TRIPLETT CM1000 1000A TRMS AC Clamp Meter User Manual

June 6, 2024
TRIPLETT

CM1000 1000A TRMS AC Clamp Mete

User Manual
CM1000 1000A TRMS AC Clamp Meter
Introduction
Congratulations on your purchase of the Triplett CM1000 1000A True RMS AC Clamp meter. The CM1000 True RMS AC Clamp meter features:
AC Current measurements up to 1000A. Variable Frequency Drive (VFD) Voltage Measurements Inrush Current Mode Temperature Measurements Non-contact AC voltage detection Lo Z Voltage Measurement

Safety
International Safety Symbols
This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.
This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present
Double insulation
SAFETY NOTES Do not exceed the maximum allowable input range of any function. When the instrument is not in use, press the ON/OFF key to turn off the meter. Remove the battery if meter is to be stored for longer than 60 days.
CAUTIONS Improper use of this meter can cause damage, shock, injury or death. Read and understand this user manual before operating the meter. Always remove the test leads before replacing the battery. The meter itself for any damage before operating the meter. Repair or replace any damage before use. Use great care when making measurements if the voltages are greater than 25VAC rms or 35VDC. These voltages are considered a shock hazard. Voltage checks on electrical outlets can be difficult and misleading because of the uncertainty of connection to the recessed electrical contacts. Other means should be used to ensure that the terminals are not “live”.

Description
Meter Description

Display Icons Description

Operation

Maintenance
WARNING: To avoid electrical shock, disconnect the meter from any circuit, remove the test leads from the input terminals, and turn OFF the meter before opening the case. Do not operate the meter with an open case.
Cleaning and Storage Periodically wipe the case with a damp cloth and mild detergent; do not use abrasives or solvents. If the meter is not to be used for 60 days or more, remove the battery and store it separately.
Type K Temperature Probe Replacement
Note: To use a Type K thermocouple probe that is terminated by a
subminiature (Flat blade) connector, a subminiature-to-banana plug adaptor is required.

Specifications

General Specifications

Dimensions 9.8″ x 3.2″ 1.7″ (24981.542.2mm)

Weight

11.2 oz (320g)

Warranty Information Triplett / Jewell Instruments extends the following warranty to the original purchaser of these goods for use. Triplett warrants to the original purchaser for use that the products sold by it will be free from defects in workmanship and material for a period of (1) one year from the date of purchase. This warranty does not apply to any of our products which have been repaired or altered by unauthorized persons in any way or purchased from unauthorized distributors so as, in our sole judgment, to injure their stability or reliability, or which have been subject to misuse, abuse, misapplication, negligence, accident or which have had the serial numbers altered, defaced, or removed. Accessories, including batteries are not covered by this warranty