electriQ ECD30 Portable Commercial Industrial Dehumidifier User Manual
- June 7, 2024
- ElectriQ
Table of Contents
electriQ ECD30 Portable Commercial Industrial Dehumidifier User Manual
Thank you for choosing electriQ.
Please read this user manual before using this innovative dehumidifier.
Please keep it safe for future reference.
Visit our page www.electriQ.co.uk for our entire
range of Intelligent Electricals
SAFETY INSTRUCTIONS
IMPORTANT
-
Carefully read the instructions before operating the unit
-
This appliance is for indoor use only and intended for use in a domestic environment only. Any other use is not recommended by the manufacturer and may cause fire, electrical shocks or other injury to user or property.
-
Rating: This unit must be only connected to a 220-240 V / 50 Hz earthed outlet.
-
Installation must be in accordance with regulations of the country where the unit is used.
-
If you are in any doubt about the suitability of your electrical supply have it checked and if necessary, modified by a qualified electrician.
-
This dehumidifier has been tested and is safe to use. However, as with any electrical appliance
– use it with care. -
Disconnect the power before dismantling, assembling or cleaning.
-
Avoid touching any moving parts of the appliance. Never insert fingers, pencils or any other objects though the guard
-
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities. It is also not intended for use by those with a lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
-
Do not leave children unsupervised with this appliance.
-
Do not clean the unit by spraying it or immersing it in water.
-
Never connect the unit to an electrical outlet using an extension cord. If a power outlet is not available, one should be installed by a qualified electrician.
-
Never operate this appliance if the cord, power adapter or plug is damaged. Ensure the power cord is not stretched or exposed to sharp objects/edges.
-
A damaged power supply cord should be replaced by the manufacturer or a qualified electrician in order to avoid a hazard.
-
Any service other than regular cleaning or filter replacement should be performed by an authorized service representative. Failure to comply could result in a voided warranty.
-
Do not use the appliance for any purpose other than its intended use.
-
Do not tilt the unit while in use. The unit is design to work only in vertical position.
-
This dehumidifier must always be stored and transported upright, otherwise irreparable damage may be caused to the compressor; if in doubt we suggest waiting at least 24 hours before starting the unit.
-
Avoid restarting the dehumidifier unless 5 minutes have passed since being turned off. This prevents damage to the compressor.
-
Never use the plug as a switch to start or turn off the dehumidifier. Use the provided ON/OFF switch located on the control panel.
-
Always place the unit on a dry and stable surface.
-
The appliance should not be installed in laundry or wet rooms where the humidity is higher than 85% RH
-
Do not dry laundry above the unit to prevent water entering the dehumidifier. Place the laundry at least 1 meter away from your dehumidifier.
-
The appliance must be placed in a room without sources of ignition (for example: open flames, an operating gas appliance or an operating electric heater).
-
R290 refrigerant gas complies with European environmental directives.
-
R290 has a low GWP (Global Warming Potential) of 3.
-
The unit contains about 280g of R290 refrigerant gas.
-
Do not use or store the appliance in an unventilated space with an area smaller than shown in the specification table per unit.
-
If the appliance is installed, used or stored in an unventilated room, the room must be such as to prevent stagnation of possible leaks of refrigerant gas as there could be a danger of fire or explosion should the refrigerant come into contact with electric heaters, stoves or other sources of ignition.
-
Refrigerant gas may be odourless.
-
Do not use the product and contact the retailer for advice, if damage has occurred to the unit which may have compromised the refrigerant system.
-
Any repairs or maintenance must only be carried out on the unit by a suitably qualified engineer. Before opening and servicing the unit the authorized engineer must be in possession of a copy of the manufacturer’s service manual and must follow the safety information contained within it to ensure all hazards are minimized.
-
The refrigerant system should not be perforated or punctured.
-
Do not place the unit next to heat sources (e.g. electrical fires, fireplaces, etc.)
-
Avoid mishandling the dehumidifier. Dropping, throwing the unit can cause damage to its internals and increases the risks of operating it.
-
Do not store or use gasoline, petrol, paint, solvents or other flammable vapours or liquids in the vicinity of this dehumidifier or any other appliance.
-
This dehumidifier must not be used in spaces where there is a high concentration of gases, solvent or other volatile organic compounds; in very dusty environments; in any domestic, commercial or industrial environment where the air composition is flammable.
ENERGY SAVING AND UNIT SAFETY PROTECTION TIPS
- Do not cover or restrict the airflow from the outlet or inlet grills. Do not operate and follow troubleshoot procedure if the self-opening louvers do not open on power on.
