Lenovo IBM 1000VA and 1500VA LCD Tower UPS Owner’s Manual
- June 3, 2024
- Lenovo
Table of Contents
Lenovo IBM 1000VA and 1500VA LCD Tower UPS
IBM 1000VA and 1500VA LCD Tower UPS
Product Guide (withdrawn product)
The IBM 1000VA and 1500VA LCD Tower Uninterruptible Power Supply (UPS)
offerings provide power protection with increased efficiency and simplified
power management to safeguard high-availability IBM System x server
environments. With efficiency ratings of 95% or greater, these compact tower
designs can help reduce energy usage without compromising performance or
reliability.
The IBM LCD Tower UPS is shown in Figure 1.
Figure 1. IBM LCD Tower Uninterruptible Power Supply
Did you know?
The IBM 1000VA and 1500VA LCD Tower UPS offerings have a bright, easily
customizable, and graphical LCD display that lets you configure the device and
displays important UPS status information in one of nine languages.
These units can also enhance system availability with intelligent individual
receptacle groups or load segments that can be programmed and controlled,
allowing mission-critical devices to be prioritized during shutdown to
preserve battery run time in the event of a prolonged power outage.
Additionally, these units come equipped with a communication bay that allows
the installation of an optional network management card (46M4110). The network
management card provides convenient over-the-network UPS remote monitoring and
management through a standard web browser. This solution features advanced
capabilities, such as secure, remote flash upgradeable firmware for both the
UPS and network management card, which makes it an ideal solution for remote
locations.
About uninterruptible power supplies
An uninterruptible power supply (UPS) is a device that acts as a defensive
barrier between electronic equipment and incoming power problems. It
conditions, regulates, and filters out power disturbances to ensure a clean
power source for IT equipment. A UPS also provides battery backup in the event
of a power failure.
In today’s high availability server environments, unplanned power outages or
line quality irregularities can have a considerable financial impact on all
sized businesses. The typical utility power is 99.9% available, but that means
that there can be almost 9 hours of downtime a year, not to mention brownouts
and other power quality problems.
Selecting the right IBM UPS can help protect against these potentially costly
incidents.
Part number information
Table 1 shows the orderable part numbers and feature codes for the IBM 1000VA
and 1500VA LCD Tower UPS offerings.
Table 1. Ordering part numbers and feature codes
The UPS models include the following items:
Description | Part number | Feature code |
---|---|---|
IBM 1000VA LCD Tower UPS (100 V) | 53961JX | 6664 |
IBM 1000VA LCD Tower UPS (120 V) | 53961AX | 6663 |
IBM 1000VA LCD Tower UPS (230 V) | 53961KX | 6665 |
IBM 1500VA LCD Tower UPS (100 V) | 53962JX | 6667 |
IBM 1500VA LCD Tower UPS (120 V) | 53962AX | 6666 |
IBM 1500VA LCD Tower UPS (230 V) | 53962KX | 6668 |
IBM LCD UPS Network Management Card (optional) | 46M4110 | 6145 |
IBM LCD UPS Environmental Monitoring Probe (optional) | 46M4113 | 6146 |
- An accessory kit, containing the following items:
- Serial cable (3.7 m (12 ft))
- USB cable
- Remote emergency power-off (REPO) connector
- A documentation kit, containing the following items:
- Warranty flyer
- Important Notices Manual
- Documentation CD
- Software CD, which contains IBM UPS Manager power management software
Description | Part number | Supplied line cord |
---|---|---|
IBM 1000VA LCD Tower UPS (100 V) | 53961JX | IEC 320 C13 to JIS C-8303 2.8 m |
IBM 1000VA LCD Tower UPS (120 V) | 53961AX | IEC 320 C13 to NEMA 5-15P 2.8 m |
IBM 1000VA LCD Tower UPS (230 V) | 53961KX | None (see Table 3.) |
IBM 1500VA LCD Tower UPS (100 V) | 53962JX | IEC 320 C19 to JIS C-8303 2.5 |
meters
IBM 1500VA LCD Tower UPS (120 V)| 53962AX| IEC 320 C13 to NEMA 5-15P 2.8
meters
IBM 1500VA LCD Tower UPS (230 V)| 53962KX| None (see Table 3.)
