SOEHNLE 68122 400 Air Fresh Clean Purifier Instruction Manual
- June 6, 2024
- SOEHNLE
Table of Contents
- Safety instructions
- Scope of delivery
- Device description (Fig. 1.1)
- Intended Use
- Air purification
- Before first use
- Daily use and operation
- Cleaning and care
- Replacing the filter
- Transport and storage
- Troubleshooting
- Spare and wear parts
- Soehnle Customer Service
- Further information
- Warranty
- Technical data
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
AIR FRESH
CLEAN400
USER MANUAL
Safety instructions
Read these operating instructions carefully before using the Airfresh Clean
400.
Warning!
-
Before commissioning, check that the voltage specification corresponds to the local mains voltage.
-
This device may only be used by children 8 years of age and older and by persons with limited physical, sensory or mental abilities or lack of experience and knowledge if they have been supervised or instructed in the safe use of the device and understand the resulting hazards. Cleaning and maintenance of the appliance must not be carried out by children without supervision. Children are not allowed to play with the device.
-
Always turn off the appliance and unplug the power cord from the outlet before moving or transporting the appliance.
-
Do not operate the device with a defective mains plug or mains cable.
-
Do not spray flammable materials, such as in sect poisons or fragrances around the Airfresh Clean 400.
-
Make sure that the air inlet and outlet are not covered.
-
Do not insert any objects into the air inlet of the unit. It may damage the device or cause injury.
-
Do not use or store the product where it may fall into a bathtub, sink, water or other liquid.
Do not reach for a device that has fallen into water or other liquid. Do not reach into water or other liquids, even if the unit is not connected at this time. If damp, there is a risk of electric shock when the unit is reconnected to the wall outlet. Wipe off moisture with a dry cloth. Do not touch the plug or device with wet hands -
The filter has to be changed, do not unscrew the device beyond that. In particular, replacement of the UVC lamp by the user is not permitted.
Caution!
- If the power outlet used to operate the Air fresh Clean 400 is not properly connected, the appliance’s plug will become hot. Make sure that you are using a properly connected pow er outlet for the device.
- Do not place any objects on the Airfresh Clean 400 and do not sit or stand on it.
- Only use the original Soehnle filter, which is specially designed for this Airfresh Clean 400.
- Do not use the Airfresh Clean 400 after using incense as an insect repellent or in places where oil residues, chemical vapors, or incense sticks are present.
- Do not use the Airfresh Clean 400 near heaters open fireplaces or gaspowered devices.
Scope of delivery
1x Soehnle Airfresh Clean 400
1x Soehnle HEPA combination filter
for Airfresh Clean 400
1x instruction manual
Device description (Fig. 1.1)
A: control console
B: air outlet
C: PM 2.5 Sensor (fine dust sensor)
with protective flap
D: Housing and air inlet
E: UVC lamp
F : Soehnle HEPA combination filter (68129)
G: removable case back
H: screw cap
Intended Use
The Airfresh Clean 400 is used exclusively for cleaning the room air.
Air purification
With the Soehnle HEPA combi filter, you can remove a large number of unwanted
particles and odors from the room air. Microorganisms and viruses are
destroyed by switching on the UVC light.
Pre-filter:
Captures coarse dust.
Soehnle HEPA combination filter:
A HEPA filter detects dust, smoke, pollen and other allergens. An activated
carbon filter filters odors from the air.
UV-C light:
Destroys microorganisms such as germs, viruses, bacteria, fungal spores, and
mold toxins (mycotoxins).
Before first use
-
Place the unit upright on a firm, level surface.
Maintain a minimum distance of half a meter from the unit to each wall. -
To ensure optimum performance of the unit, ensure that the air inlets and outlets are not blocked.
-
Check the power cord to make sure it is free of damage.
-
Turn and open the underside of the unit as described in Chapter 8. Remove and unpack the Soehnle HEPA combi filter. Then insert the unpacked filter again, close the device again and turn it over again.
-
Wait until the device has reached room temperature (approx. 2 hours).
-
Connect the power cord to a wall outlet.
Daily use and operation
PM 2,5 sensor and LED ring
The current air quality is continuously determined by Airfresh Clean 400 in
the form of the PM 2.5 value. The PM 2.5 value is the fine dust load (50% of
particles approx. 2.5μm) in μg/m 3
.The illuminated LED ring on the upper side indicates the current level of
fine dust pollution caused by different colors:
RED = high load (>50 µg/m³)
PINK = medium load (20 50 µg/m³)
LILA = low load (10 20 µg/m³)
BLUE = no load (0 10 µg/m³)
Please remove the protective flap in front of the PM2.5 sensor (C) only in an
emergency. Please do not allow any objects or other foreign bodies to come
into contact with the sensor.