- For maximum performance the minimum distance from a wall or objects should be 20 cm
- Keep the filters or grills of the unit clean. Under normal conditions, filters or grills should only need cleaning once every three weeks (approximately).
- Since the filters remove airborne particles, more frequent cleaning maybe necessary, depending on the air quality. Vacuum both mesh and optional carbon filters and wash the mesh filters with hot soapy water and dry them before placing them back in the unit.
VISUAL SAFETY GUIDE ON WHERE OR WHEN NOT TO USE YOUR DEHUMIDIFIER
PARTS
FEATURES
The ECD range of dehumidifiers use compressor technology to extract water from the environment. Compressor dehumidifiers are ideal for environments which are heated during the winter months and maintain a temperature above 12-15⁰C, although these units can be used un temperatures down to 5⁰C. The dehumidifiers are easy to move around and are designed to extract unwanted humidity. They feature an intelligent humidistat where the desired relative humidity can be adjusted in increments of 5% between 40 and 95% ensuring your room is not dried too much and power is not wasted.
FEATURES
Your dehumidifier belongs to the electriQ dehumidifier range featuring power saving logic.
- Easy to use controls
- Cost effective way to combat mould, condensation and damp
- Wheels for improved mobility
- Intelligent CPU controlled digital humidistat with 40-95% RH and room humidity display
- 24 hours start / stop timer
- Built in uplift pump to drain the water collected.
- Auto restart
PRODUCT OVERVIEW
A badly positioned dehumidifier will have little effect. In positioning the
dehumidifier please ensure circulation of air in not restricted around the
unit.
Allow at least 50 cm space to the sides and back of the unit, and 100cm to the
front. This dehumidifier is designed only for indoor applications.
Use in an enclosed area for maximum efficiency. Close all doors, windows to create an effective operating environment.
Your electriQ dehumidifier will extract water from the air, protecting your space from the harmful effects of excessive moisture as soon as it is turned on. Excess moisture is dispersed throughout your home. For this reason, the dehumidifier should be positioned in a central and clear location so that it can draw this moist air towards it from all over the home. A warm hallway or landing is an excellent position for your dehumidifier. If possible, leave interior doors ajar to allow air circulation.
Alternatively, if you have a serious problem in one area you can begin by positioning the dehumidifier there and moving it to a more central location at a later date. For the most effective use, run your dehumidifier with external doors and windows kept closed. Please note the unit should not be placed directly against a radiator or other heat source.
When positioning your electriQ dehumidifier, ensure that it is placed clear of any obstacle that may limit the air movement. Place the dehumidifier on a flat dry surface.
ASSEMBLY
The appliance must be fully assembled before plugging in. In order to prevent damage to the compressor, after assembly the unit must be left in an upright position for 2 hours before plugging in.
ATTACHING THE WHEELS
- Attach the Axel to the base of the appliance using the 4 bolts provided.
- Fix the wheels onto each end of the axel using the supplied washers and nuts, ensuring that they are secure.
- Turn the appliance upright, and stand on the wheels.
ATTACHING THE HANDLE
Attach the handle to the rear of the unit using the 4 bolts provided.
OPERATION
NOTES:
- The recommended humidity for a standard room is within the range of 50% to 70%, provided no special requirements are made.
- Although the desired humidity can be set as low as 10%, lower settings will act as a continuous mode, as they are unlikely to be achievable in the UK.
CONTINUOUS DRAINAGE
The ECD70 does not include a removeable tank, and instead includes an internal uplift pump to extract the water collected. A 6 metre drainage pipe is provided attached on the side of the unit. If this needs to be extended, we advise to fit it into a pipe with a larger diameter, and ensure the larger pipe is travelling downwards. The uplift pump collects water, and then when a sufficient amount is collected it will be automatically pumped out of the unit through the drain pipe. It can be used to raise the water by upto 5 meters to drain to a sink or drain. Please note this is the maximum height, and will be affected both by the diameter of the pipe used, and the total length of the drain pipe.
To ensure effective performance of the pump, it is advised that the pipe is routed so that the upwards section is close to the unit. After the upwards section of the pipe, it should have a gentle downwards slope to prevent backflow to the pump, and aid drainage.
AUTO DEFROST
When frost builds up on the evaporator coils, the compressor will cycle off and the unit will go in to defrost mode. Following completion of the defrost mode, the unit will return to the previously operating settings.
Note: When the ambient temperature is low, the appliance will enter defrost mode more often
HUMIDITY CONTROL
When the unit reaches the desired humidity set, both the fan and compressor will shut down; and when the humidity of the room is above the desired level both fan and compressor will operate.
If the room humidity displayed appears to be incorrect, it can be adjusted by following the below:
- In standby mode, press and hold the TIMER Button for over 10 seconds.
- Both the Set Humidity and Current Humidity symbol will flicker and the humidity display will show the current humidity
- Use the UP and DOWN buttons to adjust the humidity reading.
FAULT PROTECTION
The intelligent logic within the unit will monitor the performance of the refrigerant circuit. If after 10 minutes the temperature of the cold coil within the unit has not reduced sufficiently, the unit will enter standby mode and “PRESSURE HOLDING” will be displayed on the control panel. The unit will not operate until the fault has being rectified.
CARE AND MAINTENANCE
Always shut off the unit and unplug it from the mains before cleaning or performing any maintenance. When it is not in use for long periods, it is advisable to remove the plug from the power socket. Do not use chemical solvents (such as benzene, alcohol or gasoline) as they may cause irreversible damage to the unit.
CLEAN THE AIR INLET
The Air-inlet may gather dust easily, please clean it often with a soft, damp cloth. If the filter is covered by dust, the airflow and the performance of the unit will be affected, it may even cause damage to the unit. We recommend that you regularly clean the filters. The dehumidifier must be disconnected from the socket before maintenance and the filters must be allowed to fully dry before re use.
- Remove the filters from the unit, and tap the dust away.
- cleaner or soft-brush.
- If dirt and grease is accumulated wash the mesh filter in hot soapy water.
- Replace the filters in position as shown in the diagram.
- Never use the unit without the antibacterial mesh dust filter.
CLEAN THE GRILLE AND CASE
Use water and a mild detergent to clean the washable mesh filters. Do not use bleach or abrasives. Do not splash water directly onto the main unit. Doing so may cause an electrical shock and can lead to the insulation to deteriorate, or cause the unit to rust. The air intake and outlet grilles get soiled easily, so use a vacuum attachment or soft brush to clean. Wipe the dehumidifier body with a soft damp cloth or kitchen towel.
END OF SEASON MAINTENANCE
- Clean the unit and the filter as per cleaning procedure above.
- Cover the unit and keep it in a dry place.
CAUTION:
- When not in use, the user should switch the unit off by pressing the Power button so that the indicator LED is turned off, before unplugging it from the mains.
- Always follow the safety instructions outlined at the beginning of the user manual.
- Disconnect the dehumidifier from the mains if the unit is not in use.
- To prolong the life of the dehumidifier, do not use for long periods of time without disconnecting the unit from the power supply.
TROUBLESHOOTING
TECHNICAL SPECIFICATION
- Note: Although the unit can be set to very low desired humidity levels, levels below 40% are unlikely to be achievable in most circumstances, and as such acts as the unit being set to run continuously.
FREQUENTLY ASKED QUESTIONS
Why doesn’t the dehumidifier seem to extract much water if the temperature is low?
This is a compressor dehumidifier which works best in temperatures above 15⁰C. If the temperature is low and the air is dryer than the setting on the humidistat the unit will not extract water. If you want to use a dehumidifier for outside buildings, unheated properties, boats or garages please check our desiccant range.
Why doesn’t the unit work /or stops suddenly?
The unit may be running in dehumidifying mode with a low room temperature.
Please check if the room temperature is lower than 5⁰C. If so, the unit will
stop working while in dehumidifying mode. (unit may be defrosting).
The ambient operating range is between 5⁰C and 35⁰C with a relative humidity
ranging from 30% to 80%.
For maximum efficiency use the unit between 15⁰C and 32⁰C.
Sometimes cold and/or hot air comes out from the air outlet grill, why?
When the unit is in dehumidifying mode it absorbs humid air from room and freezes it to reduce the humidity. During the cold cycle there should be cold air coming out of the unit. During the hot cycle hot dry air should be coming out of the outlet grill.
ENVIRONMENTAL PROTECTION
Disposal: Do not dispose this product as unsorted municipal waste. Collection of such waste must be handled separately as special treatment is necessary.
Recycling facilities are now available for all customers at which you can deposit your old electrical products. Customers will be able to take any old electrical equipment to participating civic amenity sites run by their local councils. Please remember that this equipment will be further handled during the recycling process, so please be considerate when depositing your equipment. Please contact the local council for details of your local household waste recycling centres.
electriQ UK SUPPORT
www.electriQ.co.uk/support
Please, for your own convenience, make these simple checks before calling the
service line.
If the unit still fails to operate call: 0871 620 1057 or complete the online
form
- Is the unit plugged into the mains? Does the power adapter works?
- Is the fuse in the power plug OK?
Office hours: 9AM – 5PM Monday to Friday
Unit J6, Lowfields Business Park
Lowfields Way, Elland
West Yorkshire, HX5 9DA
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>