FURRION FACW12SA-BL Single Zone Basic Wall Thermostat Instruction Manual

June 6, 2024
FURRION

FURRION logo

Single Zone Premium Wall Thermostat
Instruction Manual
Model: FACW12SA-BL

FURRION FACW12SA-BL Single Zone Basic

View all FURRION thermostat manuals

Welcome

Thank you for purchasing this Furrion® Single Zone Premium Wall Thermostat.
Before operating your new product, please read these instructions carefully. This instruction manual contains information for safe use, installation, and maintenance of the product.
Please keep this instruction manual in a safe place for future reference. This will ensure safe use and reduce the risk of injury. Be sure to pass on this manual to new owners of this product.
The manufacturer does not accept responsibility for any damages due to not observing these instructions.
If you have any further questions regarding our products, please contact us at support@furrion.com

About your Thermostat

Product Features

Your Single Zone LCD thermostat is equipped with a liquid crystal display (LCD) to indicate the temperature set-point in Fahrenheit(°F)/Centigrade(°C) and fan speed. It is also equipped with an LCD to indicate the system’s available operation modes.
NOTE: The available operation modes will be different depending on the system installed in your RV.

  •  Liquid Crystal Display and Mode Indicators
  •  Auto Fan
  •  Room Temperature Display
  • Fahrenheit(°F)/Centigrade(°C) Display

FURRION FACW12SA-BL Single Zone Basic -

LCD Icons

FURRION FACW12SA-BL Single Zone Basic - LCD Icons

Installation

What’s in the Box

Make sure you have all the following items included in the packaging. If any item is damaged or missing, contact your dealer.
– Thermostat x 1
– Instruction Manual x 1
– Warranty Card x 1
– Self-tapping Screw x 2

Thermostat Installation
  1. Select a suitable location that is not under direct influence from light, sun or other heat sources.

  2. Rotate the thermostat cover counterclockwise and pull out the base plate. (Fig. 1)
    FURRION FACW12PA-BL Single Zone Premium - Fig. 1

  3. Use the base plate as a template and drill a hole on the vehicle wall. Extend the four-wire cables from the cutout area. Refer to the cable tag label for each cable definition. (Fig. 2)
    FURRION FACW12PA-BL Single Zone Premium - Fig. 2

  4. Fix the base plate on the wall using 2 screws. (Fig. 3)
    NOTE: Make sure the base plate is not covering the hole and squeezing the thermostat cables.
    FURRION FACW12PA-BL Single Zone Premium - Fig. 3

  5. Connect the cables to the thermostat.
    Rotate the thermostat clockwise until it clips into place. (Fig. 4 and Fig. 5)
    FURRION FACW12PA-BL Single Zone Premium - Fig. 4

Operation

Your Furrion wall thermostat has been preprogrammed with factory default settings. Review the settings below and adjust to your comfort level.

FACTORY SETTINGS

HEATING| 68ºF / 20ºC
COOLING| 72ºF / 22ºC
FAN SPEED| AUTO
MODE| COOL
FURNACE DIFFERENTIAL| 2ºF

Turn On/Off the Thermostat

FURRION FACW12SA-BL Single Zone Basic - To turn On

To turn On
Press and hold the button for 3 seconds to turn on the thermostat. The thermostat LCD will be illuminated and the factory settings will be displayed on the LCD for first-time use.
NOTE: The LCD will display the last setting if you have changed the parameters.

To turn Off
Press and hold button for 3 seconds to turn off the thermostat. Only the current room temperature will be displayed on the LCD.

Temperature Format

FURRION FACW12SA-BL Single Zone Basic - Temperature
Format

Simultaneously press both ∧ and ∨ buttons for 3 seconds to toggle the temperature format between Centigrade and Fahrenheit.
NOTE: ºF indicates Fahrenheit and ºC indicate Centigrade.

Operation Mode

FURRION FACW12SA-BL Single Zone Basic - Operation Mode

After the thermostat is turned on, press the button repeatedly to toggle through the available modes. The activated mode icon and temperature set-point will be displayed on the LbCD. The thermostat will transmit the last selected operation mode command to the control box after 2 seconds without any operation.
Depending on the system installed, there are 4 available modes (COOL, HEAT,   FAN and DRY) for you to select. See the following tables for detailed information of each mode.
NOTE: The HEAT mode is only available after the furnace is enabled.

