Welcome
Thank you for purchasing this Furrion® Multi Zone Wall Thermostat. Before
operating your new product, please read these instructions carefully. This
instruction manual contains information for safe use, installation and
maintenance of the product.
Please keep this instruction manual in a safe place for future reference. This
will ensure safe use and reduce the risk of injury. Be sure to pass on this
manual to new owners of this product.
The manufacturer does not accept responsibility for any damages due to not
observing these instructions.
If you have any further questions regarding our products, please contact us at
support@furrion.com
About your Thermostat
Product Features
Your Multi Zone LCD thermostat is equipped with a liquid crystal display (LCD) to indicate the temperature set-point in Fahrenheit(°F)/Centigrade(°C) and fan speed. It is also equipped with LCD to indicate the system available operation modes.
NOTE : The available operation modes will be different depending on the system installed in your RV.
- Liquid Crystal Display with Blue Backlight and Mode Indicators
- Auto Fan
- Room Temperature Display
- Fahrenheit(°F)/Centigrade(°C) Display
- Sleep Mode
- LED Mood Light
- Time Program
Control Buttons
LCD Icons
Installation
What’s in the Box
Make sure you have all the following items included in the packaging. If any item is damaged or missing, contact your dealer.
– Thermostat x 1
– Instruction Manual x 1
– Warranty Card x 1
– Self-tapping Screw x 2
Thermostat Installation
-
Select a suitable location that is not under direct influence from light, sun or other heat sources.
-
Rotate the thermostat cover counterclockwise and pull out the base plate. (Fig. 1)
-
Use the base plate as a template and drill a hole on the vehicle wall. Extend the four wire cables from the cutout area. Refer to the cable tag label for each cable definition. (Fig. 2)
-
Fix the base plate on the wall using 2 screws. (Fig. 3)
NOTE : Make sure the base plate is not covering the hole and squeezing the thermostat cables. -
Connect the cables to thermostat. Rotate the thermostat clockwise until it clips into place. (Fig. 4 and Fig. 5)
Operation
Your Furrion wall thermostat has been preprogrammed with factory default settings. Review the settings below and adjust to your comfort level.
Turn On/Off the Thermostat
To turn On
Press button to turn on the thermostat. The thermostat LCD will be illuminated and the factory settings will be displayed on the LCD for first time use.
NOTE : The LCD will display the last setting if you have changed the parameters.
To turn Off
Press and hold button for 3 seconds to turn off the thermostat. Only the current room temperature will be displayed on the LCD.
Temperature Format
Simultaneously press both and buttons for 3 seconds to toggle the temperature format between Centigrade and Fahrenheit.
NOTE : ºF indicates Fahrenheit and ºC indicates Centigrade.
Operation Mode
After the thermostat is turned on, press MODE button repeatedly to toggle
through the available modes. The
activated mode icon and temperature set-point will be displayed on the LCD.
The thermostat will transmit the last selected operation mode command to the
control box after 2 seconds without any operation.
Operation
Depending on the system installed, there are 5 available modes ( AUTO,
COOL , HEAT , FAN and DRY ) for you to select.
See the following tables for detailed information of each mode.
NOTE : The HEAT mode is only available after the furnace is enabled.
When in OFF mode, you will be requested to set the time on the clock after the power turns on.
- Press PROGRAM button for 3 seconds to enter the clock setting mode. The time clock icon will each flash for 0.5 seconds.
- Press button to adjust the hour including AM or PM , press and hold to set the hour quickly. Press button to adjust the minute, press and hold to set the minute quickly. Press PROGRAM button to save.
Program Setting
The system allows you to set 2 time programs.
- Press PROGRAM button, the PROG 1 and clock icons will flash on the LCD.
- Press or button to change the time setting of PROG 1.
- Press MODE button to select the desired operation mode.
- Press FAN button to select the fan speed.
- Press PROGRAM button to save PROG 1 settings. The PROG 2 and clock icons will flash on the LCD.
- Repeat steps 2 to 5 to set PROG 2.
NOTE : You may press and hold the
PROGRAM button anytime for 3 seconds to cancel the program setting.
Zone Selection
- Press ZONE button on the thermostat repeatedly to select ZONE 1 , ZONE 2, ZONE 3 or ZONE 4 if they are connected and its relevant operating status will be displayed on the LCD.
- Use the control buttons to adjust the operation of the system in one particular zone.
Set the Temperature
The temperature set-point ranges from 60ºF~86ºF (16ºC~30ºC).
- Press MODE button repeatedly to toggle to your desired mode.
- Press or button to increase or decrease the temperature set-point to your comfort level.
NOTE : The temperature set-point is not available in FAN mode.
Set the Fan Speed
- Press MODE button repeatedly to toggle to your desired mode.
- Press FAN button on the thermostat to select AUTO, HIGH, MEDIUM or LOW fan speed.
NOTE : The fan speed selection is not available in DRY mode.
Mood Light
The thermostat is designed with 7 predefined colors of LED light in the air distribution box.
- Press LIGHT button on the thermostat to turn on the mood light.
- Press LIGHT button to toggle to your desired mood light.
- To turn off the mood light, press LIGHT button repeatedly until the mood light turns off.
Sleep Mode
-
Press SLEEP button on the thermostat to turn on SLEEP mode. The SLEEP icon and the current temperature set-point will be
displayed on LCD. -
After meeting desired temperature. In Cool Mode : The temperature set-point will increase 2ºF after running for 1 hour and increase 2ºF after running for 2 hours, then the fan speed will be fixed to LOW speed.
In Heat mode : The temperature set-point will decrease 2ºF after running for 1 hour and decrease 2ºF after running for 2 hours, then the fan speed will be fixed to LOW speed.
Special Features
Auto Fan
When the auto fan mode is selected, the fan speed will vary depending on the temperature difference between the temperature set-point and the room temperature.
Compressor Time Delay
A time delay of approximately three minutes occurs any time the compressor is required to begin the cooling cycle.
NOTE : The time delay occurs automatically after a mode is selected or a power event occurs to ensure pressure in the compressor is equalized appropriately, to prevent damage.
Power Interruption
In the event the power to the air conditioner or controller is interrupted, the system will restart automatically with the last status and operational parameter set-points once the power is restored.
LCD Error Code
The following error code will be displayed on the LCD when the system detects one of the following faults has occurred.
Programmable Timers
The multizone thermostat can store up two timer for each zone. The timers can be used to assign start and finish of two unique mode and fan selections. For instance, program 1 is used to set a day condition COOL mode and auto fan speed to begin at 8:00AM, program 2 is used to set an evening/night condition AUTO mode and low fan speed to begin at 7:00PM.
Wiring Diagram
Specifications
Warranty
FURRION WARRANTS FOR A PERIOD OF 1 YEAR FROM DATE OF RETAIL PURCHASE BY THE
ORIGINAL END-USE PURCHASER, THAT THIS PRODUCT, WHEN DELIVERED TO YOU IN NEW
CONDITION, IN ORIGINAL PACKAGING, FROM A FURRION AUTHORIZED RESELLER AND USED
IN NORMAL CONDITIONS, IS FREE FROM ANY DEFECTS IN MANUFACTURING, MATERIALS,
AND WORKMANSHIP. IN CASE OF SUCH DEFECT, FURRION SHALL REPLACE OR REPAIR THE
PRODUCT AT NO CHARGE TO YOU. THIS WARRANTY DOES NOT COVER: PRODUCTS WHERE THE
ORIGINAL SERIAL NUMBERS HAVE BEEN REMOVED, ALTERED OR CANNOT READILY BE
DETERMINED; DAMAGE OR LOSS CAUSED BY ACCIDENT, MISUSE, ABUSE, NEGLECT, PRODUCT
MODIFICATION, FAILURE TO FOLLOW INSTRUCTIONS IN INSTRUCTION MANUAL, COMMERCIAL
OR INDUSTRIAL USE; DAMAGE OR LOSS CAUSED TO THE DECORATIVE SURFACE OF PRODUCT;
TO ANY DATA, SOFTWARE OR INFORMATION; AND NORMAL WEAR AND TEAR. THIS WARRANTY
ONLY PROTECTS THE ORIGINAL END-USER (“YOU”) AND IS NOT TRANSFERABLE; ANY
ATTEMPT TO TRANSFER THIS WARRANTY SHALL MAKE IT IMMEDIATELY VOID. THIS
WARRANTY IS ONLY VALID IN THE COUNTRY OF PURCHASE.
THIS WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL
OTHER WARRANTIES, REMEDIES AND CONDITIONS, WHETHER ORAL OR WRITTEN, EXPRESS OR
IMPLIED. FURRION SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES,
INCLUDING, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE. IF FURRION CANNOT LAWFULLY DISCLAIM IMPLIED WARRANTIES
UNDER THIS LIMITED WARRANTY, ALL SUCH WARRANTIES, INCLUDING WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO THE
DURATION OF THIS WARRANTY.
No Furrion reseller, agent, or employee is authorized to make any modification, extension, or addition to this warranty.
FURRION IS NOT RESPONSIBLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF WARRANTY OR CONDITION, OR UNDER ANY OTHER LEGAL THEORY, INCLUDING BUT NOT LIMITED TO LOST PROFITS, DOWNTIME, GOODWILL, DAMAGE TO OR REPLACEMENT OF ANY EQUIPMENT OR PROPERTY, ANY COSTS OF RECOVERING, REPROGRAMMING, OR REPRODUCING ANY PROGRAM OR DATA STORED IN OR USED WITH FURRION PRODUCTS. FURRION’S TOTAL LIABILITY IS LIMITED TO THE REPAIR OR REPLACEMENT OF THIS PRODUCT PURSUANT TO THE TERMS OF THIS WARRANTY. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES OR EXCLUSIONS OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES OR CONDITIONS, SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY BY STATE OR (WHERE APPLICABLE IN THE COUNTRIES WHERE FURRION HAS NON-US/CANADIAN AUTHORIZED DEALERS) COUNTRY. NO ACTION OR CLAIM TO ENFORCE THIS WARRANTY SHALL BE COMMENCED AFTER THE EXPIRATION OF THE WARRANTY PERIOD.
Keep your receipt, delivery slip, or other appropriate payment record to establish the warranty period. Service under this warranty must be obtained by contacting Furrion at warranty@furrion.com
Product features or specifications as described or illustrated are subject to change without notice.
Furrion Innovation Center & Institute of Technology
● 52567 Independence Ct., Elkhart, IN 46514, USA ● Toll
free:1-888-354-5792
● Email: support@furrion.com
©2007-2018 Furrion Ltd. Furrion® and the Furrion logo are trademarks licensed
for use by
Furrion Ltd. and registered in the U.S. and other countries.
FURRION.COM
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>