate in Freezing Outdoor Conditions
This cool-cnly air conditioner was not designed for freezing It must not be
used when the outdoor temperature is below outdoor conditions. freezing
(32°F).
Control Panel Lights On/Off Feature
This air conditioner has a control panel lights on/off feature where its
lights will turn off when there is no activity with the controls for over one
minute. To wake up the controls, press any pad on the controls and the lights
will come on to show the previous settings. To turn this feature off, press
and hold the SLEEP pad, on the unit, for 5 seconds. The unit will beep to
signal the successful toggle of the feature on and off.
Remote Control
■ To ensue proper operation, aim the remote control at the signal receiver an
the air conditioner.
■ The remote control signal has a range of up to 20 feet
■ Make sure nothing is between the air conciticner and the remote control that
could block the signal.
■ Make sure batteries are fresh and installed correctly as indcated on the
remote control.
Cool Mode
Use the Cool mode at Low, Med, High or Speed for cooling. Use the Temperature
Increase + / Decrease -pads to set the desired temperature between 64°F and
86°F in 1°F increments. An electronic thermostat is used to maintain the room
temperature. The compressor will cycle on and off to keep the room at the set
level of comfort. Set the thermostat at a lower number and the indoor air will
become cooler. Set the thermostat at a higher number and the indoor air will
become wanner.
NOTE: If the air conditioner is off and is then turned on while set to a
Cool setting or if turned from a fan setting to a Cool setting, it may take
approximately 3 minutes for the compressor to start and cooling to begin.
Cooling Descriptions For Normal Cooling—Select the Cool mode and High or Med
fan with a middle set temperature. For Maximum Cooling—Select the Cool mode
and High fan with a lower set temperature. For Quieter and Nighttime
Cooling—Select the Cool mode and Low fan with a middle set temperature.
Eco Mode
Controls the fan.
ON— The fan will cycle on and off with the compressor. This may result in
wider variations of room temperature and humidity. NOTE: the fan may continue
to run for a short time or may pulse intermittently after the compressor
cycles off to sample the room air.
OFF— The fan runs all the time, while the compressor cycles on and off.
Fan Only Mode
Use the Fan Only Mode at Low, Med or high fan speed to provide air
circulation and filtering without cooling. Since fan-only settings do not
provide cooling, a Set temperature cannot be entered. The room temperature
will appear in the display.
Auto Fan Mode
Set to Auto for the fan speed to automatically set to the speed needed to
provide optimum comfort settings with the set temperature.
If the room needs more cooling, the fan speed will automatically increase. If
the room needs less cooling, the fan speed will automatically decrease.
Using the Air Conditioner
Air Direction
Use the levers to adjust the air direction left or right. Tilt the louver bank
to adjust up and down.
Care and Cleaning
Grille and Case
Turn the air conditioner off and remove the plug from the wall outlet before
cleaning. To clean, use water and a mild detergent. Do not use bleach or
abrasives.
Air Filter
The air filter behind the front grille should be checked and cleaned at least
every 30 days or more often if necessary.
To remove:
Open the inlet grille by pulling downward on the tabs at pie top upper comers
of the inlet grille until the grille is in a 45° position. Remove the fitter.
Clean the fitter with warm, soapy water. Rinse and let the fitter dry before
replacing it. Do not clean the filter in a dishwasher.
CAUTION
DO NOT operate the air conditioner without a filter because dirt and lint will
clog it and reduce performance.
Outdoor Coils
The coils on the outdoor side of the air conditioner should be checked
regularly. If they are clogged with dirt or soot, they may be professionally
cleaned.
**How to Insert the Battery in the Remote Control
**
1. Remove the screw on the back of the battery cover.
2. Pinch the slide lock and pull the battery tray out at the same time.
3. Insert new battery, making sure that the (+) and (—) of battery are
installed correctly.
4. Reinsert the battery tray and reinstall the screw.
NOTES:
■ Use one CR 2025 (3V) Lithium battery.
■ Remove the battery from the remote control if the system is not going to be
used for a long time.
Installation Instructions
‘Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at:
GEAppliances.comi
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT — Save these
instructions for local inspector’s use.
IMPORTANT — observe all governing codes and ordinances.
• Note to Installer – Be sure to leave these instructions with the
Consumer.
• Note to Consumer – Keep these instructions for future reference.
• Skill level – Installation of this appliance requires basic mechanical
skills.
• Completion time – Approximately 1 hour
• We recommend that two people install this product.
• Proper installation is the responsibility of the installer.
• Product failure due to improper installation is not covered under the
Warranty.
• You MUST use all supplied parts and use proper installation procedures as
described in these instructions when installing this air conditioner.
ELECTRICAL REQUIREMENTS
These models require a 115/120-volt AC, 60-Hz grounded outlet protected with a
15-amp time-delay fuse or circuit breaker. The 3-prong grounding plug
minimizes the possibility of electric shock hazard. If the wall outlet you
plan to use is only a 2-prong outlet, it is your responsibility to have it
replaced with a properly grounded 3-prong wall outlet.
CAUTION
Do not, under any circumstances, cut or remove the third (ground) prong from
the power cord.
Do not change the plug on the power cord of this air conditioner.
Aluminum house wiring may present special problems— consult a qualified electrician. Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet. lithe TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
Installation Instructions
Installation Instructions
1. WINDOW REQUIREMENTS
• These instructions are for a standard double-hung window. You will need to
modify them for other types of windows.
• The air conditioner can be installed without the side curtain panels if
needed to fit in a narrow window. See the window opening dimensions.
• All supporting parts must be secured to firm wood, masonry or metal.
• The electrical outlet must be within reach of the power cord.
• Follow the dimensions in the table and illustration for your model.
Models | A | B |
---|---|---|
AHY08 | 13 3/8´ PiQ | 24 1/2´-36´ |
$+<10/$+<12 | 14 9/16´ PiQ | 25´ – 36 5/8´ |
AHY14 | 15 5/8´ | 26 1/8´ – 37 3/4´ |
2. STORM WINDOW REQUIREMENTS A storm window frame will not allow the air
conditioner to tilt toward the outside, and will keep it from draining
properly. To adjust for this, attach a piece of wood to the sill. WOOD PIECES
WIDTH: 2• LENGTH: Long enough to fit inside the window frame. THICKNESS: To
determine the thickness, place a piece of wood on the sill to make it 1/2′
higher than the top of the storm window frame or the vinyl frame. Attach
securely with nails or screws provided by the installer.
3. PREPARE THE AIR CONDITIONER
A. Install the top mounting rail with 4 Type A screws (AHY10 / AHY12 / AHY14)
or 3 Typo A screws (AFIY08) from the outside of the case.
B. Apply the weather seals provided to the bottom, top and sides of the window
to the seal around the perimeter of the air conditioner.
C. Slide the side curtain panels in o the side panel rails
D. Slide left and right side curtain frames into top and bottom rails. Make
sure that side curtains snap into side of the frames.
4. INSTALL THE AIR CONDITIONER IN THE WINDOW
A. Mark the center of the window. Set the air conditioner in the window so
that is it centered. Place the air conditioner so that front edge of the
bottom mounting rail is against the back edge of the sill.
B. Bring the window down so that the front edge of the top mounting is in
front of the window. Make sure that the air conditioner is level or tilting
slightly to the outside.
C. Extend the curtain panels until they fill the window. Mark the location of
the holes in each corner. Use the drill and 1/8* drill bit to drill pilot
holes. Use 4 type B screws to secure the side panels in place.
5. SECURE AIR CONDITIONER
A. Loosen the screw on the right hand side of the air conditioner near the
bottom.
B. Slide a side bracket over the screw so that the bracket is resting on the
window sill. Tighten the screw.
C. Use a 1/8 drill bit to drill a starter hole into the window sil through the
holes in the side bracket. Use 4 type B screws to attach the side bracket to
the window sill.
D. Repeat the side bracket installation on the left side.
E. Measure and cut adhesive foam backed sheet. Apply over side curtain and
frame.
6. INSTALL WINDOW LOCK BRACKET AND FOAM TOP WINDOW GASKET Use Type B Screw to
install the window lock bracket on top of the bottom window.
A. CAUTION
To prevent broken glass or damage to windows, on vinyl or other similarly
constructed windows, attach the window locking bracket to the window side jamb
with one Type B screw.
B. Cut the foam top window gasket to the window width.
C. Stuff the foam between the glass and the window to prevent air and insects from getting into the room.
NOTE: If the gasket supplied does not fit your window, obtain appropriate material locally to provide a proper installation seal.
Troubleshooting Tips… Before you call for service
Save time and money! Review the charts on the following pages first and you may not need to call for service.
Problem | Possible Cause | What To Do |
---|---|---|
Air conditionerdoes not start. | The unit is unplugged. | Make sure |
the air conditioner plug is pushed completely into the outlet.
The fuse is blown/circuit breaker is tripped.| &KHFN WKH KRXVH
IXVH/FiUFXiW EUHDNHU ER[ DQG UHSODFH
the fuse or reset the breaker.
Power Failure.| The unit will automatically restart in the setting last
used after the power is restored. There is a protective time delay
(approximately 3 minutes) to prevent tripping of the compressor overload. For
this reason, the unit may not start normal cooling for 3 minutes after it is
turned back on.
The current interrupter device is tripped.| Press RESET button located
on the power cord plug. If the RESET button will not stay engaged, discontinue
use of the air conditioner and contact a qualified service technician.
Air conditioner does not cool as it should.| Indoor airflow is
restricted.| Make sure there are not curtains, blinds or furniture blocking
the front of the air conditioner.
The temp control may not be set properly.| Turn the temperature control
to a higher number.
The air filter is dirty.| Clean the filter at least every 30 days. See
Care and Cleaning section.
The room may have been hot.| When the air conditioner is first turned
on, you need to allow time for the room to cool down.
Cold air is escaping.| Check for open furnace registers and cold air
returns.
Cooling coils have iced up.| 6HH ³$iU FRQGiWiRQHU IUHH]iQJ XS´ EHORZ.
Air conditioner freezing up| Ice blocks the air flow and stops the air
conditioner from cooling the room.| Set the mode control to High Fan or
High Cool with the temperature setting as high as it can be set.
Water drips outside| Hot, humid weather.| This is normal.
Water drips inside| The air conditioner is not tilted to the
outside.| For proper disposal, make sure the air conditioner slants
slightly from the case front to the rear.
Water collects in base pan| Moisture removed from air and drain into
base pan.| This is normal for a short period in areas with little humidity;
normal for a longer period in very humid areas.
Normal Operating Sounds
■ You may hear a pinging noise caused by water being picked up and thrown
against the condenser on rainy days or when the humidity is high. This design
feature helps remove moisture and improve efficiency.
■ You may hear the thermostat dick when the compressor cycles on and off.
■ Water will collect in the base pan duringhigh humidity or on rainy days. The
water may overflow and drip from the outdoor sideof the unit.
■ The fan may run even when the compressor does not.
■ Water droplets being thrown against the outside cols can make a pinging
noise. This helps cool the condenser. You can reduce this noise by removing
the subbase water plug.
To ensure maximum efficiency it is recommended to check to ensure the rubber
drain plug is properly inserted. This plug may be removed during operation to
minimize water in the back of the unit; however, removing it will lower the
efficiency of your unit.
NOTE: Do not drill hole in the base pan.
WiFi Setup
GE Appliances WiFi Connect (for customers in the United States)
GE Appliances WiFi Connect Enabled’. it your Air Conditioner (AC) has a
Connected Appliance Information label located on the outside as shown below,
your AC is GE Appliances WiFi Connect Enabled. A WiFi communication card is
built into the product allowing it to communicate with your smart phone for
remote monitoring, control and notifications. Please visit
www.GEAppliances.comlconnect to learn more about connected appliance features,
and to learn what connected appliance apps will work with your smart phone.
WiFi Connectivity: For assistance with the app ante or the ConnectPlus network connectivity (for models that are WiFi enabled or WiFi optional), please call 1-800-220-6899.
How it Works Download the GE Appliances App
Use the app to conned your room air conditioner to WiFi
Once connected, use the app to turn conditioner to WiFi down your air conditioner as you leave work.
Getting Started
To connect your room air conditioner, you’ll need the GE Appliances App. The
app will walk you through the connection process. Download the app from Tunes
or Google Play.
All connected appliace data is held in strict accordance with the GE
Appliances Connected Data Privacy Policy. Visit
geappliances.com/privacy/privacypolicy connected to view this policy.
Questions about WiFi Connect
Get answers you need about setting up WiFi appliances and connecting to your
home network in our support articles.
Visit products.geappliances.corniappliance/gea-support-search-content to view
wifi connect room air conditioner support articles.
REGULATORY INFORMATION
FCC/IC Compliance Statement:
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/television technician for help.
Labelling: Changes or modifications to this unit not expressly approved by the manufacturer could void the user’s authority to operate the equipment. ‘Select Models Only This product has Wi-Fi capability and requires Internet connectivity and a wireless router to enable interconnection with an Energy Management System, and/or with other external devices, systems or applications. Use of the Works with Apple HomeKitTo logo means that an electronic accessory has been designed to connect specifically to iPod touch®, iPhone0, or iPadO, respectively, and has been certified by the developer to meet Apple® performance standards. Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards.
In Order to Make a Warranty Claim During Your Retailer’s Allowable Return Period :
■ Property pack your unit. We recommend using the original carton and packing
materials.
■ Return the product to the retail location where it was purchased.
■ Include in the package a copy of the sales receipt or other evidence of date
of original purchase. Also print your name and address and a description of
the defect.
In Order to Make a Warranty Claim During the Remainder of the One-Year
Warranty:
■ Locate your original sales receipt and make a note of your model and serial
number.
■ Cal 1-800-GE-CARES (1-800-432-2737)
to initiate the product replacement process.
■ You will be asked to provide your name, address, date of purchase, model and
serial number.
■ GE Appliances will arrange for a carton to be sent to your home to recover
the product.
■ Please return all requested materials (postage pre-paid) in the carton
provided. Please include a description of the defect
■ You should receive your replacement product or refund within 7 to 10
business days after your package is received.
What Will Not Cover:
■ Customer instruction. This owner’s manual provides information regarding
operating instructions and user controls.
■ Improper Installation. V you have an Installation problem, or if the air
conditioner is of improper capacity, contact your dealer or installer. You are
responsible for providing adequate electrical connecting facilities.
■ Failure of the product resulting from modifications to the product or due to
unreasonable use including failure to provide reasonable and necessary
maintenance.
■ Replacement of house fuses or resetting of circuit breakers.
■ Falure due to corrosion on models not corrosion-protected.
■ Damage to the product caused by Improper power supply voltage, accident,
fire, floods or acts of God.
■ Inddental or consequential damage caused by possible defects with this air
conditioner.
■ Damage caused after delivery.
EXCLUSION OF IMPLIED WARRANTIES – Your sole and exclusive remedy is
product repair as provided in this Limited Warranty. Any implied warranties,
including the implied warranties of merchantability or fitness for a
particular purpose, are limited to one year or the shortest period allowed by
law. This limited warranty is extended to the original purchaser and any
succeeding owner for products purchased for home use within the USA. If the
product is located in an area where service by a GE Appliances Authorized
Servicer is not available, you may be responsible for a trip charge or you may
be required to bring the product to an Authorized GE Appliances Service
location for service. In Alaska, the limited warranty excludes the cost of
shipping or service calls to your home. Some states do not allow the exclusion
or limitation of incidental or consequential damages. This limited warranty
gives you specific legal tights, and you may also have other rights which vary
from state to state. To know what your legal rights are, consult your local or
state consumer affairs office or your state’s Attorney General.
Warrantor: GE Appliances, a Haier company Louisville. KY 40225
Consumer Support
GE Appliances Website Have a question or need assistance with your
appliance? Try the GE Appliances Website 24 hours a day, any day of the year!
You can also shop for more great GE Appliances products and take advantage of
all our on-line support services designed for your convenience.
GEAppliances.com
Register Your Appliance Register your new appliance on-line at your
convenience! Timely product registration will allow for enhanced communication
and prompt service under the temis of your warranty, should the need arise.
You may also mail in the pre-printed registration card included in the packing
material. GEAppliances.com/register
Parts and Accessories Individuals qualified to service their own
appliances can have parts or accessories sent directly to their homes (VISA
MasterCard and Discover cards are accepted). Order on-line today 24 hours
every day. GEApplianceparts.com or by phone at 877.959.8688 during normal
business hours. Instructions contained in this manual cover procedures to be
performed by any user. Other servicing generally should be referred to
qualified service personnel. Caution must be exercised, since improper
servicing may cause unsafe operation.
Contact Us If you are not satisfied with the service you receive from GE
Appliances, contact us on our Website with all the details including your
phone number, or write to: General Manager, Customer Relations I GE
Appliances, Appliance Park I Louisville, KY 40225 GEAppliances.com/ge
/service-and-supporticontact.htm
Read More About This Manual & Download PDF:
References
- Appliance Parts, Accessories & Water Filters | GE Appliances
- Contact Us or Get Help with Questions | GE Appliances
- GEAppliances.com/register
- Connect Your Smart Appliances
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>