Sundial RF²Pack 5
Wireless Enabled 2 Zone Programmer and Thermostats (Y9520Z1007)
In a heating system that has no room thermostat, or the system needs upgrading to 2 heating zones, the existing wiring can be used to provide a Boiler Interlock by fitting Sundial RF² Pack 5.
The pack contains:
- A wireless-enabled 2 zone programmer (ST9520C)
- 2 x wireless room thermostats (DT92E).
Communication between the programmer and thermostat, as well as features such
as Optimum Start,
Delayed Start and Optimum Stop, enable users to save money and energy.
FEATURES
- Energy-saving Time Proportional and Integral (TPI) control
- Wireless-enabled upgrade
- Two-way wireless communication
- Wireless signal strength indicator
- Built-in Economy or Comfort programs on ST9520C
- Line of Text (LoT) display for easy programming on ST9520C
- ST9520C fits on industry standard backplate
- ECO setback function on DT92E
- Frost protection on DT92E
- Table-top stand supplied with DT92E
- Battery-powered DT92E – no wiring
OPTIONS
-
OpenTherm Boiler Control**** (with suitable OpenTherm Boiler)
-
Remote Boiler control with wireless relay box (BDR91 supplied separately)
-
Remote Valve control with wireless relay box (BDR91 supplied separately)
-
Service interval reminder with variable levels of action
-
Installer set-up mode – controls can be matched to the system and user
-
Optimum Start: To save energy, let the controls work out when to come on to suit when you want to be warm. Every day, the boiler will start at the latest possible moment depending on the weather.
** Delayed Start: Once you have programmed your earliest start time, the controls will delay the boiler firing time on warmer days, when it is possible to save energy.
* Optimum Stop: Saves energy and money by switching off before the normal program time whenever possible.
** OpenTherm Boiler Control: OpenTherm provides more precise control on the boiler through the control of the gas valve. It enables the amount of heat provided by the boiler to be controlled to match the varying demand signal. By reducing the flow temperature to a minimum as it leaves the boiler, the return temperature is kept below the dew
point (55°C) whenever possible, thus enabling the boiler to operate in condensing mode.
Installation
Simply remove the old programmer and replace with ST9520C. This enables the
wireless thermostats (DT92E) to be added to the system. Otherwise, install as
per installation instructions supplied with the product. Remote boiler and
remote valve installations are possible with wireless relay boxes (supplied
separately).
The ST9520C and DT92E are radio frequency devices and for best performance
should be installed in a clear space. Where possible, leave the ST9520C at
least 30 cm from any metal objects, including wall boxes, and at least 1 m
from any other electrical equipment. The 2 x DT92E are free to be installed in
suitable locations where the signal strength is high.
Wiring
For full wiring instructions, please refer to the Wiring Guide or download the
Honeywell Home Wiring Guide App from the Apple App Store or Google Play Store.
https://itunes.apple.com/gb/app/wiring-guide/id1445695073?mt=8
https://play.google.com/store/apps/details?id=com.phonegap.wiringguide&hl=en_GB
SPECIFICATION
Pack 5
RF Operation Band| ISM (868.0 to 868.6 MHz), 1% duty cycle
RF Communication Range| Typically 30 m in residential building
RF Communication Technology| Two way short, high rate transmissions to
minimize air time / avoid interference
RF Blocking Immunity| Receiver class 2
Operating Temperature Range| 0 to 40°C
Operating Humidity Range| 10 to 90% RH, non-condensing
Storage Conditions| −20 to 55°C
10 to 90% RH, non-condensing
Standards| CE marked
IP Rating| IP30
ST9520C
Switch Rating| 3(3)A max at 230 VAC
Switch Type| 2x Single pole, double-throw (SPDT) relay
Power Supply| 230 VAC 50 Hz 10 W
Power Reserve| Built-in battery maintains factory-set date and time. The
backup supercapacitor retains real-time for more than 1.5 hours All settings
and parameters stored in NVRAM will be retained indefinitely
Wiring| Wiring terminals with captive cage clamps, accepting two wires each up
to 2.5 mm 2
Time Setting Resolution| Time of day – 1 minute Programme time changes – 10
minutes
Time Display| 24 hour or 12 hour AM/PM format
Timing Accuracy| Typically better than 10 minutes per year Time and date
factory set
DT92E
Power Supply| Two AA-size, 1.5 V alkaline batteries
Temperature Setting Range| 5 to 35°C in 0.5°C steps can be limited between 5
and 35°C
OFF Setpoint Temperature| 5°C (default) Can be set between 5 and 16°C or
turned off
ECO Setpoint Temperature| 18°C (default)Can be set between 5 and 35°C (in 1°C
steps), for 1 to 24 hours
Temperature Control Accuracy| ±0.5 K at 20°C (50% load, 3 K/hr)
For more information heatingcontrols.honeywellhome.com
ErP energy efficiency ratings
The ErP energy efficiency ratings shown in this brochure will provide
installers and end-users with the information required to both complete the
ErP energy label and assess the benefits of the heating controls to the
overall heating system in the property. These ratings apply to room
thermostats (including programmable thermostats).
ENR3 0055 UK01 D0419
© 2019 Ademco 1. All rights reserved.
This document contains proprietary information of Ademco 1 and its affiliated
companies and is protected by copyright and other international laws.
Reproduction or improper use without the specific written authorization of
Ademco 1 is strictly forbidden. The Honeywell Home trademark is used under
license from Honeywell International Inc.
Resideo Technologies, Inc.
200 Berkshire Place
Winnersh
Berkshire
RG41 5RD
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>