ATSUMI Smart Lock ZSL10 Instruction Manual

June 7, 2024
ATSUMI

ATSUMI Smart Lock ZSL10 -- logo
Smart Lock
ZSL10

Instruction Manual

Introduction

This document describes the Smart Lock overview and how to use the Z-WaveTM functionality.
This product “ZSL10” can remotely lock and unlock the door and check the status by remote control.

This device is a security-enabled Z-Wave Plus ™ product that is able to use encrypted Z-Wave Plus™ messages to communicate to other security-enabled Z- ave Plus™ products.

This device must be used in conjunction with a S2 Security Enabled Z-Wave™ Controller in order to fully utilize all implemented functions.
This product can be operated in any Z-WaveTM network with other Z-WaveTM certified devices from other manufacturers.
All non-battery-operated nodes within the network will act as repeaters regardless of vendor to increase the reliability of the network.
SmartStart enabled products can be added into a Z-WaveTM network by scanning the Z-WaveTM QR Code present on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity.

QR code and Full DSK is located inside the battery box of IN BODY and on the packing box.

Part Names

IN – BODY
ATSUMI Smart Lock ZSL10 -- IN - BODY

(1) Battery cover
(2) O/C Button
(3) Battery holder
(4) EX Button
(5) SET Button
(6) Battery box
(7) QR code and Full DSK

OUT – BODY

ATSUMI Smart Lock ZSL10 -- OUT - BODY Operation

1. Insert batteries
Remove the battery cover of INBODY.
Install AA batteries in the battery case. 4*AA(Alkaline or lithium)
Wait for a while, a beep will sound and the o/c button will blink blue.
When the blinking goes off, the startup is complete.

ATSUMI Smart Lock ZSL10 -- OUT - Operation

2-1. Add (Inclusion) – SmartStart
Add the smart lock DSK into the primary controller SmartStart
Provisioning List.
(If your controller does not support SmartStart inclusion, please refer to the manual for your controller for non-SmartStart inclusion.)

2-2. Add – Normal Inclusion
Set the controller in “Add(Inclusion)” mode.
For the operation procedure, see the instruction manual of the controller.
Press the SET button for about 5 seconds to start the registration operation and the O / C button will blink blue and beeps twice.
Inclusion takes about 1 minute. Please confirm the inclusion is complete.
After that, it flashes red, but this is not related to the success/failure of inclusion.

ATSUMI Smart Lock ZSL10 -- Remove \(Exclusion\)

3. Remove (Exclusion)
Set the controller in “Remove(Exclusion)” mode.
For the operation procedure, see the instruction manual of the controller.
Press the SET button for about 5 seconds to start the registration operation and the O / C button will blink blue and beeps twice.
Please confirm the inclusion is complete.
After that, it flashes red, but this is not related to the success/failure of inclusion.

ATSUMI Smart Lock ZSL10 -- Remove \(Exclusion\)

4. Factory Default Reset
[ NOTE ] Use this procedure only in the event that the primary controller is lost.
The controller information are cleared.
The lock settings and user information do not change.
Press the SET button three times in two seconds to start the reset operation and the O/C button will blink red and beeps.

ATSUMI Smart Lock ZSL10 -- Factory Default Reset

Command Class

Battery (0x80)
The device sends the battery capacity in %.
It Sends “0xFF” when the voltage goes below the threshold.
Basic (0x20)
Basic CC is maps to Door Lock CC.
0x00 : Door Unsecured
0xFF : Door Secured
Association (0x85)
The number of supported groups is 1. ”Lifeline”
The number of supportable nodes is 1 unit.
User Code (0x63)
This command allows user registration and deletion, and user information acquisition.
PIN code that duplicates another user cannot be used.

Registration, PIN code change (0x01)

7| 6| 5| 4| 3| 2|  1|

0

---|---|---|---|---|---|---|---

Command Class = COMMAND CLASS_USER_CODE

Command = USER CODE_SET

User Identifier

User ID Status

User Code 1

User Code N

User Identifier
0x01~0x63
User ID Status
0x01
User Code
1~9(UTF-8) N:4~8

Deletion (0x01)

7| 6| 5| 4| 3| 2| 1|

0

---|---|---|---|---|---|---|---

Command Class = COMMAND_CLASS_USER_CODE

Command = USER_CODE_SET

User Identifier

User ID Status

User Identifier
0x01~0x63
User ID Status
0x00

Get user ID list (0x0C)

7| 6| 5| 4| 3| 2| 1|

0

---|---|---|---|---|---|---|---

Command Class = COMMAND_CLASS_USER_CODE

Command = EXTENDED USER_CODE_GET

User Identifier 1 (MSB)

User Identifier 2 (LSB)

Reserved

|

Report more

User Identifier 1 (MSB)
0x00
User Identifier 1 (LSB)
0x01~0x63
Report more
0:Only User Identifier
1:All after User Identifier
Response (0x0D)

7| 6| 5| 4| 3| 2| 1|

0

---|---|---|---|---|---|---|---

Command Class = COMMAND CLASS USER CODE

Command = EXTENDED_USER_CODE_REPORT

Number of User Codes

User Identifier 1 (MSB) 1

User Identifier 2 (LSB) 1

User ID Status 1

Reserved

|

User Code Length 1

User Code 1, 1

………

User Code N, 1

User Identifier 1 (MSB) M


User Identifier 2 (LSB) M

User ID Status M

Reserved|

User Code Length M

User Code 1, M

……

User Code N, M

Next User Identifier 1 (MSB)

Next User Identifier 2 (LSB)

Number of User Codes
Number of response
User Identifier N (MSB)
0x01
User Identifier N (LSB)
0x01~0x63
User ID Status
0x00:User ID does not exist
0x01:User ID exists
0xFE: No users
User Code Length
4~8:PIN Code Length
User Code
1~9(UTF-8) N:4~8
Next User Identifier
0x00:End of response
0x01~0x63:Next User ID
Get user PIN Code (0x02)

Get user PIN Code (0x02)

Get user PIN Code (0x02)

7| 6| 5| 4| 3| 2| 1|

0

---|---|---|---|---|---|---|---

Command Class = COMMAND_CLASS_USER_CODE

Command = USER_CODE_GET

User Identifier

User Identifier
0x01~0x63

Response (0x03)

7| 6| 5| 4| 3| 2| 1|

0

---|---|---|---|---|---|---|---

Command Class = COMMAND_CLASS_USER_CODE

Command = USER_CODE_REPORT

User Identifier

User ID Status

User Code 1

User Code N

User Identier
0x01~0x63
User ID Status
0x00:User ID does not exist
0x01:User ID exists
0xFE: Master ID does
not exist
User Code
1~9(UTF-8) N:4~8
0x00:If User ID Status is
“0x00” or “0xFE”

Door Lock Logging (0x4C)
Get event type (0x03)

7| 6| 5| 4| 3| 2| 1|

0

---|---|---|---|---|---|---|---

Command Class = COMMAND CLASS DOOR LOCK LOGGING

Command = RECORD GET

Record number

Record number
0x00~0x06
The record number log once got will be deleted. To get the log for the next queue, get the log for all record numbers.
Response (0x04)

7| 6| 5| 4| 3| 2| 1|

0

---|---|---|---|---|---|---|---

Command Class = COMMAND CLASS DOOR LOCK LOGGING

Command = RECORD REPORT

Record number

Timestamp – Year 1 (MSB)

Timestamp – Year 2 (LSB)

Timestamp — Month

Timestamp — Day

Record status

|

Timestamp – Hour Local Time

Timestamp – Minute Local Time

Timestamp – Second Local Time

Event Type

User Identifier

User Code Length

Record number
0x01~0x06
Timestamp – Year 1 (MSB)
Timestamp – Year 2 (LSB)
Timestamp – Month
Timestamp – Day
Record status
0x01
Timestamp – Hour Local Time
Timestamp – Minute Local Time
Timestamp – Second Local Time
Event Type (See Table 1)
User Identifier
0x00~0x63
User Code Length
0x00

Table 1. Event Type

Value Event type
Ox01 Lock Command: Keypad access code verified lock command
0x02 Unlock Command: Keypad access code verified unlock command
0x03 Lock Command: Keypad lock button pressed
0x04 Unlock command: Keypad unlock button pressed
0x07 Keypad illegal access code entered
0x08 Key or latch operation locked (manual)
Ox09 Key or latch operation unlocked (manual)
OxOA Auto lock operation
OxOB Auto unlock operation
OxOE Lock Command: Z-Wave (no code)
OxOF Unlock Command: Z-Wave (no code)
0x17 User code added
0x18 User code deleted
Ox1B User code changed
Ox1C Lock reset
OxlE Low battery

Door Lock (0x62)
Get Lock state (0x02)

7 6 5 4 3 2 1 0

Command Class = COMMAND_CLASS_DOOR_LOCK
Command = DOOR_LOCK_OPERATION_GET

Response (0x03)

7| 6| 5| 4| 3| 2| 1|

0

---|---|---|---|---|---|---|---

Command Class = COMMAND_CLASS_DOOR_LOCK

Command = DOOR_LOCK_OPERATION_REPORT

Door Lock Mode

Outside Door Handles Mode

|

Inside Door Handles Mode

Door Condition

Lock Timeout Minutes

Lock Timeout Seconds

Target Door Lock Mode

Duration

Door Lock Mode
0x00 : Door Unsecured
0xFF : Door Secured
Outside Door Handles Mode
0x00
Inside Door Handles Mode
0x00
Door Condition

| Door| Lock
---|---|---

Ox00

| secured| unsecured

Ox01

| secured|

secured

0x02| unsecured|

unsecured

0x03| unsecured|

secured

Lock Timeout Minutes
0x00
Lock Timeout Seconds
0x00
Target Door Lock Mode
0x00
Duration
0x00

Remote control (0x01)

7| 6| 5| 4| 3| 2| 1|

0

---|---|---|---|---|---|---|---

Command Class = COMMAND_CLASS_DOOR_LOCK

Command = DOOR_LOCK_OPERATION_SET

Door Lock Mode

Door Lock Mode
0x00 : Door Unsecured
0xFF : Door Secured

Response (0x03)

7| 6| 5| 4| 3| 2| 1|

0

---|---|---|---|---|---|---|---

Command Class = COMMAND_CLASS_DOOR_LOCK

Command = DOOR_LOCK_OPERATION_REPORT

Door Lock Mode

Outside Door Handles Mode

|

Inside Door Handles Mode

Door Condition

Lock Timeout Minutes

Lock Timeout Seconds

Target Door Lock Mode

Duration

Door Lock Mode
0x00 : Door Unsecured
0xFF : Door Secured
Outside Door Handles Mode
0x00
Inside Door Handles Mode
0x00
Door Condition
0x00
Lock Timeout Minutes
0x00
Lock Timeout Seconds
0x00
Target Door Lock Mode
0x00
Duration
0x0 0

Indicator (0x87)
When you send this command, it beeps once and the button fiashes blue about 2 second.

7| 6| 5| 4| 3| 2| 1|

0

---|---|---|---|---|---|---|---

Command Class = COMMAND_CLASS_INDICATOR

Command = INDICATOR_SET

Value

Value 0xFF
Firmware-Update over the Air (0x7A)
This device is capable of receiving a new rmware ‘over the air’.
Target 0 : Z-Wave
Target 1 : INBODY
Target 2 : OUTBODY

Configuration

Configuration Parameters
Parameter No.13
Change the device time setting.
Default : 0 [NOTE] If Default is set to 1, the following items will ignore the set values and return to the defaults.

Size : 4
Configuration_Set(0x04)

7| 6| 5| 4| 3| 2| 1|

0

---|---|---|---|---|---|---|---

Command Class = COMMAND_CLASS_CONFIGURATION

Command = CONFIGURATION SET

Parameter Number

Default

| Reserved|

Size

Device time(MSB)

Device time(LSB)

Default
0x38
0x6D
0x43
0x80
Configurable time 2000/01/01 00:00:00 ~ 2099/12/31 23:59:59
[NOTE] It cannot be set at any other time.

Configuration_Report(0x06)
The format after the parameter number is the same as SET.
Parameter No.14
Change the lock settings.
Default : 0 [NOTE]If Default is set to 1, the following items will ignore the set values and return to the defaults.

Size : 2
Configuration_Set(0x04)

7 I     6 5 4         I 3 I     2 I       1 I     0

Command Class = COMMAND CLASS CONFIGURATION
Command = CONFIGURATION SET
Parameter Number
Default| Reserved| Size
Setting the han in g g| Volume| Lock mode| 0/C button| Main/sub switching for double lock| 0
Door sensor| Lock mode when unlocking thumb turn| Moter

torque

| 0| 0| 0| 0

Configuration_Report(0x06)
The format after the parameter number is the same as SET.

Pn14 Setting details

Setting name Value Detail Default
Setting the hanging 0

left hanging door

| |
1| right hanging door| 0
Volume| 00| mute|
01| small|
10| medium| 0
11| large|
Lock mode| 00| automatic locking – short| 0
01| automatic locking – long|
10| manual|
11| manual 1|
0/C button| 0| disable|
1| enabled| 0
Main/sub switching for double lock| 0| main| 0
1| sub
2,3|
Door sensor| 00| disable|
01| enabled| 0
10| enabled
4|
11| Not used|
Lock mode when unlocking thumb turn| 0| Continuous-unlocking| 0
1| automatic locking *5|
Motor torque| 0| normal| 0
1| high|

1 When locking with OUTBODY, operation with PIN code or IC card is required.
2 The lock mode changes to manual (0x02).
3 The door sensor changes to disable (0x00).
4 No alarm when the door is forced open.
*5 If the lock mode is manual, it cannot be set to (0x01).

Z-Wave Command Classes

COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_TRANSPORT_SERVICE_V2
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SECURITY_2
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_ASSOCIATION_V2(On Secure)
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3(On Secure)
COMMAND_CLASS_BASIC_V2(On Secure)
COMMAND_CLASS_BATTERY(On Secure)
COMMAND_CLASS_CONFIGURATION(On Secure)
COMMAND_CLASS_DEVICE_RESET_LOCALLY(On Secure)
COMMAND_CLASS_DOOR_LOCK_V4(On Secure)
COMMAND_CLASS_DOOR_LOCK_LOGGING(On Secure)
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5(On Secure)
COMMAND_CLASS_INDICATOR_V3(On Secure)
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2(On Secure)
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3(On Secure)
COMMAND_CLASS_POWERLEVEL(On Secure)
COMMAND_CLASS_USER_CODE(On Secure)
COMMAND_CLASS_VERSION_V3(On Secure)

Specifications

Product name Smart Lock
Part number ZSL10
Power supply AA type x 4
Indicating light Red and blue (IN – BODY)

White , red , green (OUT – BODY)

Operating temperature| For alkaline batteries 0 to +50 °C

For lithium batteries -20 to +50 °C

Operating humidity| RH 20 to 85% (no condensation)
Communication mode| Z-Wave®
Available frequency| 922.5 / 923.9 / 926.3 MHz
Communication distance| About 30 m (prospect)
Outside dimensions

IN – BODY

| About 74.8(W) x 129.3(H) x 54.5(D) mm
OUT – BODY| About 56.9(W) x 93.4(H) x 17.98(D) mm
Mass| About 800 g