The 230 V models (1KX and 2KX) do not ship with line cords. Table 3 lists the
compatible 230 V line cords from IBM, which are suitable for models 53961KX
and 2KX; however, other customer ordered line cords can be used.
Table 3. Line cords for 230 V models (models 53961KX and 2KX)
230V line cords – 2.8 m line cords | Part number |
---|---|
European 10A line C13 to CEE 7/7 (2.8 m) | 39Y7917 |
Denmark 10A line C13 to DK2-5A (2.8 m) | 39Y7918 |
Switzerland 10A line C13 to SEV 1011 (2.8 m) | 39Y7919 |
Israel 10A line C13 to SI 32 (2.8 m) | 39Y7920 |
Italy 10A line C13 to CEE 7/7 (2.8 m) | 39Y7921 |
South Africa 10A line C13 to SABS 164/1 (2.8 m) | 39Y7922 |
United Kingdom 10A line C13 to BS 1363 (2.8 m) | 39Y7923 |
Australia/NZ 10A line C13 to SAA-AS C112 (2.8 m) | 39Y7924 |
Korea 7A line C13 to KETI 15A/250 V (2.8 m) | 39Y7925 |
India 6A line C13 to Fig 68 (2.8 m) | 39Y7927 |
China 6A line C13 to GB 2099.1 (2.8 m) | 39Y7928 |
Taiwan 10A/125 V C13/CNS 10917 (2.8 m) | 81Y2374 |
Taiwan 10A/250 V C13/CNS 10917 (2.8 m) | 81Y2375 |
Brazil 10A/250 V C13 to NBR 14136 (2.8 m) | 69Y1988 |
Argentina 10A line C13 to IRAM 2063 (2.8 m) | 39Y7930 |
230V line cords – 4.3 m line cords | Part number |
Europe 10A/250 V C13 / CEE 7/7 (4.3 m) | 81Y2376 |
United Kingdom 10A/250 V C13 / BS 1363A (4.3 m) | 81Y2377 |
China 10A/250 V C13 / GB2099.1 (4.3 m) | 81Y2378 |
South Africa 10A/250 V C13/ SANS 164-1 (4.3 m) | 81Y2379 |
Italy 10A/250 V C13/ CEI 23-16 (4.3 m) | 81Y2380 |
Israel 10A/250 V C13/ SI 32 (4.3 m) | 81Y2381 |
Denmark 10A/250 V C13/SB107-2-DI (4.3 m) | 81Y2382 |
Australia 10A/250 V C13/ AS/NZS 3112/2000 (4.3 m) | 81Y2383 |
Argentina 10A/250 V C13/ IRAM 2073 (4.3 m) | 81Y2384 |
Korea 12A/250 V C13/KSC 8305 (4.3 m) | 81Y2385 |
India 10A/250 V C13/IS 6538 (4.3 m) | 81Y2386 |
Brazil 10A/250 V C13/ NBR 14136 (4.3 m) | 81Y2387 |
Taiwan 10A/125 V C13/CNS 10917 (4.3 m) | 81Y2388 |
Taiwan 10A/250 V C13/CNS 10917 (4.3 m) | 81Y2389 |
Switzerland 10A/250 V C13/SEV 1011 (4.3 m) | 81Y2390 |
Features
The IBM 1000VA and 1500VA LCD Tower UPS offerings include the following features and capabilities:
-
Compact tower chassis.
-
Energy efficient at over 95% at 100% load.
-
Offers eight output power receptacles split across two load segments.
-
Offers an LCD display that provides intuitive, at-the-rack management and monitoring capabilities that supports nine languages:
- English
- French
- German
- Spanish
- Russian
- Korean Japanese Simplified Chinese Traditional Chinese
-
Includes intelligent IBM UPS Manager software that enhances control and manageability.
-
Compliant with IPv6 for future-proofing IP addressing and security.
-
Intelligent load segments allow for independent control of two sets of output receptacles. You can reboot equipment, manage sequential shut downs and start ups, and reserve battery run time for the most essential equipment.