Switching on and off
Press the ON/OFF button (L) to turn the Air fresh Clean 400 on or off. The
ON/OFF control lamp lights up.
First press:
The device is switched on
Press twice:
Activates the automatic mode
Press the third time:
Deactivates the automatic mode.
Press four times:
The device is switched off
The control lamps light up accordingly.
Automatic mode
By pressing the (L) button as described above, the Airfresh Clean 400 is also
set to automatic mode. In this mode, the unit automatically adjusts the fan
speed in relation to the air quality in the room. This ensures you always get
the best possible air quality. The control lamp for AUTO lights up.
Setting the operating time
Press button (I) to set the desired operating time. Choose between 2, 4, and
8 hours. The control lamp lights up ac accordingly. The device switches off
automatically after the time has elapsed. If no operating time has been
selected (no indicator light is lit), the Airfresh Clean 400 runs in
continuous operation.
Changing the fan speed
Press button (K) to select the fan speed and thus the desired intensity of
air discharge:
Low (I) – Medium (II) – High (III) –
Turbo (all indicator lights on)
UV-C lamp and night mode
Press button (J) once to switch on the UVC lamp inside the Airfresh Clean
400 (UVC control lamp lights up). Press again to activate the night mode
without switching off the UVC lamp (UVCcontrol lamp lights up, NIGHT control
lamp flashes). By further pressing the button (J) you can switch off the UVC
lamp (UVC control lamp is off, NIGHT control lamp flashes) or switch both off
(UVC control lamp is off, NIGHT control lamp is off ).
Night mode
In night mode, you can run the Airfresh Clean 400 without being disturbed by
additional light sources. If you activate the night mode, all indicator lights
on the device are switched off after 10 secones without the device being
switched off. Previously made settings for operat ing time and fan speed are
retained. The activation of the night mode is initiated by a flashing of the
control lamp before the lighting is switched off completely.
The device can run either in night mode or in automatic mode. These two modes
cannot be activated at the same time.
Active Restart Function
Enables operation via a controllable socket or timer. If the power supply is
interrupted, the device remembers all settings and continues to run
automatically with the same settings as soon as the power supply is restored.
Cleaning and care
Cleaning the combination filter
Regular cleaning of the combination filter (once a month) guarantees
troublefree operation of the Airfresh Clean 400 and maximum indoor air
quality.
Proceed as follows:
-
Switch off the device before each cleaning and unplug the mains plug.
-
Turn the unit upside down and place it on a firm surface (2.1).
-
Open the screw cap on the bottom of the unit (2.2).
-
Lift off the bottom of the housing (2.3).
-
Remove the Soehnle HEPA combi filter (2.4) and clean it.
The prefilter is attached to the filter with Velcro. Clean the prefilter under running water. Make sure the prefilter is dry before reattaching it to the Soehnle HEPA combi filter. The Soehnle HEPA combination filter should only be cleaned with a vacuum cleaner. -
Reinsert the filter and make sure it is properly inserted.
-
Close the device (3) and tighten the screw cap. Turn the device back the right way round and place it on a firm surface. Make sure that the base plate is correctly inserted and locked into the locking guide. Also, note the arrow marking on the opposite side of the bottom gap (3). This closes the plate airtight with the bodies.
-
Reconnect the power cord to a wall outlet and turn on the power.
Cleaning the housing
Switch off the device before each cleaning and unplug the mains plug. Clean
the housing of the Airfresh Clean 400 with a lightly moistened cloth.
Replacing the filter
The combination filter should be replaced by a new one after approx. 4320 operating hours. After approximately 4320 operating hours, the ON/OFF indicator light on the instrument’s control panel flashes to indicate the recommended filter change. Only use original Soehnle filters! To change the filter, proceed as follows:
- Switch off the appliance and unplug it from the main supply.
- Open the unit as described in chapter 8 and remove the Soehnle HEPA combi filter (2.4).
- Now insert the new Soehnle HEPA combina tion filter into the housing. Make sure that the new filter unit is inserted correctly.
- Close the device and tighten the screw please make sure that the device is proper closed (see chapter 8, point 7). Turn the device back the right way round and place it on a firm surface.
- Reconnect the power cord to a wall outlet and turn on the power.
- Press the ON/OFF button (L) for 5 seconds filter time is reset.
Transport and storage
Transport
WARNING!
Always switch off the device before transport.
Always unplug the power cord from the outlet.
Storage
We recommend that you carefully clean your Airfresh Clean 400 before storing
it. Please make sure that all parts are clean and dry before storage. Store
the Airfresh Clean 400 in a cool, dry place.
Troubleshooting
Before performing any of the following tests, turn off the power and unplug the appliance. Problem: The device does not work
- Check that the Airfresh Clean 400 is connected to a power source.
- Check that a filter is inserted and correctly positioned.
- Check that the bottom cover is correctly seated and firmly closed with the screw cap (see chapter 8).
Problem: Insufficient airflow
- Check that the filter is clean. If dirty, clean it.
- Check that the air inlets and outlets are not blocked or obstructed.
Problem: Excessive noise
- Check whether there are any foreign objects in the fan and remove them if necessary by turning the unit upside down.
- Check that the filter is clean. If dirty, clean it.
- Check that the filter is seated correctly.
- Check that the unit is standing securely and straight on a firm surface.
Problem: The device shows constantly high values
- Reset the sensor: Switch on the device. Press the ON/OFF button (L) for 5 seconds and let the unit run for 25 hours (depending on room size). The device indicates by flashing the two control lamps ON/OFF and AUTO as soon as the sensor has been reset.
Spare and wear parts
- 68129 Soehnle HEPA Combifilter
(Prefilter, HEPA Filter & Activated Carbon Filter)
Further spare parts can be ordered directly from us. Please contact our customer service depart ment.
Soehnle Customer Service
For questions and suggestions please contact our consumer service.
Contact possibilities and further information on our products can be found at
www.soehnle.com.
Further information
Declaration of conformity
Products marked with this symbol comply with applicable European directives.
The EU Declaration of Conformity can be found under
www.soehnle.com.
Disposal of used electrical products
Please do not dispose of the device in the household waste.
Should you need to dispose of your appliance, it should first be rendered
unusable (e.g. by cutting off the cord and the plug) and then disposed of in
accord ance with current regulations.
Your local authority will be able to provide you with the necessary
information.
Dispose of packaging appropriately.
Warranty
Leifheit AG grants you a 2year warranty on this quality product from the date
of purchase (or, in the case of orders, from the date of receipt of the
goods). The warranty claims must be asserted immediately after the occurrence
of the defect within the warranty period. The warranty extends to the quality
of the products.
Excluded from the warranty are:
- Wear and tear caused by use or other natural causes,
- Damage due to improper use or handling (e.g. B. shock, impact, fall),
- Damage caused by nonobservance of the specified operating instructions. In the event of a warranty claim, Leifheit will either repair defective parts or replace the product at its own discretion. If a repair cannot be carried out and an identical product is no longer available in the assortment for the purpose of replacement, you will receive a replacement product that is as similar as possible. A refund of the purchase price is not possible in case of a warranty. Furthermore, this warranty does not grant any claims for damages. To make a warranty claim, please contact the dealer from whom you purchased the product by presenting the defective product and the proof of purchase (copy). This warranty is valid worldwide. Your statutory rights, in particular warranty rights, continue to apply to you and are not limited by this warranty.
Technical data
Article number | 68122 |
---|---|
Room size up to | 38 m |
Working environment | 5°C ∼ 40°C, 10 ∼95% RH |
operating voltage range | 220 – 240V∼Alternating current |
current frequency | 50 / 60Hz |
Rated power of the system | 6W [±2096] (I), 7W [±20%] (II), 10W [±1596] (III), |
26W [±1096] (Turbo)
Dimensions| 231 (0) x 391 (H) mm
Volume| 30 dB (I), c37 dB (II), 5.47 dB (III), .60 dB (Turbo)
Weight| 2.8 kg
UV light Wavelength| 254 nm
The service life of the IN-C lamp| approx. 15,000 hours
****The product is double insulated and corresponds to protection class 2.
(I) = Fan stage 1
(II) = Fan stage 2
(III) = Fan stage 3
(Turbo) = Fan stage 4
Quality & Design by
LEIFHEIT AG
Leifheitstraße 1
56377 Nassau/Germany
www.soehnle.com
References
Read User Manual Online (PDF format)