hama 00176967 TH-10 Thermo/Hygrometer with Mould Alarm Instruction Manual

June 6, 2024
Hama

hama logo 1

Thermo / Hygrometer
TH-10
Operating Instructions
hama 00176967 TH-10 Thermo

Controls and Displays

1. Display
2. Temperaturetrend display (h/°C)
3. -/ON/OFF button (decrease setting value)
4. +/MAX/MIN button (increase setting value)
5. SET/MODE button (setting the alarm time)
6. Indoor temperature display
7. Humidity display
8. Symbol for mold risk (displayed when the upper limit value is exceeded)| 9. Time
10. Day of the week
11. Date
12. Symbol for mold alarm (alarm sounds when the upper limit value is exceeded)
13. Recess for wall mounting
14. Base
15. Battery compartment cover
---|---

Explanation of Warning Symbols and Notes

Warning
This symbol is used to indicate safety instructions or to draw your attention to specific hazards and risks.
Note
This symbol is used to indicate additional information or important notes.

Package contents

  • Thermometer/hygrometer with mold alarm
  • 2AAA battery
  • These operating instructions

Safety instructions

  • The product is intended for private, non-commercial use only.

  • Protect the product from dirt, moisture, and overheating, and only use it in an adry environment.

  • Do not use the product in areas where the use of electronic devices is not permitted.

  • Do not use the product in the immediate vicinity of heaters or other heat sources or in direct sunlight.

  • Do not drop the product and do not expose it to any major shocks.

  • Do not modify the product in any way. Doing so voids the warranty.

  • Keep the packaging material out of the reach of children due to the risk of suffocation.

  • Dispose of packaging material immediately according to locally applicable regulations.

  • Use the product for its intended purpose only.

  • Do not operate the product outside the power limits given in the specifications.

  • Do not open the device or continue to operate it if it becomes damaged.

  • Do not attempt to service or repair the product yourself.
    Leave any and all service work to qualified experts.

  • Keep this product, as all electrical products, out of the reach of children!

  • Use the item only in moderate climatic conditions.

Warning –Batteries

  • When inserting batteries, note the correct polarity (+and -markings) and insert the batteries accordingly.
    Failuretodosocould results in the batteries leaking or exploding.

  • Only use batteries (or rechargeable batteries) that match the specified type.

  • Before you insert the batteries, clean the battery contacts and the polar contacts.

  • Do not allow children to change batteries without supervision.

  • Do not mix old and new batteries or batteries of a different type or make.

  • Remove the batteries from products that are not being used for an extended period (unless these are being kept ready for an emergency).

  • Do not short-circuit batteries.

  • Do not charge batteries.

  • Do not throw batteries in a fire.

  • Keep batteries out of the reach of children.

  • Never open, damage, or swallow batteries or allow them to enter the environment. They can contain toxic, environmentally harmful heavy metals.

  • Immediately remove and dispose of dead batteries from the product.

  • Avoid storing, charging or using the device in extreme temperatures and extremely low atmospheric pressure (for example, at high altitudes).

Getting started

Inserting the batteries
  • Open the battery compartment (15), insert the battery/ batteries, ensuring that the batteries are inserted correctly in terms of polarity,and then close the battery compartment (15). The thermometer is now ready for use.
Replacing the batteries
  • Open the battery compartment cover (15), remove and properly dispose of the depleted batteries, and insert two new AAA batteries with the correct polarity. Then close the battery compartment cover.

Mounting

You can either stand the thermometer on an even surface using the fold-out stand (14) on the back of the device, or attach it to a wall using the opening (13) on the back of the device.

Warning

  • Before mounting, check that the wall you have chosen is suitable for the weight to be mounted Also make sure that there are no electric, water, gas or other lines running through the wall at the mounting site.
  • Do not mount the product above locations where persons might linger.

Operation

Manually setting the date/time

Time/date

  • Press and hold the button (5) for approximately 2 seconds until the year flashes.
  • Press the (4) or (3) button to select the individual values.
  • Set the following information in the order listed:
  • year, month, day, language for day of the week, display in °C or °F,12or24-hour format, time
  • Press the SET button (5) to adopt the set value displayed and go to the next item.

Note
Hold the button (4) or the button (3) to select the values faster.

Note

  • The weekday is set automatically when setting the date manually.
  • If you do not make an entry for several minutes, you automatically exit the setup mode. The settings that were made up to that point are not saved!

Note –12or24-hour format

  • In the 12-hour format, AM or PM is displayed before the time.
Maximum and minimum temperature and humidity values

• The mold alarm automatically stores the maximum and minimum indoor temperature values.
• Repeatedly press the button to switch between the current temperature, maximum temperature(MAX), and minimum temperature(MIN).

Setting the alarm time

  • Press the button (5) until the alarm sign is displayed.
  • Press and then hold the button (5) for 3seconds until the hour’s display begins to flash.
  • Press the button (4) or button (3) to select the individual values.
  • Press the button (5) to confirm the settings.
  • If you do not press the button within 30 seconds, the weather station automatically switches to normal mode.

Activating/deactivating the alarm

  • Press the button (5) to activate or deactivate the alarm.
  • The alarm time now appears on the display and flashes.
  • Press the button (4). The alarm symbol is displayed, meaning that the alarm is now activated.
  • Pressing the button (4) once more will deactivate the alarm.
  • Press any button to switch off the alarm sound.

Temperature trend display
This display shows the temperature trend over the last 12, 9, 6, 3, 0hour(s), within max. range of 20%-90%. It is only for informational purposes; you cannot make any settings on this display.
Graphic representation of humidity within the last 12 hours

Level felt (comfort index) Relative humidity
Too wet 81% to 90%
Wet  61% to 80%
Comfortable 41% to 60%
Dry 31% to 40%
Today 20% to 30%

Alarm function in the case of bacteria

Press the button (3) to activate the mold risk alarm. As soon as humidity exceeds the set value for the mold alarm, there is a risk of mold forming. If the temperatures between 25°C and 40°C and humidity is greater than 70%, the flashing symbol (8) for bacteria is shown on the display and the mold alarm (12) is triggered. Press the button (3) to deactivate the alarm. When you deactivate the mold alarm, only the flashing symbol (8) is shown on the display until the measured humidity falls back below the mold limit value entered.

Important information concerning health

Excessive indoor humidity promotes the growth of undesirable organisms. Being in a room with a mold infestation can damage people’simmune systems, lead to respiratory diseases and allergies, and is related to infections. Very dry indoor air can dry the skin, irritate the throat and paranasal sinuses, and increase the risk of infections. In an adry climate, or if heating in the home dries out the air,a humidifier can be used to increase relative humidity. Active heating and ventilation promotes a comfortable and
healthy indoor climate.

Care and Maintenance

Only clean this product with a slightly damp, lint-free cloth and do not use aggressive cleaning agents. Make sure that water does not get into the product.

Warranty Disclaimer

Hama GmbH &CoKG assumes no liability and provides no warranty for damage resulting from improper installation/ mounting, improper use of the product or failure to observe the operating instructions and/or safety notes.

**** Technical Data

Weather station

Power supply 2xAAA batteries
Temperature measuring range Indoors: 0°C–50°C
Humidity measuring range 20% -90%

Recycling Information

Note on environmental protection:
After the implementation of the European Directive 2012/19/EU and 2006/66/EU in the national legal system, the following applies: Electric and electronic devices, as well as batteries, must not be disposed of with household waste. Consumers areobliged by law to return electrical and electronic devices as well as batteries at the end of their service lives to the public collecting points set up for this purpose or point of sale. Details to this are defined by the national law of the respective country. This symbol on the product, the instruction manual, or the package indicates that a product is subject to these regulations. By recycling,  reusing the materials or other forms of utilizing old devices/Batteries, you are making an important contribution to protecting our environment.

hama logo 1Service &Support
www.hama.com
+49 9091 502-0

All listed brands are trademarks of the corresponding companies. Errors and omissions excepted, and subject to technical changes. Our general terms of delivery and payment are applied.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals