Furrion WF8023 Wireless Module User Manual

June 6, 2024
FURRION

Furrion LOGO

Furrion WF8023 Wireless Module

OEM/Integrators Installations

Note: The module is limited to OEM installation ONLY;
The OEM integrator is responsible for ensuring that the end‐user has no manual instructions to remove or install module. If the FCC identification number is not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. This exterior label can use wording such as the following:

“Contains Transmitter Module FCC ID: 2ABH3-FOSFDTA”
When the module is installed inside another device, the user manual of this device must contain below warning statement:

  1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
  2. This device may not cause harmful interference.
  3. This device must accept any interference received, including interference that may cause undesired operation.
  4. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

FCC STATEMENT

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generate, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is  connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Note: The Grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. Such modifications could void the user’s authority to operate the equipment.

That separate approval is required for all other operating configurations, including portable configurations with respect to Part 2.1093 and different antenna configurations. This product is mounted inside of the end product only by professional installers OEM. They use this module with changing the power and control signal setting by software of end product within the scope of this application. End user cannot change this setting. The equipment complies with RF exposure limits. This module is limited to installation in mobile or fixed applications. The antenna used for this transmitter must not be co‐located or operating in conjunction with any other antenna or transmitter. The device has been evaluated to meet general RF exposure requirement. To maintain compliance with FCC’s RF exposure guidelines, this equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body. If the IC identification number is not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. This exterior label can use wording such as the following:

“Contains Transmitter Module IC: 23337-FOSFDTA”
When the module is installed inside another device, the user manual of this device must contain below warning statements: This device complies with Industry Canada license‐exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

Setup

Installation:

  1. Connect 3.3V regulate power to the Module 3.3V pin.
  2. Connect GDN to Module GND.
  3. Connect Enable pin to Module REST pin.
  4. Connect Host USB Interface DP/DM to module DP/DM
  5. Connect antenna to Module RFA or RFB pin.

Note:
One side of a coaxial cable (RG178) is connected to the antenna pin of the module, and the other side is connected to the antenna through the RP-SMA connector. The length of coaxial cable is 0.18m.

Antenna Specification

  • Frequency Range(MHz) :2.4GHz~2.5GHz
  • Impedance(Ω): 50
  • Peak Gain(dBi): 3.0dBi
  • VSWR: ≤1.8
  • Admitted Power: 50W
  • Polarization: Linear, Vertical
  • Radiation: Omni-directional
  • Connector: RP-SMA

More module information is provided below:Furrion-WF8023-Wireless-Module-
FIG-2

Pin Assignment

Furrion-WF8023-Wireless-Module-
FIG-3

Pin NO. Pin Name Pin Description I/O
1 RST Connect to 3.3V via a 100k resistor I

2,6,

8,10

|

GND

|

Ground

|
3| DP| USB Interface DP| I/O
4| DM| USB Interface DM| I/O
5| 3.3V| Power Supply| I
7| RFA| Connect to antenna| I/O
9| RFB| Connect to antenna| I/O

Outline Dimension

Furrion-WF8023-Wireless-Module-
FIG-4

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

FURRION User Manuals

Related Manuals