MAXAIR MAXXFAN Deluxe Instruction Manual
- June 6, 2024
- MAXAIR
Table of Contents
MAXXFAN Deluxe
MAXXFAN® INSTALLATION INSTRUCTIONS, INFORMATION AND OPERATING GUIDE
FOR ALL MAXXFAN® Deluxe MODELS
5100K, 5101K, 5301K, 6200K, 6201K, 6401K, 7000K, 7001K, 7500K, 7501K, 8000K,
8001K, 8500K, 8501K, 8700K, 8751K, 8900K, 8951K
READ AND SAVE THESE INSTRUCTIONS
NOTE: Refer to supplied Operating Instructions regarding the model you have
purchased. The MAXXFAN installs into a standard RV roof opening of 14″ x 14″.
To determine if your roof opening is correctly sized, simply remove the
interior ceiling garnish trim ring of your existing roof vent and measure the
ceiling opening or verify the opening is large enough by sliding the MAXXFAN
interior garnish trim ring into the opening. Due to the EXHAUST / INTAKE
LOUVERS that face the rear of the vehicle, the MAXXFAN requires a roof area
clear of obstructions such as air conditioners, storage boxes, etc. for at
least 8″ to the rear of the existing standard roof vent flange outer rear
edge. The MAXXFAN is designed for a minimum roof thickness of 1 1/8″ to a
maximum of 6 1/2″. If your roof thickness is less than 1 1/8″, build
additional thickness at the ceiling opening using wood or other suitable
material. The MAXXFAN requires a minimum 12 Volt DC, 5 amp service. Confirm
that the circuit you intend to use will accommodate the additional load. Use
the proper gauge stranded wire for electrical connections.
WARNING! To reduce risk of fire, injury to persons or damage to property, use
only in the manner intended by AIRXCEL, INC. Should you have questions, please
contact AIRXCEL/MAXXAIR VENTILATION SOLUTIONS Customer Service at
316.832.4357.
P/N: 11D90001K 08-2017
INSTALLATION INSTRUCTIONS – ALL MODELS
STEP 1 MAXXFAN requires a roof opening of 14″ x 14″. If you are replacing
another type already installed, remove the old existing roof vent. Remove all
old roof sealant for a minimum of 2″ entirely around the roof opening.
Place the MAXXFAN Roof Receiving Flange (reference photo #2 below) into the
roof opening and trace a pencil line around it to verify the clean seal area
that will be required. Note that the Roof Receiving Flange must be centered in
the roof opening with the metal clips facing the sides of the vehicle (not
facing the front or rear of the vehicle).
showing (+) must be connected to the vehicle 12 volt (+) positive supply.
STEP 4 Confirm the 4 metal mounting clips are firmly in place on the Roof
Receiving Flange. With the MAXXFAN open and the exhaust/intake louvers facing
the rear of the vehicle, lower the MAXXFAN onto the Roof Receiving Flange.
Make sure the power wires slide to the vehicle interior and do not become
entangled on the Roof Receiving Flange’s upward edge.
CAUTION: When installing your Roof Flange, only use a caulking/sealant compatible with the flange (plastic product) and the roof surface. DO NOT use materials containing solvents such as or similar to Xylene, Toluene, Methyl Ethyl Ketone, Acetate or Acetone as they can damage the flange. Also, Polysulfide (Thiokol) type sealants must be avoided. Silicone Sealants such as G.E. Silicone II (nonpaintable) used for outdoor applications have proven to be suitable for this installation.
METAL MOUNTING CLIPS
If in doubt, please contact the manufacturer of your RV for further information.
4
RECEIVING FLANGE UPPER EDGE
STEP 2 Apply Sealant or Caulking within the area you have traced on the roof
with a pencil. Apply it carefully to avoid gaps that may allow water to enter.
Fasten the Roof Receiving Flange to the roof with screws provided. Apply
additional roof sealant over the screw heads and around the edge of the roof
flange.
CAUTION: Disconnect main vehicle power before connecting 12 volt DC power to
the MAXXFAN!