COOL MODE

  •  The system will cycle the compressor on and off based on the room temperature and the temperature set-point.
  • The fan will be turned on after the compressor is running.
  • There are 4 fan speed selections in this mode.

Low| The fan operates continuously at low speed and the icon displays on the LCD.
Med| The fan operates continuously at medium speed and the icon displays on the LCD.
High| The fan operates continuously at high speed and the icon displays on the LCD.
Auto| The fan speed varies depending on the difference between the temperature set-point and room temperature. The icon displays on the LCD.
HEAT MODE

NOTE: The HEAT mode is only available when the furnace is enabled.

  • The system will cycle the furnace on and off based on the room temperature and temperature setpoint.
  • There are 4 fan speed selections in this mode.
  • The fan speed selections only apply to the rooftop fan that is part of the Air Conditioner. The fan speed selection does not change the fan speed of the furnace.

Low| The fan operates continuously at low speed and the icon displays on the LCD.
Med| The fan operates continuously at medium speed and the icon displays on the LCD.
High| The fan operates continuously at high speed and the icon displays on the LCD.
Auto| The fan speed varies depending on the difference between the temperature set-point and room temperature. The  icon displays on the LCD.
OFF| The fan is off. The icon displays on the LCD.
FAN MODE

  •  The temperature set-point is not available.
  • There are 3 fan speed selections in this mode.

Low| The fan operates continuously at low speed and the icon displays on the LCD.
Med| The fan operates continuously at low speed and the icon displays on the LCD.
High| The fan operates continuously at high speed and the icon displays on the LCD.

DRY MODE

  •  The compressor runs continuously when the room temperature is higher than set point.
  •  Compressor cycles ON for 10 minutes and OFF for 6 minutes when the room temperature is lower than the set-point.
  • The fan speed runs continuously at low speed.
Set the Temperature

FURRION FACW12SA-BL Single Zone Basic - Set the
Temperature

The temperature set-point ranges from 60ºF~86ºF (16ºC~30ºC).

  1. Press the button to toggle to your desired mode.
  2. Press ∧ or ∨ button to increase or decrease the temperature set-point to your comfort level.
    NOTE: The temperature set-point is not available in FAN mode.
Set the Fan Speed

FURRION FACW12SA-BL Single Zone Basic - Set the Fan
Speed

  1. Press the button repeatedly to toggle to your desired mode.
  2. Press the FAN button to select AUTO, HIGH, MEDIUM or LOW fan speed.
    NOTE: The fan speed selection is not available in DRY mode.

Special Features

Auto Fan

When the auto fan mode is selected, the fan speed will vary depending on the temperature difference between the temperature set-point and the room temperature.

Temperature
Difference| Fan Speed
---|---

3ºF| The fan operates on High level
1ºF| The fan operates on Med level
<-1ºF| The fan operates on Low level

Compressor Time Delay

A time delay of approximately three minutes occurs any time the compressor is required to begin the cooling cycle.
NOTE : The time delay occurs automatically after a mode is selected or a power event occurs to ensure the pressure in the compressor is equalized appropriately, to prevent damage.
Power Interruption
In the event the power to the air conditioner or controller is interrupted, the system will restart automatically with the last status and operational parameter set-points once the power is restored.

LCD Error Code

The following error code will be displayed on the LCD when the system detects one of the following faults has occurred.

LCD Error Code

E1| Indoor temperature sensor out of order. The system will shut down.
E2| Evaporator temperature sensor out of order. The system will shut down.
E3| Loss of communication between the thermostat and control box. System
will shut down.
E4| Condenser temperature sensor out of order. The system will shut down.
E5| Outdoor temperature sensor out of order. The system will shut down.
lo| Insufficient low level of +12V power supply. The system will shut down.