-
Integrates with IBM Systems Director Active Energy Manager for power and thermal trending analysis and management.
-
Supports an optional network management card (part number 46M4140) for enhanced UPS monitoring and control.
-
Allows dual channel communication through the USB port and an optional Network Management Card at the same time, which is an effective redundancy feature that maximizes communications flexibility.
-
Includes a Remote Emergency Power Off (REPO) port to remotely power off the UPS unit to prevent battery operation during a power failure.
Requires a 20A single-phase circuit. -
Includes hot swap batteries for maximum uptime, availability, and ease of maintenance.
-
Supports an optional Environmental Monitoring Probe (part number 46M4113) for thermal management requirements (temperature and humidity), which requires that the Network Management Card be installed.
-
Uses Advanced Battery Management (ABM) three-stage charging technology, which significantly extends battery service life and optimizes recharge time. The three stages are:
- The battery is quickly charged to 90% to make sure the UPS is prepared for the next outage.
- ABM finishes charging the battery with a more moderate float charge.
- After the battery is charged, ABM turns the charger off, preventing the batteries from being overcharged.
Specifications
Table 4 lists the specifications for the IBM 1000VA and 1500VA LCD Tower UPS
models.
Table 4. Specifications
Specification| IBM 1000VA
LCD Tower UPS (100 V)
| IBM 1000VA
LCD Tower UPS (120 V)
| IBM 1000VA
LCD Tower UPS (230 V)
| IBM 1500VA
LCD Tower UPS (100 V)
| IBM 1500VA
LCD Tower UPS (120 V)
| IBM 1500VA
LCD Tower UPS (230 V)
---|---|---|---|---|---|---
IBM part number| 53961JX| 53961AX| 53961KX| 53962JX| 53962AX| 53962KX
VA/Watts rating| 1000 VA / 750 W| 1500 VA / 1000 W
Nominal output voltage (VAC)| 100 VAC| 120 VAC| 230 VAC| 100 VAC| 120 VAC| 230
VAC
Load groups| Two load groups (load segments): Two outlets in load group 1, six
outlets in load group 2
Output connections| Eight NEMA 5- 15R| Eight NEMA 5- 15R| Eight IEC 320 C13|
Eight NEMA 5- 20R| Eight NEMA 5- 15R| Eight IEC 320 C13
Input
Nominal input voltage| 100 VAC| 120 VAC| 230 VAC| 100 VAC| 120 VAC| 230 VAC
Input frequency (auto sensing)| 50/60 Hz +/- 3 Hz
Input connection type| IEC 320 C14| IEC 320 C14| IEC 320 C14| IEC 320 C20| IEC
320 C14| IEC 320 C14
Supplied Input cords| IEC 320 C13 to JIS C-8303 2.8
m
| IEC 320 C13 to NEMA 5-15P
2.8 m
| None (see Table 3.)| IEC 320 C19 to JIS C-8303 2.5
m
| IEC 320 C13 to NEMA 5-15P
2.8 m
| None (see Table 3.)
Input voltage range, mains operations| 84 – 121 V| 97 – 145 V| 160 – 286 V| 84
– 121 V| 97 – 145 V| 160 – 286 V
Batteries
Typical backup times| See Table 5| See Table 6
Battery type| Valve Regulated Lead Acid (VRLA) – maintenance-free, sealed,
leak-proof
Optional External Battery Pack| No| No| No| No| No| No
Typical recharge time| 4 hours to 90% charge from a UPS/battery discharge of
50% rated load
Table 5 lists the expected period that the IBM 1000VA LCD Tower UPS models will operate solely on batteries. Table 5. IBM 1000VA LCD Tower UPS runtime chart
Load (%) | Load (VA) | Load (Watts) | Run time (minutes) |
---|---|---|---|
25 | 250 VA | 188 W | 25 |
50 | 500 VA | 375 W | 15 |
75% | 750 VA | 573 W | 7 |
100% | 1000 VA | 750 W | 6 |
Table 6 lists the expected period that the IBM 1500VA LCD Tower UPS models will operate solely on batteries. Table 6. IBM 1500VA LCD Tower UPS runtime chart
Load (%) | Load (VA) | Load (Watts) | Run time (minutes) |
---|---|---|---|
25 | 375 VA | 255 W | 36 |
50 | 750 VA | 510 W | 15 |
75% | 1125 VA | 750 W | 9 |
100% | 1500 VA | 970 W | 6 |
Note: Battery backup times are approximate and may vary with equipment, configuration, battery age, and temperature. The IBM 1000VA and 1500VA LCD Tower UPS models do not support Extended Battery Modules (EBMs).
Physical specifications
- Height: 246 mm (9.7 in.)
- Width: 160 mm (6.3 in.)
- Depth: 436 mm (17.2 in.)
- Weight: 1000VA models: 14 kg (32 lb); 1500VA models: 19 kg (42 lb)
Operating environment
The IBM 1000VA and 1500VA LCD Tower UPS models are supported in the following environment:
- Temperature (operation): 0 to 40 °C (32 to 104 °F)
- Relative humidity: 5 to 95%
- Maximum altitude (operation): 3,000 m (10,000 ft)
Warranty
The IBM 1000VA and 1500VA LCD Tower UPS models have a three-year limited warranty. Optional features have a one-year warranty
Front panel controls
With a bright and easy-to-navigate panel that provides configurability and
displays important status information, the IBM 1000VA and 1500VA LCD Tower UPS
models are easy to manage and an ideal solution for standardization across the
global enterprise. Runtime, load, and other vital information and
troubleshooting are also displayed.
Figure 2 shows the front panel of the UPS.
Figure 2. Front panel (showing System Status)
The following functions are available on the control panel:
- System status: Displays the battery status, load percentage, output power, output voltage and frequency, mode, and notice or alarm status.
- Alarm history: Displays the alarm history for the 50 most recent events.
- Meters: Displays the output watts VA, current, power factor, voltage, frequency, input voltage, input frequency, battery voltage, and percentage charged.
- Control screens: Displays the battery test, reset error state, configure load segments, and restore settings.
- Model information: Displays the machine type, model, and serial number of the unit, and the firmware level of the UPS, including the optional
- Network Management Card’s firmware level and IP address, if installed.
- Configuration: Allows you to change up to 17 user settings with minimal navigation.
The buttons have the following functions:
- Escape (X): Press this button to return to the previous menu without running a command or saving any changes.
- Down ( ): Press this button to scroll down to the next menu option.
- OK: Press this button to select the current menu or option.
- On/off: Press this button to turn on the UPS. Press and hold this button for 3 seconds to turn off the UPS.
On some panels, the OK button has an additional function if you press and hold the button longer than 1 second:
- On the User Setting panels, this function saves the displayed setting.
- On the Meter and Notice/Alarm panels, this function locks the panel (that is, it prevents the panel from returning to its default after timeout). A locked panel displays a small key image near the status icon. To unlock the panel, press any button to perform its usual function.
Rear panel
Figure 3 shows the rear panel of the 230 V models of the IBM 1000VA LCD Tower UPS (53961KX) and IBM 1500VA LCD Tower UPS (53962KX).
Figure 3. Rear panel of the 230 V models of the IBM 1000VA LCD Tower UPS
(53961KX) and IBM 1500VA LCD Tower UPS (53961KX)
Figure 4 shows the rear panel of the 120 V models of the IBM 1000VA LCD Tower
UPS (53961AX) and IBM 1500VA LCD Tower UPS (53962AX). The 100 V models (1JX
and 2JX) look similar, although the IBM 1500VA LCD Tower UPS (100 V) 53962JX
has an IEC 320 C20 input and eight NEMA 5-20R outputs.
Figure 4. Rear panel of the 120 V models of the IBM 1000VA LCD Tower UPS (53961AX) and IBM 1500VA LCD Tower UPS (53962AX)
Network Management Card
The IBM 1000VA and 1500VA LCD Tower UPS models also come equipped with a
communication bay for the installation of an optional Network Management Card
(46M4110). The Network Management Card provides convenient, over the network
UPS remote monitoring and management through a standard web browser. Figure 5
shows the IBM LCD UPS Network Management Card (NMC).
Figure 5. IBM LCD UPS Network Management Card (NMC)
The IBM LCD UPS Network Management Card:
- Allows simultaneous shutdown of protected servers
- Allows configuration of automatic email messages in response to UPS alarms and to transmit periodic reports (see Figure 6)
- Allows control of UPS on/off switching with a web browser
- Allows adjustment and control of load segments through the HTML interface, including sequential starting of the installation and optimization of backup time by shutting down non-priority systems
- Allows protection by using an encrypted password
- Allows protection by using a secure SSL connection
- Allows log storage in the nonvolatile memory
- Allows card firmware updates through the network
- Allows fast Ethernet 10/100 Mbps compatibility with auto-negotiation on the RJ-45 connector
- Allows recording of events and measurements in the card log
- Has a humidity/temperature/dry contact sensor (optional EMP)
- Has support for IPv6 Can be installed while the UPS is online maintaining the highest system availability
Figure 6 shows the Network Management Card UPS properties window.
Figure 6. IBM LCD UPS Network Management Card (NMC) UPS properties window
IBM UPS Manager software
The UPS comes with the IBM UPS Manager software. The management software
provides up-to-date graphics of UPS power and system data and power flow. It
also gives you a complete record of critical power events, and notifies you
about important UPS or power information. If there is a power outage and the
UPS battery power becomes low, the software can automatically shut down the
system to protect the data before the UPS shutdown occurs.
Figure 7 shows normal operating using the IBM UPS Manager. The input voltage
is 122 V, which is within the acceptable range, and is shown in the left pane.
The output voltage of the UPS is 121 V and is also within the acceptable
range. The battery is in “floating” mode, which is the second stage of the
Eaton Advanced Battery Management (ABM) three-stage charging technology.
Figure 7. IBM UPS Manager normal status window
Figure 8 shows that the utility power supply has failed and that the UPS is
now operating on battery. The UPS Manager software indicates that there is 10
minutes of battery time available based on the current load.
Figure 8. IBM UPS Manager warning status window
Figure 9 shows the event notification window where you can configure how you
(and other users) want to be notified when certain events occur.
Figure 9. Event Notification window
IBM Environmental Monitoring Probe
The Environmental Monitoring Probe (EMP) (part number 46M4113) is used to
report local temperature and humidity values and make that information
available to management tools, such as IBM Systems Director Active Energy
Manager (AEM). The EMP connects to the UPS via the Network Management Card.
The EMP is shown in Figure 10.
Figure 10. IBM Environmental Monitoring Probe (EMP)
The Environmental Monitoring Probe has the following characteristics:
- It connects to the Network Management Card (NMC) settings/sensor connection.
- Its temperature and humidity thresholds are easily set to trigger alarm notifications or shut down the protected system.
- Its status can be monitored from the IBM Systems Director AEM or from the Network Management Card web interface.
- It measures temperatures between 0 and 80°C (32 and 176°F) with an accuracy of ±1°C.
- It measures relative humidity between 10 and 90% with an accuracy of ±5%.
- It can be located away from the UPS by using a CAT5 network cable (up to 20 m (65.6 ft)).
- Its user-selectable alarm thresholds enable you to define acceptable temperature or humidity limits.
- It allows email notification through SMTP.
Figure 11 shows information retrieved from an EMP using the NMC web interface.
Figure 11. Environmental Monitoring Probe data as viewed from the Network Management Card web interface
IBM Systems Director Active Energy Manager
IBM Systems Director Active Energy Manager (AEM) provides an array of new
features that allow power and thermal trending analysis for improved power
management. AEM collects power information for each device attached to an IBM
UPS, presenting a more complete view of energy usage within the data center.
The IBM Systems Director Active Energy Manager (AEM) helps:
- Collect power information from each device attached to an IBM UPS, thus presenting a more complete view of energy usage.
- With server consolidation plans, because of the increased server and rack power densities that have driven the requirement for advanced power management solutions.
- In combination with the optional Environmental Monitoring Probe, AEM enables cross-platform power and thermal trending analysis for improved power management. This configuration allows IT and facility managers to manage data centers for optimal energy efficiency, migrate workloads to eliminate hot spots, and transfer work from underutilized systems to conserve energy.
Related publications
For more information about this topic, refer to these documents:
-
IBM US Product Announcement
http://ibm.com/common/ssi/cgi- bin/ssialias?infotype=dd&subtype=ca&&htmlfid=897/ENUS110-210 -
IBM System x tower UPS product page
http://www-03.ibm.com/systems/x/options/rackandpower/ups.html -
IBM 1000VA and 1500VA LCD Tower UPS Installation and Maintenance Guide
http://ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5085920 -
Network Management Card User Guide
http://ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5085199 -
IBM System x Configuration and Options Guide
http://ibm.com/support/entry/portal/docdisplay?lndocid=SCOD-3ZVQ5W
Related product families
Product families related to this document are the following:
- Uninterruptible Power Supplies
Notices
Lenovo may not offer the products, services, or features discussed in this
document in all countries. Consult your local Lenovo representative for
information on the products and services currently available in your area. Any
reference to a Lenovo product, program, or service is not intended to state or
imply that only that Lenovo product, program, or service may be used. Any
functionally equivalent product, program, or service that does not infringe
any Lenovo intellectual property right may be used instead. However, it is the
user’s responsibility to evaluate and verify the operation of any other
product, program, or service. Lenovo may have patents or pending patent
applications covering subject matter described in this document. The
furnishing of this document does not give you any license to these patents.
You can send license inquiries, in writing, to:
Lenovo (United States), Inc.
8001 Development Drive
Morrisville, NC 27560
U.S.A.
Attention: Lenovo Director of Licensing
LENOVO PROVIDES THIS PUBLICATION ”AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER
EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some
jurisdictions do not allow disclaimer of express or implied warranties in
certain transactions, therefore, this statement may not apply to you.
This information could include technical inaccuracies or typographical errors.
Changes are periodically made to the information herein; these changes will be
incorporated in new editions of the publication. Lenovo may make improvements
and/or changes in the product(s) and/or the program(s) described in this
publication at any time without notice.
The products described in this document are not intended for use in
implantation or other life support applications where malfunction may result
in injury or death to persons. The information contained in this document does
not affect or change Lenovo product specifications or warranties. Nothing in
this document shall operate as an express or implied license or indemnity
under the intellectual property rights of Lenovo or third parties. All
information contained in this document was obtained in specific environments
and is presented as an illustration. The result obtained in other operating
environments may vary. Lenovo may use or distribute any of the information you
supply in any way it believes appropriate without incurring any obligation to
you.
Any references in this publication to non-Lenovo Web sites are provided for
convenience only and do not in any manner serve as an endorsement of those Web
sites. The materials at those Web sites are not part of the materials for this
Lenovo product, and use of those Web sites is at your own risk. Any
performance data contained herein was determined in a controlled environment.
Therefore, the result obtained in other operating environments may vary
significantly. Some measurements may have been made on development-level
systems and there is no guarantee that these measurements will be the same on
generally available systems. Furthermore, some measurements may have been
estimated through extrapolation. Actual results may vary. Users of this
document should verify the applicable data for their specific environment.
© Copyright Lenovo 2022. All rights reserved.
This document, TIPS0800, was created or updated on January 18, 2011.
Send us your comments in one of the following ways:
- Use the online Contact us review form found at: https://lenovopress.lenovo.com/TIPS0800
Send your comments in an e-mail to: comments@lenovopress.com
This document is available online at https://lenovopress.lenovo.com/TIPS0800.
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo
in the United States, other countries, or both. A current list of Lenovo
trademarks is available on the Web at
https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other
countries, or both:
Lenovo®
System x®
Other company, product, or service names may be trademarks or service marks of
others.
References
- IBM Support
- IBM Support
- IBM Support
- IT Infrastructure | IBM
- Uninterruptible Power Supplies > Lenovo Press
- IBM 1000VA and 1500VA LCD Tower UPS Product Guide (withdrawn product) > Lenovo Press
- Copyright and Trademark Information | Lenovo US | Lenovo US
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>