NOTE: The MAXXFAN must be fully opened prior to proceeding to STEP 3. Turn
knob to fully raise the vent lid. NOTE: On the NON-REMOTE controlled models,
the knob must be pulled out to unlock before turning.
STEP 5 Verify the MAXXFAN is fully seated down on the Roof Receiving Flange
and fasten the MAXXFAN to the Roof Receiving Flange using the four 3/4″ #10
stainless steel screws provided.
CAUTION: Only use the screws provided/specified for this installation or
internal damage and/or insecure mounting may result.
OPEN / CLOSE KNOB
5
ROOF FLANGE
2
STEP 3 Using the insulated electrical connectors provided, connect the
vehicle’s 12 volt power to the two MAXXFAN power wires located on the driver
side of the MAXXFAN. NOTE: The MAXXFAN black wire identified with a tag
2
THIS COMPLETES THE ROOF TOP PORTION OF THE INSTALLATION
NOTE: Re-apply 12 volt vehicle power. The MAXXFAN, excluding the 5301K and
6401K, will emit a beeping sound to indicate power is properly connected. In
addition, the Remote Control model will automatically close the vent cover. If
the MAXXFAN does not beep when power is connected, go back to step #3. Confirm
that proper connections were made and 12 volt power is on and available. This
MAXXFAN incorporates a self-resetting fuse on the circuit board located in the
ceiling assembly. It can be reset by removing and reapplying power. If your
fan fails to operate or needs reset, contact Customer Service at 316.832.4357
for assistance or solicit the aid of an electrical technician.
STEP 6 The interior Garnish Trim Ring must be trimmed to fit your particular
RV roof thickness. To accomplish this, measure the distance from the vehicle
ceiling surface to each corner of the MAXXFAN Control Plate.
Most RV roofs have some slope, so measuring each corner is necessary. The
Garnish ring should be cut 1/4″ to 1/2″ longer than the dimensions measured at
each corner.
In Picture #6 below, the installation measures 3 1/2″ from the ceiling (this
is an example only) to the Control Plate. After adding 1/2″ as in this
example, using a ruler, place a mark at 4″ on each corner of each side of the
Garnish Ring (refer to 6A, right). Once marked, draw a line connecting all 4″
marks on the outside of the Garnish ring and trim accordingly (refer to 6B,
right).
6A
THERMOSTAT SENSOR
GARNISH RING
3 1/2″
6 CEILING
NOTE: DO NOT probe or tamper with the thermostat sensor or IR sensor shown in
illustration #6 above.
6B
GARNISH RING
MEASUREMENTS STATED IN STEP 6 ARE USED AS AN EXAMPLE FOR ILLUSTRATION PURPOSES ONLY
7
STEP 7 Complete the installation by placing any excess wiring to the inside of
the roof opening and sliding the Garnish Ring into position. Fasten in place
by using the four painted flat head screws provided.
CONGRATULATIONS!!!
You have successfully completed the
installation of your new
MAXXFAN Deluxe.
If you have questions, please visit
AIRXCEL.com or contact
Customer Service at 316.832.4357.
3
FOR REMOTE CONTROL MODELS: Refer to the Operating Instructions for use and testing of your remote control. Install two AAA batteries, follow instructions, aim remote at the ceiling unit and test your fan. The Remote Control comes with a cradle for wall mount storage of the Handheld Remote Control. Mount the cradle to your wall using the (2) #6 screws provided. Remote may be placed into the wall cradle for storage.
MAXXFAN® 2 YEAR LIMITED WARRANTY
AIRXCEL, INC. – RV PRODUCTS DIVISION / MAXXAIR RETAINING KNOB SERIAL NUMBER
Ventilation Solutions warrants to be free of manufacturing defects, regardless
of ownership for a period of two (2) years from the original date of purchase.
If the product is installed as original equipment on a vehicle, the warranty
period shall begin on the date of the original purchase of the vehicle. In all
other instances, the warranty shall begin on the date the product was
purchased. You must keep your original sales receipt. This Limited Warranty
does not include “Acts of God,” failure due to misuse, improper installation
or accidental / incidental damages. Please call AIRXCEL, INC. at
1-316-832-4357 if you have any
questions or need assistance.
