OZDEM RAD322 Video Door Phone Installation Guide

June 6, 2024
OZDEM

Video Door Phone
Scientific Home
Scientific Life
OPERATING AND
INSTALLATION GUIDE

Version: RAD322RAR122
Please read this manual before using it and save it for future reference.

Technical parameters of outdoor station

Product Material aluminum alloy
Transmission Mode digital transmission
Working voltage DC12V
Operating temperature -20°C – +55°C
Operating current 60-80mA
Standby current 10-20mA
Installation Method wall mounting type
Installation Dimension 130x54x40mm

Technical parameters of Indoor unit

Working voltage DC12V
Call duration 120s
Call way two-way communication
Operating temperature -20°C— +55°C
Operating current 60-80mA
Standby current 10-20mA
Display Screen seven-inch color LCD screen
Resolution 800×480

Ringtones Selection on the monitor (7 ringtones cyclical selection):
When the monitor is on standby, press the talk button till the“BI” sound, then press the monitor button till the “BI” sound, the setting mode starts( for10 seconds, the indicator flashing), press the monitor button for ringtones cyclical selection. Press the talk button to confirm and exit.

Ring time/quantity selection on the monitor ( “dingdong” ring quantity for 3-10 times, other ringtones -example“beep”-ring time for 6-20 seconds ring):
When the monitor is on standby, press the talk button till the “BI” sound, then press the intercom call button till the “BI” sound, the setting mode starts( for 10 seconds, the indicator lamp flashing), press the monitor button for increasing ring quantity/time, press the unlock for decreasing the ring quantity/time. Press the talk button to confirm and exit. Unlocking time section on the monitor(2s-20s):
When the monitor is on standby, press the talk button till the “BI” sound, then press the unlock button till the “BI” sound, the setting mode starts( for 10 seconds, the indicator flashing), press the monitor button for increasing the unlock time2s-20s, press the unlock for decreasing the unlock time2s- 20s,(every press increase/decrease by one second). Press the talk button to confirm and exit.

Restore factory setting on the monitor: Press the talk button till the power on, a long beep will sound, the restore factory setting finishes.

4-wire villa intercom system diagram1

Standard Set Diagram(1 outdoor station for 1 indoor monitor):
OZDEM RAD322 Video Door Phone - indoor monitor

(4C: The diameter of the RVVP wire is 0.5mm square

Detailed connection diagram

OZDEM RAD322 Video Door Phone - diagram

Extension Connection Diagram

(1 outdoor station for max 4 indoor monitors):

(4C: The diameter of the RVVP wire is 0.5mm square)

Indoor monitor:

OZDEM RAD322 Video Door Phone - Indoor monitor

Notes for indoor monitor:
◆ CN1 is for power, the negative“-” and the positive“+”.
◆ The indoor monitor CN2 (audio、gnd、V+、video) is accordingly wired with the outdoor station CN1(audio、gnd、V+、video).
◆ J1 plugin when the outdoor station needs the power from the indoor monitor.
◆ J2 is a video jumper Pin, at the time of two or more indoor monitors connection, The J2 on the furthest indoor monitor needs plugin, the J2 on the other monitors is unplugged.
◆ J3 is a ringtone selection jumper Pin, at the time of two or more indoor monitors connection, the J3 on one of the monitors need a plugin, other monitors J3 is unplugged.

14 Master card function

  1. Add a new master card (00-04 indicates the label of 5 master cards, 00 is the first, 01 is the second…).
    In the setting mode:
    Press “” “7” (red light flashing, Bi — long ring), and then input 00-04 (if the blue light is on, it means that this number has a parent card. Press “” “*” to clear the card, and the green light flashes after clearing. At this point, you can add a parent card. If the green light indicates that this number has no master card, you can add master card), press “#” to exit back to set mode, and then press “#” to exit the setting.
  2. Delete all master cards
    In the setting mode:
    Press “*” “4” (red light flashes, Bi — long ring), and then enter 01 (Bi — long ring, red light stops flashing, and the mother card is deleted successfully). Finally, press “#’ to exit back to set mode,
    and then press ‘#” to exit the setting.
  3. Add user card with mother card
    The first time you swipe the card, BI- BI rings twice with a long front sound and a short back sound and opens the door. When you swipe the master card again within 5s, it will ring the Bi long
    sound — green light flashing and enter the automatic card adding state. At this point, you can add the user card, the third swipe master card, the Bi –Bi sound occurs, the front sound is long and the back sound is short, exit the setting, or automatic exit
    setting without operation in 10s.
    Note: add card to the master card, no card + password to open the door, each time swiping card directly open the door; If there is a duplicate card number when adding the card number, it will
    BiBi, indicating invalid.

15 Prompt sound effect )If input error, it will have BiBi prompt tone. If there is no operation in 40 seconds after entering the setting state, exit automatically and there is BiBi prompt tone. If the button is not pressed when it is not in the set state, it will exit automatically after 10 seconds. If under the card and password opening method, swipe card or fingerprint correctly and wait for password input. If no operation is done after 20 seconds, it will exit automatically with BiBi prompt tone.
Visitors call:
OZDEM RAD322 Video Door Phone - visitorsOZDEM RAD322 Video Door Phone - Monitoring Outdoor station:
1. The outdoor station display diagram

OZDEM RAD322 Video Door Phone - Outdoor station

No. Function Description No. Function Description
1 camera 5 card swiping coil
2 call button 6 password button
3 horn hole 7 microphone
4 nameplate 8 fingerprint head

Change management password

In the setting mode:
Press “” “3”, the red light flashes, enter 4-8 bit management passwords twice, at last press “#” to confirm(Bi — long ring, and the outdoor station exit to set mode directly), the password is modified successfully. (if the administrative password is 223456, the input method should be: press “” “3”, red light flashes, and press 223456+223456+#)
10)Restore ex-factory management password: If you forget to manage your password, please recharge the battery and press “#” button before the BiBiBiBiBi sound.
11)Set the opening time of the door machine In the setting mode: Press “” “1’ (red light flashes, Bi — long ringing), enter double digits (00-99) to indicate the opening time (issued Bi sound, red
light stops flashing), press “#” to exit the setting. If set to 05, the opening time is 5 seconds, and so on. Note that if set to 00, inducting one time is on and inducting again is off. (factory setting time default 2s).
12 Unlock button ) The unlock button is an external interface. The external switch should be connected with the unlock button. When the switch is pressed, the outdoor station has a green light and the lock will be open.
13 Turn on/off the buzzer function ) In the setting mode: a. Turn on the buzzer: press “
” “2” (red light flashes, Bi — long ring), press “0” “1” (Bi — long ring, red light stops flashing and set successfully), press “#” to exit the setting. b. Turn off the buzzer: press “” “2” (red light flashing, Bi — longing), press “0” “2” (Bi — long ring, red light stop flashing, setting successful), press “#” to exit the setting.
6)Automatically find the free position and add new users In the setting mode: Press “
” “9” (the system will automatically locate the free numbers to add users, green light flashing), Firstly swipe the
card (a Bi long ring when swiping the card indicates adding card successfully). Secondly add the fingerprint (when inputting fingerprint, Bi Bi Bi sound occurs and the last Bi will be a long ring, and the fingerprint successfully. Failure to add fingerprint if Bi Bi sound occurs). Thirdly adding the password (password is set to 4 to 8 passwords length. For setting a password, enter the password and press “#” to confirm. Adding the password successful by sending out the Bi – long ring). Finally, press “#” to exit the user settings, and the display shows a red light. You can then add another set of numbers after exiting, with the same pattern set as above. Or press “#” to exit the settings. Note: When you have 100 users, and you add a new user method with automatic look-up, the last user will be replaced.
7)Clear cards, passwords, and fingerprints In the setting mode: a. Clear all cards, passwords, and fingerprints: press “” “8” (red light flashes, Bi — long ring), and press “8” “8” (Bi — long ring, red
light stop flash) to indicate successful clearance, press “#” to exit back setting mode, and then press “#” to exit the setting. b. Delete a certain door card + password + fingerprint: press 000-099 (if the blue light is on, it means the bit has information, you can press “
” “” to clear the bit, and the green light flashes after clearing. If the green light is on, it means that there is no data on this bit, complete the function of deleting the card, and finally press “#” to return to the setting mode, and then press “#” to exit the setting). Or quit automatically after the 40s.
8)Restore factory Settings In the setting mode: Press “
” “8” (red light flash), press “9” “9” (Bi — long ring, and the outdoor station back to set mode), then the outdoor station restored factory settings.

OZDEM RAD322 Video Door Phone - fig5OZDEM
RAD322 Video Door Phone - fig6
2. Description of the outlet of the outdoor station

  1.  J1: Connection to Indoor monitor. audio/and /v+/video is respectively wired in red/blue/yellow/white.
  2.  J4: The power interface, and the mark “-” is the negative pole, and the mark “+” is the positive pole.
  3.  VR1: The horn potentiometer of the outdoor station. Turn it clockwise is up and turn it backward is down.
  4.  J2: Connection to the electric lock.
  5.  J3: Connection to the unlock button.
    3 .Operating instructions
  1. Storage
    Can save 100 cards, passwords and fingerprints can be set two ways to open the door: the first way is cards, passwords, or fingerprints. The second way is either a card with a password or a fingerprint with a password.
  2. Enter the setting mode:
    Press “#”, green light flashes for 3 times, make Bi sound, and press management password twice(123456+123456) and press “#” to make sure, then enter the setting mode, and the red light turns on. Can press “” to exit when input error. The factory management code is 123456.
    3)Set the door opening mode
    In the setting mode:
    Door opening method 1: Press “
    ” “0” (red light flashes), press “8” “1” (make Bi sound, red light stops flashing), and finally press “#” to exit setting (open the door by card, password or fingerprint).
    Door opening method 2: Press “” “0” (red light flashes), press “8” “2” (make Bi sound, red light stops flashing), and finally press “#” to exit setting (open the door by card and password or by
    fingerprint and password).
    4)Door opening method A. card + password: first swipe the card and make Bi sound, then the green light flashes for 3 times, and then enter the password. If no password is entered in the 20s, automatically exit with BiBi sound.
    B. Fingerprint + password: press fingerprint first, and Bi sound occurs if valid, then green light flashes for 3 times, and then enter a password. If no password is entered in the 20s, exit automatically
    with BiBi sound.
    C. Password opening: after entering the password, press “#” to confirm. If the password is valid, open the door with a long Bi sound, and the green light flashes 3 times. BIBI sound occurs if invalid.
    D. Card opening: when the opening is successful, make a Bi sound, and then the green light flashes three times.
    E. Fingerprint opening: when the opening is successful, make a sound, and then the green light flashes three times. Note: If invalid when inputting the password or using the card 3 times in 3 minutes, the
    a lock is locked for 60 seconds (the key and induction card are invalid).
    5)Add users In the setting mode :(000~099 represents the label of 100 users, 000 is the first, 001 is the second…). Press 000-099 (if the light is blue, it means that the bit has data. you can press “
    ” “” to clear the bit data, green light flashes after clearing, then you can add users. If green light flashes, which indicates the bit has no data, you can add card + code + fingerprint). Firstly swipe the card (an I long ring when swiping the card indicates adding card successfully). Secondly, add the fingerprint (when inputting fingerprint, Bi Bi Bi sound occurs and the last Bi will be a  long ring, and the fingerprint
    successfully. Failure to add fingerprint if BiBi sound occurs). Thirdly adding password (password is set to 4 to 8 passwords length. For setting a password, enter the password and press “#” to confirm. Add password successful by sending out the Bi – long ring. When setting the password, you can press the “
    ” key to cancel if you press the wrong key, and then re-enter the password, press “#” key
    to confirm). Finally, press “#” to exit the user number settings, and the display shows a red light. you can then add another set of numbers after exiting, with the same pattern set as above. Or press “#” to exit the settings.