KitchenAid KVUC600KSS Range Hood 30 Inch User Manual
- June 6, 2024
- KitchenAid
Table of Contents
W11548781A
DIMENSIONS
RANGE HOOD – 30″ (76.2 CM) AND 36″ (91.4 CM)
PRODUCT MODEL NUMBERS: KVUC600KSS and KVUC606KSS
WARNING: To reduce the risk of fire, electric shock, or injury to
persons, read the IMPORTANT SAFETY INSTRUCTIONS, located in
your appliance’s Owner’s Manual, before operating this appliance.
Electrical Requirements:
- A 120 V, 60 Hz, AC only, 15 A, fused electrical circuit is required.
- If the house has aluminum wiring, follow the procedure below:
Connect the aluminum wiring using special connectors and/or tools designed and
UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer’s recommended procedure.
Aluminum/copper connection must conform with local codes and industry accepted
wiring practices.
PRODUCT DIMENSIONS
|
---|---
CABINET DIMENSIONS
IMPORTANT:
Minimum distance “X”: 24″ (61.0 cm) to the electric cooking surface and 30″
(76.2 cm) to the gas cooking surface.
Suggested maximum distance “X”: 36″ (91.4 cm).
VENTING REQUIREMENTS
- The vent system must terminate to the outdoors.
- Do not terminate the vent system in an attic or other enclosed area.
- Do not use a 4″ (10.2 cm) laundry-type wall cap.
- Use metal vent only. A rigid metal vent is recommended.
- The length of the vent system and the number of elbows should be kept to a minimum to provide efficient performance.
For the most efficient and quiet operation:
- Use no more than three 90° elbows.
- Make sure there is a minimum of 24″ (61.0 cm) of straight vent between the elbows if more than 1 elbow is used.
- Do not install 2 elbows together.
- Use clamps to seal all joints in the vent system.
- The vent system must have a damper. If the roof or wall cap has a damper, do not use a damper supplied with the range hood.
- Use caulking to seal the exterior wall or roof opening around the cap.
- The size of the vent should be uniform.
Venting Methods
This range hood is factory set for venting through the roof or wall.
A 3¹⁄4″ x 10″ (8.3 cm x 25.4 cm) rectangular vent system is needed for
installation (not included). The hood exhaust opening is 3¹⁄4″ x 10″ (8.3 cm x
25.4 cm). The vent system can terminate either through the roof or wall. To
vent out of the top of the range hood and through a wall, a 90° elbow is
needed. See the “Install Range Hood” section of your Owner’s Manual for
details of installing the damper.
NOTE: Flexible vent is not recommended. A flexible vent creates
backpressure and air turbulence that greatly reduce performance.
Rear discharge
This range hood can be vented directly out the back using the 3¹⁄4″ x 10″ (8.3
cm x 25.4 cm) rectangular damper (supplied) along with a 3¹⁄4″ x 10″ (8.3 cm x
25.4 cm) rectangular vent system (not supplied). See the “Install Range Hood”
section of your Owner’s Manual for details of installing the damper.
Roof Venting | Wall Venting (top or rear discharge) |
---|
|
A. Roof cap
B. 3¹⁄4″ x 10″ (8.3 x 25.4 cm) rectangular metal vent| A. Wall cap
B. 3¹⁄4″ x 10″ (8.3 x 25.4 cm) rectangular metal vent
Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet
(meters) for each vent piece used in the system.
3¹⁄4″ x 10″ (8.3 cm x 25.4 cm) Vent System
Vent Piece
|
Equivalent Length
---|---
3¹⁄4″ x 10″ (8.3 cm x 25.4 cm) 90° elbow| 5.0 ft (1.5 m)|
3¹⁄4″ x 10″ (8.3 cm x 25.4 cm) flat elbow| 12.0 ft (3.7 m)|
3¹⁄4″ x 10″ (8.3 cm x 25.4 cm) wall cap| 0.0 ft (0.0 m)|
Example vent system
Maximum Recommended Length | = 35 ft (10.7 m) |
---|---|
1 – 90° elbow | = 5.0 ft (1.5 m) |
8 ft (2.4 m) straight | = 8.0 ft (2.4 m) |
1 – wall cap | = 0.0 ft (0.0 m) |
Length of 3¹⁄4″ x 10″ (8.3 cm x 25.4 cm) system | = 13.0 ft (3.9 m) |