SPECIFICATION

  • PRODUCT: CHI LIFE UV Lamp (CL1008)
  • RATED VOLTAGE: 110-130V
  • POWER: 40W
  • FREQUENCY: 50/60 Hz
  • NM WAVELENGTHS: 253.7
  • TIMER: 30/60/120 Mins

UV LAMP STERILIZATION PRINCIPLE – This UV-C lamp operates at 254nm which is within the wavelength proven to destroy bacteria and viruses by altering the DNA of the cells harmful contaminants, even microorganisms naked to the human eye.
SERVICE LIFE – 6,000 hours
USE RANGE – Air sterilization for indoor or enclosed spaces

SPACES PRODUCT DESCRIPTION:

  1.  This product is an indoor air germicidal lamp using a UV-C light source.
  2.  This product incorporates three movable side covers to control ultraviolet light exposure. They can be kept open when there are no people around, or all three side covers can be closed when people are nearby. Fans built inside the unit circulate the air in the room so that it passes through the germicidal chamber of the purifier to be decontaminated from microbes.

SAFETY WARNINGS:

  1.  This product is limited to air sterilization indoors or enclosed spaces. Do not operate with covers open in public spaces.
  2.  UV-C light is harmful to the eyes, skin, plants and animals. Do not expose UV-C light to people, plants or pets. Do not stare at the UV-C light.
  3.  KEEP AWAY FROM CHILDREN. DO NOT ALLOW CHILDREN NEAR THE DEVICE OR ALLOW CHILDREN TO TOUCH OR PLAY WITH THE DEVICE.
  4.  This product is not waterproof. Do not expose to rain or wash with water or other liquids.
  5.  Make sure this machine works at the voltage required by this product.

GENERAL INFORMATION

OPERATION INSTRUCTIONS

  1.  Press the “Power On/Off” button. A red indicator light will turn on, and a “welcome” voice prompt will activate.
  2.  Press the “Power On/Off” button once again and a voice prompt will activate stating that the device will automatically turn on after 30 seconds. Please close the covers or open the covers and exit the room within the 30 seconds. “The lamp will turn on after 30 seconds.
  3.  Press the timer button to select 30 minutes, 1 hour or 2 hours. The unit will function for the period of time selected.
  4.  Press the “Power ON/Off” button to turn off the unit if it is operating.
  5.  Press the Fan button to turn the fan on or off.
  6.  Press the Timer button 4 (four) times to place the unit on standby mode.

TIMING BUTTON

  1.  First press the “Power On / Off” button, the red indicator light is on, and the voice prompt “Welcome to use a microcomputer ultraviolet germicidal lamp”: Then press the “Timer” key once, and the blue indicator light flashing corresponding to the “30-minute timer” voice guide (The indicator red light is always on) Press the “Power On / Off” button again, and you can hear voice prompt “UV disinfection and sterilization function is enabled, it will automatically turn on after 30 seconds, please close the covers or stay away”, and the fans and light will turn on at the same time after the voice prompt is completed. At this time, the working time of the UV light and fans is 30 minutes. When the 30 minutes is complete, the voice prompt” Thank you for your use, please unplug the power plug” which means this machine is turned off.
  2.  First press the “On / Off” key, the red indicator light is on, and the voice prompt “Welcome to use a microcomputer ultraviolet germicidal lamp”; then press the “Timer” key twice, and the voice prompt “Timer 1 hour” blue and green lights flash at the same time (The red indicator light is always on, then press the “Power On / Off” button, the voice prompt “UV disinfection and sterilization function is enabled, it will automatically turn on after 30 seconds, please close the covers or stay away.” 30 seconds after the voice prompt is completed, the fans and light are turned on at the same time: At this time, the working time of the lamp and fans will be 1 hour. When the hour is completed, a voice prompt “Thank you for your use, please unplug the power plug”. The light and fans are all turned off.
  3.  First press the “Power On / Off” button, the red indicator light is on, and the voice prompt “Welcome to use a microcomputer ultraviolet germicidal lamp”; then press the “Timer” button three times, the voice prompt is “Timed 2 hours”, blue, green and red indicator lights flashing at the same time: Press the “Power On / Off” key again, and the voice prompt “UV disinfection and sterilization function is enabled, automatically turn on after 30 seconds, please close the covers or stay away”. After the voice prompt is completed, the fans and the light are turned on at the same time. At this time, the working time of the lamp and fans will be 2 hours. When the 2 hours are completed, the voice prompt “Thank you for your use, please unplug the power plug”. The lamp and fan are all turned off.
  4.  Press the “Timer” button four times in succession, the timer function is canceled, and the voice prompt “Timer Cancel” is displayed. This UV germicidal light returns to standby status. The fans will turn on or off when you hear the voice prompts “fan on” and “fan off”.

REMOTE CONTROL:

  1.  The operation of the remote is the same as the controls on the panel.
  2.  The operation of the “Fan” button is the same as the panel control.
  3. How to use the “open” button: When the “Power On/Off” button is turned on (the red indicator light is on), press the ”Open” button once, and a voice prompt will state that the unit sterilization function will automatically turn on after 30 seconds. This operates the same as pressing the On/Off button on the panel the second time. Please close the hood and exit the room.
  4.  When the “Power On / Off” button is on (the red indicator light is on), press the “30 minutes” button once to activate the 30-minute timer.
  5.  Press the “1 hour” button to activate the 1 hour timer.
  6.  Press the “2 hours” button to activate the 2 hour timer.

WARRANTY

How Long Does The Warranty Last? One (1) year from the date of purchase.
Limitations. (A) THE DURATION OF ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, GOOD AND WORKMAN-LIKE PERFORMANCE OF SERVICE, OR OTHERWISE, ON THIS PRODUCT ARE LIMITED TO THE DURATION OF THE EXPRESS WARRANTY SET FORTH ABOVE WHICH IS ONE (1) YEARS FROM THE DATE OF PURCHASE. (B) CHI SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES THAT ARISE OUT OF THE INSTALLATION, USE, OR OPERATION OF ITS APPLIANCES OR OUT OF THE BREACH OF ANY EXPRESS OR IMPLIED WARRANTY. (C) APPLIANCES PURCHASED FROM ANY OUTLET OTHER THAN AN AUTHORIZED RETAILER NOT COVERED BY THIS WARRANTY. (D) ANY ALTERATION OR REMOVAL OF THE SERIAL NUMBER OR OTHER IDENTIFYING MARKS ON THE APPLIANCE OR PACKAGING WILL VOID THIS WARRANTY. (E) ANY USE OF THE APPLIANCE NOT IN COMPLIANCE WITH THE OWNER’S MANUAL WILL VOID THIS WARRANTY.

How to make a warranty claim.
SAVE YOUR ORIGINAL RECEIPT. Then Either:
(A) Return the appliance with the original receipt to the professional salon or professional salon chain from which it was purchased where the appliance may be exchanged at no charge, depending on the reseller’s exchange policy (terms and conditions may vary depending on store’s exchange policy);
or
(B) Contact Farouk Systems, Inc. Customer Service at 800-237-9175 if you have any questions regarding your tool. Send your tool, along with any completed warranty card that accompanied the tool at time of purchase, the original receipt indicating the location and date of purchase and a check or money order made payable to Farouk Systems, Inc. for $15 to cover shipping and handling, to the following address (United States Only: California residents are not required to send payment.):
Attention: Customer Service
Farouk Systems, Inc.
880 E. Richey Rd.,
Houston, TX 77073

WARNING:
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation Please take attention that changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals