TRIPLETT GSM050 Gas Leak Detector User Manual
- June 6, 2024
- TRIPLETT
Table of Contents
TRIPLETT GSM050 Gas Leak Detector
Introduction
Congratulations on your purchase of the Triplett GSM050 Gas Leak Detector. The
GSM050 detects the presence of propane or natural gases. Careful use of this
detector will provide years of reliable service.
Description
- Sensor
- Status Indicators
- ON/OFF Switch
- Lanyard
Specifications
Measurement ranges Propane: 500 to 6500 ppm; Natural gas:
1000 to 6500 ppm
Power 2 x ‘AAA’ 1.5V batteries; 200mA
consumption; 4 hour battery life
Operating conditions 50 to 122oF (10 to 50oC); < 95% RH non-
condensing
Storage conditions 41 to 131oF (5 to 55oC); < 95% RH (non
condensing)
Dimensions 7.1” Length; 0.8”: diameter” (180mm
length; 21mm diameter)
Weight 1.6 oz (46g)
Application
This device can be used to detect gas leaks from small liquid gas containers
such as camping cartridges, lighters, soldering torches, etc. This device is
not suitable for continuous operation, industrial use, or complex systems such
as heaters and ovens.
Safety
- Do not get the sensor wet. Avoid extreme dampness.
- Do not expose the device to high temperature, high humidity, or strong vibration.
- Avoid mechanical stress to the device. Do not touch the sensor.
- Clean with a soft, dry cloth or brush. Do not use liquid, abrasives, solvents, etc.
Battery Installation/Replacement
When the status indicators fail to light with the ON-OFF switch in the ON position, replace the two (2) ‘AAA’ batteries. Slide the battery compartment cover off (rear of the detector) to access the batteries. Replace the batteries observing polarity and close the compartment. Remove the batteries if the detector is to be stored for long periods of time.
Operation
Static Electricity
The metal conductor protruding from the back of the detector is used for
static tests. Before detecting a leak (and at a safe distance from the testing
area), touch the conductor with one hand and, at the same time with the other
hand, touch an earth grounded metal object such as a heater or cold water
pipe. If the user is statically discharged, the yellow indicator will light
for a short period. If there are strong charges present, gas detection
measurements should not be taken since discharges could ignite leaking gas.
Leak Detection
- Remove the protective sensor cap.
- Slide the ON/OFF switch to the ON position. The Red indicator will light and the audible tone will sound for a short period of time and then the Green indicator will light.
- Perform the static electricity test.
- Trace the sensor around the source of the suspected leak.
Indicators
- Yellow Used for static electricity tests.
- Red Lights when gas is detected (along with an audible beep).
- Green lights in clean ambient air
When Gas is Detected
When a leak is detected, the red indicator will light and an audible tone will
sound. Open all doors and windows. Avoid open fire and sparks, leave the room,
and do not operate any electrical switches (light switches, etc.). If
possible, turn off the gas supply. When the concentration of gas falls below
detectable limits, the red indicator and audible tone will no longer activate
when tests are taken. Note that false alarms are possible due to the presence
of aerosol sprays, tobacco smoke, etc.
Testing the Gas Leak Detector
Hold a gas lighter close to the sensor and allow the unlit lighter to leak a
small amount of gas. If the detector is working correctly, the red indicator
will light and the audible tone will sound. If the light and sound do not
activate, the batteries may be weak or the unit is defective.
Note on Liquefied Gases
Liquefied gases are heavier than air and therefore settle on the floor. For
this reason, the highest concentration of gas is close to the ground.
Warranty
Triplett / Jewell Instruments extends the following warranty to the original
purchaser of these goods for use. Triplett warrants to the original purchaser
for use that the products sold by it will be free from defects in workmanship
and material for a period of (1) one year from the date of purchase. This
warranty does not apply to any of our products which have been repaired or
altered by unauthorized persons in any way or purchased from unauthorized
distributors so as, in our sole judgment, to injure their stability or
reliability, or which have been subject to misuse, abuse, misapplication,
negligence, accident or which have had the serial numbers altered, defaced, or
removed. Accessories, including batteries are not covered by this warranty.
Copyright © 2021 Triplett
www.triplett.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>