ATSUMI Smart Lock ZSL10 Instruction Manual
- June 7, 2024
- ATSUMI
Table of Contents
Smart Lock
ZSL10
Instruction Manual
Introduction
This document describes the Smart Lock overview and how to use the Z-WaveTM
functionality.
This product “ZSL10” can remotely lock and unlock the door and check the
status by remote control.
This device is a security-enabled Z-Wave Plus ™ product that is able to use encrypted Z-Wave Plus™ messages to communicate to other security-enabled Z- ave Plus™ products.
This device must be used in conjunction with a S2 Security Enabled Z-Wave™
Controller in order to fully utilize all implemented functions.
This product can be operated in any Z-WaveTM network with other Z-WaveTM
certified devices from other manufacturers.
All non-battery-operated nodes within the network will act as repeaters
regardless of vendor to increase the reliability of the network.
SmartStart enabled products can be added into a Z-WaveTM network by scanning
the Z-WaveTM QR Code present on the product with a controller providing
SmartStart inclusion. No further action is required and the SmartStart product
will be added automatically within 10 minutes of being switched on in the
network vicinity.
QR code and Full DSK is located inside the battery box of IN BODY and on the packing box.
Part Names
IN – BODY
(1) Battery cover
(2) O/C Button
(3) Battery holder
(4) EX Button
(5) SET Button
(6) Battery box
(7) QR code and Full DSK
OUT – BODY
Operation
1. Insert batteries
Remove the battery cover of INBODY.
Install AA batteries in the battery case. 4*AA(Alkaline or lithium)
Wait for a while, a beep will sound and the o/c button will blink blue.
When the blinking goes off, the startup is complete.
2-1. Add (Inclusion) – SmartStart
Add the smart lock DSK into the primary controller SmartStart
Provisioning List.
(If your controller does not support SmartStart inclusion, please refer to the
manual for your controller for non-SmartStart inclusion.)
2-2. Add – Normal Inclusion
Set the controller in “Add(Inclusion)” mode.
For the operation procedure, see the instruction manual of the controller.
Press the SET button for about 5 seconds to start the registration operation
and the O / C button will blink blue and beeps twice.
Inclusion takes about 1 minute. Please confirm the inclusion is complete.
After that, it flashes red, but this is not related to the success/failure of
inclusion.
3. Remove (Exclusion)
Set the controller in “Remove(Exclusion)” mode.
For the operation procedure, see the instruction manual of the controller.
Press the SET button for about 5 seconds to start the registration operation
and the O / C button will blink blue and beeps twice.
Please confirm the inclusion is complete.
After that, it flashes red, but this is not related to the success/failure of
inclusion.
4. Factory Default Reset
[ NOTE ] Use this procedure only in the event that the primary controller is
lost.
The controller information are cleared.
The lock settings and user information do not change.
Press the SET button three times in two seconds to start the reset operation
and the O/C button will blink red and beeps.
Command Class
Battery (0x80)
The device sends the battery capacity in %.
It Sends “0xFF” when the voltage goes below the threshold.
Basic (0x20)
Basic CC is maps to Door Lock CC.
0x00 : Door Unsecured
0xFF : Door Secured
Association (0x85)
The number of supported groups is 1. ”Lifeline”
The number of supportable nodes is 1 unit.
User Code (0x63)
This command allows user registration and deletion, and user information
acquisition.
PIN code that duplicates another user cannot be used.
Registration, PIN code change (0x01)
7| 6| 5| 4| 3| 2| 1|
0
---|---|---|---|---|---|---|---
Command Class = COMMAND CLASS_USER_CODE
Command = USER CODE_SET
User Identifier
User ID Status
User Code 1
…
User Code N
User Identifier
0x01~0x63
User ID Status
0x01
User Code
1~9(UTF-8) N:4~8
Deletion (0x01)
7| 6| 5| 4| 3| 2| 1|
0
---|---|---|---|---|---|---|---
Command Class = COMMAND_CLASS_USER_CODE
Command = USER_CODE_SET
User Identifier
User ID Status
User Identifier
0x01~0x63
User ID Status
0x00
Get user ID list (0x0C)
7| 6| 5| 4| 3| 2| 1|
0
---|---|---|---|---|---|---|---
Command Class = COMMAND_CLASS_USER_CODE
Command = EXTENDED USER_CODE_GET
User Identifier 1 (MSB)
User Identifier 2 (LSB)
Reserved
|
Report more
User Identifier 1 (MSB)
0x00
User Identifier 1 (LSB)
0x01~0x63
Report more
0:Only User Identifier
1:All after User Identifier
Response (0x0D)
7| 6| 5| 4| 3| 2| 1|
0
---|---|---|---|---|---|---|---
Command Class = COMMAND CLASS USER CODE
Command = EXTENDED_USER_CODE_REPORT
Number of User Codes
User Identifier 1 (MSB) 1
User Identifier 2 (LSB) 1
User ID Status 1
Reserved
|
User Code Length 1
User Code 1, 1
………
User Code N, 1
User Identifier 1 (MSB) M
User Identifier 2 (LSB) M
User ID Status M
Reserved|
User Code Length M
User Code 1, M
……
User Code N, M
Next User Identifier 1 (MSB)
Next User Identifier 2 (LSB)
Number of User Codes
Number of response
User Identifier N (MSB)
0x01
User Identifier N (LSB)
0x01~0x63
User ID Status
0x00:User ID does not exist
0x01:User ID exists
0xFE: No users
User Code Length
4~8:PIN Code Length
User Code
1~9(UTF-8) N:4~8
Next User Identifier
0x00:End of response
0x01~0x63:Next User ID
Get user PIN Code (0x02)
Get user PIN Code (0x02)
Get user PIN Code (0x02)
7| 6| 5| 4| 3| 2| 1|
0
---|---|---|---|---|---|---|---
Command Class = COMMAND_CLASS_USER_CODE
Command = USER_CODE_GET
User Identifier
User Identifier
0x01~0x63
Response (0x03)
7| 6| 5| 4| 3| 2| 1|
0
---|---|---|---|---|---|---|---
Command Class = COMMAND_CLASS_USER_CODE
Command = USER_CODE_REPORT
User Identifier
User ID Status
User Code 1
…
User Code N
User Identier
0x01~0x63
User ID Status
0x00:User ID does not exist
0x01:User ID exists
0xFE: Master ID does
not exist
User Code
1~9(UTF-8) N:4~8
0x00:If User ID Status is
“0x00” or “0xFE”
Door Lock Logging (0x4C)
Get event type (0x03)
7| 6| 5| 4| 3| 2| 1|
0
---|---|---|---|---|---|---|---
Command Class = COMMAND CLASS DOOR LOCK LOGGING
Command = RECORD GET
Record number
Record number
0x00~0x06
The record number log once got will be deleted. To get the log for the next
queue, get the log for all record numbers.
Response (0x04)
7| 6| 5| 4| 3| 2| 1|
0
---|---|---|---|---|---|---|---
Command Class = COMMAND CLASS DOOR LOCK LOGGING
Command = RECORD REPORT
Record number
Timestamp – Year 1 (MSB)
Timestamp – Year 2 (LSB)
Timestamp — Month
Timestamp — Day
Record status
|
Timestamp – Hour Local Time
Timestamp – Minute Local Time
Timestamp – Second Local Time
Event Type
User Identifier
User Code Length
Record number
0x01~0x06
Timestamp – Year 1 (MSB)
Timestamp – Year 2 (LSB)
Timestamp – Month
Timestamp – Day
Record status
0x01
Timestamp – Hour Local Time
Timestamp – Minute Local Time
Timestamp – Second Local Time
Event Type (See Table 1)
User Identifier
0x00~0x63
User Code Length
0x00
Table 1. Event Type
Value | Event type |
---|---|
Ox01 | Lock Command: Keypad access code verified lock command |
0x02 | Unlock Command: Keypad access code verified unlock command |
0x03 | Lock Command: Keypad lock button pressed |
0x04 | Unlock command: Keypad unlock button pressed |
0x07 | Keypad illegal access code entered |
0x08 | Key or latch operation locked (manual) |
Ox09 | Key or latch operation unlocked (manual) |
OxOA | Auto lock operation |
OxOB | Auto unlock operation |
OxOE | Lock Command: Z-Wave (no code) |
OxOF | Unlock Command: Z-Wave (no code) |
0x17 | User code added |
0x18 | User code deleted |
Ox1B | User code changed |
Ox1C | Lock reset |
OxlE | Low battery |
Door Lock (0x62)
Get Lock state (0x02)
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
---|
Command Class = COMMAND_CLASS_DOOR_LOCK
Command = DOOR_LOCK_OPERATION_GET
Response (0x03)
7| 6| 5| 4| 3| 2| 1|
0
---|---|---|---|---|---|---|---
Command Class = COMMAND_CLASS_DOOR_LOCK
Command = DOOR_LOCK_OPERATION_REPORT
Door Lock Mode
Outside Door Handles Mode
|
Inside Door Handles Mode
Door Condition
Lock Timeout Minutes
Lock Timeout Seconds
Target Door Lock Mode
Duration
Door Lock Mode
0x00 : Door Unsecured
0xFF : Door Secured
Outside Door Handles Mode
0x00
Inside Door Handles Mode
0x00
Door Condition
| Door| Lock
---|---|---
Ox00
| secured| unsecured
Ox01
| secured|
secured
0x02| unsecured|
unsecured
0x03| unsecured|
secured
Lock Timeout Minutes
0x00
Lock Timeout Seconds
0x00
Target Door Lock Mode
0x00
Duration
0x00
Remote control (0x01)
7| 6| 5| 4| 3| 2| 1|
0
---|---|---|---|---|---|---|---
Command Class = COMMAND_CLASS_DOOR_LOCK
Command = DOOR_LOCK_OPERATION_SET
Door Lock Mode
Door Lock Mode
0x00 : Door Unsecured
0xFF : Door Secured
Response (0x03)
7| 6| 5| 4| 3| 2| 1|
0
---|---|---|---|---|---|---|---
Command Class = COMMAND_CLASS_DOOR_LOCK
Command = DOOR_LOCK_OPERATION_REPORT
Door Lock Mode
Outside Door Handles Mode
|
Inside Door Handles Mode
Door Condition
Lock Timeout Minutes
Lock Timeout Seconds
Target Door Lock Mode
Duration
Door Lock Mode
0x00 : Door Unsecured
0xFF : Door Secured
Outside Door Handles Mode
0x00
Inside Door Handles Mode
0x00
Door Condition
0x00
Lock Timeout Minutes
0x00
Lock Timeout Seconds
0x00
Target Door Lock Mode
0x00
Duration
0x0 0
Indicator (0x87)
When you send this command, it beeps once and the button fiashes blue about 2
second.
7| 6| 5| 4| 3| 2| 1|
0
---|---|---|---|---|---|---|---
Command Class = COMMAND_CLASS_INDICATOR
Command = INDICATOR_SET
Value
Value 0xFF
Firmware-Update over the Air (0x7A)
This device is capable of receiving a new rmware ‘over the air’.
Target 0 : Z-Wave
Target 1 : INBODY
Target 2 : OUTBODY
Configuration
Configuration Parameters
Parameter No.13
Change the device time setting.
Default : 0 [NOTE] If Default is set to 1, the following items will ignore the
set values and return to the defaults.
Size : 4
Configuration_Set(0x04)
7| 6| 5| 4| 3| 2| 1|
0
---|---|---|---|---|---|---|---
Command Class = COMMAND_CLASS_CONFIGURATION
Command = CONFIGURATION SET
Parameter Number
Default
| Reserved|
Size
Device time(MSB)
…
…
Device time(LSB)
Default
0x38
0x6D
0x43
0x80
Configurable time 2000/01/01 00:00:00 ~ 2099/12/31 23:59:59
[NOTE] It cannot be set at any other time.
Configuration_Report(0x06)
The format after the parameter number is the same as SET.
Parameter No.14
Change the lock settings.
Default : 0 [NOTE]If Default is set to 1, the following items will ignore the
set values and return to the defaults.
Size : 2
Configuration_Set(0x04)
7 | I 6 | 5 | 4 I | 3 | I 2 | I 1 | I 0 |
---|
Command Class = COMMAND CLASS CONFIGURATION
Command = CONFIGURATION SET
Parameter Number
Default| Reserved| Size
Setting the han in g g| Volume| Lock mode| 0/C button| Main/sub switching for
double lock| 0
Door sensor| Lock mode when unlocking thumb turn| Moter
torque
| 0| 0| 0| 0
Configuration_Report(0x06)
The format after the parameter number is the same as SET.
Pn14 Setting details
Setting name | Value | Detail | Default |
---|---|---|---|
Setting the hanging | 0 |
left hanging door
| |
1| right hanging door| 0
Volume| 00| mute|
01| small|
10| medium| 0
11| large|
Lock mode| 00| automatic locking – short| 0
01| automatic locking – long|
10| manual|
11| manual 1|
0/C button| 0| disable|
1| enabled| 0
Main/sub switching for double lock| 0| main| 0
1| sub 2,3|
Door sensor| 00| disable|
01| enabled| 0
10| enabled 4|
11| Not used|
Lock mode when unlocking thumb turn| 0| Continuous-unlocking| 0
1| automatic locking *5|
Motor torque| 0| normal| 0
1| high|
1 When locking with OUTBODY, operation with PIN code or IC card is required.
2 The lock mode changes to manual (0x02).
3 The door sensor changes to disable (0x00).
4 No alarm when the door is forced open.
*5 If the lock mode is manual, it cannot be set to (0x01).
Z-Wave Command Classes
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_TRANSPORT_SERVICE_V2
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SECURITY_2
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_ASSOCIATION_V2(On Secure)
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3(On Secure)
COMMAND_CLASS_BASIC_V2(On Secure)
COMMAND_CLASS_BATTERY(On Secure)
COMMAND_CLASS_CONFIGURATION(On Secure)
COMMAND_CLASS_DEVICE_RESET_LOCALLY(On Secure)
COMMAND_CLASS_DOOR_LOCK_V4(On Secure)
COMMAND_CLASS_DOOR_LOCK_LOGGING(On Secure)
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5(On Secure)
COMMAND_CLASS_INDICATOR_V3(On Secure)
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2(On Secure)
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3(On Secure)
COMMAND_CLASS_POWERLEVEL(On Secure)
COMMAND_CLASS_USER_CODE(On Secure)
COMMAND_CLASS_VERSION_V3(On Secure)
Specifications
Product name | Smart Lock |
---|---|
Part number | ZSL10 |
Power supply | AA type x 4 |
Indicating light | Red and blue (IN – BODY) |
White , red , green (OUT – BODY)
Operating temperature| For alkaline batteries 0 to +50 °C
For lithium batteries -20 to +50 °C
Operating humidity| RH 20 to 85% (no condensation)
Communication mode| Z-Wave®
Available frequency| 922.5 / 923.9 / 926.3 MHz
Communication distance| About 30 m (prospect)
Outside dimensions
IN – BODY
| About 74.8(W) x 129.3(H) x 54.5(D) mm
OUT – BODY| About 56.9(W) x 93.4(H) x 17.98(D) mm
Mass| About 800 g
Read User Manual Online (PDF format)