FLUKE 67 MAX Clinical Infrared Thermometer User Manual
- June 6, 2024
- FLUKE
Table of Contents
PRODUCT ANNOUNCEMENT
August 2020
NEW Fluke 67 MAX Clinical Infrared Thermometer
Body temperature results in seconds.
The Fluke 67 MAX Clinical Infrared Thermometer is a handheld non-contact
thermometer optimized for measuring human temperature. The Fluke 67 MAX is
accurate within +/- 0.5 °F over a measurement range of 71.6 °F to 109 °F (+/-
0.3 °C accuracies within a range from 22 °C to 43 °C).
The Fluke 67 MAX has a built-in Body Mode, which adds an offset to account for
the difference between surface skin temperature and core body temperature. The
SCAN functionality allows the user to scan the forehead for the highest
temperature to improve measurement repeatability when
compared to a single spot temperature measurement. This permits convenient
forehead scans within seconds. The Fluke 67 MAX also has a fixed emissivity
setting of 0.98, which is widely accepted as the most accurate setting for
measuring human skin temperature.
The Fluke 67 MAX has been tested to IEC standard 60601-1-2 for electromagnetic
compatibility. This tool has been tested to remain accurate when near other
electronic devices such as portable RF communication equipment (two-way
radios).
The Fluke 67 MAX, with its small size and versatile features, is extremely
easy to use. Plus, it’s rugged enough to take a 2-meter drop, helpful if you
work in busy, crowded work areas. You can also easily clean the surface of the
Fluke 67 MAX with disinfecting wipes.
The Fluke 67 MAX accuracy complies with and accuracy tested in accordance with ASTM E1965-98 and ISO 80601-2-56 standard but is not FDA 510(k) cleared or approved
Fluke 67 MAX Clinical Infrared Thermometer
- Adjustable alarm visually alerts the user when the temperature exceeds a programmed limit.
- Withstands a 6.5 foot (2 meters) drop
- Powered by a single, standard AA battery
- Comes with a three-year warranty
- Offers small, lightweight form factor to slip in a coat pocket
- Clinical infrared thermometer: ± 0.5 °F from 71.6 °F to 109 °F (± 0.3 °C from 22 °C to 43 °C)
- Non-contact thermal scanner device for measurement of human body temperature.
Customer Applications
Elevated body temperature screening of customers or employees entering a
building/facility
Included with Product
67 MAX ,1× thermometer , 1× manual , 1 x AA battery , 1 x registration card ,
1 x statement of calibration
Basic Product Specifications
Specifications | 67 MAX |
---|---|
Temperature measurement range | 71.6 °F to 109.4 °F (22 °C to 43 °C) |
Accuracy | ± 0.5 °F from 71.6 °F to 109.4 °F (± 0.3 °C from 22 °C to 43 °C) |
Spectral response | 8 to 14 microns |
Emissivity | 0.98 (fixed) |
Measurement distance range | 2 to 6 inches (50 to 150 mm) |
Display resolution | 0.1°F (0.1°C) |
Power | AA battery |
Battery life | 100 hours |
Operating temperature | 59 °F to 104 °F (15 °C to 40 °C) |
Drop test | 6.5 feet (2 meters) |
Standard compliance | IEC 60601-1: Pollution degree 2 |
IEC 60825-1: Class 2
ASTM E1965: 22 to 40.0 °C
IEC 80601-2-56: 34.0 °C to 43.0 °C
Introduction Schedule
Open for Orders: 8/28
Public Embargo 9/1 www.fluke.com:
Service Plan
Three-year warranty
Service will be provided at the Fluke Service Centers
Product Pricing and Ordering Information
Fluke model| Description| P/N| UPC codes| Product
including packaging| Origin| US list price
---|---|---|---|---|---|---
L (in)| W (in)| H
(in)
| Wt
(Ibs)
Fluke-67 MAX| FLUKE-67 MAX/AM, IR THERMOMETER (AMERICAS)| 5223603| 195112001387| 7.72| 5.05| 2.71| 0.806| Malaysia| $199.99
Note : For a complete list of products, details, and specifications, please see Distributor Load Sheet
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>