MITSUBISHI ELECTRIC P-Series Ceiling Suspended Air Conditioning System User Guide

June 8, 2024
Mitsubishi Electric

MITSUBISHI ELECTRIC P-Series Ceiling Suspended Air Conditioning System

Job Name:
System Reference

Date:

Indoor Unit …… PCA-A24KA8
Outdoor Unit …….PUY-A24NHA7

INDOOR UNIT FEATURES

  • Airflow settings for high and low-ceiling applications
  • Knock-out for outside-air intake
  • Optional i-see SensorTM for air distribution and energy saving
  • Auto fan speed mode
  • Filter status indicator
  • Easy-to-clean, washable filter
  • Suspends from the ceiling for quick and easy installation
  • Ideal for larger retail stores, classrooms, and restaurants
  • Multiple control options available:
    • kumo cloud® smart device app for remote access
    • Third-party interface options
    • Wired or wireless controllers

OUTDOOR UNIT FEATURES

  • Variable speed INVERTER-driven compressor
  • Pre-charged with refrigerant volume for piping length up to 70 ft
  • Low ambient cooling down to -40°F providing 100% capacity (with wind baffles)
  • 24-hour continuous operation (cooling mode)
  • High-pressure protection
  • Fast restart
  • Superior energy and operational efficiency
  • Seacoast protection
    • External Outer Panel : Phosphate coating + Acrylic-Enamel coating
    • Fan Motor Support: Epoxy resin coating (at edge face)
    • Separator Assembly Valve Bed : Epoxy resin coating (at edge face)
    • Blue Fin treatment is an anti-corrosion treatment that is applied to the Heat exchanger coil to protect it against airborne contaminants.
    • Heat exchanger coil and base panel rated for 2,000 hours in accordance with ASTM B117 testing
  • Seacoast protection standard from 2022 production

Specifications are subject to change without notice

SPECIFICATIONS

SPECIFICATIONS: PCA-A24KA8 & PUY-A24NHA7

Cooling at 95°F1 Maximum Capacity BTU/H 24,000
Rated Capacity BTU/H 24,000
Minimum Capacity BTU/H 10,000
Maximum Power Input W 1,960
Rated Power Input W 1,960
Moisture Removal Pints/h 5.8
Sensible Heat Factor 0.73
Power Factor [208V / 230V] % 94.7 / 94.7
Efficiency SEER2 21.0
EER21 12.2
HSPF2 [IV]
ENERGY STAR® Certified No
Electrical Voltage, Phase, Frequency 208/230, 1, 60
Guaranteed Voltage Range V AC 198 – 253
Voltage: Indoor – Outdoor, S1-S2 V AC 208/230
Voltage: Indoor – Outdoor, S2-S3 V DC 24
Short-circuit Current Rating [SCCR] kA 5
Recommended Fuse/Breaker Size (Outdoor) A 25
Recommended Wire Size [Indoor – Outdoor] AWG 14
Power Supply Indoor unit is powered by the outdoor unit
Indoor Unit MCA A 1.0
Fan Motor Full Load Amperage A 0.54
Fan Motor Output W 95
Fan Motor Type DC Motor
Airflow Rate at Cooling, Dry CFM 530–565–600–670
Airflow Rate at Cooling, Wet CFM 495–530–565–635
Airflow Rate at Heating, Dry CFM 530–565–600–670
Sound Pressure Level [Cooling] dB[A] 33–35–37–40
Sound Pressure Level [Heating] dB[A] 33–35–37–40
Drain Pipe Size In. [mm] 1-1/32 [26]
Coating on Heat Exchanger
External Finish Color White Munsell 6.4Y 8.9/0.4
Unit Dimensions W x D x H: In. [mm] 50-3/8 x 26-3/4 x 9-1/16 [1,280 x 680 x

230]
Package Dimensions| W x D x H: In. [mm]| 53-7/64 x 30 x 12-41/64 [1,349 x 760 x 321]
Unit Weight| Lbs. [kg]| 71 [32]
Package Weight| Lbs. [kg]| 80 [36]
Indoor Unit Operating Temperature Range| Cooling Intake Air Temp [Maximum / Minimum]*| °F| 90 DB, 73 WB / 66 DB, 59 WB
Outdoor Unit| MCA| A| 19.0
MOCP| A| 26
Fan Motor Full Load Amperage| A| 0.4
Fan Motor Output| W| 86
Airflow Rate [Cooling / Heating]| CFM| 1940
Refrigerant Control| LEV
Defrost Method| Reverse Cycle
Coating on Heat Exchanger| Blue Fin Coating**
Sound Pressure Level, Cooling1| dB(A)| 47
Compressor Type| INVERTER-driven twin rotary
Compressor Model| SNB172FWHM1
Compressor Rated Load Amps| A| 7
Compressor Locked Rotor Amps| A| 11.0
Compressor Oil [Type // Charge]| oz.| FV50S // 23
External Finish Color| Ivory Munsell 3Y 7.8/1.1
Base Pan Heater| N/A
Unit Dimensions| W x D x H: In. [mm]| 37-13/32 x 13 (+1-3/16) x 37-1/8 [950 x 330 (+30) x 943]
Package Dimensions| W x D x H: In. [mm]| 40-15/16 x 17-11/16 x 40-11/16 [1040 x 450 x 1033]
Unit Weight| Lbs. [kg]| 151 [68]
Package Weight| Lbs. [kg]| 176 [80]
Outdoor Unit Operating Temperature Range| Cooling Air Temp [Maximum / Minimum]
| °F| 115 DB / -40 DB
Refrigerant| Type| R410A
Pre-Charged Refrigerant Amount| Lbs, oz| 7.0, 11.0
Maximum Pre-Charged Piping Length| Ft. [m]| 70.0 [20.0]
Additional Refrigerant Charge Per Additional Piping Length| oz./Ft. [g/m]| 0.3 [22.5]

NOTES:

AHRI Rated Conditions
(Rated data is determined at a fixed compressor speed) 1
Cooling (Indoor // Outdoor)

°F 80 DB, 67 WB // 95 DB, 75 WB

  • Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]):
  • Wind baffles are required to operate below 23°F DB in cooling mode.
  • The cooling-only system with advanced wind baffle: -40°F – 115°F.
  • Refer to wind baffle documentation for further information.
  • Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):
  • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.
  • Blue Fin Coating Standard from 2022 production:
  • PU(Y/Z)-A(12/18)NKA7 – Beginning with serial number 12U*****
  • PU(Y/Z)-A(24/30/36/42)NKA7 – Beginning with serial number 1ZU*****

SPECIFICATIONS: PCA-A24KA8 & PUY-A24NHA7 

Piping Gas Pipe Size O.D. [Flared] In.[mm] 5/8 [15.88]
Liquid Pipe Size O.D. [Flared] In.[mm] 3/8 [9.52]
Maximum Piping Length Ft. [m] 225 [68]
Maximum Height Difference Ft. [m] 100 [30]
Maximum Number of Bends 15

AHRI Rated Conditions
(Rated data is determined at a fixed compressor speed) 1
Cooling (Indoor // Outdoor)

°F 80 DB, 67 WB // 95 DB, 75 WB

  • Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]):
  • Wind baffles are required to operate below 23°F DB in cooling mode.
  • The cooling-only system with advanced wind baffle: -40°F – 115°F.
  • Refer to wind baffle documentation for further information.
  • Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):
  • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.
  • Blue Fin Coating Standard from 2022 production:
  • PU(Y/Z)-A(12/18)NKA7 – Beginning with serial number 12U*****
  • PU(Y/Z)-A(24/30/36/42)NKA7 – Beginning with serial number 1ZU*****

ACCESSORIES

INDOOR UNIT ACCESSORIES: PCA-A24KA8

Control Interface

| CN24 Relay Kit| □ CN24RELAY-KIT-CM3
---|---|---
IT Extender| □ PAC-WHS01IE-E
kumo station® for kumo cloud®| □ PAC-WHS01HC-E
Procon BACnet® and Modbus® Interface| □ PAC-UKPRC001-CN-1
Remote Operation Adapter‡| □ PAC-SF40RM-E
Thermostat Interface| □ PAC-US445CN-1
USNAP Adapter| □ PAC-WHS01UP-E
Remote Sensor| Flush Mount Remote Temperature Sensor| □ PAC-USSEN002-FM-1
Remote Temperature Sensor| □ PAC-SE41TS-E
Wireless temperature and humidity sensor for kumo cloud®| □ PAC-USWHS003-TH-1
Wired Remote Controller| Deluxe Wired MA Remote Controller†| □ PAR-40MAAU
Simple Ductless Wired Remote Controller| □ PAC-SDW01RC-1
Simple MA Remote Controller†| □ PAC-YT53CRAU-J
Touch MA Controller†| □ PAR-CT01MAU-SB
Wireless Remote Controller| kumo touch™ RedLINK™ Wireless Controller| □ MHK2
Lockdown bracket for remote controller| □ RCMKP1CB
Wireless MA Receiver| □ PAR-FA32MA-W
Wireless MA Remote Controller| □ PAR-FL32MA-E
Wireless Receiver Kit| □ PAR-SL93B-E
Wireless Receiver Kit with i-See sensor™| □ PAR-SA92MW-E
Condensate| Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended]| □ X87-721
Blue Diamond (MegaBlue Advanced) Condensate Pump w/ Reservoir & Sensor| □ X87-835
Refco Condensate Pump (100-240 VAC) up to 120,000 BTU/H| □ COMBI
Disconnect Switch| (30A/600V/UL) [fits 2” X 4” utility box] – Black| □ TAZ- MS303
Filter| 65% Medium Efficiency Filter (MERV 8)| □ PAC-SH89KF-E
Lineset| 10’ x 3/8” x 10’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-10
100’ x 3/8” x 100’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-100
15’ x 3/8” x 15’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-15
30’ x 3/8” x 30’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-30
50’ x 3/8” x 50’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-50
65’ x 3/8” x 65’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-65

NOTES:
PAC-SF40RM-E (Unable to use with wireless remote controller)

OUTDOOR UNIT ACCESSORIES: PUY-A24NHA7

Air Outlet Guide Air Outlet Guide (1 Piece) □ PAC-SG59SG-E
Centralized Drain Pan Centralized Drain Pan □ PAC-SG63DP-E
Drain Pan □ PAC-SG64DP-E
Control/Service Tool Control/Service Tool □ PAC-SK52ST
M- & P-Series Maintenance Tool Cable Set □ M21EC0397
Maintenance Tool Interface □ PAC-USCMS-MN-1
USB/UART Conversion Cable (Required for all laptop connections) □ M21EC1397
Hail Guards Hail Guard □ HG-A6

M-NET Converter

| M-NET Converter| □ PAC-SJ85MA-E
M-NET Converter| □ PAC-SJ95MA-E
Mini-Split Wire| 14 Gauge, 4 wire MiniSplit Cable—250 ft. roll| □ S144-250
14 Gauge, 4 wire MiniSplit Cable—50 ft. roll| □ S144-50
16 Gauge, 4 wire MiniSplit Cable—250 ft. roll| □ S164-250
16 Gauge, 4 wire MiniSplit Cable—50 ft. roll| □ S164-50
Mounting Pad| Condensing Unit Mounting Pad: 24” x 42” x 3”| □ ULTRILITE2
Stand| 18” Single Fan Stand| □ QSMS1801M
24” Single Fan Stand| □ QSMS2401M
Condenser Wall Bracket| □ QSWB2000M-1
Condenser Wall Bracket – Stainless Steel Finish| □ QSWBSS
Outdoor Unit Stand — 12” High| □ QSMS1201M
Wind Baffle| Front Wind Baffle| □ WB-PA5
Rear Wind Baffle| □ WB-RE5
Side Advanced Wind Baffle| □ WB-SD5

DIMENSIONS

INDOOR UNIT DIMENSIONS: PCA-A24KA8

MITSUBISHI-ELECTRIC-P-Series-Ceiling-Suspended-Air-Conditioning-System-FIG
\(6\)

In case of the rear pipe arrangement, make sure to .) remove the shaded portions from the independent piece.

Then put the independent piece back in initial position. (The heat exchanger might be dogged because of dust) MITSUBISHI-ELECTRIC-P-Series-Ceiling-
Suspended-Air-Conditioning-System-FIG \(7\)

  1. Drainage pipe connection(1(26mm)I.D.)
  2. Drainage pipe connection(for the left arrangement)
  3. Knockout hole for left drain-piping arrangement Refrigerant-pipe connection(gas pipe side/flared connection)
  4. Refrigerant-pipe connection (liquid pipe side/flared connection)
  5. Knockout hole for upper drain pipe arrangement Knockout hole for fresh air intake 3-15/16(@100) ® Knockout hole for wiring arrangement Ф7/8(Ф22)

Accessory…Drain socket (1(26mm) I.D.)

OUTDOOR UNIT DIMENSIONS: PUY-A24NHA7

FREE SPACE (Around the unit)

The diagram below shows a basic example.

Explanations of particular details are given in the installation manuals etc.

MITSUBISHI-ELECTRIC-P-Series-Ceiling-Suspended-Air-Conditioning-System-FIG
\(8\)

SERVICE SPACE

Dimensions of space needed for service access are shown in the below diagram.

FOUNDATION BOLTS

Please secure the unit firmly with 4 foundation (M10<W3/8>) bolts. (Bolts and washers mu

PIPING-WIRING DIRECTIONS

Piping and wiring connections can be made from 4 directions: FRONT, Right,Rear and Below.

MITSUBISHI-ELECTRIC-P-Series-Ceiling-Suspended-Air-Conditioning-System-FIG
\(11\)

Example of Notes

  1. Refrigerant GAS pipe connection (FLARE) ø15.88(5/8F)
  2.  Refrigerant LIQUID pipe connection (FLARE) ø 9.52(3/8F)
    Indication of STOP VALVE connection location

MITSUBISHI-ELECTRIC-P-Series-Ceiling-Suspended-Air-Conditioning-System-FIG
\(12\)

Piping Knockout Hole Details

MITSUBISHI-ELECTRIC-P-Series-Ceiling-Suspended-Air-Conditioning-System-FIG
\(13\)

FORM# PCA-A24KA8 & PUY-A24NHA7 – 202402

1340 Satellite Boulevard Suwanee, GA 30024
Toll Free: 800-433-4822

www.mehvac.com

MITSUBISHI-ELECTRIC-P-Series-Ceiling-Suspended-Air-Conditioning-System-FIG
14,.,.,..

www.ahridirectory.org

© 2024 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.