Wiring Diagram

FURRION FACW12SA-BL Single Zone Basic - Wiring DiagramFURRION FACW12SA-BL Single Zone Basic - Wiring
Diagram2

Specifications

DC Input Power DC 12V
Power Consumption <0.5W
Baud Rate 9600bps
Dimension 3 x 3 x 15/16” (75 x 75 x 22.5mm)
Weight 0.06kg
LCD Viewing angle 12 o’clock

Warranty

FURRION WARRANTS FOR A PERIOD OF 1 YEAR FROM DATE OF RETAIL PURCHASE BY THE ORIGINAL END-USER PURCHASER, THAT THIS PRODUCT, WHEN DELIVERED TO YOU IN NEW CONDITION, IN ORIGINAL PACKAGING, FROM A FURRION AUTHORIZED RESELLER AND USED IN NORMAL CONDITIONS, IS FREE FROM ANY DEFECTS IN MANUFACTURING, MATERIALS, AND WORKMANSHIP. IN CASE OF SUCH A DEFECT, FURRION SHALL REPLACE OR REPAIR THE PRODUCT AT NO CHARGE TO YOU. THIS WARRANTY DOES NOT COVER: PRODUCTS WHERE THE ORIGINAL SERIAL NUMBERS HAVE BEEN REMOVED, ALTERED, OR CANNOT READILY BE DETERMINED; DAMAGE OR LOSS CAUSED BY ACCIDENT, MISUSE, ABUSE, NEGLECT, PRODUCT MODIFICATION, FAILURE TO FOLLOW INSTRUCTIONS IN INSTRUCTION MANUAL, COMMERCIAL OR INDUSTRIAL USE; DAMAGE OR LOSS CAUSED TO THE DECORATIVE SURFACE OF PRODUCT; TO ANY DATA, SOFTWARE OR INFORMATION; AND NORMAL WEAR AND TEAR. THIS WARRANTY ONLY PROTECTS THE ORIGINAL END-USER (“YOU”) AND IS NOT TRANSFERABLE; ANY ATTEMPT TO TRANSFER THIS WARRANTY SHALL MAKE IT IMMEDIATELY VOID. THIS WARRANTY IS ONLY VALID IN THE COUNTRY OF PURCHASE. THIS WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, REMEDIES, AND CONDITIONS, WHETHER ORAL OR WRITTEN, EXPRESS OR IMPLIED. FURRION SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IF FURRION CANNOT LAWFULLY DISCLAIM IMPLIED WARRANTIES UNDER THIS LIMITED WARRANTY, ALL SUCH WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO THE DURATION OF THIS WARRANTY.
No Furrion reseller, agent, or employee is authorized to make any modification, extension, or addition to this warranty.
FURRION IS NOT RESPONSIBLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF WARRANTY OR CONDITION, OR UNDER ANY OTHER LEGAL THEORY, INCLUDING BUT NOT LIMITED TO LOST PROFITS, DOWNTIME, GOODWILL, DAMAGE TO OR REPLACEMENT OF ANY EQUIPMENT OR PROPERTY, ANY COSTS OF RECOVERING, REPROGRAMMING, OR REPRODUCING ANY PROGRAM OR DATA STORED IN OR USED WITH FURRION PRODUCTS. FURRION’S TOTAL LIABILITY IS LIMITED TO THE REPAIR OR REPLACEMENT OF THIS PRODUCT PURSUANT TO THE TERMS OF THIS WARRANTY. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES OR EXCLUSIONS OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES OR CONDITIONS, SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY BY STATE OR (WHERE APPLICABLE IN THE COUNTRIES WHERE FURRION HAS NON-US/CANADIAN AUTHORIZED DEALERS) COUNTRY. NO ACTION OR CLAIM TO ENFORCE THIS WARRANTY SHALL BE COMMENCED AFTER THE EXPIRATION OF THE WARRANTY PERIOD. Keep your receipt, delivery slip, or another appropriate payment record to establish the warranty period. Service under this warranty must be obtained by contacting Furrion at warranty@furrion.com
Product features or specifications as described or illustrated are subject to change without notice.

FURRION logo

Furrion Innovation Center & Institute of Technology
52567 Independence Ct., Elkhart, IN 46514, USA Toll free:1-888-354-5792
Email: support@furrion.com
©2007-2018 Furrion Ltd. Furrion® and the Furrion logo are trademarks licensed for use by Furrion Ltd. and registered in the U.S. and other countries. FURRION.COM
IM-FHA00025 V1.0

Furrion FACW12SA-BL SINGLE ZONE BASIC WALL THERMOSTAT Instruction Manual

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals