Thermometer
TM 705
medicine GmbH
41468 NEUSS, GERMANY.
SAFETY INFORMATION
Important notes! Be sure to keep it!
Read the instruction manual carefully before using this device, especially the
safety instructions, and keep the instruction manual for future use. Should
you give this device to another person, it is vital that you also pass on
these instructions for use.
The thermometer contains small parts that could be swallowed by children. Do
not let children handle the thermometer without adult supervision.
Only use the thermometer for measuring body tempera- ture under the tongue
(oral), in the armpit (axillary), or in the anus (rectal). Do not use the
thermometer in the ear.
Do not place the thermometer near extreme heat. There is a danger of the
explosion of the battery! The device must be tested for accuracy (calibrated)
after 2 years. Please send the complete device to the service centre.
If the thermometer is not going to be used for a long period, remove the
battery.
Do not shake, bend or tap the thermometer. Do not drop it. It is not shock-
resistant.
Protect the device from direct sunlight, extremely high or low temperatures,
high humidity, dirt, and dust.
Do not open up the device. If a fault occurs, please do not try to repair the
unit yourself. Discontinue further use of the unit. Contact your dealer and
only have repairs carried out by the service.
The device complies with the EN 60601-1-2 standard for electromagnetic
compatibility. It is subject to particular precautions in regard to
electromagnetic compatibility. Please note, that portable and mobile HF
communication systems may interfere with this unit. Please check the appendix
for more details on this.
WARNING! Please ensure that polythene packing is kept away from the
reach of children! Risk of suffocation!
Remove/insert battery
The medicine TM 705 thermometer is ready to use out of the package as the
battery is already pre-inserted. However, if after a certain period of
operation, a battery symbol appears on the display, the battery must be
replaced. To do this, pull off cap 4 of the battery compartment and remove
the battery compartment about 10 mm from the thermometer.
Use a suitable tool, such as a ballpoint pen tip, to loosen the button cell
battery carefully. Insert the new button cell battery with the “+” symbol
pointing upwards. Slide the battery compartment back into the thermometer.
Close the battery compartment again with the cap.
Change the unit of measure
You can measure the temperature at ° Celsius or ° Fahrenheit. Please proceed as follows to select the unit of measure:
- The device has to be switched off.
- Press and hold the ON/OFF button for approx. 4 seconds to change the current setting.
- The actual selected unit of measure ( °C or °F ) appears in the upper right corner of the display.
Use
Press the ON/OFF button to switch the unit on. All display symbols will
appear shortly and a signal tone will be emitted, followed by the last
measured temperature. If the temperature is below 32°C (90°F), “Lo” is
displayed – if the temperature is above 42,9°C (109.9°F), “ Hi ” is
displayed. The Medisana thermometer TM 705 is now ready to take a
temperature reading. Position the sensor tip in oral, axillary or rectal
position:
ORAL READINGS: Place the sensor tip of the thermometer under the tongue
and close your mouth. Breathe through your nose while taking the reading in
order to avoid inaccurate results. RECTAL READINGS: Many patients find
rectal measurement uncomfortable, but it delivers precise results. To quickly
and reliably determine body temperature, carefully insert the sensor tip
approx. 1 cm into the rectum. ARMPIT READINGS:
Wash the armpit before taking a reading. Insert the tip of the thermometer
into the armpit. Lower the arm and press it lightly against the body while
the reading is being taken.
The thermometer will now automatically begin to take a reading. During the
reading, the “°”-sign flashes constantly. After the reading, multiple tones
will be emitted for approx. 10 seconds and the measurement result will be
displayed. If you continue to measure even after the signal tones have been
emitted, the readings will get more accurate. If you measure the body
temperature on the armpit, the measurement duration should be at least 10
minutes in order to get a reliable result. If the reading is > 37,8°C (100°F),
the thermometer will indicate fever alarm by announcing multiple beep sounds
(short beeps). The thermometer will switch off automatically ten minutes after
taking the reading. To prolong the life of the battery, however, you should
switch off the thermometer manually by pressing the ON/OFF button.
FEVERLINE INDICATING TECHNOLOGIE
At the completion of each measurement, the triangular arrow on the display
will indicate according to different temperature ranges.
Triangular arrow explains:
Note: If the displayed temperature is below 35,8°C ( 96,4°F), the triangle arrow will not be displayed.
Cleaning and disinfection
The medicine TM 705 thermometer is waterproof and easy to clean and disinfect. Before and after each measurement, clean the thermometer with a cloth soaked in a mild alcohol solution. You can also place the thermometer in a suitable disinfectant solution. Your specialist dealer will gladly recommend suitable cleaning products and advise you regarding their use. Do not ever boil the thermometer!
Instructions for disposal
Do not throw this thermometer away in ordinary household waste. Consumers are legally obliged to bring all used batteries, rechargeable or otherwise, whether they contain harmful substances or not, to a collection site in their community so that they can be transferred to the proper channels for disposal. Remove the batteries before disposing of the device. Do not throw used batteries in ordinary household waste, but instead only with other hazardous waste or at a battery collecting station at a specialist shop. Contact your local authority or dealer regarding disposal.
Technical information
Name and model: | medisana thermometer TM 705 |
---|---|
Voltage supply: | Button cell 1,5V (type GP-192 or LR 41) |
Battery life: | approx. 200 hours |
Range of measurement: | 32,0°C – 42,9°C (90.0°F – 109.9°F) |
Measurement accuracy: | ± 0,1°C / 0.2°F in the region of 35,5°C – 42°C / 95.9°F |
– 107.6°F; outside the above region: ± 0,2°C / 0.4°F (deviation from actual
body temperature at ambient temperature 18°C – 28°C / 64.4°F – 82.4°F)
Memory:| The last measured value will automatically
be saved
Operating conditions:| 5°C – 40°C (41°F – 104°F), rel. humidity < 85 %
Storage and transport conditions:| -10°C – 55°C (14°F – 131°F), rel. humidity
< 95 %
Ingress Protecting rating:| IP 27
Dimensions (L x W x H):| approx. 13,9 x 2,2 x 1,3 cm
Weight:| approx. 13 g (incl. battery)
Item no.| 77042
EAN Code:| 40 15588 77042 5
---|---
| Device corresponds to protection class B
---|---
| Manufacturer
| Manufacture date
| Read the instructions for use carefully.
| Batch number
The CE marking refers to the EU Directive 93/42/EEC. The design and manufacture were carried out in compliance with the following European standards: EN 80601-2-56 (Medical thermometers), EN ISO 15223, EN 60601-1 (Electrical safety for medical devices). Electromagnetic compatibility: The device meets the requirements of EN 60601-1-2 for electromagnetic compatibility. Contact medisana to request details about these measurement data.
Warranty and repair conditions
In case of a warranty claim, please contact your specialist shop or take the thermometer directly to the service point. Should you have to return the device, please state the defect and enclose a copy of the purchase receipt or invoice.
77042 11-2020 Ver.1.2
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>