Please have your original sales receipt and MAXXFAN Serial Number readily
available. AIRXCEL will correct the confirmed defect within 45 days by repair
or replacement without charge for materials and labor. This limited warranty
does not cover any freight costs for the return of the product to or from
AIRXCEL, INC. or costs associated with installation, removal or reinstallation
of the product.
We invite your comments and suggestions regarding our products. Any
information you supply is for AIRXCEL / MAXXAIR’s internal use and will not be
shared or sold to others.
The Serial Number for your MAXXFAN is located on the back page of this booklet
and on the fan control plate under the round insect screen frame. (Your serial
number may or may not be located in the same position as referenced in the
above image). Reference your operating guide. Rotate the four retaining knobs
180° and remove the screen to view. DO NOT OPERATE the MAXXFAN with the screen
removed.
CAUTIONS AND CARE OF YOUR MAXXFAN® This product has been manufactured using
prime UV stabilized Polymers for maximum toughness and durability. However,
the use of caustic or solvent based chemicals can cause cracking and product
failure.
PLEASE CLEAN ALL PARTS WITH MILD SOAP AND WATER ONLY. Do not use Petroleum
Containing Additives or Solvent Based Products on any of the MAXXFAN’s
components or its corrosion resistant hardware.
LISTED BELOW ARE SOME KNOWN CHEMICAL PRODUCTS TO BE AWARE OF: NON COMPATIBLE
CHEMICALS – DO NOT USE THESE: Ketones, Esters, Acetone or other like solvents,
Halogenated Hydrocarbons, Amines, Aromatic Hydrocarbons, (Loctite Formulas),
or any products containing references to: chemicals that are not to be used on
plastics.
GENERALLY COMPATIBLE (But should be used in low concentration where possible)
Acids, Alcohol, Alkalis, Aliphatic Hydrocarbons, Mild Soap Solution (avoid
strong Alkaline Material), Silicone Oil or Greases (avoid those containing
Aromatic Hydrocarbons or other additives). Review the contents of your
cleaning materials carefully.
For additional information regarding your NEW MAXXFAN® Deluxe, please refer to
the INFORMATION AND OPERATION GUIDES
FOR YOUR PARTICULAR MODEL ON THE FOLLOWING PAGES.
4
INFORMATION AND OPERATING GUIDE
KEYPAD FOR MAXXFAN® Deluxe MODELS 5301K · 6401K
KNOB, VENT LID OPEN/CLOSE Manual Opening Pull to unlock prior to turning.
Rotate Knob clockwise to Close Vent Lid; Rotate Knob counter-clockwise to Open
Vent Lid. Push “IN” to lock when Vent Lid is open or closed. It may be
necessary to slightly rotate the knob to properly align it while pushing it up
to lock.
Do not use excessive force when operating Knob.
KEYPAD CONTROLS Use Keys on Keypad to control MAXXFAN functions (see
descriptions below).
INSECT SCREEN RETAINER KNOB Rotate all 4 knobs 1/2 turn to remove screen.
Caution: Never operate fan with screen removed.
CEILING FAN MODE With the fan motor running, close the Vent Lid to enter
Ceiling Fan Mode. The fan motor will continue to run and circulate air within
the RV cabin.
SERIAL NUMBER LABEL The serial number label is located underneath the round
insect screen.
NOTE: The MAXXFAN is designed to be fully opened or fully closed when the
vehicle is moving.
KEYPAD CONTROLS
KEYPAD FOR MAXXFAN® Deluxe MODELS
5301K · 6401K
CAUTION: When removing insect screen for cleaning, turn the MAXXFAN OFF and
remove the vehicle 12 volt power to the MAXXFAN. When cleaning your MAXXFAN,
use only a mild detergent solution.
FAN ON 1-2-3-4
Turns the Fan Motor ON to the last
selected speed
When the fan is running, cycles
through four (4) speeds, once HIGH
FAN
FAN ON SPEED is reached, fan motor cycles
OFF
1-2-3-4 back to LOW SPEED
Turns the Fan Motor OFF at any selected speed
FAN 5 OFF
INFORMATION AND OPERATING GUIDE
KEYPAD FOR MAXXFAN® Deluxe MODELS
5100K, 5101K, 6200K, 6201K, 7000K, 7001K, 7500K, 7501K, 8000K, 8001K, 8500K,
8501K
KNOB, VENT LID OPEN/CLOSE Manual Opening Models Pull to unlock prior to
turning. Rotate Knob clockwise to Close Vent Lid; Rotate Knob counter-
clockwise to Open Vent Lid. Push “IN” to lock when Vent Lid is open or closed.
Automatic Opening Models Allows closing of the vent lid in the event of RV
power loss. This knob does not lock. Do not push in or pull out. Rotate knob
clockwise to close vent lid; rotate knob counter-clockwise to open vent lid.
Do not use excessive force when operating Knob.
KEYPAD CONTROLS Use Keys on Keypad to control MAXXFAN functions (see
descriptions on next page). NOTE: IR Sensor not on all models
INSECT SCREEN RETAINER KNOB Rotate all 4 knobs 1/2 turn to remove screen.
Caution: Never operate fan with screen removed
THERMOSTAT TEMPERATURE SENSOR
CEILING FAN MODE With the fan motor running, close the Vent Lid to enter
Ceiling Fan Mode. The fan motor will continue to run and circulate air within
the RV cabin.
SERIAL NUMBER LABEL The serial number label is located underneath the round
insect screen.
NOTE: The MAXXFAN is designed to be fully opened or fully closed when the
vehicle is moving.
CAUTION: When removing screen for cleaning, turn the MAXXFAN OFF and remove
the vehicle 12 volt power to the MAXXFAN. When cleaning your MAXXFAN, use only
a mild detergent solution.
6
KEYPAD CONTROLS
KEYPAD FOR MAXXFAN® Deluxe INTAKE/EXHAUST MODELS 5100K, 6200K, 7000K, 7500K,
8000K, 8500K
KEYPAD CONTROLS
KEYPAD FOR MAXXFAN® Deluxe EXHAUST ONLY MODELS 5101K, 6201K, 7001K, 7501K
8001K, 8501K
NOTE: A beeping sound will confirm each key press
ON/OFF: Use this key to start the fan or to turn off the fan. On Automatic
Opening Models the lid will also open or close when the fan is turned on or
off. On Manual Opening Models pushing this key while in Auto Mode will exit
Auto Mode, turn off the fan and the lid will stay in the position you
selected. On Automatic Opening Models this button will exit Auto mode, turn
the fan off, and close the lid.
IN/OUT: Use this key to reverse the direction of the fan, the fan will slow
down and pause for two (2) seconds before resuming operation in the opposite
direction. Note: In Auto Mode the fan direction is automatically positioned to
Exhaust, but may be overridden and changed to Intake by depressing this key.
PLEASE NOTE: THIS KEY HAS BEEN REMOVED ON EXHAUST ONLY MODELS
AUTO: Auto Mode allows the thermostat to turn the fan ON and OFF depending on
the thermostat setting. Press this key once for less than three (3) seconds to
enter Auto Mode, three (3) quick beeps will confirm the MAXXFAN has entered
Auto Mode. To EXIT Auto Mode, press the ON/OFF key. Initial factory set point
for the thermostat is 78°F/25°C. The green LED will light to indicate the
MAXXFAN is in Auto Mode. To adjust, follow instructions below: If no previous
thermostat temperature was entered, or you wish to change a previous set
temperature, press the HOLD TO SET key for more than 3 seconds and you will
hear one long beep and the thermostat will be reset to 78°F. To further adjust
the set temperature, if desired, use the (+) or (-) Arrow keys to adjust at 1°
increments per press. The fan will emit a beeping sound to confirm this
setting. If a previous thermostat temperature was entered, the fan will
remember this temperature setting and the next time you enter Auto Mode, the
fan will start ventilating automatically as directed by the thermostat. The
fan speed will automatically adjust based on the cabin temperature. As cabin
temperature rises, the fan increases in speed. Note: If 12 volt RV power is
removed from the MAXXFAN, the thermostat will be reset to 78°F/25°C.
ARROW – When in Auto Mode: Use the (+) & (-) Arrow keys to adjust the
thermostat set temperature up or down in 1° increments per press. When in
Manual Mode: Use the (+) & (-) Arrow keys to adjust the fan speed up or down.
When the fan speed reaches either the maximum or minimum speed, the fan will
respond with 2 quick beeps to indicate this.
ARROW KEYS PRESSED TOGETHER: Automatic Lift Models Only Press the (+) & (-)
Arrow keys at the same time to Open or Close the lid. The fan motor will
remain in its current state.
7
REMOTE CONTROL OPERATING GUIDE
WIRELESS REMOTE CONTROL FOR MAXXFAN® Deluxe MODELS 7000K · 7500K
Optional for 8000K, 8500K, 8700K, 8900K Models
FAN ON & POWER OFF – Press this button: · To start the fan · To turn the fan off · To exit Auto Mode
Remove protective film from Display Screen
VENT LID POSITION – Press this button to open or close the vent lid · While the fan is running in Manual Mode press once to close the vent lid and enter “Ceiling Fan” Mode. NOTE: This button is not active in Auto Mode. If the fan loses 12volt RV power or power is removed from the fan, use the knob located at the ceiling to manually open or close the vent lid if desired.
AIR EXHAUST / INTAKE – Press this button to reverse the fan from intake or exhaust NOTE: In Auto Mode, the fan direction is automatically positioned to Exhaust, but may be overridden and changed to Intake by depressing this key.
FAN AUTO MODE – Press this button to enter Auto Mode · Auto Mode allows the fan lid to automatically open and the fan motor to operate as dictated by the thermostat set point temperature. Once the cabin temperature cools and reaches the set point temperature, the fan lid will close and the fan motor will shut off. · Pressing this button while in Auto Mode will shut off Auto Mode, close the vent lid and shut off the fan motor.
THERMOSTAT SET TEMPERATURE TEMP + ~ Press this button to increase the Set Temperature for Auto Mode. TEMP – ~ Press this button to decrease the Set Temperature for Auto Mode. NOTE: The thermostat temperature range is from 29°F to 99°F or -2°C to 37°C. To change from Fahrenheit to Celsius on the temperature display, press and hold both set temperature keys simultaneously.
FAN SPEED Fan Speed + ~ Press
SET TEMPERATURE
TRANSMIT
LOW BATTERY INDICATOR
this button to increase
the fan speed. The fan has ten speeds. Fan Speed – ~ Press this
AUTO MODE INDICATOR
ROOM TEMPERATURE
button to decrease the
fan speed. The fan has ten speeds. NOTE: When the fan
FAN ON INDICATOR
VENT LID IN AUTO MODE
speed reaches either the maximum or minimum
CEILING FAN
speed, the fan will respond with 2 quick
FAN OFF INDICATOR
VENT LID POSITION
beep sounds to indicate
this.
LOW BATTERY
FAN SPEED
CEILING FAN MODE
AIR DIRECTION INDICATOR
INDICATOR
· When the battery is at full charge, three black power bars are displayed.
· One or zero power bars displayed indicates the batteries need replacement.
TRANSMISSION SIGNAL · This symbol is displayed on the screen when any button is pressed to indicate the signal was transmitted to the fan. · A beep sound from the ceiling unit indicates the signal from the remote control was received by the fan.
8
REMOTE CONTROL OPERATING GUIDE
WIRELESS REMOTE CONTROL FOR MAXXFAN® Deluxe MODELS 7001K · 7501K
Optional for 8001K, 8501K Models
FAN ON & POWER OFF – Press this button: · To start the fan · To turn the fan off · To exit Auto Mode
Remove protective film from Display Screen
VENT LID POSITION – Press this button to open or close the vent lid · While the fan is running in Manual Mode press once to close the vent lid and enter “Ceiling Fan” Mode. NOTE: This button is not active in Auto Mode. If the fan loses 12volt RV power or power is removed from the fan, use the knob located at the ceiling to manually open or close the vent lid if desired.
AIR OUT
FAN AUTO MODE – Press this button to enter Auto Mode · Auto Mode allows the fan lid to automatically open and the fan motor to operate as dictated by the thermostat set point temperature. Once the cabin temperature cools and reaches the set point temperature, the fan lid will close and the fan motor will shut off. · Pressing this button while in Auto Mode will shut off Auto Mode, close the vent lid and shut off the fan motor.
THERMOSTAT SET TEMPERATURE TEMP + ~ Press this button to increase the Set Temperature for Auto Mode. TEMP – ~ Press this button to decrease the Set Temperature for Auto Mode. NOTE: The thermostat temperature range is from 29°F to 99°F or -2°C to 37°C. To change from Fahrenheit to Celsius on the temperature display, press and hold both set temperature keys simultaneously.
FAN SPEED Fan Speed + ~ Press
SET TEMPERATURE
TRANSMIT
LOW BATTERY INDICATOR
this button to increase
the fan speed. The fan has ten speeds. Fan Speed – ~ Press this
AUTO MODE INDICATOR
ROOM TEMPERATURE
button to decrease the
fan speed. The fan has ten speeds. NOTE: When the fan
FAN ON INDICATOR
VENT LID IN AUTO MODE
speed reaches either the maximum or minimum
CEILING FAN
speed, the fan will respond with 2 quick
FAN OFF INDICATOR
VENT LID POSITION
beep sounds to indicate
this.
LOW BATTERY
FAN SPEED
CEILING FAN MODE
AIR DIRECTION INDICATOR
INDICATOR
· When the battery is at full charge, three black power bars are displayed.
· One or zero power bars displayed indicates the batteries need replacement.
TRANSMISSION SIGNAL · This symbol is displayed on the screen when any button is pressed to indicate the signal was transmitted to the fan. · A beep sound from the ceiling unit indicates the signal from the remote control was received by the fan.
9
OPERATION GUIDE – 1-SWITCH WALL CONTROL
FOR USE WITH MAXXFAN® Deluxe MANUAL OPENING Models
5100K, 5101K, 6200K, 6201K
OPERATION OF 1-SWITCH WALL CONTROL
FAN 1-2-3
When Fan is running, select LOW,
Turns the fan motor ON at the last MEDIUM or HIGH Speed. Once
selected speed
HIGH Speed is reached, the fan
motor cycles back to LOW Speed.
FAN OFF Turns the Fan Motor OFF
OPERATION GUIDE – 2-SWITCH WALL CONTROL
FOR USE WITH MAXXFAN® Deluxe ELECTRIC OPENING Models
7000K, 7001K, 7500K, 7501K, 8000K, 8001K, 8500K, 8501K, 8700K, 8751K, 8900K,
8951K
CONTROL FAN 1-2-3
DESCRIPTION
When Fan is running, select
Turns the fan motor ON at LOW, MEDIUM or HIGH
the last selected speed and Speed. Once HIGH Speed is
OPENS the Vent Lid.
reached, the fan motor cycles
back to LOW Speed.
FAN OFF Turns the Fan Motor OFF and CLOSES the Vent Lid
VENT OPEN
OPENS the Vent Lid
VENT CLOSED
CLOSES the Vent Lid
Fan motor remains in previous state
Fan motor remains in previous state. If fan motor is ON, the MAXXFAN enters
Ceiling Fan Mode
OPERATION GUIDE – 4 KEY WALL CONTROL
FOR MAXXFAN® Deluxe Models 8751K · 8951K
FAN ON 1-2-3-4
VENT OPEN
OPERATION OF 4 KEY WALL CONTROL
FAN ON 1-2-3-4
Turns the fan motor ON at the last selected speed and OPENS the Vent Lid.
When Fan is running, cycles through four (4) fan Speeds. Once HIGH Speed is reached, the fan motor cycles back to LOW Speed.
FAN OFF
Turns the Fan Motor OFF and CLOSES the Vent Lid
FAN OFF
VENT CLOSE
VENT OPEN
OPENS the Vent Lid
VENT CLOSE
CLOSES the Vent Lid
10
Fan motor remains in previous state
Fan motor remains in previous state. If fan motor is ON, the MAXXFAN enters
Ceiling Fan Mode
OPERATION GUIDE – 5 KEY WALL CONTROL
OPTIONAL FOR MAXXFAN® Deluxe Models 7001K · 7501K · 8001K · 8501K
FAN ON/OFF
OPEN/ CLOSE
HOLD TO SET 78°F
AUTO
FAN ON/OFF
AUTO
OPEN/ CLOSE
OPERATION OF 5 KEY WALL CONTROL
Turns the fan motor ON at the last selected speed and OPENS the Vent Lid.
Turns the fan motor OFF and CLOSES Vent Lid. Pressing this key when in AUTO
mode will cause the fan to exit AUTO mode.
Puts the fan in AUTOMATIC thermostat mode. Vent lid will automatically open
and fan will turn on to cool RV when set temperature is reached. Once RV is
cooled down, fan will turn off and vent lid will close. Thermostat is set to
last selected temperature (memory function). Green LED will light to indicate
MAXXFAN is in AUTO mode. Hold key for three (3) seconds to reset thermostat
temperature to 78°F, use (+) & (-) keys to adjust set temperature up or down.
Press ON/OFF key to exit AUTO mode.
Adjusts the fan speed or thermostat set temperature. When fan is on in MANUAL
mode: adjusts fan speed up or down from 10% to 100% (10 speeds). When fan is
in AUTO mode: adjusts thermostat set temperature up or down by 1°F per key
press.
OPENS and CLOSES the motorized Vent Lid. Allows the vent lid to be open or
closed with the fan motor on or off. Close vent lid with fan motor running in
Manual mode to enter Ceiling Fan Mode.
OPERATION GUIDE 6 KEY WALL CONTROL
FOR MAXXFAN® Deluxe Models 8700K · 8900K OPTIONAL FOR MAXXFAN® Deluxe Models
7000K, 7500K, 8000K, 8500K
FAN ON/OFF
OPEN/ CLOSE
HOLD TO SET 78°F
AUTO
IN / OUT
FAN ON/OFF
AUTO
OPEN/ CLOSE IN/OUT
OPERATION OF 6 KEY WALL CONTROL
Turns the fan motor ON at the last selected speed and OPENS the Vent Lid.
Turns the fan motor OFF and CLOSES Vent Lid. Pressing this key when in AUTO
mode will cause the fan to exit AUTO mode.
Puts the fan in AUTOMATIC thermostat mode. Vent lid will automatically open
and fan will turn on to cool RV when set temperature is reached. Once RV is
cooled down, fan will turn off and vent lid will close. Thermostat is set to
last selected temperature (memory function). Green LED will light to indicate
MAXXFAN is in AUTO mode. Hold key for three (3) seconds to reset thermostat
temperature to 78°F, use (+) & (-) keys to adjust set temperature up or down.
Press ON/OFF key to exit AUTO mode.
Adjusts the fan speed or thermostat set temperature. When fan is on in MANUAL
mode: adjusts fan speed up or down from 10% to 100% (10 speeds). When fan is
in AUTO mode: adjusts thermostat set temperature up or down by 1°F per key
press.
OPENS and CLOSES the motorized Vent Lid. Allows the vent lid to be open or
closed with the fan motor on or off. Close vent lid with fan motor running in
Manual mode to enter Ceiling Fan Mode.
Reverses fan motor for either INTAKE or EXHAUST air direction.
11
. . . reinventing comfort!
PLACE CONSUMER LABEL HERE
For additional product information please visit www.AIRXCEL.com AIRXCEL, INC.
– RV Products Division / MAXXAIR
3050 N. St. Francis St. · Wichita, KS 67219 · 316.832.3400
Read User Manual Online (PDF format)