MAXAIR MAXXFAN Deluxe Instruction Manual

June 6, 2024
MAXAIR

MAXXFAN Deluxe

MAXXFAN® INSTALLATION INSTRUCTIONS, INFORMATION AND OPERATING GUIDE
FOR ALL MAXXFAN® Deluxe MODELS
5100K, 5101K, 5301K, 6200K, 6201K, 6401K, 7000K, 7001K, 7500K, 7501K, 8000K, 8001K, 8500K, 8501K, 8700K, 8751K, 8900K, 8951K
READ AND SAVE THESE INSTRUCTIONS
NOTE: Refer to supplied Operating Instructions regarding the model you have purchased. The MAXXFAN installs into a standard RV roof opening of 14″ x 14″. To determine if your roof opening is correctly sized, simply remove the interior ceiling garnish trim ring of your existing roof vent and measure the ceiling opening or verify the opening is large enough by sliding the MAXXFAN interior garnish trim ring into the opening. Due to the EXHAUST / INTAKE LOUVERS that face the rear of the vehicle, the MAXXFAN requires a roof area clear of obstructions such as air conditioners, storage boxes, etc. for at least 8″ to the rear of the existing standard roof vent flange outer rear edge. The MAXXFAN is designed for a minimum roof thickness of 1 1/8″ to a maximum of 6 1/2″. If your roof thickness is less than 1 1/8″, build additional thickness at the ceiling opening using wood or other suitable material. The MAXXFAN requires a minimum 12 Volt DC, 5 amp service. Confirm that the circuit you intend to use will accommodate the additional load. Use the proper gauge stranded wire for electrical connections.
WARNING! To reduce risk of fire, injury to persons or damage to property, use only in the manner intended by AIRXCEL, INC. Should you have questions, please contact AIRXCEL/MAXXAIR VENTILATION SOLUTIONS Customer Service at 316.832.4357.
P/N: 11D90001K 08-2017

INSTALLATION INSTRUCTIONS – ALL MODELS

STEP 1 MAXXFAN requires a roof opening of 14″ x 14″. If you are replacing another type already installed, remove the old existing roof vent. Remove all old roof sealant for a minimum of 2″ entirely around the roof opening.
Place the MAXXFAN Roof Receiving Flange (reference photo #2 below) into the roof opening and trace a pencil line around it to verify the clean seal area that will be required. Note that the Roof Receiving Flange must be centered in the roof opening with the metal clips facing the sides of the vehicle (not facing the front or rear of the vehicle).

showing (+) must be connected to the vehicle 12 volt (+) positive supply.
STEP 4 Confirm the 4 metal mounting clips are firmly in place on the Roof Receiving Flange. With the MAXXFAN open and the exhaust/intake louvers facing the rear of the vehicle, lower the MAXXFAN onto the Roof Receiving Flange. Make sure the power wires slide to the vehicle interior and do not become entangled on the Roof Receiving Flange’s upward edge.

CAUTION: When installing your Roof Flange, only use a caulking/sealant compatible with the flange (plastic product) and the roof surface. DO NOT use materials containing solvents such as or similar to Xylene, Toluene, Methyl Ethyl Ketone, Acetate or Acetone as they can damage the flange. Also, Polysulfide (Thiokol) type sealants must be avoided. Silicone Sealants such as G.E. Silicone II (nonpaintable) used for outdoor applications have proven to be suitable for this installation.

METAL MOUNTING CLIPS

If in doubt, please contact the manufacturer of your RV for further information.

4

RECEIVING FLANGE UPPER EDGE

STEP 2 Apply Sealant or Caulking within the area you have traced on the roof with a pencil. Apply it carefully to avoid gaps that may allow water to enter. Fasten the Roof Receiving Flange to the roof with screws provided. Apply additional roof sealant over the screw heads and around the edge of the roof flange.
CAUTION: Disconnect main vehicle power before connecting 12 volt DC power to the MAXXFAN!
NOTE: The MAXXFAN must be fully opened prior to proceeding to STEP 3. Turn knob to fully raise the vent lid. NOTE: On the NON-REMOTE controlled models, the knob must be pulled out to unlock before turning.

STEP 5 Verify the MAXXFAN is fully seated down on the Roof Receiving Flange and fasten the MAXXFAN to the Roof Receiving Flange using the four 3/4″ #10 stainless steel screws provided.
CAUTION: Only use the screws provided/specified for this installation or internal damage and/or insecure mounting may result.

OPEN / CLOSE KNOB

5

ROOF FLANGE
2
STEP 3 Using the insulated electrical connectors provided, connect the vehicle’s 12 volt power to the two MAXXFAN power wires located on the driver side of the MAXXFAN. NOTE: The MAXXFAN black wire identified with a tag
2

THIS COMPLETES THE ROOF TOP PORTION OF THE INSTALLATION
NOTE: Re-apply 12 volt vehicle power. The MAXXFAN, excluding the 5301K and 6401K, will emit a beeping sound to indicate power is properly connected. In addition, the Remote Control model will automatically close the vent cover. If the MAXXFAN does not beep when power is connected, go back to step #3. Confirm that proper connections were made and 12 volt power is on and available. This MAXXFAN incorporates a self-resetting fuse on the circuit board located in the ceiling assembly. It can be reset by removing and reapplying power. If your fan fails to operate or needs reset, contact Customer Service at 316.832.4357 for assistance or solicit the aid of an electrical technician.

STEP 6 The interior Garnish Trim Ring must be trimmed to fit your particular RV roof thickness. To accomplish this, measure the distance from the vehicle ceiling surface to each corner of the MAXXFAN Control Plate.
Most RV roofs have some slope, so measuring each corner is necessary. The Garnish ring should be cut 1/4″ to 1/2″ longer than the dimensions measured at each corner.
In Picture #6 below, the installation measures 3 1/2″ from the ceiling (this is an example only) to the Control Plate. After adding 1/2″ as in this example, using a ruler, place a mark at 4″ on each corner of each side of the Garnish Ring (refer to 6A, right). Once marked, draw a line connecting all 4″ marks on the outside of the Garnish ring and trim accordingly (refer to 6B, right).

6A

THERMOSTAT SENSOR

GARNISH RING

3 1/2″
6 CEILING
NOTE: DO NOT probe or tamper with the thermostat sensor or IR sensor shown in illustration #6 above.

6B

GARNISH RING

MEASUREMENTS STATED IN STEP 6 ARE USED AS AN EXAMPLE FOR ILLUSTRATION PURPOSES ONLY

7
STEP 7 Complete the installation by placing any excess wiring to the inside of the roof opening and sliding the Garnish Ring into position. Fasten in place by using the four painted flat head screws provided.

CONGRATULATIONS!!!

You have successfully completed the

installation of your new

MAXXFAN Deluxe.

If you have questions, please visit

AIRXCEL.com or contact

Customer Service at 316.832.4357.

3

FOR REMOTE CONTROL MODELS: Refer to the Operating Instructions for use and testing of your remote control. Install two AAA batteries, follow instructions, aim remote at the ceiling unit and test your fan. The Remote Control comes with a cradle for wall mount storage of the Handheld Remote Control. Mount the cradle to your wall using the (2) #6 screws provided. Remote may be placed into the wall cradle for storage.

MAXXFAN® 2 YEAR LIMITED WARRANTY
AIRXCEL, INC. – RV PRODUCTS DIVISION / MAXXAIR RETAINING KNOB SERIAL NUMBER Ventilation Solutions warrants to be free of manufacturing defects, regardless of ownership for a period of two (2) years from the original date of purchase. If the product is installed as original equipment on a vehicle, the warranty period shall begin on the date of the original purchase of the vehicle. In all other instances, the warranty shall begin on the date the product was purchased. You must keep your original sales receipt. This Limited Warranty does not include “Acts of God,” failure due to misuse, improper installation or accidental / incidental damages. Please call AIRXCEL, INC. at 1-316-832-4357 if you have any questions or need assistance.
Please have your original sales receipt and MAXXFAN Serial Number readily available. AIRXCEL will correct the confirmed defect within 45 days by repair or replacement without charge for materials and labor. This limited warranty does not cover any freight costs for the return of the product to or from AIRXCEL, INC. or costs associated with installation, removal or reinstallation of the product.
We invite your comments and suggestions regarding our products. Any information you supply is for AIRXCEL / MAXXAIR’s internal use and will not be shared or sold to others.
The Serial Number for your MAXXFAN is located on the back page of this booklet and on the fan control plate under the round insect screen frame. (Your serial number may or may not be located in the same position as referenced in the above image). Reference your operating guide. Rotate the four retaining knobs 180° and remove the screen to view. DO NOT OPERATE the MAXXFAN with the screen removed.
CAUTIONS AND CARE OF YOUR MAXXFAN® This product has been manufactured using prime UV stabilized Polymers for maximum toughness and durability. However, the use of caustic or solvent based chemicals can cause cracking and product failure.
PLEASE CLEAN ALL PARTS WITH MILD SOAP AND WATER ONLY. Do not use Petroleum Containing Additives or Solvent Based Products on any of the MAXXFAN’s components or its corrosion resistant hardware.
LISTED BELOW ARE SOME KNOWN CHEMICAL PRODUCTS TO BE AWARE OF: NON COMPATIBLE CHEMICALS – DO NOT USE THESE: Ketones, Esters, Acetone or other like solvents, Halogenated Hydrocarbons, Amines, Aromatic Hydrocarbons, (Loctite Formulas), or any products containing references to: chemicals that are not to be used on plastics.
GENERALLY COMPATIBLE (But should be used in low concentration where possible) Acids, Alcohol, Alkalis, Aliphatic Hydrocarbons, Mild Soap Solution (avoid strong Alkaline Material), Silicone Oil or Greases (avoid those containing Aromatic Hydrocarbons or other additives). Review the contents of your cleaning materials carefully.
For additional information regarding your NEW MAXXFAN® Deluxe, please refer to the INFORMATION AND OPERATION GUIDES
FOR YOUR PARTICULAR MODEL ON THE FOLLOWING PAGES.
4

INFORMATION AND OPERATING GUIDE
KEYPAD FOR MAXXFAN® Deluxe MODELS 5301K · 6401K

KNOB, VENT LID OPEN/CLOSE Manual Opening Pull to unlock prior to turning. Rotate Knob clockwise to Close Vent Lid; Rotate Knob counter-clockwise to Open Vent Lid. Push “IN” to lock when Vent Lid is open or closed. It may be necessary to slightly rotate the knob to properly align it while pushing it up to lock.
Do not use excessive force when operating Knob.
KEYPAD CONTROLS Use Keys on Keypad to control MAXXFAN functions (see descriptions below).
INSECT SCREEN RETAINER KNOB Rotate all 4 knobs 1/2 turn to remove screen. Caution: Never operate fan with screen removed.
CEILING FAN MODE With the fan motor running, close the Vent Lid to enter Ceiling Fan Mode. The fan motor will continue to run and circulate air within the RV cabin.
SERIAL NUMBER LABEL The serial number label is located underneath the round insect screen.
NOTE: The MAXXFAN is designed to be fully opened or fully closed when the vehicle is moving.

KEYPAD CONTROLS
KEYPAD FOR MAXXFAN® Deluxe MODELS
5301K · 6401K
CAUTION: When removing insect screen for cleaning, turn the MAXXFAN OFF and remove the vehicle 12 volt power to the MAXXFAN. When cleaning your MAXXFAN, use only a mild detergent solution.

FAN ON 1-2-3-4

Turns the Fan Motor ON to the last

selected speed

When the fan is running, cycles

through four (4) speeds, once HIGH

FAN

FAN ON SPEED is reached, fan motor cycles

OFF

1-2-3-4 back to LOW SPEED

Turns the Fan Motor OFF at any selected speed
FAN 5 OFF

INFORMATION AND OPERATING GUIDE
KEYPAD FOR MAXXFAN® Deluxe MODELS
5100K, 5101K, 6200K, 6201K, 7000K, 7001K, 7500K, 7501K, 8000K, 8001K, 8500K, 8501K
KNOB, VENT LID OPEN/CLOSE Manual Opening Models Pull to unlock prior to turning. Rotate Knob clockwise to Close Vent Lid; Rotate Knob counter- clockwise to Open Vent Lid. Push “IN” to lock when Vent Lid is open or closed.
Automatic Opening Models Allows closing of the vent lid in the event of RV power loss. This knob does not lock. Do not push in or pull out. Rotate knob clockwise to close vent lid; rotate knob counter-clockwise to open vent lid.
Do not use excessive force when operating Knob.
KEYPAD CONTROLS Use Keys on Keypad to control MAXXFAN functions (see descriptions on next page). NOTE: IR Sensor not on all models
INSECT SCREEN RETAINER KNOB Rotate all 4 knobs 1/2 turn to remove screen. Caution: Never operate fan with screen removed
THERMOSTAT TEMPERATURE SENSOR
CEILING FAN MODE With the fan motor running, close the Vent Lid to enter Ceiling Fan Mode. The fan motor will continue to run and circulate air within the RV cabin.
SERIAL NUMBER LABEL The serial number label is located underneath the round insect screen.
NOTE: The MAXXFAN is designed to be fully opened or fully closed when the vehicle is moving.
CAUTION: When removing screen for cleaning, turn the MAXXFAN OFF and remove the vehicle 12 volt power to the MAXXFAN. When cleaning your MAXXFAN, use only a mild detergent solution.
6

KEYPAD CONTROLS
KEYPAD FOR MAXXFAN® Deluxe INTAKE/EXHAUST MODELS 5100K, 6200K, 7000K, 7500K,
8000K, 8500K

KEYPAD CONTROLS
KEYPAD FOR MAXXFAN® Deluxe EXHAUST ONLY MODELS 5101K, 6201K, 7001K, 7501K
8001K, 8501K

NOTE: A beeping sound will confirm each key press
ON/OFF: Use this key to start the fan or to turn off the fan. On Automatic Opening Models the lid will also open or close when the fan is turned on or off. On Manual Opening Models pushing this key while in Auto Mode will exit Auto Mode, turn off the fan and the lid will stay in the position you selected. On Automatic Opening Models this button will exit Auto mode, turn the fan off, and close the lid.
IN/OUT: Use this key to reverse the direction of the fan, the fan will slow down and pause for two (2) seconds before resuming operation in the opposite direction. Note: In Auto Mode the fan direction is automatically positioned to Exhaust, but may be overridden and changed to Intake by depressing this key. PLEASE NOTE: THIS KEY HAS BEEN REMOVED ON EXHAUST ONLY MODELS
AUTO: Auto Mode allows the thermostat to turn the fan ON and OFF depending on the thermostat setting. Press this key once for less than three (3) seconds to enter Auto Mode, three (3) quick beeps will confirm the MAXXFAN has entered Auto Mode. To EXIT Auto Mode, press the ON/OFF key. Initial factory set point for the thermostat is 78°F/25°C. The green LED will light to indicate the MAXXFAN is in Auto Mode. To adjust, follow instructions below: If no previous thermostat temperature was entered, or you wish to change a previous set temperature, press the HOLD TO SET key for more than 3 seconds and you will hear one long beep and the thermostat will be reset to 78°F. To further adjust the set temperature, if desired, use the (+) or (-) Arrow keys to adjust at 1° increments per press. The fan will emit a beeping sound to confirm this setting. If a previous thermostat temperature was entered, the fan will remember this temperature setting and the next time you enter Auto Mode, the fan will start ventilating automatically as directed by the thermostat. The fan speed will automatically adjust based on the cabin temperature. As cabin temperature rises, the fan increases in speed. Note: If 12 volt RV power is removed from the MAXXFAN, the thermostat will be reset to 78°F/25°C.
ARROW – When in Auto Mode: Use the (+) & (-) Arrow keys to adjust the thermostat set temperature up or down in 1° increments per press. When in Manual Mode: Use the (+) & (-) Arrow keys to adjust the fan speed up or down. When the fan speed reaches either the maximum or minimum speed, the fan will respond with 2 quick beeps to indicate this.
ARROW KEYS PRESSED TOGETHER: Automatic Lift Models Only Press the (+) & (-) Arrow keys at the same time to Open or Close the lid. The fan motor will remain in its current state.
7

REMOTE CONTROL OPERATING GUIDE
WIRELESS REMOTE CONTROL FOR MAXXFAN® Deluxe MODELS 7000K · 7500K
Optional for 8000K, 8500K, 8700K, 8900K Models

FAN ON & POWER OFF – Press this button: · To start the fan · To turn the fan off · To exit Auto Mode

Remove protective film from Display Screen

VENT LID POSITION – Press this button to open or close the vent lid · While the fan is running in Manual Mode press once to close the vent lid and enter “Ceiling Fan” Mode. NOTE: This button is not active in Auto Mode. If the fan loses 12volt RV power or power is removed from the fan, use the knob located at the ceiling to manually open or close the vent lid if desired.

AIR EXHAUST / INTAKE – Press this button to reverse the fan from intake or exhaust NOTE: In Auto Mode, the fan direction is automatically positioned to Exhaust, but may be overridden and changed to Intake by depressing this key.

FAN AUTO MODE – Press this button to enter Auto Mode · Auto Mode allows the fan lid to automatically open and the fan motor to operate as dictated by the thermostat set point temperature. Once the cabin temperature cools and reaches the set point temperature, the fan lid will close and the fan motor will shut off. · Pressing this button while in Auto Mode will shut off Auto Mode, close the vent lid and shut off the fan motor.

THERMOSTAT SET TEMPERATURE TEMP + ~ Press this button to increase the Set Temperature for Auto Mode. TEMP – ~ Press this button to decrease the Set Temperature for Auto Mode. NOTE: The thermostat temperature range is from 29°F to 99°F or -2°C to 37°C. To change from Fahrenheit to Celsius on the temperature display, press and hold both set temperature keys simultaneously.

FAN SPEED Fan Speed + ~ Press

SET TEMPERATURE

TRANSMIT

LOW BATTERY INDICATOR

this button to increase

the fan speed. The fan has ten speeds. Fan Speed – ~ Press this

AUTO MODE INDICATOR

ROOM TEMPERATURE

button to decrease the

fan speed. The fan has ten speeds. NOTE: When the fan

FAN ON INDICATOR

VENT LID IN AUTO MODE

speed reaches either the maximum or minimum

CEILING FAN

speed, the fan will respond with 2 quick

FAN OFF INDICATOR

VENT LID POSITION

beep sounds to indicate

this.

LOW BATTERY

FAN SPEED

CEILING FAN MODE

AIR DIRECTION INDICATOR

INDICATOR

· When the battery is at full charge, three black power bars are displayed.

· One or zero power bars displayed indicates the batteries need replacement.

TRANSMISSION SIGNAL · This symbol is displayed on the screen when any button is pressed to indicate the signal was transmitted to the fan. · A beep sound from the ceiling unit indicates the signal from the remote control was received by the fan.

8

REMOTE CONTROL OPERATING GUIDE
WIRELESS REMOTE CONTROL FOR MAXXFAN® Deluxe MODELS 7001K · 7501K
Optional for 8001K, 8501K Models

FAN ON & POWER OFF – Press this button: · To start the fan · To turn the fan off · To exit Auto Mode

Remove protective film from Display Screen

VENT LID POSITION – Press this button to open or close the vent lid · While the fan is running in Manual Mode press once to close the vent lid and enter “Ceiling Fan” Mode. NOTE: This button is not active in Auto Mode. If the fan loses 12volt RV power or power is removed from the fan, use the knob located at the ceiling to manually open or close the vent lid if desired.

AIR OUT

FAN AUTO MODE – Press this button to enter Auto Mode · Auto Mode allows the fan lid to automatically open and the fan motor to operate as dictated by the thermostat set point temperature. Once the cabin temperature cools and reaches the set point temperature, the fan lid will close and the fan motor will shut off. · Pressing this button while in Auto Mode will shut off Auto Mode, close the vent lid and shut off the fan motor.

THERMOSTAT SET TEMPERATURE TEMP + ~ Press this button to increase the Set Temperature for Auto Mode. TEMP – ~ Press this button to decrease the Set Temperature for Auto Mode. NOTE: The thermostat temperature range is from 29°F to 99°F or -2°C to 37°C. To change from Fahrenheit to Celsius on the temperature display, press and hold both set temperature keys simultaneously.

FAN SPEED Fan Speed + ~ Press

SET TEMPERATURE

TRANSMIT

LOW BATTERY INDICATOR

this button to increase

the fan speed. The fan has ten speeds. Fan Speed – ~ Press this

AUTO MODE INDICATOR

ROOM TEMPERATURE

button to decrease the

fan speed. The fan has ten speeds. NOTE: When the fan

FAN ON INDICATOR

VENT LID IN AUTO MODE

speed reaches either the maximum or minimum

CEILING FAN

speed, the fan will respond with 2 quick

FAN OFF INDICATOR

VENT LID POSITION

beep sounds to indicate

this.

LOW BATTERY

FAN SPEED

CEILING FAN MODE

AIR DIRECTION INDICATOR

INDICATOR

· When the battery is at full charge, three black power bars are displayed.

· One or zero power bars displayed indicates the batteries need replacement.

TRANSMISSION SIGNAL · This symbol is displayed on the screen when any button is pressed to indicate the signal was transmitted to the fan. · A beep sound from the ceiling unit indicates the signal from the remote control was received by the fan.

9

OPERATION GUIDE – 1-SWITCH WALL CONTROL
FOR USE WITH MAXXFAN® Deluxe MANUAL OPENING Models
5100K, 5101K, 6200K, 6201K

OPERATION OF 1-SWITCH WALL CONTROL

FAN 1-2-3

When Fan is running, select LOW,

Turns the fan motor ON at the last MEDIUM or HIGH Speed. Once

selected speed

HIGH Speed is reached, the fan

motor cycles back to LOW Speed.

FAN OFF Turns the Fan Motor OFF

OPERATION GUIDE – 2-SWITCH WALL CONTROL
FOR USE WITH MAXXFAN® Deluxe ELECTRIC OPENING Models
7000K, 7001K, 7500K, 7501K, 8000K, 8001K, 8500K, 8501K, 8700K, 8751K, 8900K, 8951K

CONTROL FAN 1-2-3

DESCRIPTION

When Fan is running, select

Turns the fan motor ON at LOW, MEDIUM or HIGH

the last selected speed and Speed. Once HIGH Speed is

OPENS the Vent Lid.

reached, the fan motor cycles

back to LOW Speed.

FAN OFF Turns the Fan Motor OFF and CLOSES the Vent Lid

VENT OPEN

OPENS the Vent Lid

VENT CLOSED

CLOSES the Vent Lid

Fan motor remains in previous state
Fan motor remains in previous state. If fan motor is ON, the MAXXFAN enters Ceiling Fan Mode

OPERATION GUIDE – 4 KEY WALL CONTROL
FOR MAXXFAN® Deluxe Models 8751K · 8951K

FAN ON 1-2-3-4

VENT OPEN

OPERATION OF 4 KEY WALL CONTROL

FAN ON 1-2-3-4

Turns the fan motor ON at the last selected speed and OPENS the Vent Lid.

When Fan is running, cycles through four (4) fan Speeds. Once HIGH Speed is reached, the fan motor cycles back to LOW Speed.

FAN OFF

Turns the Fan Motor OFF and CLOSES the Vent Lid

FAN OFF

VENT CLOSE

VENT OPEN

OPENS the Vent Lid

VENT CLOSE

CLOSES the Vent Lid

10

Fan motor remains in previous state
Fan motor remains in previous state. If fan motor is ON, the MAXXFAN enters Ceiling Fan Mode

OPERATION GUIDE – 5 KEY WALL CONTROL
OPTIONAL FOR MAXXFAN® Deluxe Models 7001K · 7501K · 8001K · 8501K

FAN ON/OFF
OPEN/ CLOSE
HOLD TO SET 78°F
AUTO

FAN ON/OFF
AUTO
OPEN/ CLOSE

OPERATION OF 5 KEY WALL CONTROL
Turns the fan motor ON at the last selected speed and OPENS the Vent Lid. Turns the fan motor OFF and CLOSES Vent Lid. Pressing this key when in AUTO mode will cause the fan to exit AUTO mode.
Puts the fan in AUTOMATIC thermostat mode. Vent lid will automatically open and fan will turn on to cool RV when set temperature is reached. Once RV is cooled down, fan will turn off and vent lid will close. Thermostat is set to last selected temperature (memory function). Green LED will light to indicate MAXXFAN is in AUTO mode. Hold key for three (3) seconds to reset thermostat temperature to 78°F, use (+) & (-) keys to adjust set temperature up or down. Press ON/OFF key to exit AUTO mode.
Adjusts the fan speed or thermostat set temperature. When fan is on in MANUAL mode: adjusts fan speed up or down from 10% to 100% (10 speeds). When fan is in AUTO mode: adjusts thermostat set temperature up or down by 1°F per key press.
OPENS and CLOSES the motorized Vent Lid. Allows the vent lid to be open or closed with the fan motor on or off. Close vent lid with fan motor running in Manual mode to enter Ceiling Fan Mode.

OPERATION GUIDE 6 KEY WALL CONTROL
FOR MAXXFAN® Deluxe Models 8700K · 8900K OPTIONAL FOR MAXXFAN® Deluxe Models 7000K, 7500K, 8000K, 8500K

FAN ON/OFF

OPEN/ CLOSE
HOLD TO SET 78°F
AUTO

IN / OUT

FAN ON/OFF
AUTO
OPEN/ CLOSE IN/OUT

OPERATION OF 6 KEY WALL CONTROL
Turns the fan motor ON at the last selected speed and OPENS the Vent Lid. Turns the fan motor OFF and CLOSES Vent Lid. Pressing this key when in AUTO mode will cause the fan to exit AUTO mode.
Puts the fan in AUTOMATIC thermostat mode. Vent lid will automatically open and fan will turn on to cool RV when set temperature is reached. Once RV is cooled down, fan will turn off and vent lid will close. Thermostat is set to last selected temperature (memory function). Green LED will light to indicate MAXXFAN is in AUTO mode. Hold key for three (3) seconds to reset thermostat temperature to 78°F, use (+) & (-) keys to adjust set temperature up or down. Press ON/OFF key to exit AUTO mode.
Adjusts the fan speed or thermostat set temperature. When fan is on in MANUAL mode: adjusts fan speed up or down from 10% to 100% (10 speeds). When fan is in AUTO mode: adjusts thermostat set temperature up or down by 1°F per key press.
OPENS and CLOSES the motorized Vent Lid. Allows the vent lid to be open or closed with the fan motor on or off. Close vent lid with fan motor running in Manual mode to enter Ceiling Fan Mode.
Reverses fan motor for either INTAKE or EXHAUST air direction.

11

. . . reinventing comfort!
PLACE CONSUMER LABEL HERE
For additional product information please visit www.AIRXCEL.com AIRXCEL, INC. – RV Products Division / MAXXAIR
3050 N. St. Francis St. · Wichita, KS 67219 · 316.832.3400

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals