BEFORE USE
The Medic Therapeutics Air Purifier can help you achieve a healthy and
comfortable living and working environment. Air purifiers are an effective,
safe way to eliminate the contaminants that create indoor air pollution.
Contaminants such as dust mites, pollen, harmful gases, second-hand smoke,
etc., can be dramatically reduced and even eliminated by the Ultraviolet (UVC)
lamp in the purifier. UVC light will eliminate DNA-based contagions such as
Mold Spores, Viruses, and Bacteria.
The air inlets on all four sides and the outlet structure on top of the unit
provide comprehensive and highly effective air circulation. Welcome to a
healthier living and working environment.
PRODUCT STRUCTURE
PREPARATION BEFORE USE
- Open the package, take out the main unit and filter, remove the packaging bag, rotate the filter according to the direction of the logo, and tighten the filter clip.
- In order to better utilize the performance of the air purifier, the main air inlet should keep a certain distance from the obstruction, it is recommended to be more than 15cm.
- Remove the power adapter and connect the power supply to the purifier socket. After power on, it will sound “drop” and the ON/OFF button is light.
OPERATION PANEL AND FUNCTION
- Control panel
| Power ON/OFF
---|---
| Timing adjustment: 1H-2H-3H-4H-5H-6H-7H-8H
| Fan speed adjustment: “Low-Mid-High-Sleep-Auto”
| The filter replacement reminder and reset
2. Standby
Insert the plug of the air purifier into a power source, the buzzer will
ring, “power button” indicator lights up.
-
Power On/Off
Tap the top power icon to switch the power on/off. The default fan speed will operate on Low mode, and the negative ion and UVC lamp will be working. -
PM2.5 Display
The air quality sensor automatically starts working after the power is turned on. Wait 3 minutes for the sensor to stabilize. (Note: the value indicated in this function is for reference only and cannot be used to replace professional testing equipment). -
Fan Speed button
Fan speed adjustment “Low”→ “Mid” → “High”→ “Sleep”→ “AUTO”, Loop in turn. -
Timing Function
Touch the timing icon adjust the countdown shutdown time 1H-2H-3H-4H-5H-6H-7H- 8H Loop in turn. -
Replace the filter
When the air purifier is turned on, it will countdown, then the air purifier will turn off and back on. It will then continue to countdown. When the filter in place has been in use for 3000 hours, the replacement filter indicator light will flash, and the buzzer will beep. Replace the old filter with the new one, and then press the filter reset icon for three seconds; the icon will light up and stay lit.
INSTRUCTIONS
Before you turn on the machine for the first time, be sure to remove the filter bag before you use it.
-
Air purifier filter installation
Grasp the bottom cover handle by hand (the position shown in the picture) and turn the bottom cover in the direction of unlocking. Then take out the filter, remove the filter bag, and put the filters back, then insert the bottom cover into the fuselage and turn it in the direction of the lock.
-
Air Quality Indicator
Air Quality| Good| Lightly Polluted
Heavily| Polluted
---|---|---|---
Fan Speed| Low| Mid| High
PM2.5| 0-50| 51-149| >150
3. The Sleep Mode
The lights of the other icons on the sensor panel are off, and the purifier
will automatically set itself to the low fan speed .
- Filter Replacement (After 8-12 Months of Use)
1. Make sure the air purifier is unplugged before opening the filter cover at the bottom.
2. Open the filter cover by turning it counter-clockwise.
3. After replacing the filter, lock the filter cover by turning it clockwise.
MAINTENANCE
Be sure to unplug the power adapter before performing any maintenance.
- Clean the filter once a month. The surface of the filter should only be cleaned with a brush or a dry cotton cloth. Do not wash the filter with water or detergent. The filter can easily break or become deformed. Do not press hard when cleaning. If the filter gets damaged, make sure to replace it with a new one.
- Replace the filter once every 8-12 months. Depending on the place and the method of use, such as heavily polluted areas, smoking by family members, etc., the filter replacement cycle may be shortened. Please replace the filter in time when the filtering effect is no longer effective.
- Outer surface cleaning: Wipe the outer surface and air inlet and outlet with a soft cloth. Do not use a chemical cleaner.
- If left idle for a long period of time, make sure to unplug the power adapter, clean the outer surface and the filter. Cover the air purifier with a plastic bag and store it in a room with low moisture levels.
PRODUCT SPECIFICATIONS
Product Name: | Air Purifier |
---|---|
Product Size: | 208x208x323mm |
P acking Size: | 246×246 x405mm |
Product Weight: | 1.8KG |
HEPA Filter: | H13 level |
Application Area: | 525m2 |
UVC type: | Cold Cathode UVC tube |
Negative ions: | Millions/cm3 |
--- | --- |
Adapter Voltage: | 100-240V 50/60Hz |
Rated Voltage: | 24V DC |
Rated Power: | 22W |
CADR Particles | 150(m3/h) |
Noise: | .55 dB(A) |
Product NO: | MT-AIRPURIF-001 |
PRECAUTIONS
- Do not use liquid to clean or spill this product.
- There is a high-speed wind wheel in the purifier. Do not put your hands or foreign objects into the air inlet and outlet.
- Place the purifier as far as possible out of reach of children. Do not give this product to children.
- Do not put your hair, fabric, etc. close to the main unit to avoid getting in or blocking the air inlet and outlet blocking the air inlet and outlet.
- In order to improve the purification effect, try to close the doors and windows when using the product.
- Do not use power adapters of different specifications. Please install the power adapter supplied with this product.
- Do not use this purifier in the bathroom or other places with high temperature, humidity and water.
TROUBLESHOOTING
Phenomenon | Possible Reasons and Solutions |
---|---|
The filter is too dirty and has not been replaced for a long time replace |
the filter.
| The filter is flooded or used in a wet environment to replace filter.
Odor| Reuse after a period of storage clean the filter, if not, replace
the filter.
| If there is a burnt smell immediately stop using, unplug the power supply,
contact repair.
No wind at the outlet| The motor is not running check if the power
supply is normal, replace the power adaptor, or contact repair.
No effect| Filter failure replaces the filter.
| Used in inappropriate places (large area).
LIMITED LIFETIME WARRANTY
Your Medic Therapeutics Air Purifier is backed by a limited lifetime
manufacturer’s warranty. Medic Therapeutics will repair or replace your device
at any time should it fail due to a defect in material or workmanship, subject
to certain limitations.
This limited warranty does not cover any damage that results from unauthorized
or improper use, service, or repair. Further, it does not cover damage caused
by accident, impact, negligence, or normal wear and tear. Should you discover
your Medic Therapeutics Air Purifier is not functioning properly, please send
your device to our repair center for evaluation. If your product cannot be
repaired or serviced we will reserve the right to change it for a similar or
newer model.
Please note that a flat rate of $35.00 will be charged to cover a service
evaluation fee and return shipping of your device. All warranty claims must be
accompanied by a copy of our proof of purchase from an authorized retailer.
Please send your device, proof of purchase, and a check or money order in the
amount of $35.00 made out to Medic Therapeutics to:
Medic Therapeutics Service Center
3069 Taft Street
Hollywood, FL 33009
EPA Establishment Number: 97483-CHN-1
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>